You are on page 1of 1

OPERATING INSTRUCTION

DIGITAL TEMPERATURE CONTROLLER


Model DIMENSION (WxHxD) (mm)
NUTRONICS
DTC-201, DTC-250, DTCW-3, 96X96X140
DTCW-4, BB-900 96X96X140
DTC-201S, DTC-800, 96X96X110

96 mm
192X96X140

96 mm
MS-200S, MS-800S 72X72X110
DTC-400, DTC-2011 192x96x140

SAFETY SUMMARY: 140 mm 188 mm


This manual is meant for personnel involved in wiring, installation, operation, and routine 10 mm 10mm
maintenance of equipment. All safety related codifications, symbols and instructions that appear in
this operating manual or on the equipment must be strictly followed to ensure the safety of the
operating personnel as well as the instrument. If the equipment is not handled in a manner specified
by the manufacturer, it might impair the protection provided by the equipment.
CAUTION : Read complete instructions prior to installation and operation of the unit.
CAUTION : Risk of electric shock.

INSTALLATION INSTRUCTIONS :
1. This equipment, being built-in-type, normally becomes a part of the main control panel and in
such case the terminals do not remain accessible to the end user after installation and internal
wiring.

96mm

92mm
2. Conductors must not come in contact with the internal circuitry of the equipment or else it may 96X96X140
lead to a safety hazard that may in turn endanger life or cause electrical shock to operator. OR 96X96X110
3. Circuit breaker or mains switch must be installed between power source and supply
terminals to facilitate power ON or OFF function. However the switch or breaker must be
installed in a convenient position normally accessible to an operator.

CAUTION:
140mm OR 110mm 92mm
1. The equipment shall not be installed in environmental conditions other than those
10mm 7mm
specified in this manual.
2. Fuse protection: The equipment does not contain built in fuse. Installation of external fuse for
electrical circuitry is highly recommended. Recommended rating of such fuse shall be 275VAC / CONNECTION DIAGRAM :
1Amp.
3. Since this is a built-in-type equipment (finds place in main control panel), its output terminals get R W R W W
RTD RTD
connected to host equipment. Such equipment shall also comply with basic EMI / EMC and + T/C T/C
- - +
safety requirement.
4. The output terminals shall be strictly loaded to the manufacturer specified values / range
NO C NC
INSTALLATION GUIDELINES:
SET-2 (Cool)
Mechanical Installation : For installing the controller SSR
1. Prepare the panel cutout with proper dimensions as shown below; SSR + -
2. Remove the clamp from the controller. + - SET-1 (Heat)
L N NO C NC L N E NO C NC
3. Push the controller into the panel cutout. Secure the controller in its place by pushing the clamp
on the rear side. The screw of the panel of the clamp, must be in the farthest forward slot
4. For proper sealing, tighten the screw, evenly with required torque.
A1 A2 A1 A2
CAUTION:
The equipment in its installed state must not come in close proximity to any heating 230 VAC, 230 VAC,
source, causticvapors, oil, steam. Or other unwanted process by products. 50Hz Supply 50Hz Supply LOAD
LOAD
EMC Guidelines:
1. Use proper input power cables with shortest connections and twisted type. B
2. Layout of connection cables shall be away from any internal EMI source. RC Snubber RC Snubber

SPECIFICATION :
SENSOR INPUT Thermocouple (J,K,PT-PT-RH) RTD,PT-100 As required
DISPLAY 3- Digit, 7 Segment
SENSOR BREAK PROTECTION Auto Switch OFF on Sensor break, '1'
Indication on 4th Digit and reset blanked out For SSR output connected +,- terminal to
POWER SUPPLY 180 - 240 V AC (50/60 Hz) 10% SSR+, - and load in series with SSR
CONTROL ACTION Time Proportionating or ON/OFF Color code of thermocouples
OUTPUT CONTROL 1stage, 2 Stage (SSR or Relay)
Remove wires A1 & A2 from these terminals
Constantan 1.White+Red-
TEMPERATURE SETTING By Potentiometer
For cooling connect B point to NC Fe / K (J) 2. Yellow+Blue-
Specification subjected to change without prior notice.
Maximum load 5A@230VAC Chromel-Alumel 1. Yellow+Red-
OPERATING CONDITIONS : Use snubber to increase the life of internal relay
HUMIDITY UPTO 95% OF Rh Cr/Al(k) 2. White+Blue-
OPERATING TEMP. 0-50C
CABINET MATERIAL : ABS Plastic or Flame Retendant Plastic.
ACCESSORIES : OPERATING INSTRUCTION
TWO SIDE MOUNTING CLAMPS ARE PROVIDED
To set the desired temperature press the set switch and use the screw
Front Panel Cover (Optional) driver to adjust the potentiometer untill the desired value is achived
PANEL DIAMENSION : after that release the switch the unit will shown actual process temperature value. At the back side of
instrument one potentiometer is provided to adjust the temperature error of the instrument.

Panel cutout Only for Model MS-800S, DTC-800


There is one additional pot is provided to adjust the heat of the process, this pot is provided on the right
side of SET POINT potentiometer. Also there is one additional pot is provided at the back side of
instrument which is use to adjust the proportional band.
72mm

68mm

72X72X110mm

110mm 68mm
10mm 10mm

You might also like