You are on page 1of 2

STANDING SEAM

METAL ROOFING

DOUBLE-LOK ®

The Double-Lok® roof panel is a mechanically field-seamed, trapezoidal leg standing seam roof system. Double-Lok® panels are
available in 12-inch, 18-inch and 24-inch widths. Double-Lok® requires a minimum slope of ¼:12. Double-Lok® panels are ideal
for industrial, commercial and architectural applications.

Features and Benefits:


• D
 esigned to cope with the forces of expansion and contraction. This is accomplished
by allowing the panels to freely move up and down the roof slope.
• 2
 ” and 4” sliding clips are available in high and low versions, which allow thermal
movement on a wide variety of building widths.
• N
 umerous UL 580 Construction rating are available, as well as UL 790, Class A for
external fire, numerous roof assemblies for UL 263 for internal fire and the UL 2218
Class 418"impact rating.
12"
• D
 ouble-Lok® carries FM, Florida approval and Dade County ratings.
3"

7 ³⁄₈" Product Specifications • Gauges: 24 and 22

• Applications: Roof • Finishes: Smooth (standard); Embossed


18" (optional)
• C
 overage Widths: 12”, 18”, 24”
3" • Coatings: Galvalume Plus®, Signature® 200,
• M
 inimum Slope: ¼:12
Signature® 300, Signature® 300 Metallic
13 ³⁄₈" • P
 anel Attachment: Concealed Fastening
System; Low, High, and 2” Stand Off
Sliding Clips
24"

3"

19 ³⁄₈"

www.mbci.com | shop.mbci.com
HOUSTON | 281.407.6915 ENNIS, TX | 4
​ 69.256.8255 MEMPHIS, TN | 6
​ 62.298.2337 ROME, NY | 315.371.4330
ADEL, GA | 8
​ 88.514.6062 INDIANAPOLIS | 3 ​ 17.364.4329 OKLAHOMA CITY | 405.492.6968 SALT LAKE CITY | 385.715.2952
ATLANTA | 678.337.1619 LUBBOCK, TX | 8 ​ 06.224.2724 PHOENIX | 480.630.3022 SAN ANTONIO | 210.888.9768
ATWATER, CA | 209.445.3891
05-17
STANDING SEAM METAL ROOFING
DOUBLE-LOK ®

CATEGORY CHARACTERISTIC TEST METHOD PURPOSE RESULT


Determines the air leakage
0.013 cfm/ft2 at 6.24 psf static pressure
Air Leakage Through Roof characteristics of metal roof panels
ASTM E1680 0.020 cfm/ft2 at 12.00 psf static
Panel Joints under specified air pressure differences
pressure
at ambient conditions

ENVIRONMENTAL Water Penetration


Determines the resistance to water No uncontrolled water penetration
ASTM E1646 penetration of metal roof panels under through the panel joints at a static
Through Roof Panel Joints
uniform static air pressure difference pressure of 12.00 psf
Determines Impact Resistance of
Impact Resistance UL 2218 Class 4 Rating
prepared Roof Covering Materials
Standard for Standard Test Methods for
Room Fire Performance UL 790 See Class A Fire Rating Data Sheet
Fire Tests of Roof Coverings

FIRE RESISTANCE For use in Design Nos. P225, P227,


Standard for Fire Tests of Building P230, P237, P265, P268, P508, P510,
Room Fire Performance UL 263
Construction and Materials P512, P701, P711, P720, P722, P726,
P731, P734, P801, P815, P819.
Provides a standard procedure
to evaluate or confirm structural
Uplift Resistance ASTM E 1592 See Load Chart Section
performance under uniform static air
STRUCTURAL pressure difference
North American Specification for the
See Section Properties and Allowable
Gravity Loads AISI S100 Design of Cold-Formed Steel Structural
Load Table Section
Members
Roof Performance Sets performance standards for panel
FM 4471 See FM Engineering Tech Bulletin
FM Global roofs including uplift resistance
Roof Performance Determines the uplift resistance of roof Class 90 Rating - Construction Number
Underwriters UL 580 assemblies consisting of the roof and 165, 180C, 287, 308A, 450, 538, 539 and
Laboratories roof coverings materials 540.
The Product Control Approval System
establishes a protocol to evaluate
the standards of products used in
construction in Miami-Dade County.
Miami-Dade County, with its inclusion
in the High Velocity Hurricane Zone
TAS 125
(HVHZ) has the most stringent code
Roof Performance TAS 201
ROOF LISTINGS requirements of the Florida Building See NOA # 13-0425.14
Miami-Dade County TAS 100
Code. Therefore, all products that
FM 4471 App. G
comprise the structure’s building
envelope — doors, shutters, windows,
prefabricated buildings and truss plates
— require the issuance of an approval
in order to be used for construction in
Miami-Dade County
Florida product approval is the approval
of products and systems, which
ASTM E 1592
Roof Performance comprise the building envelope and
FM 4471 See FL# 11819.2
Florida Approval structural frame, for compliance with the
UL 790
structural requirements of the Florida
Building Code.

Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the
right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our
website at www.mbci.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should
be designed to conform to applicable building codes, regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings
will take precedence. MBCI’s insulated metal panel product line is manufactured by Metl-Span ®. 05-17

You might also like