Professional Documents
Culture Documents
ULLC100
Conform to the UL 1598 and CSA C22.2 No. 250.0-08 standards
Mounting details
Comes with 4 steel anchor bolts,
3/4" x 20" (19 ø mm X 508 mm),
4 nuts and 4 washers.
Bolt circle : 10 1/2"
13 1/8" (333mm)
Important: Do not obstruct space
between anchor plate and concrete base B.C. allowed : 9 1/2
Anchor Plate
Mounting details
Comes with 4 steel anchor bolts, Semelle d’ancrage
3/4" x 20" (19 ø mm X 508 mm),
4 nuts and 4 washers.
Important: Do not obstruct space Bolt circle : 10 1/2" ø (267 mm)
between anchor plate and concrete base B.C. allowed : 9 1/2" to 11 1/2" (267 mm to 292 mm)
17 1/8" (435mm) 13 1/8" (333mm)
Détails d’ancrage
Livré avec 4 boulons d’ancrage en acier,
3/4" x 20" (19 mm ø X 508 mm),
4 écrous et 4 rondelles.
Light Column Height (FT.) Important : Ne pas obstruer l’espace entre Cercle de boulonna
la semelle et la base de béton. C.B. possible : 9 1/2
From 10 feets to 20 with 1 foot incrementation Semelle d’ancrage
10 1/4 po (260 mm)
1 L70 = 100,000 hrs (at ambient temperature = 25°C and forward current = 700 mA). 4 Compared to an average light column (equivalence should always be confirmed by a photometric layout).
2 May vary depending on the optical distribution used. 5 Not available with 347 and 480 volts.
3 System wattage includes the lamp and the LED driver.
Luminaire Options
To customize the Vertical Projection LED Light PH7
Post you can choose amongst a variety of Photoelectric cell
PH8
Real Wood Panel Ipe Type Photoelectric cell
CDMGP Dynadimmer custom dimming scenario allowing the user to program up to 5 time periods
and multiple dimming levels from 100% to 10% of total wattage.
OVR Dynadimmer override function offering the possibility to go back to full power at any time via
an electrical signal of 120VAC to 277VAC from a motion sensor, a switch, a relay or else.
CLO Pre-set driver to manage the lumen depreciation by adjusting the power given to the LEDs
offering the same lighting intensity during the entire lifespan of the lamp.
AST Pre-set driver for progressive start-up of the lamp to optimize energy management and
enhance user visual comfort at start-up.
OTL Pre-set driver to signal end of life of the lamp for better fixture management.
Other options are also available according to your needs. Please contact us for more information.
Ordering Example
Light
Optical Driver Column Luminaire
Luminaire Lamp Voltage Finish
System Options Height Options
(FT.)
ULLC100 35W32LED4K-R LEV3 120 DMG 16 - GR
Assembly Example
20’
18’
16’
14’
12’
20'-0" (6096mm)
10’
18'-0" (5486mm)
16'-0" (4877mm)
8’
12'-0" (3658mm)
10'-0" (3048mm)
6’
4’
2’
0’