You are on page 1of 3

CONVEX ROUTING

40.00

35.00

30.00

25.00
QI and QO (m^3/s)

20.00

15.00

10.00

5.00

0.00
0.0 1.0 2.0 3.0 4.0 5.0 6.0

Time, t (hr)
CONVEX ROUTING GoConvex.xls
See Box 9-6. S.L. Dingman
Input Data Computed Values Physical Hydrology, 2nd Ed.

Reach Characteristics:
Length, X = 1000 m
Width, B = 30.0 m
Slope, S = 0.0005
Manning's n = 0.05
Inflow-Hydrograph Characteristics:
Inflow hydrograph peak, QIpk = 35.00 m^3/s
Duration of inflow-hydrograph rise, Tr = 1.00 hr
Flow Characteristics:
Flow Depth, Y-3/4 = 1.50 m
Flow Velocity, U-3/4 = 0.58 m/s
Flood-Wave Velocity, U-F = 0.97 m/s
Reach Travel Time, T* = 1026 s = 0.285 hr
Select Routing Time Step:
Dt must be < T* and < Tr/5
Dt = 0.1 hr
value OK

Routing coefficient CX = 0.35

Enter inflow hydrograph QI values at successive time steps:

Time QI QO
Step (hr) (m^3/s) (m^3/s)
0 0.0 0.00 0.00
1 0.1 3.50 0.00
2 0.2 7.00 1.23
3 0.3 10.50 3.25
4 0.4 14.00 5.80
5 0.5 17.50 8.68
6 0.6 21.00 11.77
7 0.7 24.50 15.01
8 0.8 28.00 18.34
9 0.9 31.50 21.73
10 1.0 35.00 25.16
11 1.1 33.06 28.61
12 1.2 31.11 30.17
13 1.3 29.17 30.50
14 1.4 27.22 30.03
15 1.5 25.28 29.05
16 1.6 23.33 27.72
17 1.7 21.39 26.18
18 1.8 19.44 24.50
19 1.9 17.50 22.73
20 2.0 15.56 20.89
21 2.1 13.61 19.02
22 2.2 11.67 17.12
23 2.3 9.72 15.21
24 2.4 7.78 13.28
25 2.5 5.83 11.35
26 2.6 3.89 9.41
27 2.7 1.94 7.47
28 2.8 0.00 5.53
29 2.9 3.59
30 3.0 2.33
31 3.1 1.51
32 3.2 0.98
33 3.3 0.64
34 3.4 0.41
35 3.5 0.27
36 3.6 0.17
37 3.7 0.11
38 3.8 0.07
39 3.9 0.05
40 4.0 0.03
41 4.1 0.02
42 4.2 0.01
43 4.3 0.01
44 4.4 0.01
45 4.5 0.00
46 4.6 0.00
47 4.7 0.00
48 4.8 0.00
49 4.9 0.00
50 5.0 0.00