Professional Documents
Culture Documents
= H-TYPE
(S+7)BLDG
FOR H-TYPE (S+7) BLDG FOR LAUKIK DEVELOPERS
LAUKIK AT RAMCHANDRANAGAR-KALYAN
DEVELOP LOADING ANALYSIS
ERS
Description Thk Density Loading
Sr No
(mm) (T/cum) (T/sqm)
1 Floor Slab
1.1 Self Weight 125 2.5 0.313
1.2 Ceiling Plaster 12 2.08 0.025
1.3 Tiling 23 2.2 0.051
1.4 CM finish 21 2.32 0.049
1.5 Live Load 0.2
Total 0.637
Say 0.650
2 Roof Slab
2.1 Self Weight 125 2.5 0.313
2.2 Ceiling Plaster 12 2.08 0.025
2.3 CM finish 25 2.08 0.052
2.4 Brick Bat Coba 100 1.95 0.195
2.5 Live Load 0.15
Total 0.734
Say 0.750
3 Common Corridor / Balconies
3.1 Self Weight 125 2.5 0.313
3.2 Ceiling Plaster 12 2.08 0.025
3.3 CM finish 25 2.08 0.052
3.4 Tiling 23 2.2 0.051
3.5 Live Load 0.3
Total 0.740
Say 0.750
5 WC Slab
sunk 600
5.1 Self Weight 100 2.5 0.250
5.2 Ceiling plaster 12 2.08 0.025
5.2 WP Plaster 25 2.08 0.052
5.3 Brick Bat Coba 550 1.95 1.073
5.4 CM finish 25 2.08 0.052
5.5 Tiling 25 2.2 0.055
5.6 Live Load 0.2
Total 1.706
Say 1.710
6 Bath Slab
sunk 250
6.1 Self Weight 100 2.5 0.250
6.2 Ceiling plaster 12 2.08 0.025
6.3 WP Plaster 25 2.08 0.052
6.4 Brick Bat Coba 200 1.95 0.390
6.5 CM finish 25 2.08 0.052
6.6 Tiling 25 2.2 0.055
6.7 Live Load 0.2
Total 1.024
Say 1.030
7 Stair Case
Tread 250 mm
Rise 161.66 mm
Angle of Flight 36
7.1 Self Weight 150 2.5 0.464
7.2 Self wt. Of Steps 0.202
7.3 Ceiling plaster 12 2.08 0.025
7.4 CM finish 25 2.08 0.052
7.5 Tiling 25 2.2 0.055
7.6 Live Load 0.300
Total 1.098
Say 1.200
D:\NJG\B-TYPE\MCROOM\LOADING ANALYSIS.XLS 4/24/2003 11:42 A.M
LOADING ANALYSIS FOR M/C ROOM & WATER TANK FOR B -TYPE
M/C ROOM
THK DENSITY
WATER TANK
ROOF BEAMS
AT EXTERNAL FACE WIDTH DEPTH DENSITY UDL
ROOF BEAMS
AT INTERNAL FACE WIDTH DEPTH DENSITY UDL
SOFFIT BEAMS
FOR WALL BEAM WIDTH DEPTH DENSITY UDL
SOFFIT BEAMS
FOR WALL+ BEAM WIDTH DEPTH DENSITY UDL
SOFFIT BEAMS
FOR WALL+ BEAM WIDTH DEPTH DENSITY UDL
SOFFIT BEAMS
FOR WALL+ BEAM WIDTH DEPTH DENSITY UDL
LOADING ANALYSIS
PROJECT :
PARAMETERS:=
Type of Soil Site 2
( 1- Hard Soil , 2 - Medium Soil , 3 - Soft Soil )
Type of Structure 3
( 1- RC Str , 2 - Steel Str , 3 - All other )
Where,
Ah Design horizonal Seismic Coefficent
FOR ALL OTHER BUILDING INCLUDING MOMENT RESISTING FRAME BUILDING WITH BRICK INFILL PANELS
Ahx = Z x I x Sa Ahz = Z x I x Sa
2x Rxg 2x Rxg
PARAMETERS:=
Pz = 0.6 x VZ2
Vz = Vb x K1 x K2 x K3
Where,
Pz Design Wind Pressure in N/m2 at height z
VZ = Vb x K1 x K2 x K3
VZ = #VALUE! m/sec
Pz = 0.6 x VZ2
Pz = #VALUE! N/m2
Pz = #VALUE! Kg/m2
Pz = #VALUE! T/m2