You are on page 1of 5

2014 PIVOT ARCHITECTURE

STANDARD MECHANICAL ABBREVIATIONS FIRE PROTECTION SYMBOLS GENERAL NOTE


AF AIRFOIL IE INVERT ELEVATION FP FIRE PROTECTION
AFF ABOVE FINISHED FLOOR IN INCH(ES) THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY
SPR FIRE SPRINKLER APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.
AHP APPARATUS HOUSING PLENUM INSUL INSULATION
ALT ALTERNATIVE ISOL ISOLAT(OR)(ION) DP DRY PIPE SPRINKLER
AL ALUMINUM KW KILOWATT PA PRE-ACTION SYSTEM
APD AIR PRESSURE DROP KWH KILOWATT HOUR WSP WET STANDPIPE MISC. VALVES & COCKS
C

APPROX APPROXIMATELY L LENGTH DSP DRY STANDPIPE


ARCH ARCHITECT(URAL) LAT LEAVING AIR TEMP SHUT-OFF VALVE (SEE SPECS FOR TYPE REQUIRED)
AUTO AUTOMATIC LB POUND FDC FIRE DEPARTMENT CONNECTION GLOBE VALVE
BDD BACKDRAFT DAMPER LDB LEAVING DRY BULB S
SHUT-OFF VALVE W/ TAMPER SWITCH
BI BACKWARD INCLINED LF LINEAR FEET SRC STANDPIPE ROOF CONNECTION TRIPLE DUTY VALVE
D PROFESS
TERE
BLDG BUILDING LFT LEAVING FLUID TEMPERATURE
BSMT BASEMENT LVG LEAVING CHECK VALVE G I NEE

REGIS

IONA
SO STANDPIPE OUTLET N
BTU BRITISH THERMAL UNIT

R
LWB LEAVING WET BULB 2-WAY CONTROL VALVE 18329PE

L
BTUH BRITISH THERMAL UNITS PER HOUR LWT LEAVING WATER TEMPERATURE UPRIGHT SPRINKLER HEAD
3-WAY CONTROL VALVE
CFH CUBIC FEET PER HOUR MAX MAXIMUM PENDANT SPRINKLER HEAD OREGON

