You are on page 1of 1

E1 Test Report

Report name Prueba E1 albedo00250


Customer Colmedica
Department Antioquia
Company level3
Location Manila Poblado
Operator level3
Start Time Sat Sep 16 09:25:29 2017
Elapsed Time 00:10:08
Test Unit AT-2048 E1/Datacom Tester
Serial number M2M0652P
Software version 1.20.1

Port A: Global results


Status Measured Objective

Max. attenuation PASS 3.0 dB 6.0 dB


Max. deviation PASS 6.64 ppm 50.00 ppm
Max. TSE rate PASS -- 1.00e-06
Performance (Near End) ----
Performance (Far End) ----

Test Unit Configuration


Port A Port B

Mode E1 endpoint E1 endpoint


Connector Unbalanced ----
Connection mode Endpoint ----

TX code HDB3 ----


TX clock source Synthesized ----
TX clock offset (ppm) 0.000 ppm --- ppm
TX structure PCM31 ----
TX Pattern ---- ----

RX code HDB3 ----


RX structure PCM31 ----
RX Pattern ---- ----

Port A: Defects
Event Seconds

LOS 44 s
AIS 0 s
LOF 2 s
RAI 0 s
CRC-LOM ---- s
CAS-LOM ---- s
MAIS ---- s
MRAI ---- s
LSS ---- s
All 0 ---- s
All 1 ---- s
Slips ---- s

Port A: Anomalies
Event Count Rate Seconds

Code 4852 4.200604e-06 2 s


FAS 0 0.000000e+00 0 s
CRC ---- ---- ---- s
REBE ---- ---- ---- s
MFAS ---- ---- ---- s
TSE ---- ---- ---- s

(c) 2011 ALBEDO Telecom