You are on page 1of 81

OWNER IN-CHARGE IN SHIFT

Sheduled Date for the Month

BFP Starting/Changeover
Change Over Date

STEP ACTIVITY DESCRIPTION

Ensure that Boiler Feed Pump to be taken in service is not under any type of work permit, and
1 electrical power is available

In case of standby mode electrical power is kept ON,


ensure opening of suction valve,
2 discharge valve is in Close.
Recirculation valve full open, Balance leak-off line
Open status in stand by mode

In standby mode if any running pump trips then pump in standby will Manually started, ensure that
3 there is no passing through NRV and tripped pump not rotating in reverse direction.

4 If pump tripped or stopped is rotating in reverse made the discharge valve fully close.

For normal changeover close the discharge valve of boiler feed pump to be started. Ensure
5 recirculation valve is full open, Balance leak-off valves full open

6 Ask the site operator to check the boiler feed pump locally, and check Line-up.

7 Ensure Boiler Feed Pump Start Permissive in DCS

8 Switch ON the boiler feed pump and watch the current and check the pump locally.
If there is no abnormality then open the discharge valve of boiler feed pump watch the current, heater
9 level, Drum level and feed water flow.

10 After the feed pump discharge valve is open.

11 Switch off the respective boiler feed pump, and ensure that there is no reverse rotation

12 If the permit is to be issued then keep the discharge valve in closed position make the power off.

If complete isolation is required then suction valve can be closed, recirculation to be closed, Balance
13 leak off line Closed

If the pump is to be kept in standby mode, discharge valve to be made close and the pump to be kept
14 in standby mode.

15 All permissive for Manual start to be made healthy.

Date

CHECKED BY:

04.12.2017

VERIFIED BY:

CHECKED BY:

11.12.2017
VERIFIED BY:

CHECKED BY:

04.12.2017

VERIFIED BY:
CHECKED BY:

18.12.2017
VERIFIED BY:

CHECKED BY:

25.12.2017

VERIFIED BY:
IN-CHARGE IN SHIFT

Sheduled Date for the Month 04.12.2017


AFBC-1 AFBC-2
BFP Starting/Changeover BFP No. BFP No.
Change Over Date

ACTIVITY DESCRIPTION OK NOK OK

er Feed Pump to be taken in service is not under any type of work permit, and
is available

by mode electrical power is kept ON,


of suction valve,
e is in Close.
lve full open, Balance leak-off line
stand by mode

e if any running pump trips then pump in standby will Manually started, ensure that .
ing through NRV and tripped pump not rotating in reverse direction.

or stopped is rotating in reverse made the discharge valve fully close.

ngeover close the discharge valve of boiler feed pump to be started. Ensure
ve is full open, Balance leak-off valves full open

rator to check the boiler feed pump locally, and check Line-up.

eed Pump Start Permissive in DCS

boiler feed pump and watch the current and check the pump locally.
normality then open the discharge valve of boiler feed pump watch the current, heater
el and feed water flow.

ump discharge valve is open.

espective boiler feed pump, and ensure that there is no reverse rotation

o be issued then keep the discharge valve in closed position make the power off.

ation is required then suction valve can be closed, recirculation to be closed, Balance
sed

be kept in standby mode, discharge valve to be made close and the pump to be kept
e.

or Manual start to be made healthy.

Remark If An
CHECK LIST FOR

04.12.2017 11.12.2017
AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2
BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK

. . . . .
Remark If Any Remark If Any
CHECK LIST FOR STARTING /CHANGEOVER OF BFP PH#1

11.12.2017 04.12.2017
WHRB-1 WHRB-2 AFBC-1 AFBC-2 WHRB-1
BFP No. BFP No. BFP No. BFP No. BFP No.

OK NOK OK NOK OK NOK OK NOK OK

. . . .
Remark If Any Remark If Any
.2017 18.12.2017
WHRB-1 WHRB-2 AFBC-1 AFBC-2 WHRB-1
BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK

. . . . .
k If Any Remark If Any
25.12.2017
WHRB-2 AFBC-1 AFBC-2 WHRB-1 WHRB-2
BFP No. BFP No. BFP No. BFP No. BFP No.

OK NOK OK NOK OK NOK OK NOK OK

. . . .
Remark If Any
WHRB-2

NOK

.
OWNER IN-CHARGE IN SHIFT
Sheduled Date for the Month

BFP Starting/Changeover
Change Over Date

STEP ACTIVITY DESCRIPTION

Ensure that Boiler Feed Pump to be taken in service is not under any type of work permit, and
1 electrical power is available

In case of standby mode electrical power is kept ON,


ensure opening of suction valve,
2 discharge valve is in Close.
Recirculation valve full open, Balance leak-off line
Open status in stand by mode

In standby mode if any running pump trips then pump in standby will Manually started, ensure that
3 there is no passing through NRV and tripped pump not rotating in reverse direction.

