205 Read Power Tuning Target Value Setting: _ExxDRT205_ReadPTSV
Basic Reads the power tuning target value (set value) of a Digital Type Sensor in the DeviceNet network.
function
Symbol Start Trigger _ExxDRT205_ReadPTSV
(BOOL) (BOOL)
EN ENO
Busy Flag (INT) (BOOL) FB Busy Flag
Master Unit number MasterUnitNo FB_BUSY
(INT) (BOOL) FB Normal End
Slave node address NodeNo FB_OK
(INT) (BOOL)
FB Error End
Sensor Amplifier unit number SensorUnitNo FB_NG
(UINT)
Power Tuning Target Value
PTSV
EN input Connect EN to an OR between an upwardly differentiated condition for the start trigger and the FB_BUSY
condition output from the FB.
Restrictions Always use an upwardly differentiated condition for EN.
Input If the input variables are out of range, the ENO Flag will turn OFF and the FB will not be processed.
variables
Output This FB requires multiple cycles to process. Always connect an OR including the FB_BUSY output
variables variable to the EN input variable to ensure that the FB is processed to completion (see Symbol).
Do not turn the FB_BUSY output variable ON or OFF outside the FB.
_ExxDRT205_ReadPTSV (2/3)
Application A Digital Sensor Communication Unit (node 11) is connected to a DeviceNet Unit with Master unit number
example 10. When bit A turns ON, the function reads the power tuning target value of the Sensor Amplifier with unit
number 2 and outputs the result to D00100.
M a s te r U n it N o .
10
DRM CPU
R e a d th e p o w e r tu n in g ta rg e t v a lu e o f U n it n u m b e r 2 .
S ta rt T rig g e r
B it A _ E xxD R T 2 0 5 _ R e a d P TS V
(B O O L ) (B O O L )
M a s te r U n it n u m b e r EN ENO
F B B u s y F la g F B B u s y F la g
&10 (IN T) (B O O L )
B it B B it B
S la v e n o d e a d d re s s M a s te rU n itN o FB_BUSY
F B N o rm a l E n d
&11 (IN T) (B O O L )
NodeNo FB_OK B it C
S e n s o r A m p lifie r u n it n u m b e r F B E rro r E n d
(IN T) (B O O L )
&2 B it D
S e n s o rU n itN o FB_NG
(U IN T) P o w e r T u n in g Ta rg e t V a lu e
P TS V D100
N o rm a l E n d F la g
B it C
P ro c e s s in g afte r p o w e r tun in g ta rg et
va lu e h a s b e e n re a d
Related Communication Unit For Digital Fiber Sensor E3X-DRT21-S (DeviceNet) (Z223-E1)
manuals
Section 2 E3X-DRT21 for Device Net Communications
CS/CJ Series Communications Commands Reference Manual (W342-E1)
5-1 Command Lists
_ExxDRT205_ReadPTSV (3/3)
Variable Tables
Input Variables
Name Variable name Data type Default Range Description
EN EN BOOL 1 (ON): FB started
0 (OFF): FB not started.
Master Unit No. MasterUnitNo INT &0 &0 to &15 Specify the unit number of the DeviceNet
#0 to #F Unit.
Slave node NodeNo INT &0 &0 to &63 Specify the node address of the slave.
address
Sensor Amplifier SensorUnitNo INT &1 &1 to &13 Depending on the communication mode
unit number or setting, the maximum number of
&1 to &16 connectable Units is either 13 or 16 Units.
Specify a unit number within the allowed
range.
Refer to the Related Manuals for details.
Output Variables
Name Variable name Data type Range Description
ENO ENO BOOL 1 (ON): FB processed normally.
(May be omitted.) 0 (OFF): FB not processed or ended in an error.
FB Busy Flag FB_BUSY BOOL Automatically turns OFF when processing is
completed.
FB Normal End FB_OK BOOL Turns ON for one cycle when processing ends
normally.
FB Error End FB_NG BOOL Turns ON for one cycle when processing ends in an
error.
Power Tuning PTSV UINT Outputs the power tuning target value.
Target Value
Internal Variables
Internal variables are not output from the FB.
If the FB_NG Flag turns ON, the following internal variables can be monitored to obtain information on the error.
Name Variable name Data type Range Description
FINS error code FINS_ErrorCode WORD The FINS error code is output. A code of #0000 is
output for a normal end. Refer to the Related Manuals
for details on the error codes.
Explicit message Explicit_ErrorCode WORD Outputs the explicit message error code. A code of
error code #0000 is output for a normal end. Refer to the Related
Manuals for details on the error codes.
Version History
Version Date Contents
1.00 2005.4. Original production
Note
This manual is a reference that explains the function block functions.
It does not explain the operational limitations of Units, components, or combinations of Units and components. Always read
and understand the Operation Manuals for the systems Units and other components before using them.