You are on page 1of 5

Important : Note :

These drawings as instruments of service, Written dimensions on these drawings


are property and documents of Architect. shall have precedence over scaled
It shall be unlawfull for any person dimensions. Contractors shall verify and
without be responsible for all dimensions and
the written consent of the Architect or conditions on the job. The designer must
authors of said documents, to duplicate be notified immediately of any variations
or copy said documents. [ R.A. 545, Sec. from the dimensions and conditions shown
25(4) ] by these drawings.
24.20

6.04 5.00 4.57 5.01 3.04

1.75

2.30
4.20 2.96 5.46
24.80

SCALE 1:150MTS

Important : Note :
These drawings as instruments of service, Written dimensions on these drawings
are property and documents of Architect. shall have precedence over scaled
It shall be unlawfull for any person dimensions. Contractors shall verify and
without be responsible for all dimensions and
the written consent of the Architect or conditions on the job. The designer must
authors of said documents, to duplicate be notified immediately of any variations
or copy said documents. [ R.A. 545, Sec. from the dimensions and conditions shown
25(4) ] by these drawings.
23.40
3.75 3.75 3.75 3.75 4.80 3.60

2.55
TWIN RM TWIN RM TWIN RM TWIN RM TWIN RM

6.45

3.50
14.18
14.70

2.40
1.80

HALLWAY ELEV
2.58

5.73
3.88

TWIN RM TWIN RM TWIN RM TWIN RM TWIN RM

3.74 3.75 3.75 3.75 5.70 2.71


23.40

SCALE 1:100MTS

Important : Note :
These drawings as instruments of service, Written dimensions on these drawings
are property and documents of Architect. shall have precedence over scaled
It shall be unlawfull for any person dimensions. Contractors shall verify and
without be responsible for all dimensions and
the written consent of the Architect or conditions on the job. The designer must
authors of said documents, to duplicate be notified immediately of any variations
or copy said documents. [ R.A. 545, Sec. from the dimensions and conditions shown
25(4) ] by these drawings.
3.75 3.75 3.75 3.75 8.40

3.60

TWIN RM-6 TWIN RM-6

6.05
TWIN RM-8 TWIN RM-8 SUITE RM-10
6.45

14.18
14.70

2.40
1.80

HALLWAY ELEV

5.73
6.45

SUITE-RM. SUITE-RM. SUITE-RM.

SUIT RM-3
53.3M2/16.1PY

7.50 7.50 5.70 2.70


23.40

SCALE 1:100MTS

Important : Note :
These drawings as instruments of service, Written dimensions on these drawings
are property and documents of Architect. shall have precedence over scaled
It shall be unlawfull for any person dimensions. Contractors shall verify and
without be responsible for all dimensions and
the written consent of the Architect or conditions on the job. The designer must
authors of said documents, to duplicate be notified immediately of any variations
or copy said documents. [ R.A. 545, Sec. from the dimensions and conditions shown
25(4) ] by these drawings.
23.40
19.80 3.60

WATER TANK ROOM

3.05
MACHINERY ROOM

2.10
ELEV. MACHINE
ROOM

0.90
PIPE. SPACE

ROOF DECK
14.70

2.40
ELEV. MACHINE
ROOM

5.74
0.52
20.70 2.70
23.40

SCALE 1:100MTS

Important : Note :
These drawings as instruments of service, Written dimensions on these drawings
are property and documents of Architect. shall have precedence over scaled
It shall be unlawfull for any person dimensions. Contractors shall verify and
without be responsible for all dimensions and
the written consent of the Architect or conditions on the job. The designer must
authors of said documents, to duplicate be notified immediately of any variations
or copy said documents. [ R.A. 545, Sec. from the dimensions and conditions shown
25(4) ] by these drawings.

You might also like