Professional Documents
Culture Documents
Tobias Otto, Dr Med Dent* During past years, the vision of pro-
ducing all-ceramic crowns chairside
has turned into a real option to be
The objective of this study was to investigate the clinical performance of: (1) adhe- considered for private practice. A
sively placed Cerec crowns with reduced stump preparations, and (2) Cerec endo choice of computer-aided design/
crowns. The crowns were examined at baseline using modified USPHS criteria in 20 manufacturing (CAD/CAM) systems
patients with 10 Cerec crowns with reduced stump preparations and 10 Cerec endo is available on the dental market
crowns. All crowns had been produced chairside with the Cerec 3 CAD/CAM (Celay, Mikrona; Cerec, Sirona;
method using the function mode. The crowns were machined from Vita Mk II felds- Procera, Nobel Biocare), allowing
pathic ceramic blocks, polished manually, and placed with dual-curing composite the machining of crowns and crown
luting agent using a functional adhesive. After 1 year, a follow-up examination of copings based on digitally recorded
the crowns was conducted; all 20 Cerec crowns were rated with a clinically accept-
preparation data.
able A or B rating. Fractures or loss of retention were not observed. The method of
The aim of producing and plac-
producing and placing all-ceramic crowns with reduced stump preparations and
ing a ceramic restoration chairside in
endo crowns chairside in one appointment can be implemented successfully in pri-
vate practice. (Int J Periodontics Restorative Dent 2004;24:446–455.)
one appointment is best met by the
Cerec method.1 The positive long-
term results with Cerec inlays and
onlays2,3 of feldspathic ceramic using
the Cerec 1 method have led to an
expansion of the treatment options
to include crowns. The Cerec 2
method is the first to allow for the
production and placement of
crowns4; in most cases, a reference
impression or waxup is used to aid
the design (correlation mode). With
Cerec 3,5 it became possible to pro-
duce crowns in the clinical routine of
*Private Practice, Aarau, Switzerland.
a private practice, directly at chair-
Correspondence to: Dr Tobias Otto, Bahnhofstrasse 10, CH-5000 Aarau, side, and to place them within an
Switzerland. Fax: + 41 62 824 67 26. e-mail: toebu@bluewin.ch acceptable period, without the need
COPYRIGHT © 2004 BY QUINTESSENCE PUBLISHING CO, INC. Volume 24, Number 5, 2004
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
448
COPYRIGHT
The International Journal of Periodontics © 2004
& Restorative BY QUINTESSENCE PUBLISHING CO, INC.
Dentistry
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
449
Fig 1a Vital premolar with buccal cusp Fig 1c After removing the old amalgam
fracture: indication for reduced stump restoration, no buildup is made and the
preparation. tooth is prepared in a reduced form, ready
for the second optical impression.
Fig 1b (right) Occlusion is saved in the
computer. The missing cusp is replicated
closely enough to represent the occlusal sit-
uation for the optical impression (Fermit N,
Ivoclar Vivadent).
COPYRIGHT © 2004 BY QUINTESSENCE PUBLISHING CO, INC. Volume 24, Number 5, 2004
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
450
Fig 2a Status after root canal treatment Fig 2b Endo crown preparation before
in molar with failing provisional restoration. taking optical impression.
clinical crown was completely The crowns were reconstructed Checker, GC). The interproximal con-
replaced by the ceramic, and an on the screen based on the optical tacts, which can be digitally adusted
inlay-shaped post was prepared impression of the preparation and in all three dimensions, were
in the cavity of the tooth (Fig 2). the initial situation and subsequently checked carefully with waxed dental
With an epigingival or slightly sub- machined from a feldspathic ceramic floss (ACT, Johnson & Johnson).
gingival (0.5 mm) location of the block (Vita Cerec Mk II, Vita) in the Usually, the contact points were con-
preparation margin, retraction Cerec grinding unit. The crown structed slightly too strong and
cord (Ultrapak, Ultradent) was machined in this fashion was tried in adapted clinically with a diamond
placed. and tested for accuracy of fit (Fit bur. In case of a weak interproximal
COPYRIGHT
The International Journal of Periodontics © 2004
& Restorative BY QUINTESSENCE PUBLISHING CO, INC.
Dentistry
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
451
COPYRIGHT © 2004 BY QUINTESSENCE PUBLISHING CO, INC. Volume 24, Number 5, 2004
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
452
floss (ACT). The results were again rated A. Crowns presenting minor
rated based on the modified defects (eg, moderate overhangs
USPHS criteria (Table 3). In addi- or undercuts, or slight changes in
tion, questionnaires were used to texture and color) that did not have
obtain infor mation about the any influence on the clinical result
patients’ subjective satisfaction were allocated the rating B. C and
and potential postoperative dis- D ratings were given to crowns that
comfort. Sensitivity was assessed required repairs or even replace-
using a CO2 test, and radiographs ment restorations because of frac-
were taken. The crowns were also tures, major defects, or retention
documented photographically. loss. Furthermore, crowns pre-
Crowns that did not show any clin- senting sensitivity problems, per-
ical alteration and did not require sisting pain, or secondary caries
any follow-up treatment were were rated clinically unacceptable.
