You are on page 1of 50

CONSTRUCTION OF RE-DESIGNED NIP BUILDING TO ACCOMMODATE THE DOCUMENT PROCESSING CENTRE (DPC)

UGANDA REVENUE AUTHORITY NAKAWA


BILL No. G-1
DESCRIPTION: GENERAL ITEMS

ITEM NO. ITEM DESCRIPTION UNIT QTY UNIT RATE


USHS

Contractual Requirements
A110.1 Performance Security Clause sum 1
A110.2
A110.3 Insurance of works sum 1
A110.4
A110.5 Insurance of Contractors Equipment sum 1

Site Offices and Housing


A211.1 Establishment and removal of offices for sum 1
the Engineer's staf

Testing of Materials
A211.2 Concrete works test cubes, steel test, item 1
Iron sheet, blocks sand and aggregates
and others specified during execution of
works

A211.3 steel, Iron sheet, blocks sand and sum 1


aggregates

Temporary Works
A211.4 Establishment & removal of site sign- nr 1
boards

Total for General Item Carried to Collection


CESSING CENTRE (DPC)

AMOUNT
USHS

0.00
CONSTRUCTION OF RE-DESIGNED NIP BUILDING TO ACCOMMODATE THE DOCUMENT PROCESSING CENTRE (DPC)

BILL No. G-2


DESCRIPTION: METHOD RELATED CHARGES

ITEM NO. ITEM DESCRIPTION UNIT QTY UNIT RATE


Ushs

METHOD RELATED CHARGES

G-3.1 Mobilization on site sum 1

G-3.2 Demobilize on completion of the Works sum 1

G-3.3 Supply and/or erect Contractor's site sum 1


offices.

G-3.4 Maintain Contractor's site offices, months 6


including all services

G-3.5 Remove Contractor's site offices on sum 1


completion of the Works

G-3.6 Prepare ''as-built'' or record drawings. sum 1

G-3.7 Allow for demolition of existing 1


structure,salvage usable items and hand
over to client.

In the following pages, may be entered in


accordance with Section 7 of CESMM3.
These must distinguish between fixed
and time related charges.

Provisional Sum

G-3.7 Provideprotective gears like ear mufs, Item 1


dust masks etc.visitors for the workers
and visitors
Total for Method Related Charges Carried to Collection
ENT PROCESSING CENTRE (DPC)

AMOUNT
Ushs
0.00
CONSTRUCTION OF RE-DESIGNED NIP BUILDING TO ACCOMMODATE THE DOCUMENT
CENTRE (DPC)

BILL No. W-1


DESCRIPTION: CIVIL WORKS
Item Description Unit Qty Rate
Structural steel works I-Stanchion Columns
and Beams
DEMOLITION & EXCAVATION OF
FOUNDATION PITS
1 Excavate foundation pits not exceeding 1.50m CM 139
deep starting from stripped/Industrial concrete
for column bases.
2 Cart away surplus excavated material. CM 80
FOUNDATION BLINDING
3 50mm thick plain concrete grade 15 in blinding SM 109
to pad foundation pit bottoms.

CONCRETE TO PAD FOUNDATION /


PLINTH WALL FOOTING
4 Reinforced concrete grade 25 in 450mm CM 43
column bases
5 Ditto in column stubs and strip foundation. CM 16

FORMWORK
Sawn formwork to sides of reinforced
concrete 300-450mm wide in,
6 Column bases. SM 78

7 Column stubs. SM 63

8 Sawn formwork to sides of concrete in lm 162


foundation wall footing not exceeding 300mm
wide.
Reinforcements
Fix High tensile reinforcements in column
stubs and column bases , including tying
wire,spacers, bends, overlaps, hooks and all
the necessary requirements used in the fixing
of bars;

9 T20 KG 2,000
10 T16 KG 4,530
11 T12 KG 3,300

12 T8 KG 4,500
DPM
13 1000 gauge polythene damp proof membrane. SM 864

GROUND FLOOR REINFORCED


CONCRETE BEAMS AND SLAB INCLUDE
200MM THICK HARD CORE BEFORE
PLACING CONCRETE GRADE 25 FOR
THE SLAB

14 400x230mm thick reinforced concrete grade 25 CM 32


ground floor beam.

