CRUZE THROUGH
A POWER CUT
AT BEDTIME
U N I N T E R R U P T E D P O W E R S U P P L Y
Automatically switches on during power cuts
and many more.. Note: These companies and brand logos are used herein for identification
purposes only and may be the trademarks of their respective owners.
Float - Boost, CVCC Type
SMF / Flat / Tubular
No of Batteries 6 15 15 15
5A / 7A / 10A (Selectable)
Batteries Dependent
45 Deg C
95% RH - Humidity
55 DB
Dimensions -W x H x D 320 x 625 x 530
Weight 77.5kg 82kg 89.6kg
Class IP20
Ventilation Forced Air Cooled
Reverse Battery
Input Phase Reversal
Mains Low / High Cut
Dc Low Voltage
Dc Over Voltage
Short Circuit Protection
Dead Short Circuit Protection
High Temperature
Mains Input Breaker, Battery Breaker, Electronic
Protection, Fast Acting HRC Fuse in IGBT Circuit at the Ouput of UPS
LCD Display + LED MONOCHROME ALPHANUMERIC LCD + 5 LED'S
BATTERY CHG. / CHARGED
UPS ON
LED Indication OVERLOAD / SHORT CIRCUIT
INDICATIONS BATTERY LOW
PHASE REVERSAL
LCD Indication System Capacity, Input Voltage, Output Voltage, Frequency, Battery Voltage, Battery
UPS On
Manual Bypass
LCD Display Parameters Scroll / Hold
Rating System Rating 6KVA / 72V DC 7.5KVA / 180V DC 10KVA / 180V DC 15KVA / 180V DC
PF 0.7
Configuration 3P + N + E (3 PHASE, 4 WIRES + EARTH)
Output Voltage Setting 400/380V Phase-Phase (230/220V P-N) on Battery
Output Voltage
Regulation On Battery +/-2%
LCD Indication System Capacity, Input Voltage, Output Voltage, Frequency, Battery Voltage, Battery Type, System Settings
UPS On
Manual ByPass
LCD Display Parameters Scroll / Hold
Rating System Rating 5KVA / 72V DC 7.5KVA / 180V DC 10KVA / 180V DC 15KVA / 240V DC 20KVA / 360V DC
PF 0.8
Configuration 3P + N + E (3 PHASE, 4 WIRES + EARTH)
Output Voltage Setting 400/380V Phase-Phase (230/220V P-N) on Battery
Output Voltage Regulation +/-2%
On Battery
Output Frequency on Battery 50 Hz ± 0.5 Hz
Cruze 5.5KVA
(96V - 8 Battery)
Cruze 7.5KVA
(120V - 10 Battery)
Cruze 10KVA
(180V - 15 Battery)
As per typical usage. For light loads, we recommend that the capacity of the UPS to be 1.3 times the rated power of connected loads.
For heavy loads, we recommend the capacity of the UPS to be 3 times the rated power of connected loads. Kindly check the rated power consumption of your appliances before selecting the UPS.
