Carboguard 890MIO

Selection & Specification Data Substrates & Surface Preparation


Generic Type Cycloaliphatic Amine Epoxy MIO General Surfaces must be clean and dry. Employ
adequate methods to remove dirt, dust, oil and
Description Highly chemical resistant epoxy mastic coating all other contaminants that could interfere with
with exceptionally versatile uses in all industrial adhesion of the coating.
markets. Self-priming and suitable for application
over most existing coatings and St2. St3 Steel Sa2½ with a 38-75 surface profile.
prepared substrates. St2, St3 and Sa1 are suitable preparation
methods for mild environments.
Features  Excellent chemical resistance
 Surface tolerant characteristics Galvanized SSPC-SP1 and prime with specific Carboline
 Self-priming and primer/finish capabilities Steel primers as recommend by Carboline
 Very good abrasion resistance
 VOC compliant to current AIM regulations Concrete Concrete must be cured 28 days at 24C and
50% relative humidity or equivalent. Prepare
Color RAL, BS, Munsell and others on request surfaces in accordance with ASTM D4258
Surface Cleaning of Concrete and ASTM D4259
Finish Gloss Abrading Concrete. Voids in concrete may
require surfacing. Prime with Carboguard
Primers Self-priming. May be applied over inorganic zinc 1340.
primers and other tightly adhering coatings. A
mist coat may be required to minimize bubbling Previously Lightly sand or abrade to roughen surface and
over inorganic zinc primers. Do not apply over Painted degloss the surface. Existing paint must attain a
latex coatings. Surfaces minimum 3B rating in accordance with ASTM
D3359 “X-Scribe” adhesion test.
Topcoats Acrylics, Epoxies, Polyurethanes

Dry Film 100-150 micron per coat


Thickness 150-200 microns over light rust and for uniform
gloss over inorganic zincs.
Do not exceed 250 micron in a single coat.
Excessive film thickness over inorganic zincs
may increase damage during shipping or
erection.

Solids Content By Volume: 78%  2%

Theoretical 7,8 m2/l at 100 micron.


Coverage Rate 6,2 m2/l at 125 micron.
Allow for loss in mixing and application

VOC Values As supplied: 204 g/l


These are nominal values and may vary slightly
with color.

Dry Temp. Continuous: 121C


Resistance Non-Continuous: 149C
Discoloration and loss of gloss is observed
above 93°C.

January 2006
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact Carboline Company to
verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no responsibility for
coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE,
EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Carboline and Carboguard
are registered trademarks of Carboline Company.
Carboguard 890MIO

Application Equipment Application Conditions


Spray Application The following spray equipment has been found suitable Condition Material Surface Ambient Humidity
(General) and is available from manufacturers such as Binks, Normal 16-29C 16-29C 16-32C 0-80%
DeVilbiss and Graco.
Minimum 10C 10C 10C 0%
Conventional Pressure pot equipped with dual regulators, 3/8” I.D. Maximum 32C 52C 43C 80%
Spray minimum material hose, .070” I.D. fluid tip and appro-
priate air cap. This product simply requires the substrate temperature to be 3°C above the dew
point. Condensation due to substrate temperatures below the dew point can
Airless Spray Pump Ratio: 30:1 (min.) cause flash rusting on prepared steel and interfere with proper adhesion to the
GPM Output: 3.0 (min.) substrate. Special application techniques may be required above or below normal
Material Hose: 3/8” I.D. (min.) application conditions.
Tip Size: .017”-.021”
Output BAR:
Filter Size:
145-162
60 mesh Curing Schedule
Teflon packings are recommended and available from
the pump manufacturer. Surface Temp. Dry to
& 50% Dry to Recoat Topcoat w/ Final Cure
Brush & Roller Multiple coats may be required to obtain desired Relative Other Finishes
(General) appearance, recommended dry film thickness and Humidity
adequate hiding. Avoid excessive re-brushing or re- 10C 12 Hours 24 Hours 3 Days
rolling.
16C 8 Hours 16 Hours 2 Days
Brush Use a medium bristle brush. 24C 4 Hours 8 Hours 1 Day
32C 2 Hours 4 Hours 16 Hours
Roller Use a short-nap synthetic roller cover with phenolic core.
These times are based on 100-200 microns dry film thickness. Higher film
thickness, insufficient ventilation or cooler temperatures will require longer cure
Mixing & Thinning times and could result in solvent entrapment and premature failure. Excessive
humidity or condensation on the surface during curing can interfere with the cure,
Mixing Power mix separately, then combine and power mix. can cause discoloration and may result in a surface haze. Any haze or blush
DO NOT MIX PARTIAL KITS. must be removed by water washing before recoating. During high humidity
conditions, it is recommended that the application be done while temperatures
Ratio 1:1 Ratio (A to B) are increasing. Maximum recoat/topcoat times are 30 days for epoxies and
90 days for polyurethanes at 24C. If the maximum recoat times have been
Thinning Spray: Up to 12% w/ Thinner 2. exceeded, the surface must be abraded by sweep blasting or sanding prior to the
Brush: Up to 15% w/ Thinner 33. application of additional coats.
Roller: Up to 15% w/ Thinner 33.
Use of thinners other than those supplied or
recommended by Carboline may adversely affect Packaging, Handling & Storage
product performance and void product warranty,
whether expressed or implied. Shipping Weight 5 Liter 20 Liter
(Approximate) 7,25 Kg 29 Kg
Pot Life 3 Hours at 24C.
Pot life ends when coating loses body and begins to Flash Point (Setaflash) Part A: 32C
sag. Pot life times will be less at higher temperatures. Part B: 22C

Storage Temperature
Cleanup & Safety & Humidity
4°-43C Store indoors.
0-100% Relative Humidity

Cleanup Use Thinner 2, Thinner or Acetone. In case of spillage, Shelf Life Part A: 24 months at 24C
absorb and dispose of in accordance with local Part B: 18 months at 24 C
applicable regulations.

Safety Read and follow all caution statements on this product


data sheet and on the MSDS for this product. Employ
normal workmanlike safety precautions. Hypersensitive
persons should wear protective clothing, gloves and use
protective cream on face, hands and all exposed areas.

Ventilation When used in enclosed areas, thorough air circulation


must be used during and after application until the
coating is cured. The ventilation system should be Carboline Europe North
capable of preventing the solvent vapor concentration Braak 1 4704 RJ Roosendaal
from reaching the lower explosion limit for the solvents The Netherlands
used. User should test and monitor exposure levels to Tel.: +31 (0)165 585230
insure all personnel are below guidelines. If not sure or Fax.: +31 (0)165 585232
if not able to monitor levels, use MSHA/NIOSH
approved supplied air respirator.

Caution This product contains flammable solvents. Keep away


from sparks and open flames. All electrical equipment
and installations should be made and grounded in
accordance with the National Electric Code. In areas
where explosion hazards exist, workmen should be
required to use non-ferrous tools and wear conductive
and non-sparking shoes.

January 2006
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior noti ce. User must contact Carboline Company to
verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control. We assume no responsibility for
coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARBOLINE,
EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Carboline and Carboguard
are registered trademarks of Carboline Company.

You might also like