xls Effective Length of Column

Project No. 66-6294-700 VVF

Column on Grid C1/E -17A

Calculation of Effective Lenghth of Column Column No. 1005 Column from Footing to Plinth Lvl
Beams meeting at bottom joint Beams meeting at Top joint columns at joint

X-Direction Z- Direction X-Direction Z- Direction Bottom column Top column

beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 Along X direction Along Z direction Along X direction Along Z direction

EL of roof story joint (M) 99.025 b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.)

EL of floor joint (M) 97.3 0 0 0 0 0 0 0 0 0.35 0.7 0 0 0 0 0 0 0 0 0 0 0.4 0.75 0 0


Length of
Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of column Length of column Length of column Length of column
beam
Length of Column (M) 1.725 8.25 5 6.2 6.2 8.25 5 2.47 6.2 0.6 0.6 4.925 6.65

Write F for far Write F for far Write F for far Write F for far Write F for far Write F for far
Write F for far end Write F for far end
end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and
Fixed and Nothing Fixed and Nothing
Breadth of Column (M) b Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far
0.4 end Hinged for far end Hinged for far end Hinged
(Along z dir) end Hinged end Hinged end Hinged end Hinged end Hinged
Depth of Column (M) d (Along
0.75 F F F F F F F F
X dir)
Moment of inertia of column
0.0141 0.0000 0.0000 0.0000 0.0000 0.0100 0.0000 0.0000 0.0000 0.0000 0.0000 0.0141 0.0000
(Iz) bd3/12 M4
Moment of inertia of column
0.0040 0.0000 0.0000 0.0000 0.0000 0.0018 0.0000 0.0000 0.0000 0.0000 0.0000 0.0029 0.0000
(Ix)db3/12 M4
Total stiffnesses of Total stiffnesses of Total stiffnesses of Total stiffnesses of
Total stiffnesses of beams at top Total stiffnesses of beams at top Total stiffnesses of beams at Total stiffnesses of beams at bottom
Iz/l of column = Kccz 0.0082 Columns at Bottom Columns at Bottom columns at top Columns at top
joint x direction joint z direction bottom joint x direction joint z direction
joint x direction joint Z direction joint X direction joint Z direction

Ix/l of column = Kccx 0.002319 0.0000 0.000000 0.0018 0.0000 0.0082 0.0023 0.0110 0.0023188

Ratio of stiffnesses at bottom (for X direction length) [B2] Ratio of stiffnesses at top joint (for X direction length) [B1]

1.0000 0.8582

Ratio of stiffnesses at bottom (for Z direction length) [B2] Ratio of stiffnesses at top joint (for Z direction length) [B1]

1.00000 1.0000

Effective length factor

For calculation l effective in "X" direction take a value of B1 and B2 = 0.8582 & 0.0000 respectively. 1.7

For calculation l effective in "Z" direction take a value of B1 and B2 = 1.0000 & 0.00000 respectively. -

Note : 1) If there is no beam in either x direction or in z direction at a particular joint pl put b = 0 and z=0 and at least 1 in cell of "Length of beam" .

2) If there is no column in bottom side or top side pl. put b=0 and d=0 with at least length equal to 1 m

3) Users are supposed to input the values in yellow marked cells

PREP BY: SSK


11/30/2017
CHECKED BY:
Page No.2
Effective Length of Column
date :11/30/2017

Project No. 66-6294-700 VVF

Column on Grid C1/E -17A

Calculation of Effective Lenghth of Column Column No. 5005/2005 Column from Plinth lvl to First Floor
Beams meeting at bottom joint Beams meeting at Top joint columns at joint

X-Direction Z- Direction X-Direction Z- Direction Bottom column Top column

beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 Along X direction Along Z direction Along X direction Along Z direction

EL of roof story joint (M) 103.95 b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.)