15 150mm thick reinforced concrete grade 25 slab. CM 119

FORMWORK

16 Sawn formwork to the sides of the ground floor SM 864


beams 400mm wide and suspended slab. The
form to be inform of steel iron sheet as shown
in the drawing include all cutting fixing and
removal .

17 Sawn formwork not exceeding 300mm wide to lm 600


edges of slab 150 -225mm

STEEL WORKS
18 600X400x10mm thick,2No.mild steel Base NO. 45
plates at the bottom of the ms stanchion UB
columns with 4No 16mm diameter holes(m/s).

19 Paint to the base plates in three coats with SM 20


specified oil based paint as per Engineer's
designs

20 Drill 16mm dia 4No holes in each base plate NO. 200
for the 25mm dia J bolts (m/s)

21 16mm dia,250mm long J bolts fixed into NO 200


concrete stub columns including heads, nuts and
washers

THICKENISING TO INTERNAL WALLS


22 Extra over 200mm thick slab for thickenissing lm 1,322
below other internal toilet walls size 230mm
wide by 250mm deep with and including
channel in hardcore bed
REINFORCEMENTS

Fix reinforcements in slabs, including tying


wire,spacers, bends, overlaps, hooks and all
the necessary requirements used in the fixing
of bars;
23 T12 upto T16 KG 3,420

24 T8 KG 934

Structural Steel Works

25 254 x 254 x 73 kg/m mild steel I-columns KG 8,760


6000mmlong complete with connections, plates,
bolts, nuts,washers and other fixings onto the
stub Columns.
26 Paint to the the surfaces of mild steel I-columns SM 86
in three coats with specified oil based paint as
per Engineer's designs
27 500x350x10mm .thick No.2 MS plate with NO 120
bolts connecting to UB rafter and UB stanchion
column.

28 Paint to MS pates 700x203.x8mm .thick No.2 M2 87


MS plate with bolts connecting to UB rafter and
UB stanchion column No.3 coats specified oil
based paint

29 Drill 18mm dia holes in 700X203X8mm MS NO 748


plates for the 16mm dia bolts.

30 20mm dia, 300mm long bolts connecting to UB NO 748


rafter and UB stanchion column including heads
nuts and washers

31 356x171x45Kg/m thick MS U-beam (Main KG 7,632


Beam) rafter weighing 45kg/m fixed to I beam
columns with bolts and connecting plates/cleats
and a 5-10mmuniform weld.
32 305x165x40Kg/m thick MS U- beam Kg 6000
(Secondary Beam) rafter weighing 45kg/m
fixed to I beam columns with bolts and
connecting plates/cleats and a 5-10mmuniform
weld.

33 Paint to UB RAFTERS 305x165x40Kg/m SM 500


surface in 3NO.coats with oil based paint as per
Engineer's details
34 Supply and fix 50x50x4mm SHS OVER the UB Lm 3,744
for the framing of the soffit of the suspended
floor slabs to receive iron sheet, including all
connections cutting welding and other
accessories.

Reinforced Concrete Solid Suspended slab


and Ramp From Ground To first Floor

Hardcore filling
Reinforced concrete grade 25 in:-
35 175mm thick suspended solid slab and Ramp CM 151
floor .
36 230mm thick filling compacted with a 5 tonne SM 864
roller and blinded with 50mm thick sand to
receive polythene sheet (measured separately) if
required be determined at the site

Reinforcements
Fix reinforcements in column stubs and
column bases , including tying wire,spacers,
bends, overlaps, hooks and all the necessary
requirements used in the fixing of bars;

37 Bars up to and including T 12 Kg 4,500

Fabric Reinforcement
38 BRC No. A 393 fabric mesh reinforcement and SM 860
DPM in concrete suspended floor area and ramp
slab.

