You are on page 1of 9

TO TIMMAPURAM TO GURJANAPALLI

(FLEXIBLE APRON) (FLEXIBLE APRON)


MINIMUM OF 3000 OR CL OF PROPOSED ROAD MINIMUM OF 6000 OR
AS PER ROW AVAILABLE 4500 14000 4500 AS PER ROW AVAILABLE 200
FLOOR APRON BL-L 2000 1500 7000 1500 2000 BL-R FLOOR APRON
125
GUARD STONE WEARING COAT
FRL
3.0 % 2.0 % 2.0 % 3.0 %

750
300
150 COMPACTED EARTH
300 THK. DRY STONE PITCHING OVER 250

EC-R
EC-L

2500
EARTH CUSHION 300mm THK. FLAT STONE EMBEDDED
150 THK. FILTERMEDIA
IN 150mm thk. M15 CONCRETE
300 THK. DRY STONE PITCHING OVER

750
2
1 D/S 150 THK. FILTERMEDIA 450 750 150mm THK. M15 PCC
U/S
300 (min.)

300 (min.)
2 CURTAIN WALL PCC M20

550
B1
1

B2
PCC TOE WALL PCC TOE WALL
IL-2 IL-1
BED LVL SLOPE 1 IN 1000 BED LVL
'A'
100 1650 100
100mm THK. M15 PCC
750

750
TYPICAL CROSS SECTION OF
2000

150 THK. PCC M15

2500
SECTION 1-1 FLOOR APRON FLEXIBLE APRON
CURTAIN WALL(D/S SIDE)
(SCALE-1:30)
PCC CURTAIN WALL (SCALE-1:50) REFERENCE DRAWINGS
PCC CURTAIN WALL DETAILS OF RCC BOX CTL/NH-216/TG/STR/BOX-REIN-004
Length of Return
AS PER SITE Prop.Ch: Flow wall
FRL IL-1 IL-2 A B1 B2 C D E BL-L BL-R EC-L EC-R MISCELLANEOUS DETAILS CTL/NH-216/TG/STR/BOX-MISC-001
Direction
(FLEXIBLE APRON) SCHEDULE LHS RHS (FLEXIBLE APRON)
MINIMUM OF 3000 OR MINIMUM OF 6000 OR
200
34+138 34+092 6.152 3.376 3.451 3.00 2.000 2.000 0.30 0.30 0.35 0.654 0.732 0.327 0.366 L to R 3.400 3.400
AS PER ROW AVAILABLE 4500 4500 AS PER ROW AVAILABLE
FLOOR APRON CL OF PROPOSED ROAD FLOOR APRON 125
2 3

750

2000
COMPACTED EARTH 450 425

TO GURJANAPALLI
300mm THK. FLAT STONE EMBEDDED PROPOSED SEQUENCE OF CONSTRUCTION:-
PCC TOE WALL PCC TOE WALL IN 150mm thk. M15 CONCRETE
2000 1500 7000 1500 2000

800
1. EARTH WORK EXCAVATION
150mm THK. M15 PCC
2. CONFIRMATION OF FOUNDING LEVEL AS MENTIONED IN GFC DRAWING
MONOLITHIC FLY WING

MONOLITHIC FLY WING


2:1 2:1 CURTAIN WALL PCC M20 3. LAYING OF PCC LEVELLING COURSE
RETURN WALL

RETURN WALL
100 1300 100 4. CONSTRUCTION OF BOTTOM SLAB WITH A PORTION OF WEB
100mm THK. M15 PCC
5. CONSTRUCTION OF WEB
TYPICAL CROSS SECTION OF 6. CONSTRUCTION OF TOP SLAB WITH A PORTION OF TOP WEB
1.5:1

1.5:1
7. BACK FILLING BEHIND THE SIDE WALL
CURTAIN WALL(U/S SIDE)
8. LAYING OF WEARING COAT
(SCALE-1:30)
D

PCC CURTAIN WALL PCC CURTAIN WALL 9. PLACING OF SIDL

1 U/S D/S 1
10350

CL OF CULVERT
A

FLOOR APRON FLOOR APRON

FLEXIBLE APRON FLEXIBLE APRON


D

EARTH CUSHION
MONOLITHIC FLY WING

MONOLITHIC FLY WING


TO TIMMAPURAM
RETURN WALL

RETURN WALL
BOX TOP LVL

C
150 X 150
HAUNCH (TYP.)