EL of floor joint (M) 99.025 0.35 0.7 0 0 0 0 0 0 0.23 0.75 0 0 0 0 0 0 0.4 0.75 0 0 0.4 0.75 0 0
Length of
Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of column Length of column Length of column Length of column
beam
Length of Column (M) 4.925 8.25 5 2.47 6.2 8.25 5 2.47 6.2 1.725 3.25 3.25 5

Write F for far Write F for far Write F for far Write F for far Write F for far Write F for far
Write F for far end Write F for far end
end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and
Fixed and Nothing Fixed and Nothing
Breadth of Column (M) b Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far
0.4 end Hinged for far end Hinged for far end Hinged
(Along z dir) end Hinged end Hinged end Hinged end Hinged end Hinged
Depth of Column (M) d (Along
0.75 F F F F F F F F
X dir)
Moment of inertia of column
0.0141 0.0100 0.0000 0.0000 0.0000 0.0081 0.0000 0.0000 0.0000 0.0141 0.0000 0.0141 0.0000
(Iz) bd3/12 M4
Moment of inertia of column
0.0040 0.0018 0.0000 0.0000 0.0000 0.0015 0.0000 0.0000 0.0000 0.0082 0.0000 0.0043 0.0000
(Ix)db3/12 M4
Total stiffnesses of Total stiffnesses of Total stiffnesses of Total stiffnesses of
Total stiffnesses of beams at top Total stiffnesses of beams at top Total stiffnesses of beams at Total stiffnesses of beams at bottom
Iz/l of column = Kccz 0.0029 Columns at Bottom Columns at Bottom columns at top Columns at top
joint x direction joint z direction bottom joint x direction joint z direction
joint x direction joint Z direction joint X direction joint Z direction

Ix/l of column = Kccx 0.000812 0.0018 0.000000 0.0015 0.0000 0.0110 0.0008 0.0072 0.0008122

Ratio of stiffnesses at bottom (for X direction length) [B2] Ratio of stiffnesses at top joint (for X direction length) [B1]

0.8582 0.8301

Ratio of stiffnesses at bottom (for Z direction length) [B2] Ratio of stiffnesses at top joint (for Z direction length) [B1]

1.00000 1.0000

Effective length factor

For calculation l effective in "X" direction take a value of B1 and B2 = 0.8301 & 0.8582 respectively. 2.8

For calculation l effective in "Z" direction take a value of B1 and B2 = 1.0000 & 0.00000 respectively. -

Note : 1) If there is no beam in either x direction or in z direction at a particular joint pl put b = 0 and z=0 and at least 1 in cell of "Length of beam" .

2) If there is no column in bottom side or top side pl. put b=0 and d=0 with at least length equal to 1 m

3) Users are supposed to input the values in yellow marked cells

11/30/2017 05:32:21
Project No. 66-6294-700 VVF

Column on Grid C1/E -17A

Calculation of Effective Lenghth of Column Column No. 6005 Column from First floor to Second floor
Beams meeting at bottom joint Beams meeting at Top joint columns at joint

X-Direction Z- Direction X-Direction Z- Direction Bottom column Top column

beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 Along X direction Along Z direction Along X direction Along Z direction

EL of roof story joint (M) 107.2 b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.)

EL of floor joint (M) 103.95 0.23 0.75 0 0 0 0 0 0 0.3 0.7 0 0 0 0 0 0 0.4 0.75 0 0 0.4 0.75 0 0
Length of
Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of column Length of column Length of column Length of column
beam
Length of Column (M) 3.25 8.25 5 2.47 6.2 8.25 5 2.47 6.2 4.925 6.65 5 5

Write F for far Write F for far Write F for far Write F for far Write F for far Write F for far
Write F for far end Write F for far end
end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and
Fixed and Nothing Fixed and Nothing
Breadth of Column (M) b Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far
0.4 end Hinged for far end Hinged for far end Hinged
(Along z dir) end Hinged end Hinged end Hinged end Hinged end Hinged
Depth of Column (M) d (Along
0.75 F F F F F F F F
X dir)
Moment of inertia of column
0.0141 0.0081 0.0000 0.0000 0.0000 0.0086 0.0000 0.0000 0.0000 0.0141 0.0000 0.0141 0.0000
(Iz) bd3/12 M4
Moment of inertia of column
0.0040 0.0015 0.0000 0.0000 0.0000 0.0016 0.0000 0.0000 0.0000 0.0029 0.0000 0.0028 0.0000
(Ix)db3/12 M4
Total stiffnesses of Total stiffnesses of Total stiffnesses of Total stiffnesses of
Total stiffnesses of beams at top Total stiffnesses of beams at top Total stiffnesses of beams at Total stiffnesses of beams at bottom
Iz/l of column = Kccz 0.0043 Columns at Bottom Columns at Bottom columns at top Columns at top
joint x direction joint z direction bottom joint x direction joint z direction
joint x direction joint Z direction joint X direction joint Z direction