Metallic Galvanized Sheet in Super V Profile


2mm thick over the HS to receive the Concrete
for Slab :-
39 Suspended slab and ramp floor including all the SM 860
edges.
Stair case
Supply and fix 8mm thick mild steel or
chequed plates or equally approved as
specified by the project manager to the stair
case
40 300mm wide Trends with sound proof lm 560
materials on top of the metal steel plate

41 150mm high raisers lm 230

42 Landing SM 22
43 Supply and fix 50x50x4mm SHS for the Lm 155
framing of the soffit of the stair case to receive
the approved treads and raisers plates (MS).

Balustrading
Weldable mild steel
45 20mm diameter x 2mm thick CHSbalustrade lm 89
throughvertical balustrades a 150mm C/C and
finished with spray and paint.

46 50 x 8 x 900mm flat bar vertical baluster lm 89


welded onto base plate anchored into floor slab.

47 25 x 50mm RHS baluster welded to steel base lm 89


plate with anchor bolts embeded into floor slab.

48 60 x 75mm moulded timber handrail in lm 89


Mahogany wood, screwed to 40 x 150 x 6mm
thick flat bar welded onto vertical balusters.
Including varnish finish

WALLING
PRECAST CONCRETE CLASS 25, finished
fair on all exposed surfaces including bedding
and jointing in cement sand (1:3) mortar
including
49 150 x 200mm lintel lm 120

Solid Concrete blockwork load bearing


3.5N/mm2 to BS 6098 jointed and pointed in
cement sand (1:3) mortar : with and including
hoop iron wall ties every alternative course : in
50 200mm Thick walling SM 578
51 150mm Thick walling SM 100

DAMP PROOF COURSE OF BITUMEN


FELT TO B.S 743 Type A with 150mm laps
including cement and sand (1:3 levelling bed

52 200mm Thick walling lm 110


53 150mm Wide lm 45

FINISHES
FLOOR FINISHES
INTERNAL FLOOR FINISHES
CEMENT AND SAND (1:4) SCREEDS :
finished smooth
54 Hack the existing floor (Monolithically applied SM 860
to industrial concrete), floor tiles and apply
40mm Thick floor screed : to receive floor tiles.

600 x 600 x 10mm Thick approved proved


Granito floor tiles : bedded and jointed in
approved adhesive : pointed with approved
coloured grout after screeding (ground and
first floor): to

55 Floor areas SM 1,720


56 100 x 10mm skirting Lm 300

WROT MAHOGANY selected, treated and


kept clean
57 100 x 20mm skirting Lm 150

PREPARE SURFACE AND APPLY ONE


COAT PRIMER, one undercoat and two coats
polyurethane clear varnish: on wooden
surfaces : to
58 Surfaces 100 - 200mm girth Lm 133

WALL FINISHES

INTERNAL WALL FINISHES AND


EXTERNALWALL
INTERNAL LIME PLASTER First coat of
cement lime and sand (1:2:9) : second coat of
cement, lime putty and sand (1:1.6) Steel
trowelled smooth externally apply no lime

60 12mm Thick two coat work to walls,concrete SM 832


slab soffits and slab edges

PAINTING AND DECORATING


PREPARE AND APPLY ONE MIST COAT
AND THREE COATS silk vinyl emulsion
paint internally on: the colour of the paint will
be determined by the client and approved by
the consultant

64 Plastered surfaces SM 832

GLASS PARTITIONS AND MDF Board


WALL PANELLING
12mm Thick glass on and including 100 x
50mm aluminium channels framing plugged
onto wall and floor; 100 x 50mm aluminium
channels joists at 1000mm centers both ways:
to Architect's detailed drawing; in

