You are on page 1of 1

F

A Plunger 1
B Plunger 2
C Plunger 3
D Suction Piping
E Discharge Piping
F Pump Body (Liquid End) D E
1V DE Vertical 3 2 1
2V NDE Vertical
A
B
C

2V
1V

P-380 A
SUCTION DISCHARGE FLOW FLOWRATE TEMPERATURE (Degree Celcius)
DATE TIME
PRESSURE (Bar) (mmH2O) (m3/hr) A B C D E F 1V 2V
4/1/2018 1300 0.1 975 9 71 73 73 104.2 104.9 101 58 57.6
4/1/2018 1600 0.1 988 9 70 74 72 100.8 101.7 101.3 58 57.2
4/1/2018 1900 0.1 988 9 72 73 73 100.5 102.6 100.7 56 54.3
4/1/2018 2200 0.1 991 9 73 73 74 101.2 101.3 97 55 51.8
5/1/2018 0100 0.1 1000.7 8.9 70 70 72 99.01 103 98.2 56 51.8
5/1/2018 0400 0.1 1000.7 9 70 68.3 73 101.3 101.2 100.1 57 53
5/1/2018 0700 0.1 788 9 69.5 67 70 100.5 99.2 97.3 53 54.3
5/1/2018 1000 0.1 768 8 71 72 71 101.8 102.5 99.5 53 51.9
5/1/2018 1300 0.1 753 7.9 71 71 71.6 102.3 102.7 100.8 56 53.3

4th January 2018 - 5th January 2018


Note:

Dipping occur at 0045. From 1000.7mmH2O to 280mmH2O for 5 min

Dipping occur at 0300 for 5 min

Dipping occur at 0645 for 10 min