Ix/l of column = Kccx 0.001231 0.0015 0.000000 0.0016 0.0000 0.0072 0.0012 0.0071 0.0012308

Ratio of stiffnesses at bottom (for X direction length) [B2] Ratio of stiffnesses at top joint (for X direction length) [B1]

0.8301 0.8208

Ratio of stiffnesses at bottom (for Z direction length) [B2] Ratio of stiffnesses at top joint (for Z direction length) [B1]

1.00000 1.0000

Effective length factor

For calculation l effective in "X" direction take a value of B1 and B2 = 0.8208 & 0.8301 respectively. 2.75

For calculation l effective in "Z" direction take a value of B1 and B2 = 1.0000 & 0.00000 respectively. -

Note : 1) If there is no beam in either x direction or in z direction at a particular joint pl put b = 0 and z=0 and at least 1 in cell of "Length of beam" .

2) If there is no column in bottom side or top side pl. put b=0 and d=0 with at least length equal to 1 m

3) Users are supposed to input the values in yellow marked cells


Project No. 66-6294-700 VVF

Column on Grid C1/E -17A

Calculation of Effective Lenghth of Column Column No. 3005 Column from First floor to Second floor
Beams meeting at bottom joint Beams meeting at Top joint columns at joint

X-Direction Z- Direction X-Direction Z- Direction Bottom column Top column

beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 Along X direction Along Z direction Along X direction Along Z direction

EL of roof story joint (M) 112.2 b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.)

EL of floor joint (M) 107.2 0.3 0.7 0 0 0 0 0 0 0.3 0.7 0 0 0 0 0 0 0.4 0.75 0 0 0.4 0.75 0 0
Length of
Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of column Length of column Length of column Length of column
beam
Length of Column (M) 5 8.25 5 2.47 6.2 8.25 5 2.47 6.2 3.25 6.65 5 5

Write F for far Write F for far Write F for far Write F for far Write F for far Write F for far
Write F for far end Write F for far end
end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and
Fixed and Nothing Fixed and Nothing
Breadth of Column (M) b Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far
0.4 end Hinged for far end Hinged for far end Hinged
(Along z dir) end Hinged end Hinged end Hinged end Hinged end Hinged
Depth of Column (M) d (Along
0.75 F F F F F F F F
X dir)
Moment of inertia of column
0.0141 0.0086 0.0000 0.0000 0.0000 0.0086 0.0000 0.0000 0.0000 0.0141 0.0000 0.0141 0.0000
(Iz) bd3/12 M4
Moment of inertia of column
0.0040 0.0016 0.0000 0.0000 0.0000 0.0016 0.0000 0.0000 0.0000 0.0043 0.0000 0.0028 0.0000
(Ix)db3/12 M4
Total stiffnesses of Total stiffnesses of Total stiffnesses of Total stiffnesses of
Total stiffnesses of beams at top Total stiffnesses of beams at top Total stiffnesses of beams at Total stiffnesses of beams at bottom
Iz/l of column = Kccz 0.0028 Columns at Bottom Columns at Bottom columns at top Columns at top
joint x direction joint z direction bottom joint x direction joint z direction
joint x direction joint Z direction joint X direction joint Z direction

Ix/l of column = Kccx 0.000800 0.0016 0.000000 0.0016 0.0000 0.0071 0.0008 0.0056 0.0008000

Ratio of stiffnesses at bottom (for X direction length) [B2] Ratio of stiffnesses at top joint (for X direction length) [B1]