65 New Partitioning panel 3000mm high overall SM 192


comprising of: 15mm thick MDF Block boards
900mm high; glazed panels 1000mmhigh
middle Top Fixed Panels in 8mm thick
laminated glass and glazing and including
700mm high translucent sticker films fixed to
glass panels; including all Painting and
Decorations to Architects Approval as per
Architect's detail drawing

Ceiling Finishes
66 Supply and fix mineral fibre SM 860
"armstrong"acoustic ceiling panels of approved
material in 600 x 600mm grids complete with
heavy duty T-grids system aluminium framing
and hangers to concrete slab & beams
67 Supply and fix treated cypress or equally SM 865
approved timber pallets ceiling lining attached
to the fully welded and jointed 100x50x 4mm
thick RHS steel members ,welded to the the I
beam sections of the roof trusses including
50mm thick styrofoam insulation sheet between
roofing iron sheets(MS) and timber ceiling

ALUMINIUM WINDOWS
SUPPLY AND FIX purpose made : standard
Aluminium sliding windows including all
frames, , 6mm tinted glass and glazing, louvers
attached on the windows as specified by the
consultant, burglar proofing where required
and all necessary accessories as per Architect's
detailed drawing include window rolling
curtains wihich will be approved by the
consultant and the client and prepair put
undercoats and one finishing coat gloss oil
paint if required

68 (i) 500 x1200mm No 22


(ii) 1200 x1500mm No 4
(iii) 1000 x1500mm No 3
(iv) 1500x15000mm No 5

DOORS
ALUMINIUM DOORS
SUPPLY IMPORTED ALUMINIUM DOORS
lipping all round double swing with vision
glass, inclusive of all its accessories for EACH
DOOR all to the Engineer's design

69 Door D3 Size 900 x 2400mm high (overall) No 8

SUPPLY IMPORTED ALUMINIUM DOORS


lipping all round double swing with no vision
glass, inclusive of all its accessories for EACH
DOOR all to the Engineer's design

70 Door D3 Size 900 x 2400mm high (overall) No 6


METAL WORK
STEEL WINDOWS
SUPPLY AND FIX purpose made : standard
STEEL windows including all frames, iron
mongery, 6mm tinted glass and glazing,
burglar proofing where required and all
necessary accessories as per Architect's
detailed drawing prepair and put undercoats
and one finishing coat gloss oil paint

71 1800mmx2400 No 1
72 900mm x 2400 No 3

TOUCH-UP PRIMER, prepare and apply two


undercoats and one finishing coat gloss oil
paint on:-
73 Burglar proofing SM 100

PREPARE AND APPLY THREE coats


polyurethane clear varnish : in accordance
with manufacturer's instructions : on wood :
to
74 Surfaces 200 - 300mm girth Lm 55
SUPPLY AND INSTALL IMPORTED
ALUMINIAM CURTAIN WALLING the size
of aluminiam curtain walling to range from
600mmx1000 to 600mmx1200mm and to be
aproved by the consult to the test of the client.

75 The size of aluminium curtain walling to range SM 500


from 600mmx1000 to 600mmx1200mm and to
be approved by the consultant to the test of the
client.

76 apply Ritver paint on the external wall wich has SM 702


no curtain walling and the colour to be
determined by the client and consultant

Painting and Decorating


PREPARE AND APPLY ONE MIST COAT
AND THREE COATS silk vinyl emulsion
paint internally on:
77 Plastered surfaces SM 520
300 x 300 x 10mm to 500x500x10mm Thick
approved "granito" floor tiles : bedded and
jointed in approved adhesive : pointed with
approved coloured cement : to

78 (i) Toilet Floors SM 80


(ii) Toilet Walls SM 78

79 supply and install granite on work tops on the SM 76


CBC counters and Number plate counters well
finshed and ready to be used by the client

80 Cover 203 x 203 x 16 kg/m mild steel I- No 30


columns with gypsum boards which should be
like the one in internal audit and licensing

EXTERNAL PLASTER First coat of cement


and sand (1:3) : keep it smooth ready to
receive paint
81 Plastered surfaces SM 720

