Client: XXXX Report No: IES-XXX-UTM-08

Address: XXXXXX Date of Inspection: 30-12-2017


Project: XXXXXX Surface Condition: Clean
Equipment No: NDT System, Modsonic Location: Engine Room (Port Side & Starboard Side
Class Min Gauged Diminution
Tank/Space Structure Element/ Draw Ref. Orig. Thk Thk
Tank/Space Port Side St Side Port Side St Side
Reverse Side Element frame No.
mm mm mm mm mm % mm %
N/A Engine Room N/A N/A 12.00 9.00 11.20 10.20 0.80 6.67 1.80 15.00
N/A Engine Room N/A N/A 12.00 9.00 11.40 10.00 0.60 5.00 2.00 16.67
N/A Engine Room N/A N/A 12.00 9.00 11.60 11.30 0.40 3.33 0.70 5.83
1
N/A Engine Room N/A N/A 12.00 9.00 11.80 11.40 0.20 1.67 0.60 5.00
N/A Engine Room N/A N/A 12.00 9.00 11.40 11.00 0.60 5.00 1.00 8.33
N/A Engine Room N/A N/A 12.00 9.00 11.60 11.40 0.40 3.33 0.60 5.00
N/A Engine Room N/A N/A 12.00 9.00 10.70 10.50 1.30 10.8 1.50 12.50
N/A Engine Room N/A N/A 12.00 9.00 11.80 11.30 0.20 1.67 0.70 5.833
N/A Engine Room N/A N/A 12.00 9.00 11.40 10.30 0.60 5.00 1.70 14.17
2
N/A Engine Room N/A N/A 12.00 9.00 11.20 10.20 0.80 6.67 1.80 15.00
N/A Engine Room N/A N/A 12.00 9.00 11.40 10.30 0.60 5.00 1.70 14.17
N/A Engine Room N/A N/A 12.00 9.00 11.70 10.40 0.30 2.50 1.60 13.33
& Starboard Side
Renewed