NIC

r.
BALANCING VALVE ar

M
CFM CUBIC FEET PER MINUTE

J
MBH THOUSAND BTU PER HOUR SIDEWALL SPRINKLER HEAD ch
1 9 19
9

S,
FC

H
CFS CUBIC FEET PER SECOND MECH MECHANICAL LA IN

O
F FLOW CONTROL VALVE S P. C O L L
CLG CEILING OR COOLING MFR MANUFACTURER FLOW SWITCH S
CONC CONCRETE MIN MINIMUM S SOLENOID VALVE EXPIRES 12-31-15
SUPERVISED SHUT-OFF VALVE
CONN CONNECT(ION) MISC MISCELLANEOUS PRESSURE REDUCING VALVE
CONT CONTINUE(ED)(UATION) DPV DRY PIPE VALVE ASSEMBLY
MTD MOUNTED MAV
CL CENTERLINE AAV AIR VENT (MANUAL/AUTOMATIC)
NC NORMALLY CLOSED
PAV PRE-ACTION VALVE ASSEMBLY
DDC DIRECT DIGITAL CONTROL NIC NOT IN CONTRACT RELIEF VALVE
DEFL DEFLECTION NO NORMALLY OPEN
STRAINER
DN DOWN OAD OUTSIDE AIR DAMPER
DP DEW POINT OC ON CENTER DISTANCE SYMBOLS STRAINER W/ BLOWDOWN
DWDI DOUBLE WIDTH DOUBLE INLET OSA OUTSIDE AIR DV DRAIN VALVE
DWG DRAWING PH PHASE
HB HOSE BIBB
EA EXHAUST AIR PP POLYPROPYLENE A ACCESS PANEL K CAP EXISTING / CAP FOR FUTURE
EAD EXHAUST AIR DAMPER PSI POUNDS PER SQUARE INCH WH WALL HYDRANT
EAT ENTERING AIR TEMPERATURE PVC POLYVINYL CHLORIDE B BELOW GRADE / FLOOR R RELOCATE EXISTING
EDB ENTERING DRY BULB PVS PVC COATED STEEL G GH GROUND HYDRANT
EFF EFFICIENCY R (RAD) RADIUS C CONNECT TO EXISTING X REMOVE EXISTING F&T/IB
STEAM TRAP
EFT ENTERING FLUID TEMPERATURE RA RETURN AIR
ELEC ELECTRIC(AL) RAD RETURN AIR DAMPER E EXISTING TO REMAIN 1 NOTE
ELEV ELEVATION PRESSURE GAUGE
REV REVISION
ENGR ENGINEER RH RELATIVE HUMIDITY PRESSURE/TEMPERATURE TEST PLUG
EQ EQUAL RPM REVOLUTIONS PER MINUTE
EQUIP EQUIPMENT SA SUPPLY AIR MISC. FITTINGS & SYMBOLS THERMOMETER
ESP EXTERNAL STATIC PRESSURE SCFM STANDARD CUBIC FEET PER MINUTE F
EWB ENTERING WET BULB SD SMOKE DAMPER DIRECTION OF FLOW FLOW SWITCH
EWT ENTERING WATER TEMPERATURE SECT SECTION T
DIRECTION OF SLOPE TEMPERATURE TRANSMITTER
EX EXTRACTOR SENS SENSIBLE
PIPE SLEEVE S (SIZE)
EXH EXHAUST SIM SIMILAR SHOCK ARRESTOR
EXIST EXISTING SP STATIC PRESSURE REDUCER V
EXP EXPANSION SPEC SPECIFICATION VACUUM BREAKER
ANCHOR WFM
F DEGREES FAHRENHEIT SQ SQUARE WATER FLOW METER
FC FORWARD CURVED SF SQUARE FOOT(FEET) ELBOW (90°) RPBA
REDUCED PRESSURE BACKFLOW ASSEMBLY
FIG FIGURE SQ IN SQUARE INCH(ES) ELBOW (45°) DCVA
DOUBLE CHECK VALVE ASSEMBLY
FILT FILTER SS STAINLESS STEEL TEE DCDA
FLEX FLEXIBLE STL STEEL DOUBLE CHECK DETECTOR ASSEMBLY
CROSS BWV
FPD FLUID PRESSURE DROP STRUCT STRUCTUR(E)(AL) BACKWATER VALVE
FPM FEET PER MINUTE UG
SWP SINGLE WALL PLENUM UNDERGROUND GATE VALVE W/BOX
FPS FEET PER SECOND SWSI SINGLE WIDTH SINGLE INLET PIPING CONNECTIONS PIV
UNDERGROUND GATE W/POST INDICATOR
FT FEET/FOOT TEMP TEMPERATURE
FTR FINNED TUBE RADIATOR TSP TOTAL STATIC PRESSURE JOINT OR COUPLING POINT OUTSIDE SCREW & YOKE
FU FIXTURE UNIT TYP TYPICAL UNION
FUT FUTURE Y PATTERN BOILER BLOWDOWN VALVE
V VOLTS FLANGED CONNECTION
FV FACE VELOCITY VD VOLUME DAMPER NON-RETURN STOP VALVE
GA GAGE/GAUGE VEL VELOCITY CAP QUICK OPENING BOILER BLOWDOWN VALVE
GAL GALLON VERT VERTICAL PLUG OR BLIND FLANGE
GALV GALVANIZED VFD VARIABLE FREQUENCY DRIVE RISER
GLY GLYCOL VTR VENT THROUGH ROOF ELBOW UP
GPH GALLONS PER HOUR W WIDTH
GPM GALLONS PER MINUTE ELBOW DOWN
WG WATER GAUGE
H HEIGHT WPD WATER PRESSURE DROP TEE UP

BUILDING AND SITE CONSTRUCTION DOCUMENTS


HORIZ HORIZONTAL WTD WATER TEMPERATURE DROP TEE DOWN
HP HORSEPOWER WTR WATER TEMPERATURE RISE HORIZONTAL TEE
HTG HEATING W/ WITH
FLEXIBLE CONNECTION
ID INSIDE(DIAMETER/DIMENSION) W/O WITHOUT
BALL JOINT
MC
MECHANICAL COUPLING

FIRE PROTECTION EQUIPMENT SCHEDULE FIRE PROTECTION DESIGN CRITERIA

HOWARD ELEMENTARY SCHOOL


ITEM DESCRIPTION ELECTRICAL FIRE PROTECTION SPRINKLER DESIGN CRITERIA
CLASSIFIED AS LIGHT HAZARD. SYSTEM TO BE HYDRAULICALLY CALCULATED.
DCDA-1 DOUBLE CHECK DETECTOR ASSEMBLY SYSTEM TO BE WET PIPE EXCEPT FOR AREAS SUBJECT TO FREEZING WHERE DRY HEADS ARE TO BE USED.
475 GPM @ 5 PSIG LOSS