4 If pump tripped or stopped is rotating in reverse made the discharge valve fully close.

For normal changeover close the discharge valve of boiler feed pump to be started. Ensure
5 recirculation valve is full open, Balance leak-off valves full open

6 Ask the site operator to check the boiler feed pump locally, and check Line-up.

7 Ensure Boiler Feed Pump Start Permissive in DCS

8 Switch ON the boiler feed pump and watch the current and check the pump locally.

If there is no abnormality then open the discharge valve of boiler feed pump watch the current, heater
9 level, Drum level and feed water flow.

10 After the feed pump discharge valve is open.

11 Switch off the respective boiler feed pump, and ensure that there is no reverse rotation

12 If the permit is to be issued then keep the discharge valve in closed position make the power off.

If complete isolation is required then suction valve can be closed, recirculation to be closed, Balance
13 leak off line Closed
If the pump is to be kept in standby mode, discharge valve to be made close and the pump to be kept
14 in standby mode.
15 All permissive for Manual start to be made healthy.

Date

CHECKED BY:

VERIFIED BY:

CHECKED BY:

VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

VERIFIED BY:
IN-CHARGE IN SHIFT
Sheduled Date for the Month 04.12.2017
AFBC-1 AFBC-2
BFP Starting/Changeover BFP No. BFP No.
Change Over Date

ACTIVITY DESCRIPTION OK NOK OK

er Feed Pump to be taken in service is not under any type of work permit, and
is available

by mode electrical power is kept ON,


of suction valve,
e is in Close.
lve full open, Balance leak-off line
stand by mode

e if any running pump trips then pump in standby will Manually started, ensure that .
ing through NRV and tripped pump not rotating in reverse direction.

or stopped is rotating in reverse made the discharge valve fully close.

ngeover close the discharge valve of boiler feed pump to be started. Ensure
ve is full open, Balance leak-off valves full open

rator to check the boiler feed pump locally, and check Line-up.

eed Pump Start Permissive in DCS

boiler feed pump and watch the current and check the pump locally.

normality then open the discharge valve of boiler feed pump watch the current, heater
el and feed water flow.

ump discharge valve is open.

espective boiler feed pump, and ensure that there is no reverse rotation

o be issued then keep the discharge valve in closed position make the power off.

ation is required then suction valve can be closed, recirculation to be closed, Balance
sed
be kept in standby mode, discharge valve to be made close and the pump to be kept
e.
or Manual start to be made healthy.

Remark If Any
CHECK LIST FOR STARTING /CHANG

04.12.2017 11.12.2017
AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2 WHRB-1
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
STARTING /CHANGEOVER OF BFP PH#1

04.12.2017
WHRB-2 AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1
BFP No. BFP No. BFP No. BFP No. BFP No. BFP No.

OK NOK OK NOK OK NOK OK NOK OK NOK OK

. . . . .
Remark If Any
18.12.2017 25.12.2017
AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
25.12.2017
WHRB-1 WHRB-2
BFP No. BFP No.

OK NOK OK NOK

. .
Remark If Any
OWNER IN-CHARGE IN SHIFT
Sheduled Date for the Month

BFP Starting/Changeover
Change Over Date

STEP ACTIVITY DESCRIPTION

Ensure that Boiler Feed Pump to be taken in service is not under any type of work permit, and
1 electrical power is available

In case of standby mode electrical power is kept ON,


ensure opening of suction valve,
2 discharge valve is in Close.
Recirculation valve full open, Balance leak-off line
Open status in stand by mode

In standby mode if any running pump trips then pump in standby will Manually started, ensure that
3 there is no passing through NRV and tripped pump not rotating in reverse direction.

4 If pump tripped or stopped is rotating in reverse made the discharge valve fully close.

For normal changeover close the discharge valve of boiler feed pump to be started. Ensure
5 recirculation valve is full open, Balance leak-off valves full open

6 Ask the site operator to check the boiler feed pump locally, and check Line-up.

7 Ensure Boiler Feed Pump Start Permissive in DCS

8 Switch ON the boiler feed pump and watch the current and check the pump locally.

If there is no abnormality then open the discharge valve of boiler feed pump watch the current, heater
9 level, Drum level and feed water flow.

