Data Sheet : Induction Motor

s Champion Series
Motor Type : 1LA2 130-4NA80
Number of Phases 3
Rated Output kW 5.5
Rated Voltage V 415
Rated Current A 10 Reference Standard IS:12615
Rated Speed rev/min 1456 Enclosure IS:4691 IP55
Rated Frequency Hz 50 Cooling IS:6362 IC411
Rated Torque 3.7 kgf.m / 36 Nm Duty S1
100% load % 89.6 Type 1XB0 132
Efficiency : 75% load % 89.6 Terminal Terminal Size M5
50% load % 88.6 Box No. of Terminals 6
100% load % 0.82 Data Max. Cable
Power Factor : 75% load % 0.76 Section mm 2R 3C 16mm
50% load % 0.64 Drive End 6208ZZ
Insulation Class F Non-Drive End 6208ZZ
Bearing
Temperature rise (Res.method) K 70
Data
Lubrication Pre-Lubricated
Life L10 hrs. # 50,000
Locked rotor Hot (s) 7 Lifting eyebolt IS:4190 M10
withstand time Cold (s) 15 Motor weight (approx.) kg 60
Stator connection DELTA GD (4x MI) kgf.m 0.0811
Rotor
Rotor Class KL16 Weight kg 24
Construction IS:2253 IMB3
Ratio of starting
current to the 100% voltage 6.5 Frame designation 132S
rated current 80% voltage 4.8
Ambient Temperature C 50
Ratio of starting Voltage Variation % 10
torque to the 100% voltage 2.7 Frequency variation % 5
rated torque 80% voltage 1.5 Combined Voltage &
Frequency variation % 10
Ratio of Breakdown # For directly coupled drives
torque to the 100% voltage 3.1
rated torque 80% voltage 1.8 Data subject to tolerance as per IS:12615.

Remarks : Unique Identification Code: UIC-7506589 <--- This code must match with the one on Characteristic Curves Sheet.

KALWA, INDIA Reference Document Printed & Checked : Release Date


Department : I DT LD P LV-Motors MTR 2.6-182 Date : 14.12.2012 Aug '2011
Format Reference No.: MTR 7.1-006

Program Name:Documentation_Program_IE_V3_2R
s Characteristic Curves
Unique Identification Code: UIC-7506589 <--- This code must match with the one on the Data Sheet.

Motor Type : 1LA2 130-4NA80 Voltage : 415V Rated Speed : 1456 rev/min
Output : 5.5 kW Frequency : 50Hz Rated Torque : 3.7 kgf.m / 36 Nm
Rated Current: 10A

% Load FL FL FL Locked Rtr Curr 6.5 x Rated


Efficiency 89.6% 89.6% 88.6% LRWT HOT 7s
Power Factor 0.82 0.76 0.64 LRWT COLD 15 s

D A T A S U B J E C T T O T O L E R A N C E A S P E R I S : 1 2 6 1 5.

Efficiency & PF Curves Current Vs Load Curve

1 12
0.9 10
0.8
8

Current in A
0.7
Eff, PF

6
0.6
4
0.5
0.4 2

0.3 0
40 50 60 70 80 90 100 40 50 60 70 80 90 100
Load (% of rated output) Load (% of rated output)

Effy PF Current

Values other than those at FL, FL and FL are only indicative. Do not extrapolate to No-load.

Speed Torque Curve Locked Rotor Withstand Curve


[Applicable for operation of motors on Grid Supply only.] [Applicable for operation of motors on Grid Supply only.]

350 100000

300
10000
250
Torque (% of rated)

200 1000
Time (s)

150
100
100

50 10

0
0 20 40 60 80 100 1
0 1 2 3 4 5 6 7
Speed (% of synchronous)
Current (times the rated)

Torque at 100%Vr Torque at 80% Vr Hot Cold

KALWA, INDIA Reference Document Printed & Checked : Release Date


Department : I DT LD P LV-Motors MTR 2.6-182 Date : 14.12.2012 Aug '2011

Program Name: Documentation_Program_IE_V3_2R