700 HOWARD AVE, EUGENE, OREGON 97404


BASED ON: FEBCO 856
FIRE PROTECTION SYMBOLS

EUGENE SCHOOL DISTRICT


F FIRE PROTECTION
SPR FIRE SPRINKLER
WSP WET STANDPIPE
CSP COMBINATION STANDPIPE

FDC FIRE DEPARTMENT CONNECTION

SRC STANDPIPE ROOF CONNECTION

SO STANDPIPE OUTLET
UPRIGHT SPRINKLER HEAD

ABBREVIATIONS - FIRE PROTECTION


PENDANT SPRINKLER HEAD
FROM FILE: C:\Revit Local Files\13-1532_HES MEP14\13-1532_HES MEP14_stacy.hansen.rvt

SIDEWALL SPRINKLER HEAD


F
FLOW SWITCH

SYMBOLS, LEGENDS AND


S
SUPERVISED SHUT-OFF VALVE

SYMBOLS
A ACCESS PANEL X REMOVE EXISTING

B BELOW GRADE / FLOOR 1 NOTE

FIRE PROTECTION
FIRE PROTECTION SYSTEM TO BE DESIGN-BUILD. REFER TO DIVISION 21 SPECIFICATIONS AND
ARCHITECTURAL COORDINATION DRAWINGS.

REVISIONS:
1336

09/23/2014

NPC
TJL
9/12/2014 4:22:03 PM

ISSUE DATE:
PROJECT #:

CHECKED:
DRAWN:
PRINTED ON:

FP001
2014 PIVOT ARCHITECTURE

GENERAL NOTES:
A. IT SHALL BE THE RERESPONSIBLITY OF THIS CONTRACTOR TO
COORDINATE THE WORK WITH THAT OF ALL OTHER TRADES, INCLUDING
BUT NOT LIMITED TO: ELECTRICAL, FIRE SPRINKLER, HVAC, STRUCTURAL
AND GENERAL ARCHITECTURE.
C

B. IT IS THE INTENTION THAT THE ENTIRE BUILDING WILL BE FULLY


SRPINKLERED IN ACCORDANCE WITH NFPA 13 AND LOCAL FIRE CODE.

C. ALL ZONES WITHIN THIS SCOPE ARE CONSIDERED LIGHT HAZARD


AREAS. PROVIDE FULL COVERAGE AS REQUIRED.
D PROFESS
TERE G I NEE

REGIS

IONA
N

R
18329PE

L
1 2 4 6.2 6.3 6.8 7 7.8 8.2 9 11 11.9 12 12.6 13 13.6 14 14.4 15
OREGON

NIC

r.
ar

J
ch 9
1 9 19

S,
H
LA IN

O
S P. C O L L

EXPIRES 12-31-15

LOST AND FOUND


A115
A

MUSIC ROOM / STAGE


A113

BLDG STORAGE CUSTODIAL

A117 A116

PE OFC/STG
A114

B
ELEC
A118

B.3
B.5
B 6" FP
SEE C031 DCDA-101 2
FOR CONTINUATION BOILER
TOILET TOILET
NOTES:
FIRE A119 1. PROVIDE FIRE SPRINKLERS UNDER THE STAGE.
B104 B112
ALARM
GYM
B.7 BELL
A111 CHANGING TOILET B.8 2. CANOPY SHALL BE PROTECTED BY DRY FIRE SPRINKLER
PRINCIPAL STAFF ROOM B125C SYSTEM.
SECRETARY
B102 CHANGING FIRE PROTECTION ZONE 1
BOYS
A109

B103
GIRLS

B101
A110

VESTIBULE B125D

A100
LACTATION RM C
B111
QUIET
CUST PE CIRCULATION
B105
A106
FAMILY TOILET A112 D
A107 BOYS
GIRLS LIFE SKILLS CLASSROOM CLASSROOM
RECEPTION
B122 B125 B126 B127
HALL B123
B100
A106B WORKROOM
D.9 LOBBY B113 E
TBL STORAGE A101 CONFERENCE

COMMUNITY ROOM
A105 CAFETERIA B110
HEALTH CLOSET

BUILDING AND SITE CONSTRUCTION DOCUMENTS


A103 B106 B109 HALLWAY COMMONS HALLWAY
E.7

A102
MOTOR SKILLS HALLWAY
B114 B119 B124 B130 B128

SENSORY ROOM
CUST VOLUNTEER OFFICE
B115
A104C B117 B107 F
KITCHEN MDF
A104D KITCHEN SMALL GROUP
B120
CLASSROOM CLASSROOM F.2
A104 B116 B131 B129

