READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
• To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
• Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
• Installation and service of luminaires should be performed by a qualified licensed electrician.
• Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation
and any hazards involved. Regular fixture maintenance programs are recommended.
• It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm
water and any mild, non‐abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
• DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been
damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
• Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency
to meet in connection with installation, operation, or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be
referred to Acuity Brands Lighting, Inc.
WARNING WARNING
RISK OF ELECTRIC SHOCK RISK OF BURN
9 Disconnect or turn off power before 9 Allow lamp/fixture to cool before handling.
installation or servicing. Do not touch enclosure or light source.
9 Verify that supply voltage is correct by 9 Follow all manufacturer’s warnings,
comparing it with the luminaire label recommendations and restrictions for: driver
information. type, burning position, mounting
9 Make all electrical and grounded locations/methods, replacement and
connections in accordance with the National recycling.
Electrical Code (NEC) and any applicable
local code requirements.
9 All wiring connections should be capped
with UL approved recognized wire
connectors.
CAUTION CAUTION
RISK OF INJURY RISK OF FIRE
9 Wear gloves and safety glasses at all times 9 Keep combustible and other materials that
when removing luminaire from carton, can burn, away from lamp/lens.
installing, servicing or performing 9 Do not operate in close proximity to
maintenance. persons, combustible materials or
9 Avoid direct eye exposure to the light source substances affected by heat or drying.
while it is on.
LED IMPORTANT SAFETY INSTRUCTIONS
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory
statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and
Conditions, please visit www.acuitybrands.com.
Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls
Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT
Carandini Mark Architectural Lighting Antique Street Lamps Lighting Control & Design
Holophane Peerless Hydrel ROAM
RELOC Renaissance Lighting Tersen Sensor Switch
Winona Lighting Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
Figure 2
GR1925A
1 Introduction GR1932A
1.1 Product Description. Light Emitting Diode (LED)
luminaire.
1.2 Alternate Information Sources. Figure 3
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(740) 345-9631
2 Installation
2.1 Tools and Materials Required.
IM-333-A
4 Pendant Luminaire Installations (Figure 4) Figure 5 – Ceiling Mount
4.1 Mounting
4.1.1 Loosen closure screw and open electrical housing.
(See Figure 1)
4.1.2 Un-hinge electrical cover from luminaire.
4.1.3 Remove plastic cover over wiring chamber inside
the electrical cover.
4.1.4 Back out the pendant set screw far enough to
insure that it will not interfere with the pipe threads.
4.1.5 Remove clear dust cover from pendant entry on
the outside of the electrical cover.
4.1.6 Pull supply wires through pendant entry and thread
electrical cover onto pipe at least (5) full turns until
secure. Mounting structure shall support the full weight GR1928
of the luminaire in accordance with local codes.
4.1.7 Tighten pendant set screw, per torque specified in 5.2 Wiring
Figure 4. 5.2.1 Route supply wires through pipe entries and into
4.1.8 Proceed to Section 4.2 electrical cover wiring chamber. Use wire ties rated
90°C minimum to secure the supply wires to the
Figure 4 – Pendant Mount
electrical cover such that they cannot touch any
components.
5.2.2 Make appropriate supply and ground connections
to the luminaire wires in accordance with local codes.
5.2.3 Re-attach plastic cover over wiring chamber inside
the electrical cover.
5.2.4 Close luminaire and tighten closure screw to
torque specified in Figure 1.
IM-333-A
Figure 10 – Dimming Option 12.4 Electrical Component Replacement
CAUTION
DO NOT USE ABRASIVE CLEANERS ON OPTICAL
SURFACES. THEIR USE MAY RESULT IN THE LOSS
OF OPTICAL EFFICIENCY
CAUTION
THE GLASS OPTIC ASSEMBLY IS A NON-
ACCESSIBLE JOINT FOR LED PETROLUX USED IN
HAZARDOUS LISTED LOCATIONS (HPLED) AND
SHALL NOT BE OPENED. REPLACE WITH NEW,
SUB-ASSEMBLY BELOW ELECTRICAL COVER.
CONTACT YOUR LOCAL HOLOPHANE
REPRESENTATIVE FOR HOLOPHANE APPROVED
REPLACEMENT PARTS
IM-333-A