10 After the feed pump discharge valve is open.

11 Switch off the respective boiler feed pump, and ensure that there is no reverse rotation

12 If the permit is to be issued then keep the discharge valve in closed position make the power off.

If complete isolation is required then suction valve can be closed, recirculation to be closed, Balance
13 leak off line Closed
If the pump is to be kept in standby mode, discharge valve to be made close and the pump to be kept
14 in standby mode.
15 All permissive for Manual start to be made healthy.

Date

CHECKED BY:

VERIFIED BY:

CHECKED BY:

VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

VERIFIED BY:
IN-CHARGE IN SHIFT
Sheduled Date for the Month 04.12.2017
AFBC-1 AFBC-2
BFP Starting/Changeover BFP No. BFP No.
Change Over Date

ACTIVITY DESCRIPTION OK NOK OK

er Feed Pump to be taken in service is not under any type of work permit, and
is available

by mode electrical power is kept ON,


of suction valve,
e is in Close.
lve full open, Balance leak-off line
stand by mode

e if any running pump trips then pump in standby will Manually started, ensure that .
ing through NRV and tripped pump not rotating in reverse direction.

or stopped is rotating in reverse made the discharge valve fully close.

ngeover close the discharge valve of boiler feed pump to be started. Ensure
ve is full open, Balance leak-off valves full open

rator to check the boiler feed pump locally, and check Line-up.

eed Pump Start Permissive in DCS

boiler feed pump and watch the current and check the pump locally.

normality then open the discharge valve of boiler feed pump watch the current, heater
el and feed water flow.

ump discharge valve is open.

espective boiler feed pump, and ensure that there is no reverse rotation

o be issued then keep the discharge valve in closed position make the power off.

ation is required then suction valve can be closed, recirculation to be closed, Balance
sed
be kept in standby mode, discharge valve to be made close and the pump to be kept
e.
or Manual start to be made healthy.

Remark If Any
CHECK LIST FOR STARTING /CHANG

04.12.2017 11.12.2017
AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2 WHRB-1
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
STARTING /CHANGEOVER OF BFP PH#1

04.12.2017
WHRB-2 AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1
BFP No. BFP No. BFP No. BFP No. BFP No. BFP No.

OK NOK OK NOK OK NOK OK NOK OK NOK OK

. . . . .
Remark If Any
18.12.2017 25.12.2017
AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
25.12.2017
WHRB-1 WHRB-2
BFP No. BFP No.

OK NOK OK NOK

. .
Remark If Any
OWNER IN-CHARGE IN SHIFT
Sheduled Date for the Month

BFP Starting/Changeover
Change Over Date

STEP ACTIVITY DESCRIPTION

Ensure that Boiler Feed Pump to be taken in service is not under any type of work permit, and
1 electrical power is available

In case of standby mode electrical power is kept ON,


ensure opening of suction valve,
2 discharge valve is in Close.
Recirculation valve full open, Balance leak-off line
Open status in stand by mode

In standby mode if any running pump trips then pump in standby will Manually started, ensure that
3 there is no passing through NRV and tripped pump not rotating in reverse direction.

4 If pump tripped or stopped is rotating in reverse made the discharge valve fully close.

For normal changeover close the discharge valve of boiler feed pump to be started. Ensure
5 recirculation valve is full open, Balance leak-off valves full open

6 Ask the site operator to check the boiler feed pump locally, and check Line-up.

7 Ensure Boiler Feed Pump Start Permissive in DCS

8 Switch ON the boiler feed pump and watch the current and check the pump locally.

If there is no abnormality then open the discharge valve of boiler feed pump watch the current, heater
9 level, Drum level and feed water flow.

10 After the feed pump discharge valve is open.

11 Switch off the respective boiler feed pump, and ensure that there is no reverse rotation

12 If the permit is to be issued then keep the discharge valve in closed position make the power off.

If complete isolation is required then suction valve can be closed, recirculation to be closed, Balance
13 leak off line Closed
If the pump is to be kept in standby mode, discharge valve to be made close and the pump to be kept
14 in standby mode.
15 All permissive for Manual start to be made healthy.