G.1 G
HEALTH TOILET SOR

HOWARD ELEMENTARY SCHOOL


B108 B121
H
H.2
MEDIA CENTER

700 HOWARD AVE, EUGENE, OREGON 97404


B132

EUGENE SCHOOL DISTRICT


MEDIA WORK RM
B133
PROTECTED FROM ABOVE

STAFF TOILET STAFF TOILET


C103 B140
L SOR SOR
L
C102 B139

M
IDF CUST
CLASSROOM C101 B138

OVERALL FIRST FLOOR PLAN - FIRE


CLASSROOM CLASSROOM CLASSROOM
FROM FILE: C:\Revit Local Files\13-1532_HES MEP14\13-1532_HES MEP14_stacy.hansen.rvt

C109 C107 STORY COVE B144 B146


B135
N SMALL GROUP
OFFICE
N
B136
B134

HALLWAY
COMMONS
COMMONS P
C108 HALLWAY HALLWAY HALLWAY HALLWAY HALLWAY
B145
C110 C106 C100 FIRE PROTECTION ZONE1 B137 B143 B147
P.7

Q Q

PROTECTION
BOYS
CLASSROOM CLASSROOM GIRLS CLASSROOM MULTIPURPOSE CLASSROOM
MULTIPURPOSE GIRLS BOYS B141
C111 C113 B142 B150 B149 B148
C112 C104 C105
R

S S

REVISIONS:
0.9 1.9 3 4.3 5 5.4 6 6.1 7 8 10 11 11.9 12 12.6 13 13.6 14 14.4 15

1336

09/23/2014

NPC
TJL
9/12/2014 4:22:10 PM

ISSUE DATE:
PROJECT #:

CHECKED:
B

DRAWN:
NORTH
1 LEVEL 1 OVERALL PLAN - FIRE PROTECTION
PRINTED ON:

C
1/16" = 1'-0"
FP101
2014 PIVOT ARCHITECTURE

GENERAL NOTES:
A. IT SHALL BE THE RERESPONSIBLITY OF THIS CONTRACTOR TO
COORDINATE THE WORK WITH THAT OF ALL OTHER TRADES, INCLUDING
BUT NOT LIMITED TO: ELECTRICAL, FIRE SPRINKLER, HVAC, STRUCTURAL
AND GENERAL ARCHITECTURE.
C

B. IT IS THE INTENTION THAT THE ENTIRE BUILDING WILL BE FULLY


SRPINKLERED IN ACCORDANCE WITH NFPA 13 AND LOCAL FIRE CODE.

C. ALL ZONES WITHIN THIS SCOPE ARE CONSIDERED LIGHT HAZARD


AREAS. PROVIDE FULL COVERAGE AS REQUIRED.
D PROFESS
TERE G I NEE

REGIS

IONA
N

R
18329PE
1 2 4 6.2 6.3 6.8 7 7.8 8.2 9 11 11.9 12 12.6 13 13.6 14 14.4 15

L
OREGON

NIC

r.
ar

J
ch 9
1 9 19

S,
H
LA IN

O
S P. C O L L

EXPIRES 12-31-15

A
NOTES:
1. COVERED BALCONIES SHALL BE PROTECTED WITH DRY HEAD
SIDEWAY SPRINKLERS.

B.3
GYM
A111
B.5

MECHANICAL EQUIPMENT
PLATFORM
A200

B.7 B.8
FIRE PROTECTION ZONE 2

CLASSROOM
D
BOYS GIRLS MULTIPURPOSE CLASSROOM
B225
B222 B223 B226 B227

D.9 E
CAFETERIA
A103
HALLWAY
HALLWAY COMMONS HALLWAY
E.7

BUILDING AND SITE CONSTRUCTION DOCUMENTS


B219
MECHANICAL EQUIPMENT B224 B230 B228
PLATFORM
A201 HALLWAY
B232 F
HALLWAY
SMALL GROUP CLASSROOM 1 CLASSROOM F.2
B217 WORKROOM
B216 B231 B229
B218

G.1 G

HOWARD ELEMENTARY SCHOOL


SOR
B220 H
H.2
STAFF TOILET
B221

700 HOWARD AVE, EUGENE, OREGON 97404


J

EUGENE SCHOOL DISTRICT


K
STAFF TOILET STAFF TOILET
C203 B240

L SOR SOR L
C202 B239

M
CUST HALLWAY IDF

OVERALL SECOND FLOOR PLAN - FIRE


CLASSROOM
CLASSROOM C201 B235 B238 CLASSROOM CLASSROOM
1 C207
FROM FILE: C:\Revit Local Files\13-1532_HES MEP14\13-1532_HES MEP14_stacy.hansen.rvt