PREPARE AND APPLY ONE MIST COAT


AND THREE COATS mammoran or ritver
paint externally on:
82 external wall of the external wall SM 720

ELEMENT NO. 1
MECHANICAL INSTALLATION
supply and fix the following
H1 Counter top wash hand basin as Twyfords No No 8
GR4522WH complete with 2 No. tap holes and
chain stay holes

H2 Twyfords classic 10003 white viterous W.C pan No 8


complete including fixing pan to floor cistern to
wall with screws and plugs
H3 Stainless steel kitchen sink S/D S/B size 2000 x No 2
550mm sink mixer pillar cock with overan
swivel outlet 615/041, 40mm chain waste
bricon 365/50 40mm C.P bottle trap
H4 Locally obtained towel rail No 8
H5 Locally obtained mirror size 450 x 600mm high No 4
H6 Allow the provisional sum for sanitary water No 1
pipework installation and sewerage piping,
manholes and other connections up to
septictank ready to be used by the client
H7 Allow the provisional sum for the installation of 1
the water tank stands
H8 Soak pit overall internal size 5000mm diameter No 1
x 7000mm deep comprising rubble stone filling
200mm diameter agricultural clay drain pipe in
trench.
H9 Septic tank overall size 6500 x 3000 x 2700mm No 1
high include septic tank air tight covers

H10 Supply and install light duty manhole covers No 15


size 450 x 600mm
W-1 Carried to Summary
TE THE DOCUMENT PROCESSING

Amount
0
CONSTRUCTION OF RE-DESIGNED NIP BUILDING TO ACCOMMODATE THE DOCUMENT PROCESSING CENTRE (DPC)

BILL No. E-1


DESCRIPTION: ELECTRICAL WORKS

Item Description Unit Qty Rate (USH)


SWITCH GEAR:
To be supplied, transported to site, erected,
connected up complete and commissioned in full
working conditions including all necessary
fixing/mounting accessories. All items shall be as per
general specifications and drawings.

A Metal cased with lockable hinged door,8-Ways TPN Set 1


MCCB-type flush mounted distribution board with
200A TP main integral switch, busbars, neutral and
earth terminal blocks, all as to CRABTREE List No.
1808/21B c/w barrel lock as to CRABTREE list No.
16/L, or equal and approved.

B Metalcased with lockable hinged door, 9-Way SPN Set 1


MCB-type flush mounted consumer unit with 100A
DP main integral swith, busbars, neutral and earth
terminal blocks, with all miniature circuit breakers to
CRABTREE manufacture or equal and approved.

DISTRIBUTION CABLES:

C 600/10000V 95mm sq. 4-Core XLPE-SWA-PVC L/m 30


copper cable, connected from the 200A MCCB of
Sub-main distribution panel board SMDB1, and
terminated on to the in-take terminals of the 200A
TP main in-comer intergral isolator of distribution
board (DB1) (provisional route length)

D 5x16mm sq. Single Core PVC-Insulated copper cables L/m 25


in conduit, connected from 100A TP MCB on DB1
and terminated on to the incommer side of 30kVA
UPS for UPS power supply (Provisional Length).
E 3 x 16mm sq. Single Core PVC-Insulated copper L/m 10
cables in conduit, connected from out put side of
30kVA UPS and terminated on to the incommer of
63A Isolator supplying 9-way Consumer Unit for UPS
power (Provisional Length).

LIGHTING FITTINGS:
A 600mmx600mm 4x18W tubes ceiling No. 93
recessed/SURFACE MOUNTED fluorescent fitting of
slim cross-section with low brightness reflectors,
categorised to CIBSE LG3 Category 3
Mirrorbritelouvre, as to THORN Quattro C-Line
FQCAZ 118 or equal and approved.

B Fresh and contemporary circular luminaire for 9W No. 10


TC-SEL compact fluorescent lamps with die cast
aluminum body, opal difuser in polycarbonate with
eyelid attachments and magnetic gear connected to
Quick fix bracket as THORN LOIRE or approved
equivalent (Type C).