0.8208 0.7830

Ratio of stiffnesses at bottom (for Z direction length) [B2] Ratio of stiffnesses at top joint (for Z direction length) [B1]

1.00000 1.0000

Effective length factor

For calculation l effective in "X" direction take a value of B1 and B2 = 0.7830 & 0.8208 respectively. 2.5

For calculation l effective in "Z" direction take a value of B1 and B2 = 1.0000 & 0.00000 respectively. -

Note : 1) If there is no beam in either x direction or in z direction at a particular joint pl put b = 0 and z=0 and at least 1 in cell of "Length of beam" .

2) If there is no column in bottom side or top side pl. put b=0 and d=0 with at least length equal to 1 m

3) Users are supposed to input the values in yellow marked cells


Project No. 66-6294-700 VVF

Column on Grid C1/E -17A

Calculation of Effective Lenghth of Column Column No. 4005 Column from second floor to roof lvl.
Beams meeting at bottom joint Beams meeting at Top joint columns at joint

X-Direction Z- Direction X-Direction Z- Direction Bottom column Top column

beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 beam 1 beam 2 Along X direction Along Z direction Along X direction Along Z direction

EL of roof story joint (M) 117.2 b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.) b(M.) D(M.)

EL of floor joint (M) 112.2 0.3 0.7 0 0 0.3 0.75 0 0 0.3 0.6 0 0 0.23 0.7 0 0 0.4 0.75 0.75 0.4 0 0 0 0
Length of
Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of beam Length of column Length of column Length of column Length of column
beam
Length of Column (M) 5 8.25 5 2.47 6.2 8.25 5 2.47 6.2 5 5 3.25 5

Write F for far Write F for far Write F for far Write F for far Write F for far Write F for far
Write F for far end Write F for far end
end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and end Fixed and
Fixed and Nothing Fixed and Nothing
Breadth of Column (M) b Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far Nothing for far
0.4 end Hinged for far end Hinged for far end Hinged
(Along z dir) end Hinged end Hinged end Hinged end Hinged end Hinged
Depth of Column (M) d (Along
0.75 F F F F F F F F
X dir)
Moment of inertia of column
0.0141 0.0086 0.0000 0.0105 0.0000 0.0054 0.0000 0.0066 0.0000 0.0141 0.0040 0.0000 0.0000
(Iz) bd3/12 M4
Moment of inertia of column
0.0040 0.0016 0.0000 0.0064 0.0000 0.0010 0.0000 0.0040 0.0000 0.0028 0.0008 0.0000 0.0000
(Ix)db3/12 M4
Total stiffnesses of Total stiffnesses of Total stiffnesses of Total stiffnesses of
Total stiffnesses of beams at top Total stiffnesses of beams at top Total stiffnesses of beams at Total stiffnesses of beams at bottom
Iz/l of column = Kccz 0.0028 Columns at Bottom Columns at Bottom columns at top Columns at top
joint x direction joint z direction bottom joint x direction joint z direction
joint x direction joint Z direction joint X direction joint Z direction

Ix/l of column = Kccx 0.000800 0.0016 0.006405 0.0010 0.0040 0.0056 0.0016 0.0028 0.0008000

Ratio of stiffnesses at bottom (for X direction length) [B2] Ratio of stiffnesses at top joint (for X direction length) [B1]

0.7830 0.7412

Ratio of stiffnesses at bottom (for Z direction length) [B2] Ratio of stiffnesses at top joint (for Z direction length) [B1]

0.19988 0.1669

Effective length factor

For calculation l effective in "X" direction take a value of B1 and B2 = 0.7412 & 0.7830 respectively. 2.25

For calculation l effective in "Z" direction take a value of B1 and B2 = 0.1669 & 0.19988 respectively. -

Note : 1) If there is no beam in either x direction or in z direction at a particular joint pl put b = 0 and z=0 and at least 1 in cell of "Length of beam" .

2) If there is no column in bottom side or top side pl. put b=0 and d=0 with at least length equal to 1 m

3) Users are supposed to input the values in yellow marked cells