C209 B244
1 B246

N OFFICE OFFICE N
B234 B236

COMMONS
P
HALLWAY COMMONS HALLWAY HALLWAY HALLWAY HALLWAY HALLWAY
B245
C210 C208 C206 C200 B237 B243 B247
P.7

Q Q

PROTECTION
FIRE PROTECTION ZONE 2 GIRLS BOYS
CLASSROOM MULTIPURPOSE CLASSROOM GIRLS BOYS CLASSROOM MULTIPURPOSE CLASSROOM
C211 C212 C213 B242 B241 B250 B249 B248
C204 C205
R

S S

REVISIONS:
0.9 1.9 3 4.3 5 5.4 6 6.1 7 8 10 11 11.9 12 12.6 13 13.6 14 14.4 15

1336

09/23/2014

NPC
TJL
9/12/2014 4:22:17 PM

ISSUE DATE:
PROJECT #:

CHECKED:
B

DRAWN:
NORTH
1 LEVEL 2 OVERALL PLAN - FIRE PROTECTION
PRINTED ON:

C
1/16" = 1'-0" FP102
2014 PIVOT ARCHITECTURE
C
12 12.6 13 13.6 14

E
6.2
6.3 6.8 7
DN MECHANICAL EQUIPMENT
PLATFORM
4
B300

D
E.7

F
D.9 MECHANICAL EQUIPMENT
PLATFORM
F.2 A201

11.9
12 13 13.6 14 B B.3 B.7 D.9

3 SECTOR B2 PARTIAL PLAN - PLUMBING


1/8" = 1'-0" 2 SECTOR B1 PARTIAL PLAN - PLUMBING
1/8" = 1'-0" 1 SECTOR A PARTIAL PLUMBING PLANS
1/8" = 1'-0"

N N

12 12.6 13 13.6 14
MECHANICAL EQUIPMENT
PLATFORM
C300

DN

Q Q
N N

BUILDING AND SITE CONSTRUCTION DOCUMENTS


P
MECHANICAL EQUIPMENT
PLATFORM
B301

P.7

HOWARD ELEMENTARY SCHOOL


S S Q Q

700 HOWARD AVE, EUGENE, OREGON 97404


EUGENE SCHOOL DISTRICT
3 4.3 5 11.9
12 13 13.6 14

5 SECTOR C PARTIAL PLUMBING PLANS


1/8" = 1'-0" 4 SECTOR B3 PARTIAL PLAN - PLUMBING
1/8" = 1'-0"
FROM FILE: C:\Revit Local Files\13-1532_HES MEP14\13-1532_HES MEP14_dany.rachi.rvt

MECHANICAL LOFTS - FIRE


PROTECTION
REVISIONS:
1336

09/23/2014

NPC
TJL
9/12/2014 4:43:48 PM

ISSUE DATE:
PROJECT #:

CHECKED:
DRAWN:
PRINTED ON:

FP103
2014 PIVOT ARCHITECTURE

TO SPRINKLER ZONE 2
C

TO DRY SPRINKLER ZONE


TO SPRINKLER ZONE 1
FLOW SWITCH TERE
D PROFESS
G I NEE

(TYP)

REGIS

IONA
N

R
18329PE

L
OREGON

NIC

r.
ar

J
ch 9
1 9 19
DRY VALVE

S,
H
LA IN
F F

O
S P. C O L L

EXPIRES 12-31-15

S S S FIRE DEPT. TEST


STATION (TYP)
SUPERVISED CONTROL
VALVE (TYP)
FIRE SERVICE BACKFLOW
DEVICE LOCATED IN
MECHANICAL ROOM
GROUND LEVEL
F FIRE DEPT. TEST DRAIN
FIRE SERVICE AND FDC
FDC. SEE CIVIL DWG TERMINATE OUTSIDE
FOR CONTINUATION BUILDING 18" ABOVE GRADE,
TURNED DOWN WITH SPLASH BLOCK

1 FIRE PROTECTION RISER DIAGRAM


NONE

BUILDING AND SITE CONSTRUCTION DOCUMENTS

HOWARD ELEMENTARY SCHOOL


700 HOWARD AVE, EUGENE, OREGON 97404
EUGENE SCHOOL DISTRICT
FROM FILE: C:\Revit Local Files\13-1532_HES MEP14\13-1532_HES MEP14_stacy.hansen.rvt

DETAILS - FIRE PROTECTION


REVISIONS:
1336

09/23/2014

NPC
TJL
9/12/2014 4:22:24 PM

ISSUE DATE:
PROJECT #:

CHECKED:
DRAWN:
PRINTED ON:

FP501

You might also like