4 Voltage and Functional Tests/Drift 01.

93
4.2.2 EPROM CHECK

4.2.2 EPROM CHECK


A cross-check sum test of the system program memory (EPROM) is performed whenever the
control is switched on (prior to the POWER ON routines). In the cyclic mode, a parity check is
performed.
If a difference is found between the set sum and the actual sum, the control displays the text
”CHECKSUM ERROR SYSTEM MODULE” on the screen. If a difference is found in the
cyclic mode, the text ”TIME OUT IF PARITY”is displayed together with the contents of the
CPU register.
If the system module is not inserted, the following message appears on the screen:

WRONG EPROM SYSTEM MODULE

The system identifier can be read out in overall reset mode (overall reset display)
Meaning:
3GE 570.822.9602.30
Release 0

Software version 3

02 Language: 00 English/German
02 French/German
03 Italian/German
04 Spanish/German
05 Dutch/German
06 Russian/German
07 Swedish/German
08 Finnish/German
10 Polish/German
11 Hungarian/German
12 Czech/German
13 Turkish/German
20 French/English
21 Italian/English
22 Spanish/English

96 Type of control: 96 T Version


97 M Version

805 ..... System 810 GA1 and not configurable


818 ..... System 810 GA1 and configurable (option N30)
821 ..... System 810 GA2
822 ..... System 810 GA3/820 GA3
570 ..... SINUMERIK

4–2 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DL02