COPYRIGHT
The International Journal of Periodontics © 2004
& Restorative BY QUINTESSENCE PUBLISHING CO, INC.
Dentistry
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
453
Results crowns that received a B rating for crowns, and no food impaction was
marginal adaptation increased after reported. There were no complaints
Ten patients with one crown with 1 year from 30% to 55%. For the cri- about persisting discomfort of any
reduced stump preparation each terion surface quality, B ratings kind after placement of the recon-
and 10 patients with one endo increased from 45% to 75%. In terms structions.
crown each were included in the fol- of anatomic shape and color, the
low-up examination. Mean func- number of A ratings (60% and 30%,
tional time was 15 months (12 to 16 respectively) and B ratings (40% and Discussion
months). None of the crowns were 70%, respectively) did not change
allocated a C or D rating after 1 year (Table 3). Caries and endodontic Since the Cerec 3 method was intro-
of service. In particular, fractures or problems were not observed at the duced only in 2000, long-term stud-
loss of retention were not seen. Of follow-up examination. All patients ies on the clinical performance of
the reconstructions that received a were satisfied with the appearance these reconstructions are still lack-
good clinical rating, the number of and chewing comfort of their Cerec ing. The short time span since the
COPYRIGHT © 2004 BY QUINTESSENCE PUBLISHING CO, INC. Volume 24, Number 5, 2004
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
454
introduction of this technology for force transmission between the rigid Conclusions
practice also limited the number of ceramic of endo crowns and the
cases available for evaluation. The remaining hard tissue are unclear; 1. Cerec crowns with reduced
aim of presenting early results was long-term experience will have to stump preparations and Cerec
to communicate whether the Cerec show whether this type of construc- endo crowns can be easily de-
3 method for production and place- tion holds true over time. However, signed and custom machined
ment of all-ceramic crowns—chair- the building up of crown stumps chairside with anatomically cor-
side, in one appointment, and with- using root posts has been critically rect proportions, ready to be
out any physical impression—can reviewed repeatedly.19–21 adhesively placed during a single
be successfully implemented in pri- Keeping this in mind, the com- appointment.
vate practice. puter-generated endo crown seems 2. Crowns with reduced stump
Earlier experience with crowns to offer a valid alternative for the preparations and endo crowns
produced using Cerec 2 well docu- reconstruction of nonvital teeth.22 machined from Vita Mk II felds-
mented the technical prerequisites The preliminary results of the present pathic ceramic blocks did not
for achieving good results with study after 1 year show good clinical show any fractures after 1 year.
regard to accuracy of fit,12 fracture performance of Cerec 3 crowns with 3. Adhesive bonding of all-ceramic
resistance,13 and adhesive bond- reduced stump preparations and Cerec crowns with reduced
ing.14 In particular, with reduced endo crowns. The chairside concept preparations as well as endo
stump preparations or endo crowns, to produce and place all-ceramic crowns using a functional dentin-
fracture resistance significantly crowns with reduced stump prepa- enamel adhesive and a dual-cur-
increases with greater ceramic thick- rations and endo crowns in one ing resin-based composite lut-
ness.8 This may contribute to mini- appointment can be successfully ing agent did not show any loss
mizing the fracture risk of all-ceramic implemented in private practice and of retention or root fractures after
Cerec 3 crowns with reduced stump shows high clinician and patient ben- 1 year.
preparations and endo crowns. In efits.
comparable all-ceramic crowns, frac-
tures are the most frequent reason
for failure. IPS Empress complete
crowns (Ivoclar Vivadent) show a
fracture rate of 5% after 2 years,15
and one private practice demon-
strated a fracture rate of 6% up to 4
years.16 Dicor crowns (Dentsply)
have a considerably higher fracture
rate of 14%17 and 16%.18
The reduced stump preparation
exhibits less preparation surface than
the classic conical crown stump.
Thus, macromechanical retention is
reduced or nonexistent. The ques-
tion is whether sufficient microre-
tention can be provided by the
adhesive bond of the crown. In the
case of endo crowns, the effects of
COPYRIGHT
The International Journal of Periodontics © 2004
& Restorative BY QUINTESSENCE PUBLISHING CO, INC.
Dentistry
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.
455
COPYRIGHT © 2004 BY QUINTESSENCE PUBLISHING CO, INC. Volume 24, Number 5, 2004
PRINTING OF THIS DOCUMENT IS RESTRICTED TO PERSONAL USE ONLY.
NO PART OF THIS ARTICLE MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
WITHOUT WRITTEN PERMISSION FROM THE PUBLISHER.