C Wall mounted, enclosed, aluminium-bodied fluorescent


No. 2

D 1200mm 2x35W T5 surface mounted luminaire No. 1


manufactured from rigid rolled steel channel
profile,with high quality,durable post coat powder
paint finish and secure,screw fixed cover plate as to
CROMPTON Crompack range Cat.No. CP235Z or
equal and approved.

Wiring accessories.

E 6A/240V SP 1-Gang 2-Way white moulded plate No. 12


switches c/w flush mounting box, as to CRABTREE
List No. 4170, or approved equivalent.

F 6A/240V SP 2-Gang 2-Way white moulded plate No. 2


switches c/w flush mounting box, as to CRABTREE
List No. 4172, or approved equivalent.
A 6A/240V SP 3-Gang 2-Way white moulded plate No. 1
switches c/w flush mounting box, as to CRABTREE
List No. 4173, or approved equivalent.

B 6A/240V SP 4-Gang 1-Way white moulded plate No. 2


switches c/w flush mounting box, as to CRABTREE
List No. 4173, or approved equivalent.

C 20A DP white moulded plate switch complete with No. 2


trunking mounting box, c/w neon pilot indicator
lamp to CRABTREE List No. 4306/3, or approved
equivalent.

D 240V wall mounted electric hand dryer complete No. 2


with replaceable element as to HEATRAE SADIA
manufacture or approved equivalent.

E 13A SP 2-Gang standard switched socket outlet for No. 37


trunking-mounting c/w 2-gang accessory box, as to
MARSHALL TUFFLEX Ref. Nos. ESS3+ESSB2, or equal
and approved.

F 13A SP 2-Gang non-standard switched socket outlet No. 37


for trunking-mounting c/w 2No. Top plugs and 2-
gang accessory box, as to MARSHALL TUFFLEX Ref.
Nos. ESS20WH+ESSB2WH, or equal and approved.

G LJ Secondary module data/telephone outlets fixed No. 37


on to modular box for flush mounting, as to
MARSHALL TUFFLEX RJ45 modular Cat. No. FD27 + LJ
Master Module Ref. No. FV35+ flush mounting plate
Ref. No. FM16, or equivalent and approved.

H 32A TPN surface mounted metalcladswitchfuse No. 2


complete with 32A HRC fuses, as to MEM List No.
30KXTNC2F + 3x32SB3, or approved equivalent.
A 838mm High Marshall Tufflex Sterling Series 2 No. 12
double sided Power Post c/w 14No. Single gang
accessory boxes, wired 13A single vertical mount
switched socket outlet, vertical dual flush data
module, locking assembly all as MARSHALL TUFFLEX
prod. Code NPPE811142ANWH or approved
equivalent.

B 63A TPN surface mounted metalcladswitchfuse No. 1


complete with 60A HRC fuses, as to MEM List No.
60KXTNC2F + 3x60SB3, or approved equivalent.

C 100A TPN surface mounted metalcladswitchfuse No. 1


complete with 100A HRC fuses, as to MEM List No.
100KXTNC2F + 3x100SB3, or approved equivalent.

D 45A DP cooker control unit with auxilliary socket No. 2


outlet and neon indicators and faceplate marked
"cooker" c/w flush mounting box, as to CRABTREE
List No. 4520/31, or approved equivalent.

WIRING :
Except for items separately specified under
materials, all wiring items must include for all
necessary conduiting/fixing/mounting/mechanical
interlocking accessories/materials.

E Wiring of lighting points in 3x2.5mm sq. SC PVC- No. 106


Insulated copper cables in flush installed uPVC
conduits/PVC Trunking, through wall/grid/time
switches connected from 16A SP MCBs of consumer
unit DB1, as per drawings.