Date

CHECKED BY:

VERIFIED BY:

CHECKED BY:

VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

VERIFIED BY:
IN-CHARGE IN SHIFT
Sheduled Date for the Month 04.12.2017
AFBC-1 AFBC-2
BFP Starting/Changeover BFP No. BFP No.
Change Over Date

ACTIVITY DESCRIPTION OK NOK OK

er Feed Pump to be taken in service is not under any type of work permit, and
is available

by mode electrical power is kept ON,


of suction valve,
e is in Close.
lve full open, Balance leak-off line
stand by mode

e if any running pump trips then pump in standby will Manually started, ensure that .
ing through NRV and tripped pump not rotating in reverse direction.

or stopped is rotating in reverse made the discharge valve fully close.

ngeover close the discharge valve of boiler feed pump to be started. Ensure
ve is full open, Balance leak-off valves full open

rator to check the boiler feed pump locally, and check Line-up.

eed Pump Start Permissive in DCS

boiler feed pump and watch the current and check the pump locally.

normality then open the discharge valve of boiler feed pump watch the current, heater
el and feed water flow.

ump discharge valve is open.

espective boiler feed pump, and ensure that there is no reverse rotation

o be issued then keep the discharge valve in closed position make the power off.

ation is required then suction valve can be closed, recirculation to be closed, Balance
sed
be kept in standby mode, discharge valve to be made close and the pump to be kept
e.
or Manual start to be made healthy.

Remark If Any
CHECK LIST FOR STARTING /CHANG

04.12.2017 11.12.2017
AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2 WHRB-1
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
STARTING /CHANGEOVER OF BFP PH#1

04.12.2017
WHRB-2 AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1
BFP No. BFP No. BFP No. BFP No. BFP No. BFP No.

OK NOK OK NOK OK NOK OK NOK OK NOK OK

. . . . .
Remark If Any
18.12.2017 25.12.2017
AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
25.12.2017
WHRB-1 WHRB-2
BFP No. BFP No.

OK NOK OK NOK

. .
Remark If Any
OWNER IN-CHARGE IN SHIFT
Sheduled Date for the Month

BFP Starting/Changeover
Change Over Date

STEP ACTIVITY DESCRIPTION

Ensure that Boiler Feed Pump to be taken in service is not under any type of work permit, and
1 electrical power is available

In case of standby mode electrical power is kept ON,


ensure opening of suction valve,
2 discharge valve is in Close.
Recirculation valve full open, Balance leak-off line
Open status in stand by mode

In standby mode if any running pump trips then pump in standby will Manually started, ensure that
3 there is no passing through NRV and tripped pump not rotating in reverse direction.

4 If pump tripped or stopped is rotating in reverse made the discharge valve fully close.

For normal changeover close the discharge valve of boiler feed pump to be started. Ensure
5 recirculation valve is full open, Balance leak-off valves full open

6 Ask the site operator to check the boiler feed pump locally, and check Line-up.

7 Ensure Boiler Feed Pump Start Permissive in DCS

8 Switch ON the boiler feed pump and watch the current and check the pump locally.

If there is no abnormality then open the discharge valve of boiler feed pump watch the current, heater
9 level, Drum level and feed water flow.

10 After the feed pump discharge valve is open.

11 Switch off the respective boiler feed pump, and ensure that there is no reverse rotation

12 If the permit is to be issued then keep the discharge valve in closed position make the power off.

If complete isolation is required then suction valve can be closed, recirculation to be closed, Balance
13 leak off line Closed
If the pump is to be kept in standby mode, discharge valve to be made close and the pump to be kept
14 in standby mode.
15 All permissive for Manual start to be made healthy.

Date

CHECKED BY:

VERIFIED BY:

CHECKED BY:

VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

VERIFIED BY:
IN-CHARGE IN SHIFT
Sheduled Date for the Month 04.12.2017
AFBC-1 AFBC-2
BFP Starting/Changeover BFP No. BFP No.
Change Over Date

ACTIVITY DESCRIPTION OK NOK OK

er Feed Pump to be taken in service is not under any type of work permit, and
is available

by mode electrical power is kept ON,


of suction valve,
e is in Close.
lve full open, Balance leak-off line
stand by mode

e if any running pump trips then pump in standby will Manually started, ensure that .
ing through NRV and tripped pump not rotating in reverse direction.

or stopped is rotating in reverse made the discharge valve fully close.

ngeover close the discharge valve of boiler feed pump to be started. Ensure
ve is full open, Balance leak-off valves full open

rator to check the boiler feed pump locally, and check Line-up.

eed Pump Start Permissive in DCS

boiler feed pump and watch the current and check the pump locally.

normality then open the discharge valve of boiler feed pump watch the current, heater
el and feed water flow.

ump discharge valve is open.

espective boiler feed pump, and ensure that there is no reverse rotation

o be issued then keep the discharge valve in closed position make the power off.

ation is required then suction valve can be closed, recirculation to be closed, Balance
sed
be kept in standby mode, discharge valve to be made close and the pump to be kept
e.
or Manual start to be made healthy.

