You are on page 1of 5

Int J Adv Manuf Technol (2010) 51:415419

DOI 10.1007/s00170-008-1867-9

SPECIAL ISSUE - ORIGINAL ARTICLE

Modeling and simulation of a parallel plate heat sink


using computational fluid dynamics
R. Arularasan & R. Velraj

Received: 1 March 2008 / Accepted: 15 September 2008 / Published online: 20 December 2008
# Springer-Verlag London Limited 2008

Abstract Desktop computers have changed to accommo- Keywords Heat sink . Thermal resistance .
date increasing power, approaching 100 W. Heat dissipation Design of experiments . CFD solver . ANOVA
becomes a significant issue in efficiency promotion and
stable operation of air-cooled microelectronics and power
electronics components and assemblies. Finned heat sinks 1 Introduction
are commonly used devices for enhancing heat transfer
from air-cooled microelectronics and power electronics The use of semiconductor chips has proliferated into
components and assemblies. The use of finned heat sinks virtually the entire range of consumer electronics. The
increases the effective surface area for convective heat explosive growth of personal computers and telecommuni-
transfer, reducing the thermal resistance and operating cations, and the demand for increased performance, drives
temperatures in air-cooled electronics. The task of selecting chip designs. The continuing increase of power densities in
the best heat sink for a particular application from the electronics packages and the simultaneous drive to reduce
hundreds of configurations available from the various the size and weight of electronic products have led to an
manufacturers can be a formidable task for an engineer. In increased importance on thermal management issues in this
a typical heat sink design, the objective is to achieve target industry. The growth in the number of devices per chip, in
heat dissipation, while restricting the consumption of accordance with Moores Law, has resulted in an exponen-
valuable resources such as mass, fan power, pressure drop, tial increase in energy dissipation requirements [1]. The
and space claim. In this research work, preliminary studies most common method for cooling electronic packages is
have been carried out for the performance improvement of the use of aluminum heat sinks. These heat sinks provide a
a parallel-plate heat sink considering the various geometric large surface area for the dissipation of heat and effectively
parameters, such as number of fins, fin length, fin height, reduce the thermal resistance of a package. Current
and base height. The modeling and simulation of the heat estimates for future cooling needs in middle-end computers
sink is carried out with the computational fluid dynamics and telecom applications point to the need for the
package. The results are analyzed using analysis of variance development of more efficient compact heat exchangers
and response graphs. employing active heat transfer methods in combination with
ambient air [2]. In the near term, however, air cooling in
conjunction with traditional heat sinks will continue to be
the method of choice for heat dissipation due to the ease of
R. Arularasan (*)
application, reliability, and low cost of this technology.
Department of Mechanical Engineering,
SSN College of Engineering, Unfortunately, heat sinks often take up much space and
Chennai, Tamilnadu 603 110, India contribute to the weight and cost of the product. Conse-
e-mail: arularasanr@ssn.edu.in quently, the need for new and more effective ways to
dissipate this energy is becoming increasingly urgent.
R. Velraj
Institute for Energy Studies, CEG, Anna University, Traditionally, the performance of heat sinks is measured
Chennai, Tamilnadu 600 025, India experimentally and the results are made available in the
416 Int J Adv Manuf Technol (2010) 51:415419