Category Requirement Specifications
Power Rating 5500VA 6000VA 7500VA 10000VA
Input Voltage Mains Mode
(Regulated UPS Mode) 180 to 260 V AC
Input Mains Mode ( Unregulated UPS Mode) 140 to 280 V AC
Frequency 40 to 60 Hz
Input Protection 50A MCB 63A MCB
Sine Wave
Input & Output Connection on Rear Panel 20A - 4 Way Terminal Block 30A - 4 Way Terminal Block
Battery Fuse Internal on PCBA
UPS On UPS , "On"
Battery Low UPS, " Lo"
Mains On MAINS ON, "AC"
Smart Charge/ Boost Charging MAINS ON, SMART CHG, "CH"
Battery Charged/ Float Charge MAINS ON, BATTERY CHARGED, " 99%"
Indications
Overload UPS, " OL"
No Load Shutdown "nL"
Over Temperature Protection UPS , "th"
Short Circuit Under Battery Mode "UPS" Blinking, "OL" Blinking
MCB Trip/ Short Circuit in Mains Mode MAINS ON , " bt"
Low Battery Pre-Alarm One Beep Every 10 sec
Low Battery Continuous Beep for 10 sec
Overload Continuous Beep for 10 sec
Audible Alarms
Continuous Beep for 10 sec
MOVEMENT
No Load Shutdown
POWER CUTS
Protections
Short Circuit
Over Temperature
Battery Reverse Polarity
DURING POWER CUTS YES
YES
YES
Low Battery YES
H E A V Y D U T Y U S A G E L O W R U N N I N G C O S T H I G H E F F I C I E N C Y A N D R E L I A B I L I T Y
Ambient Operating Temperature 0-45 Deg C
Capable of running extremely heavy loads Storage Temperature
Less expensive to run than any generator of similar rating
Environmental
Unique DSP
0-45 design
Deg C uses less components
on a 3 Phase Power supply Humidity 95 % RH Non-Condensing
allowing faster feedback and precise action
Cooling System DC Fan
Audible Noise Less than 55dBA ( at 1m)
Net Weight (Kg) 22.25 23 31.9 44.5
Dimension ( Length x Width x Height ) (mm) 280 X 305 X 380 280 x 305 x 380 280 x 365 x 380
Physical
Display Type LED & 7-Segment Display / LCD Display
Enclosure Metal/ Metal with Plastic Front Panel
Category Parameter Specifications
Power Rating 2000VA 2500VA 3500VA 4000VA 5200VA
Input Voltage Mains Mode
180 to 260 V AC
(Regulated UPS Mode)
Mains Mode ( Unregulated UPS Mode) 100 to 285 V AC
Input
Frequency 40 to 60 Hz
If life never stops during a power cut, why should your equipments?
Input Protection 16A MCB 16A MCB 32A MCB 40A MCB
Input Surge Protection MOV
With the Luminous Pro range of UPS systems, you get an advanced solution
Waveform on Battery Mode Sine Wave
Mains Mode :
that never stops during power
Lower cuts!
Cut Off It's Restoration
Voltage/ the perfectVoltage
solution for you
100 V AC / 115 V AC 140 V AC / 150 V AC
-(UnRegulated UPS Mode )
if you’re running electronic appliances,
Upper Cut Off Voltage /sensitive
Restorationmachinery,
Voltage medical
285 V AC / 270 V AC
-( UnRegulated UPS Mode )
equipment, or have heavy
Voltage power
Lower Cut requirements.
Off Voltage/ Restoration Voltage
180 V AC / 185 V AC
(Regulated UPS Mode)
Upper Cut Off Voltage/ Restoration Voltage
260 V AC / 255 V AC
-( Regulated UPS Mode )
On Battery :
On Battery No Load & at Nominal Battery
220V +/- 2%
Output Voltage
Mains Mode:
Apparent Power 2000VA @ 230V 2500VA @ 230V 3500VA @ 230V 5200VA @ 230V
Rated
On Battery :
Power
Bulb Load (Max) 1680 Watts 2100 Watts 2940 Watts 3360 Watts 4000 Watts
Frequency
Frequency ( on Mains Mode)
WORK NEVER 40 to 60 Hz
STOPS DURING
Frequency ( on Batt Mode) 50 Hz +/- 0.5Hz
On Batt Mode ( at Nominal Load & Nominal
Efficiency > 85% Typical
Battery Input)
THD
Change
Over Time
THD % (on Battery, Linear/Resistive Load)
Transfer Time (Mains to UPS Mode) POWER CUTS <= 5%
< 20 ms ; 10ms Typical
< 20 ms ; 10ms Typical
Retransfer Time ( UPS to Mains Mode)
DC Start Cold Start Yes
H E A V Y D U T Y U S A G E
Charger Current 14A/17A/21A
Battery System ( Nominal Voltage) 24 V DC 36 V DC Capable of running extremely
48 V DC heavy loads 72 V DC
No. of Batteries 2 3 on a 3 Phase Power supply
4 6
Charger Charging Profile Adaptive Battery Charging System
Charging Time 10 -12 hrs Typical
Battery Capacity 120Ah-240Ah
Type of Battery Flat/Tubular or Tubular/VRLA
On/Off Switch on Front Panel Yes
By Pass Switch External Yes
+ Range: 10 – 100 KVA