Remark If Any
CHECK LIST FOR STARTING /CHANG

04.12.2017 11.12.2017
AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2 WHRB-1
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
STARTING /CHANGEOVER OF BFP PH#1

04.12.2017
WHRB-2 AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1
BFP No. BFP No. BFP No. BFP No. BFP No. BFP No.

OK NOK OK NOK OK NOK OK NOK OK NOK OK

. . . . .
Remark If Any
18.12.2017 25.12.2017
AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
25.12.2017
WHRB-1 WHRB-2
BFP No. BFP No.

OK NOK OK NOK

. .
Remark If Any
OWNER IN-CHARGE IN SHIFT
Sheduled Date for the Month

BFP Starting/Changeover
Change Over Date

STEP ACTIVITY DESCRIPTION

Ensure that Boiler Feed Pump to be taken in service is not under any type of work permit, and
1 electrical power is available

In case of standby mode electrical power is kept ON,


ensure opening of suction valve,
2 discharge valve is in Close.
Recirculation valve full open, Balance leak-off line
Open status in stand by mode

In standby mode if any running pump trips then pump in standby will Manually started, ensure that
3 there is no passing through NRV and tripped pump not rotating in reverse direction.

4 If pump tripped or stopped is rotating in reverse made the discharge valve fully close.

For normal changeover close the discharge valve of boiler feed pump to be started. Ensure
5 recirculation valve is full open, Balance leak-off valves full open

6 Ask the site operator to check the boiler feed pump locally, and check Line-up.

7 Ensure Boiler Feed Pump Start Permissive in DCS

8 Switch ON the boiler feed pump and watch the current and check the pump locally.

If there is no abnormality then open the discharge valve of boiler feed pump watch the current, heater
9 level, Drum level and feed water flow.

10 After the feed pump discharge valve is open.

11 Switch off the respective boiler feed pump, and ensure that there is no reverse rotation

12 If the permit is to be issued then keep the discharge valve in closed position make the power off.

If complete isolation is required then suction valve can be closed, recirculation to be closed, Balance
13 leak off line Closed
If the pump is to be kept in standby mode, discharge valve to be made close and the pump to be kept
14 in standby mode.
15 All permissive for Manual start to be made healthy.

Date

CHECKED BY:

VERIFIED BY:

CHECKED BY:

VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

0
VERIFIED BY:

CHECKED BY:

VERIFIED BY:
IN-CHARGE IN SHIFT
Sheduled Date for the Month 04.12.2017
AFBC-1 AFBC-2
BFP Starting/Changeover BFP No. BFP No.
Change Over Date

ACTIVITY DESCRIPTION OK NOK OK

er Feed Pump to be taken in service is not under any type of work permit, and
is available

by mode electrical power is kept ON,


of suction valve,
e is in Close.
lve full open, Balance leak-off line
stand by mode

e if any running pump trips then pump in standby will Manually started, ensure that .
ing through NRV and tripped pump not rotating in reverse direction.

or stopped is rotating in reverse made the discharge valve fully close.

ngeover close the discharge valve of boiler feed pump to be started. Ensure
ve is full open, Balance leak-off valves full open

rator to check the boiler feed pump locally, and check Line-up.

eed Pump Start Permissive in DCS

boiler feed pump and watch the current and check the pump locally.

normality then open the discharge valve of boiler feed pump watch the current, heater
el and feed water flow.

ump discharge valve is open.

espective boiler feed pump, and ensure that there is no reverse rotation

o be issued then keep the discharge valve in closed position make the power off.

ation is required then suction valve can be closed, recirculation to be closed, Balance
sed
be kept in standby mode, discharge valve to be made close and the pump to be kept
e.
or Manual start to be made healthy.

Remark If Any
CHECK LIST FOR STARTING /CHANG

04.12.2017 11.12.2017
AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2 WHRB-1
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
STARTING /CHANGEOVER OF BFP PH#1

04.12.2017
WHRB-2 AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1
BFP No. BFP No. BFP No. BFP No. BFP No. BFP No.

OK NOK OK NOK OK NOK OK NOK OK NOK OK

. . . . .
Remark If Any
18.12.2017 25.12.2017
AFBC-1 AFBC-2 WHRB-1 WHRB-2 AFBC-1 AFBC-2
BFP No. BFP No. BFP No. BFP No. BFP No.

NOK OK NOK OK NOK OK NOK OK NOK OK NOK

. . . . . .
Remark If Any Remark If Any
25.12.2017
WHRB-1 WHRB-2
BFP No. BFP No.

OK NOK OK NOK

. .
Remark If Any