Fig. 1 A typical heat sink Fig. 2 Computational model of heat sink

form of design graphs in heat sink catalogues. This dimensions of the cooling channels [5], location and
characterization method has been the topic of much debate concentration of heat sources, and the airflow bypass due
as vendors have applied different standards or interpreta- to flow resistance through the heat sink. These parameters
tions to determine the characterization of heat sinks [3]. make the optimal design of a heat sink very difficult.
Analytical and empirical formulations for the fin efficiency, Optimal heat sink design for an electronic system is
pressure drop, and the heat transfer coefficient have also extremely time-consuming [6]. Therefore, in this work,
been used in the design process to determine the optimal we have adapted an approach that combines a heat sinks
heat sink design [4]. Because of compelling market numerical model with design of experiments (DOE)
requirements, design optimization of new electronic devices methodology, thereby incorporating the influence of the
is often found to be prohibitive. Techniques such as one design variables automatically. This approach considered
variable at a time are useful for simple designs; however, geometric parameters of the heat sink that have the
they often fall short for real-world applications. In recent individual and interaction effects on the target heat
years, maturation of computational fluid dynamics (CFD) dissipation.
software codes tailored for applications in the electronics
industry and the availability of powerful low-cost work-
stations have made possible the simultaneous solution of 3 Modeling and simulation
both the heat transfer and fluid dynamic problems in
undertaking thermal design of electronic devices. To A typical parallel plate heat sink considered in this present
achieve an optimal design of heat sink for an effective heat work is shown in Fig. 1. The important geometric variables
transfer, newer methodologies or techniques are to be considered are number of fins (N), fin length (L), fin height
identified (H), and base height (BH). The range of geometric
parameters of the chosen heat sink for the present study is
given in Table 1. Considering the various geometric
2 Influence of the geometric parameters in a heat sink variables present in the modeling and simulation, the
DOE approach with L27 orthogonal array has been applied
The performance of a heat sink depends on a number of to reduce the simulation time and costs involved [7].
parameters including the thermal conduction resistance,

Table 2 Other parameters used in the model


Table 1 Range of geometric parameter used in the heat sink model
Heat sink type Parallel plate heat sink
Parameter Level 1 Level 2 Level 3
Heat sink material Aluminum
Number of fins (N) 20 30 40 Maximum thermal load in the heat sink 150.0 W
Fin length (L) mm 50 75 100 Ambient temperature 25C
Fin height (H) mm 10 20 30 Minimum velocity of the air flow 0.0299 m/s
Base height (BH) mm 2.5 5 7.5 Maximum velocity of the air flow 2.38 m/s
Int J Adv Manuf Technol (2010) 51:415419 417

include conservation of mass, conservation of momentum,


and conservation of energy. A typical computational
model of the parallel plate heat sink is shown in Fig. 2.
Various specifications and other parameters used in the
modeling and simulation of the heat sink are given in
Table 2.

4 Results and discussions

The symmetry available in the heat sink is utilized to save


the computation power and cost. Therefore, only the
symmetrical portion of the heat sink alone is simulated in
this work. The temperature contour in the heat sink is
shown in Fig. 3 as a sample output.
The results of the simulation are shown in Table 3. The
Fig. 3 Temperature contour in the heat sink
results obtained through the simulation are analyzed using
analysis of variance (Table 4) and response graphs
Modeling and simulation of the heat sink have been (Fig. 4).
carried out using a CFD package. This package uses a Analysis of variance has shown the significant parame-
systems CFD solver for fluid flow and a full three- ters and their levels for the output parameter, namely, low
dimensional conduction solver. This solvers features thermal resistance. From Table 4 and Fig. 4, it is evident

Table 3 Simulation results

Input Output

Number of fins Fin length (mm) Fin height (mm) Base height (mm) Thermal resistance C/W

20 50 10 2.5 5.4
20 50 20 5.0 1.2
20 50 30 7.5 0.7
20 75 10 5.0 4.8
20 75 20 7.5 1.1
20 75 30 2.5 0.7
20 100 10 7.5 3.8
20 100 20 2.5 1.6
20 100 30 5.0 0.7
30 50 10 5.0 7.9
30 50 20 7.5 1.9
30 50 30 2.5 1.2
30 75 10 7.5 6.0
30 75 20 2.5 3.1
30 75 30 5.0 1.2
30 100 10 2.5 9.8
30 100 20 5.0 2.9
30 100 30 7.5 1.2
40 50 10 7.5 8.5
40 50 20 2.5 5.2
40 50 30 5.0 2.3
40 75 10 2.5 13.2
40 75 20 5.0 4.4
40 75 30 7.5 2.2
40 100 10 5.0 8.7
40 100 20 7.5 3.7
40 100 30 2.5 2.9
418 Int J Adv Manuf Technol (2010) 51:415419

