You are on page 1of 1

1.50 0.80 0.

65
0.25 1.00 0.25 0.80

2.10

2.10

2.10

2.10
F. F. L.
D D D D
1 2 3 4
DESCRIPTION : WOODEN SOLID DOOR W/ FIXED GLASS WOODEN SOLID DOOR PVC DOOR FIXED GLASS DOOR
TYPE ON 2"x5" DOOR JAMB TYPE ON 2"x5" DOOR JAMB ON 2"x5" DOOR JAMB TYPE IN ANALOK FRAME
LOCATION : MAIN ENTRANCE SEE FLOOR PLAN ALL T&B LIBRARY
NO. OF SETS : 1 4 5 1

B
C. HT.: = +2.66 MTS
3.00
A
0.75 0.75 0.75 0.75 0.80 0.90
C. HT.: = +2.60 MTS

B
C. HT.: = +2.66 MTS

2.10

2.10

2.10
A
C. HT.: = +2.60 MTS
1.50
0.75 0.75
A A A
C. HT.: = +2.60 MTS
C. HT.: = +2.60 MTS C. HT.: = +2.60 MTS B
C. HT.: = +2.66 MTS F. F. L.
D D D
A
B
C. HT.: = +2.66 MTS
5 6 7
C. HT.: = +2.60 MTS
DESCRIPTION : SLIDING SMOKED GLASS DOOR SCREEN DOOR WOODEN SOLID DOOR
B
C. HT.: = +2.66 MTS
TYPE IN ANALOK FRAME TYPE IN ANALOK FRAME TYPE ON 2"x5" DOOR JAMB
LOCATION : LIBRARY WASHING AREA KITCHEN
NO. OF SETS : 1 1 1

3.90
2.53
A 2.50 0.63 0.63 0.63 0.63 2.50
C. HT.: = +5.60 MTS
A
C. HT.: = +2.60 MTS A
C. HT.: = +2.60 MTS
0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63

1.00
1.20

1.58
2.10

2.10

2.10

1.40
1.10
0.90

0.52
F. F. L.
W W W W
1 2 3 4
DESCRIPTION : SLIDING WINDOW WITH FIXED GLASS SLIDING WINDOW WITH FIXED GLASS SLIDING WINDOW WITH FIXED GLASS FIXED GLASS WINDOW
IN ANALOK FRAME IN ANALOK FRAME IN ANALOK FRAME IN ANALOK FRAME
LOCATION : SEE FLOOR PLAN SEE FLOOR PLAN SEE FLOOR PLAN OPEN BELOW
NO. OF SETS : 6 3 2 1

1.27 1.93
0.64 0.64 1.27 0.48 0.48 0.48 0.48
REFLECTED CEILING PLAN REFLECTED CEILING PLAN 0.64 0.64
1 GROUND FLOOR PLAN
SCALE
2 SECOND FLOOR PLAN
SCALE
A 4 1:100MTS
A 4 1:100MTS

0.60

1.58
2.00
GENERAL NOTES AND SPECIFICATIONS :

2.10

2.10
LEGEND:

1.50

0.52
A CENTER LIGHT F. F. L.
W W W SCHEDULE OF
LIGHTING FIXTURE 5 6 7 3 DOORS & WINDOWS
FIXED GLASS WINDOW SLIDING WINDOW SLIDING WINDOW WITH FIXED GLASS SCALE
DESCRIPTION : A 4 1:50MTS

PIN LIGHT IN ANALOK FRAME IN ANALOK FRAME IN ANALOK FRAME

B WALL LAMP
LOCATION :
NO. OF SETS :
OPEN BELOW
1
ALL T&B
4
SEE FLOOR PLAN
1

REPUBLIC ACT 9266


ARCHITECTURE ACT OF 2004 ARTCLE IV SECTION 33
DRAWING AND SPECIFICATIONS DULY SIGNED, STAMPED OR SEALEDAS
PROJECT TITLE / LOCATION : SHEET CONTENTS : DATE :
OWNER : SHEET NO. :
INSTRUMENTS OF SERVICE ARE THE INTELLECTUAL PROPERTIES & DOCUMENTS OF
THE ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED
DRAWN BY:
OR NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT THE CONSENT OF THE
REFLECTED CEILING PLAN
A-4
ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO MAKE COPIES
OF SAID DOCUMENTS FOR USE IN THE REPETITION OF AND FOR OTHER PROJECTS
CHECKED BY :
OR BUILDINGS, WHETHER EXECUTED PARTLY OR INWHOLE.
PRESIDENTIAL DECREE NO. 49 " PROTECTION OF INTELLECTUAL PROPERTY " NOV. 14 1974
CEILING NOTES
WORKS OF ARTS, ARCHITECTURE, MODELS AND DESIGNARE CREATIVE WORK AND REVIEWED BY :
CONSIDERED AS PART OF THE INTELLECTUAL PROPERTY OF THE AUTHOR DULY
PROTECTED UNDER PD 49
LEGENDS
DATE :

4
APRIL 2017
REPUBLIC ACT 8293 INTELLECTUAL PROPERTY LAW SECTION 186 SCHEDULE OF DOORS & WINDOWS
WORK OF ARCHITECTURE - COPYRIGHT IN A WORK OF ARCHITECTURE SHALL
INCLUDE THE RIGHT TO CONTROL THE ERECTION OF ANY BUILDING WHICH
PLOTTING DATE :
REPRODUCES THE WHOLE OR A SUBTANTIAL PART OF THE WORK EITHER IN ITS
ORIGINAL FORM OR IN ANY FORM RECOGNIZABLY DERIVED FROM THE ORIGINAL.