F Wiring of 13A SP standard and non-standard socket No. 74


outlet power points in 3x 2.5mm sq. SC PVC-
Insulated copper cables in ring circuits, drawn in
flush installed PVC conduits, and connected from
32A SP MCBs of Distribution Board DB1 and UPS-
CU1, as per drawing.
A Wiring of power posts in 3x 4mm sq. SC PVC- No. 12
Insulated copper cables in ring circuits, drawn in
flush installed PVC conduits, and connected from
32A SP MCBs of Distribution Board DB1 and UPS-
CU1, as per drawing.

B Wiring Extract fan power points in 3x4mm sq. SC No. 2


PVC-Insulated copper cables, drawn in flush installed
uPVC conduits, and connected from 32A SP MCBs of
distribution board DB1, through 20A DP switches as
per drawing.

C Wiring cooker points in 3x6mm sq. SC PVC-Insulated No. 2


copper cables, drawn in flush installed uPVC
conduits, and connected from 32A SP MCBs of
distribution board DB1 , through 45A DP Cooker
control units, as per drawing.

D Wiring 32A TP fused isolator power point in 5x4mm No. 1


sq. SC PVC-Insulated copper cables, drawn in flush
installed uPVC conduits, and connected from 32A TP
MCBs of distribution board DB1, as per drawing.

E Wiring 63A TP fused isolator power point in 5x6mm No. 1


sq. SC PVC-Insulated copper cables, drawn in flush
installed uPVC conduits, and connected from 32A TP
MCBs of distribution board DB1, as per drawing.

F Wiring 100A TP fused isolator power point in No. 1


5x16mm sq. SC PVC-Insulated copper cables, drawn
in flush installed uPVC conduits, and connected from
32A TP MCBs of distribution board DB1, as per
drawing.

G Allow a provisional sum of Shs.2,000,000 for factory Item 1


inspection and testing by supervising electrical
engineer of all electrical materials for conformity to
approved standards.

PVC-U DADO TRUNKING SYSTEM:


A Profile 201, 220mm x 65mm, 3-Compartment L/m 180
prestige skirting and Dado trunking (for data,
telephone and small power socket outlets),
complete with all necessary accessories such as
couplers, end caps internal and external bends, flat
angles and tees, e.t.c.; all as to MARSHALL-TUFFLEX
manufacture, or equal and approved.

B Allow for testing and commissining of all electrical Item 1


installations including production of installation
certificates to the satisifaction of the supervising
engineer.

FIRE DETECTION SYSTEM.


To be supplied, transported to site, erected,
connected up complete and commissioned in full
working conditions including all necessary
fixing/mounting accessories. All items shall be as per
general specifications and drawings.

A Supply and install 2-Loop Fire alarm Control Panel No 1


c/w 72-hr back-up batterries as ZITON ZP3 EN54-2 +
ZP3 EN54-4 + ZP3 CE or approved equiovalent.

Fire alarm installation

B Supply and install optical smoke detectors No 18

Supply and install optical heat detectors No 1

C Supply and install break glass unit No 4

D Supply and install fire alarm sounders No 4

E Loop wiring complete of fire detection elements in No 27


1.5mm2 heat returdant cables.

F Supply and install fire alarm system cabling No 76


terminations per device.

CCTV SYSTEM.
A Supply and install Dell desktop server, Pentium D No 1
Processor, CD Writter, built in Digital Video Recorder,
512MG Ram, built in multi-channel surveillance
system. DVR Capture card as Avermedia NV6480-
Exp, DVR Card (480/400 fps), Hard drive capacity 1
Terabyte for 65 days recording, with 17'' LCD CCTV
Monitor.

B Supply and install 1/3'' SONY Super HAD CCD No 10


Camera as Surveilux SVV-56CDNRDL210D Hi-Res
(560 TVL) with 3.5-8.0mm Auto-Iris Varifocal lens or
approved equivalent.

C Supply and install 12VDC 16 Output central power No 1


supply.