Table 4 Analysis of variance table for thermal resistance

Source Pool DF S V F S Remarks

N 2 53.4429 26.7215 151.9503 53.0912 19.13 99%


L 2 0.3989 0.1994 1.1341 0.0472 0.02 NS
H 2 185.5398 92.7699 527.5316 185.1881 67.34 99%
BH 2 11.2163 5.6081 31.8903 10.8645 3.95 99%
E 6 6.4162 1.0694 6.0809 6.3610 1.95 90%
NL 4 6.2876 1.5719 8.9385 5.5842 2.03 95%
NH 4 10.9942 2.7486 15.6296 10.2908 3.74 99%
LH Y 4 0.7034 0.1759 NS
(e) 4 0.7034 0.1759 4.5723 1.66
Total 26 274.9993 10.5769

that, for a low thermal resistance in the selected heat sink 5 Conclusion
model, the geometric parameters, namely, the number of
fins (20), fin height (30 mm), and base height (7.5 mm), are In this research work, preliminary studies for the optimal
found to be significant at low, high, and high levels, design of the heat sink have been carried out on a parallel-
respectively. By keeping a minimum number of fins, the plate heat sink considering the geometric parameters such
designer can allow maximum possible fin pitch so that the as number of fins, fin length, fin height, and base height
pressure drop will be minimal and air flow will be maximal using DOE methodology in conjunction with simulation
for an improved heat transfer in the heat sink. results. The simulation results are found to be in good
Similarly, to increase the heat transfer area of the heat agreement with the previous researchers work found in the
sink, instead of increasing the fin length and number of literature. However, they have not considered the interac-
fins, the designer can increase the fin height such that any tion effects of the geometric parameters. This research work
adverse pressure drop can be avoided. The interaction has considered the interaction effects of various geometric
effects of the geometric parameters, namely, the number of parameters, and they are found to be influencing. The
fins (low level) with fin length (high level) and fin length simulation results are analyzed using analysis of variance
(low level) with fin height (high level), are found to be and response graphs. The individual effects of geometric
significant for a low thermal resistance in the heat sink. parameters, such as number of fins, fin height, and base
These results are found to be in good agreement with the height, are found to be significant for a low thermal
other researchers work found in the literature [1, 3, 4]. resistance in the heat sink. The interaction effect of the
However, the previous researchers have not considered the number of fins and fin length, as well as the number of fins
interaction effects. and fin height, are found to be significant for a low thermal

Fig. 4 Mean response graphs


for thermal resistance
Int J Adv Manuf Technol (2010) 51:415419 419

resistance in the heat sink. This study will benefit the SS Sum of square
design engineers involved in electronic cooling. Using the V Error variance or mean square
approach presented in this research work, the design W Width of the heat sink of the heat sink
engineers can carry out optimization of parametric com- Y Pooled factor
puter-aided design models, for the selection or design of
heat sink for effective thermal management in their
electronic assemblies. In our future research work, we aim References
to extend this approach in our study for the performance
improvement and parametric optimization of the above heat 1. Copeland D (2000) Optimization of parallel plate heat sinks for
sink, additionally including the other influencing output forced convection. In: Sixteenth annual IEEE semiconductor
thermal measurement and management symposium, San Jose,
parameters, namely, minimum pressure drop, the average
March 2000, pp 266272
heat transfer coefficient, and the average air flow velocity 2. Chen Y-T, Kang S-W, Tuh W-C, Hsiao T-H (2004) Experimental
in the heat sink. investigation of fluid flow and heat transfer in micro channels.
Tamkang J Sci Eng 7(1):1116
3. Bar-Cohen A, Iyengar M (2002) Design and optimization of air-
cooled heat sinks for sustainable development. IEEE Trans
Nomenclature Compon Packag Technol 25(4):584591 (December)
4. Teertstra P, Yovanovich MM, Culham JR, Lemczyk T (1999)
Contribution ratio Analytical forced convection modeling of plate fin heat sinks. In:
BH Base height of the heat sink (mm) Fifteenth annual IEEE semiconductor thermal measurement and
DF Degree of freedom management symposium, San Diego, March 1999, pp 3441
5. Lee S (1995) Optimum design and selection of heat sinks. In:
e Pooled error
Eleventh annual IEEE semiconductor thermal measurement and
F Variance ratio management symposium, San Jose, February 1995, pp 4854
H Fin height of the heat sink (mm) 6. Stewart T, Stiver DW (2004) Thermal optimization of electronic
L Fin length of the heat sink (mm) systems using design of experiments based on numerical inputs. In:
IEEE semiconductor thermal measurement and management
N Number of fins in the heat sink
symposium, San Jose, March 2004, pp 135142
NS Not significant 7. Park SH (1996) Robust design and analysis for quality engineering.
S Pure sum of square Chapman & Hall, London