You are on page 1of 6

1 TYPICAL DETAIL AT EXISTING LINTEL REPLACEMENT

S000 SCALE: 3/4"=1'-0

2 ALTERNATE DETAIL AT EXISTING LINTEL REPLACEMENT


S000 SCALE: 3/4"=1'-0

LINTEL SCHEDULE
3 TYPICAL DETAIL AT EXISTING LINTEL REPLACEMENT
S000 SCALE: 3/4"=1'-0

S000
X1 2 X3

X1 2 X3

XA XA

B B

1 PARTIAL FOUNDATION PLAN 2 PARTIAL FOUNDATION / MEZZANINE FRAMING PLAN


N N
S100 SCALE: 1/4"=1'-0 S100 SCALE: 1/4"=1'-0

S100
4

1 PARTIAL SECOND FLOOR FRAMING PLAN - CORRIDOR C-2


N
S101 SCALE: 1/4"=1'-0
4 TYPICAL RAMP SLAB DETAIL 5 TYPICAL SECTION AT CONCRETE RAMP BASE
S101 SCALE: 3/4"=1'-0" RE: 1/S101, 2/S101 S101 SCALE: 3/4"=1'-0

6 SECTION AT RAMP EDGE 7 TYPICAL FRAMING AT ROOF OPENING


S101 SCALE: 3/4"=1'-0 S101 SCALE: N.T.S. RE: 2/S100

2 PARTIAL SECOND FLOOR FRAMING PLAN - CORRIDOR E-2


N
S101 SCALE: 1/4"=1'-0

8 TYPICAL SECTION AT ROOF OPENING 9 WF STEEL LINTEL AT EXISTING MASONRY WALL 10 WF STEEL LINTEL BEARING AT EXISTING MASONRY WALL
S101 SCALE: 3/4"=1'-0 RE: 7/S101 S101 SCALE: 3/4"=1'-0" RE: 2/S000 S101 SCALE: 3/4"=1'-0" RE: 2/S000

3 PARTIAL FOURTH FLOOR FRAMING PLAN - FRESH AIR INTAKE


N
S101 SCALE: 1/4"=1'-0

S101
1 PARTIAL ROOF FRAMING PLAN
N
S102 SCALE: 1/4"=1'-0

2
S102
WF STEEL BEAM BEARING AT EXISTING MASONRY WALL
SCALE: 3/4"=1'-0" RE: 1/S102
3
S102
BOND BEAM LINTEL AT CMU WALL
SCALE: 3/4"=1'-0" RE: 2/S100 S102
1 SECTION AT EXISTING FOUNDATION WALL 2 SECTION AT CONCRETE ENCASEMENT 3 INTERIOR CMU WALL BEARING AT FOOTING 4 COLUMN BEARING AT FOOTING
S200 SCALE: 1/2"=1'-0 RE: 1/S100 S200 SCALE: 1/2"=1'-0 RE: 1/S100 S200 SCALE: 1/2"=1'-0" RE: 1/S100 S200 SCALE: 1/2"=1'-0 RE: 1/S100

TYPICAL VERTICAL
5 TYPICAL STEEL COLUMN BASE DETAIL 6 SECTION AT CONCRETE INFILL WALL 7 TYPICAL SLAB-ON-GRADE DETAIL 8 CONSTRUCTION JOINT DETAIL AT CONCRETE WALL
S200 SCALE: 1"=1'-0" RE: 4/S200 S200 SCALE: 1/2"=1'-0" RE: 1/S100 S200 SCALE: 3/4"=1'-0" RE: 2/S100 S200 SCALE: 1/2"=1'-0 RE: 2/S100

CMU WALL
9 NEW CONCRETE WALL AT EXISTING CONCRETE WALL 10 CMU WALL BEARING AT CONCRETE FOUNDATION WALL 11 BEARING AT EXISTING CONCRETE FOUNDATION WALL 12 SECTION AT THRESHOLD
S200 SCALE: 1/2"=1'-0 RE: 2/S100 S200 SCALE: 1/2"=1'-0 RE: 2/S100 S200 SCALE: 1/2"=1'-0 RE: 2/S100 S200 SCALE: 1/2"=1'-0 RE: 2/S100

S200
B

CONCRETE SLAB / METAL DECK CONCRETE SLAB / METAL DECK WF STEEL BEAM CONCRETE SLAB / METAL DECK
1 BEARING AT EXISTING CONCRETE FOUNDATION WALL 2 PARALLEL TO EXISTING CONCRETE FOUNDATION WALL 3 BEARING AT EXISTING CONCRETE FOUNDATION WALL 4 PARALLEL TO WF STEEL BEAM
S201 SCALE: 3/4"=1'-0 RE: 2/S100 S201 SCALE: 3/4"=1'-0 RE: 2/S100 S201 SCALE: 3/4"=1'-0 RE: 2/S100 S201 SCALE: 3/4"=1'-0 RE: 2/S100

PLAN DETAIL AT
5 CONCRETE SLAB / METAL DECK BEARING AT WF STEEL BEAM 6 CONCRETE SLAB / METAL DECK BEARING AT WF STEEL BEAM 7 CONCRETE SLAB BEARING AT CONCRETE MASONRY WALL 8 INTERSECTION OF CMU WALL AND EXISTING MASONRY WALL
S201 3/4"=1'-0" RE: 2/S100 S201 3/4"=1'-0" RE: 2/S100 S201 3/4"=1'-0" RE: 2/S100 S201 SCALE: 3/4"=1'-0 RE: 2/S100

9 TYPICAL SECTION AT EXISTING SLAB INFILL 10 STEEL BAR GRATING BEARING AT EXISTING MASONRY WALL 11 TYPICAL WF STEEL BEAM TO WF STEEL BEAM CONNECTION 12 TYPICAL WF STEEL BEAM TO COLUMN CONNECTION
S201 SCALE: 3/4"=1'-0 S201 SCALE: 3/4"=1'-0" RE: 3/S101 S201 SCALE: 3/4"=1'-0" S201 SCALE: 3/4"=1'-0"

S201

You might also like