D Supply and install BNC and SVHS connectors. No 40

E Supply and install coaxial cable RG59 (150m). L/m 450

F Supply, installation and configuration of software Item 1


and interface to Access control and alarm
monitoring including engineering and capture of
database and graphics.

G Allow for testing and commissining of all CCTV to the Item 1


satisifaction of the supervising engineer.

AIRCONDITIONING INSTALLATION
The Contractor is to construct and/or supply, install,
commission to the satisfaction of the Supervising
Consultant the following:

To be supplied and installed c/w all necessary


fixing/clipping/supporting/termination accessories,
as per general specification here-of.

A 3.7kW/240V, 12,600 Btu/h Ceiling mounted cassette No. 8


type air conditioner as DAIKIN model FXCQ32MVE
manufacture or approved equivalent with R410A
refrigerant.
B 7.3kW/240V, 24,900 Btu/h Ceiling mounted cassette No. 2
type air conditioner as DAIKIN model FXCQ63MVE
manufacture or approved equivalent with R410A
refrigerant.

C 11.6W/240V, 39,600 Btu/h Ceiling mounted cassette No. 6


type air conditioner as DAIKIN model FXCQ100MVE
manufacture or approved equivalent with R410A
refrigerant.

D 14.5W/240V, 49,500 Btu/h Ceiling mounted cassette No. 12


type air conditioner as DAIKIN model FXCQ125MVE
manufacture or approved equivalent with R410A
refrigerant.

E REFNET joints No. 8

F 4 branch REFNET header c/w insulation and fixing No. 1


accessories.

G 8 branch REFNET header c/w insulation and fixing No. 3


accessories.

H Air cooled inverter chiller rated at 40.2 No. 1


KW/137,000Btu/h cooling capacity as DAIKIN
RXQ14PY1 or approved equivalent with R-410A
refrigerant complete with circulator pumps, and all
accessories including connection to power supply.

A Air cooled inverter chiller rated at 61.9 KW/211,000 No. 1


Btu/h cooling capacity as DAIKIN RXQ22PY1 or
approved equivalent with R-410A refrigerant
complete with circulator pumps, and all accessories
including connection to power supply.

B Air cooled inverter chiller rated at 144 KW/491,000 No. 1


Btu/h cooling capacity as DAIKIN RXQ52PY1 or
approved equivalent with R-410A refrigerant
complete with circulator pumps, and all accessories
including connection to power supply.
C Copper pipe-work for refrigerant supply and return Item 1
for the whole CBC area including risers complete
with insulation and all accessories.

D Thermostatic controls for ceiling cassettes mounted No. 28


on the wall complete.

E Condensate drainage pipe-work in PVC 32mm L/m 200


complete with all accessories.

G Allow for production of Operation and Maintanance Item 1


Manuals for all equipment supplied.

E-1 Carried to Collection>>>>>>>>>>>>>>>>>>>>>>>>>


ING CENTRE (DPC)

Amount (USH)
0
CONSTRUCTION OF RE-DESIGNED NIP BUILDING TO ACCOMMODATE THE DOCUMENT PROCESSIN

BILLS OF QUANTITIES
GRAND SUMMARY FOR DPC

AMOUNT
BILL NO. DESCRIPTION (Ushs)

GENERAL ITEMS

G-1 General Items 0.00

G-2 Method Related Charges 0.00

DPC SUB - TOTAL "A": (GENERAL ITEMS) >>>>>>>> 0.00


CIVIL, ELECTRICAL AND EXTERNALWORKS

W-1 Civil Works 0.00


E-1 Electrical works 0.00

DPCSUB - TOTAL "B": (CIVIL WORKS AND ELECTRICAL) >>>>> 0.00

CBC TOTAL "C" [A + B] 0.00

ADD 10% CONTIGENCY 0.00

TOTAL "D" [C + CONTIGENCY] 0.00


GRAND TOTAL, VAT EXCLUSIVE
DOCUMENT PROCESSING CENTRE (DPC)