XYLUX LR3 High Output Emergency LED Luminaire

XYLUX LR3
High Output Emergency LED Luminaire

Designed for High Lux Level Applications, Typically 10.8 Lux


The LR3 is specially designed for use where a high lux level is required, mainly to comply with the
US one-foot candle levels. The reflector and optic design maximises performance whilst complying
with 10.8 lux requirements.

The lamphead includes a bi-colour LED charge indicator, 500mm wiring loom and recessed
300 Lumens 4 cell NiMH 3 Hours mounting brackets. The XYLUX LR3 continues the XYLUX new generation of LED Emergency
luminaires designed to be effective and unobtrusive. The LED driver and battery pack are located
in an articulated plastic housing, connected via a 500mm wiring loom to the lamp head assembly
SELV 10.8 Lux making on-site installation easy.

The LED lamp head, which contains both the high power white LED and indicator LED, has been

High Output designed to be recessed into a 42-44mm cut out.

Emergency Key features:


LED Luminaire • 2 x 3 Watt high power LED

Suitable for 10.8 • Integral status indicator

Lux Applications • Optical lens and reflector configuration for 10.8 lux applications

• Miniature design blends into the architectural environment

• Various technology options available

• Articulated control gear for easy installation

• SELV compliant

• SmartChargeTM technology

• 3 hours emergency duration

Vigo Place, Aldridge, West Midlands WS9 8UG England


MANUFACTURED IN
+44 (0) 1922 458 255
sales@mackwell.com www.mackwell.com UK
XYLUX LR3 High Output Emergency LED Luminaire
XYLUX LR3
High Output Emergency LED Luminaire

Dimensions

ø5
50m
mm

237mm 237mm

45mm
ø 39mm

41mm
41mm

41mm
241mm

50mm
Central battery version only
ø 41mm
45mm
37mm

MIN. 15mm MIN. 160mm


204mm MAX. 35mm ONCE INSTALLED

18mm

ø 42mm to 44mm

Lamphead Specification Central Battery Specification Features


Luminous flux : 300 lm Supply voltage : 96-230 V AC/DC SmartCharge applies an intermittent charging
Weight of lamphead : 65g Supply frequency : 50/60 Hz duty cycle designed for use with NiMH
Hold-off supply voltage : 230VAC 50/60 Hz batteries. This provides energy efficient
IP rating : IP30 charging maintenance, reduced operating
LED rating : 3W Hold-off changeover
temperatures and optimum service life of
voltage : 138-195V AC NiMH batteries.
Ambient temperature (ta) : 0°C to +40°C
Driver Specification Conductor size : 0.5 - 1.5mm² Technology Options
Supply voltage : 230 V Weight of control gear : 65g Standard 
For applications where self-testing is not
Supply frequency : 50/60 HZ
required or suitable, the non-AutoTest® option
Supply current (max) : 53 mA Relevant Standards
provides the same quality and performance
Power factor : 0.45 EN 60598-2-22 expected of Mackwell products, without the
Total circuit power : 4.0W EN 61347-2-7 AutoTest® feature.
Charge current (nominal) : 200 mA EN 61347-2-13
DALI AutoTest®
Output current (lout) : 500 mA BS 5266-1 Provides benefits by enabling testing and
Output voltage (Vout) (max) : 6V DC EN 62034 monitoring of an emergency lighting system
EN 62386 either on-site or via an internet connection.
Ambient temperature (ta) : 0°C to +35°C
DALI AutoTest® is ideal for monitoring larger
Max case temperature (tc) : +70°C EN 62031
buildings and multiple sites. The product
Conductor size : 0.5 - 1.5mm² EN 62471 defaults to standalone AutoTest when not
connected to a DALI network.
Weight of control gear : 420g
Batteries
Emergency duration : 3 hours Central Battery
The luminaire includes a rechargeable 4.8V Suitable for central battery applications that
Recharge period : 24 hours
4Ah NiMH battery pack for 3 hours operation. use a nominal AC or DC supply of 110V to
240V that includes a hold-off input to inhibit
the LED driver output when a mains supply is
connected.

DS063– Issue 3 - October 2017


XYLUX LR3 High Output Emergency LED Luminaire
XYLUX LR3
High Output Emergency LED Luminaire

105˚ 105˚
Output Current Settings
90˚ 90˚

Spacing information
210
1
Open-Area (based on min. 0.5 lux)
60˚ 60˚
Distance Distance
Mounting Luminaire Luminaire
Height to Luminaire to wall
(m) (m) (m) 420
2
2.0 4.94 2.79 45˚ 45˚
2.5 5.74 3.25
3.0 6.49 3.63
3.5 7.37 3.92
630
3
4.0 8.17 4.22

Escape Route Area (based on min. 1 lux)


0

30˚ 30˚
Distance Distance
15˚ 840 15˚
Mounting Luminaire Luminaire
Height to Luminaire to wall
(m) (m) (m)
2.0 5.43 2.56
2.5 6.71 2.98
3.0 7.73 3.45
3.5 8.65 3.75
4.0 9.48 4.14

Please note:
The spacing tables are provided as a guide
only.
Due to the nature of creating generic lighting
schemes, all schemes should be simulated or
calculated in full, representing as accurately
as possible the final application, and ensuring
compliance with local regulations.

DS063– Issue 3 - October 2017


XYLUX LR3 High Output Emergency LED Luminaire
XYLUX LR3
High Output Emergency LED Luminaire

Order codes
Standard
Order Code Description
9001586 XYLUX LR3 White

DALI
Order Code Description
9001585 XYLUX LR3 White

Central Battery
Order Code Description
9001614 XYLUX LR3 230V White

WARRANTY
XYLUX LR3 are warranted for three years, which covers faulty workmanship and materials. This
“Return to Base“ warranty requires that the product is used within the terms and conditions stated
above, in our literature and on our website. Products returned to us under warranty must be
carriage paid. Mackwell Electronics Ltd. accept no liability for cost incurred.

Mackwell maintains a policy of continuous development and reserves the right to change the details shown on this data sheet
without prior notice.

The contents are intended for guidance only.

Company Reg No: 1414873. VAT Reg No GB330230618


FM12393 EMS516467

Mackwell UK
Vigo Place, Aldridge, West Midlands WS9 8UG. England - Tel. +44 (0) 1922 458 255
Mackwell Hong Kong
Vigo Place, Aldridge, West Midlands WS9 8UG England Unit 1102-1103, 11F, Wing Tuck Commercial Centre,177-183 Wing Lok Street, Sheung Wan, Hong Kong - Tel. +852 9389 4747
+44 (0) 1922 458 255 Mackwell Middle East
sales@mackwell.com www.mackwell.com PO Box : 513863 SAIF Zone, UAE - Tel. +971 6 552 8328

DS063– Issue 3 - October 2017

You might also like