B1 / B2
D A D
600 THK.
FILTER MEDIA
2 3 PLAN
(SCALE-1:50)

E
PCC M15
VIEW 3 -3
(SCALE-1:40)
300mm THK. FLAT STONE NOTES:
CL OF CULVERT APRON EMBEDDED IN 01. ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METERS UNLESS MENTIONED OTHERWISE .
TO TIMMAPURAM TO GURJANAPALLI 150 THK. CONCRETE (M15) INVERT LVL
GUARD STONE 02. DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
D 03. GRADE OF CONCRETE:
CONSTRUCTION JOINT EQ (i) RCC BOX...................................M30
EQ EQ (ii) PCC PARAPET.........................M30
(iii) RCC RETURN WALL...............M30

100
HAUNCH 150 X 150(TYP.)

100
1200
EARTH CUSHION (iv) PCC LEVELING COURSE.......M15

04. GRADE OF UNTENSIONED STEEL SHALL BE Fe 500D, CONFORMING TO IS: 1786


BOX TOP LVL 150mm THK. PCC M15 150mm THK. PCC M15
05. 600mm FILTER MEDIA SHALL BE PROVIDED BEHIND RCC BOX AND RETURN WALL.

E
1 LEVELING COURSE
COMPACTED EARTH COMPACTED EARTH 06. THE BACK FILL MATERIAL BEHIND RCC BOX / RETAINING WALL SHALL HAVE
1 FOLLOWING PROPERTIES =2.0 T/Cum.
100 300 DETAILS AT JUNCTION OF 07. SEISMIC ZONE - II
1.5 DETAIL-A
1 150 X 150 (SCALE-1:20) BASE SLAB AND SIDE WALL
1.5
HAUNCH (TYP.) 1 (SCALE-1:20)
WEEP HOLES AT 9. FLOW DIRECTION SHOWN IN THE PLAN IS INDICATIVE ONLY, BED PROTECTION FOR
200
UPSTREAM AND DOWN STREAM SHALL BE BASED ON THE FLOW DIRECTION THE SITE.
1500c/c STAGGERED
10. FLEXIBLE APRON SHALL BE PROVIDED BASED ON SITE CONDITION AND
SHALL BE DECIDED BY ENGINEER-IN-CHARGE WHEREVER ROCK IS
AVAILABLE AT TOP LEVEL FLEXIBLE APRON SHALL BE DISPENSED.
TOPSLAB

500
11. BACK FILLING SHALL BE DONE SIMULTANEOUSLY ON BOTH SIDE OF BOX.

C
INVERT LVL PCC M20 12. DRAWING SHALL BE READ IN CONJUCTION WITH RELEVENT APPROVED HIGHWAY DRAWING

650
EQ FOR FRL,INVERT LEVEL,GL, CROSS SLOPE,LONGITUDINAL GRADIENT,
MONOLITHIC EQ EQ ROAD WAY DETAILS ETC.
FLY WING ** SHEAR KEY IS NOT SHOWN 13. PITCHING / REVETMENT ON SLOPES TO BE PROVIDED AS PER MORTH SPECIFICATION.

100
RETURN WALL FOR CLARITY 14. IF BC/CLAYEY SOIL ENCOUNTERED AS FOUNDING SOIL, THEN 900mm. DEPTH OF SOIL
HAUNCH 150 X 150(TYP.)
100 150

VIEW 2 -2 PCC M15 D BELOW FOUNDATION TO BE REMOVED & FILLED BY METAL / BOULDRES WITH SAND AS
(SCALE-1:40) CONSTRUCTION JOINT PER SP-13.
15. STRUCTURE HAS BEEN DESIGNED FOR
500 DETAILS AT JUNCTION OF i) ONE LANE, TWO LANE AND THREE LANES OF CLASS A
PCC M15 ii) ONE LANE OF CLASS 70R + ONE LANE OF CLASS A
TOP SLAB AND SIDE WALL iii) ONE LANE OF 40R BOGIE + ONE LAYER OF CLASS 1
DETAILS OF TOE WALL (SCALE-1:20)
16. CONSTRUCTION JOINTS:-
SCALE 1:10
THE LOCATION AND PROVISION OF CONSTRUCTION JOINTS SHALL BE AS PER THE
DRAWING AND THE SAME SHALL BE APPROVED BY THE ENGINEER-IN-CHARGE.
Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
GENERAL ARRANGEMENT DETAILS OF
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout, BOX CULVERT AT CH : 34+092
D:\KAKINADU\CULVERTS\34+092-BOX

(Ministry of Shipping,Road Transport & Highways)


Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:33pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED. M/s . SMART SERVICE PVT LTD.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers, PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056
ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- 18
TO TIMMAPURAM TO GURJANAPALLI
(FLEXIBLE APRON) (FLEXIBLE APRON)
MINIMUM OF 3000 OR CL OF PROPOSED ROAD MINIMUM OF 6000 OR
AS PER ROW AVAILABLE 4500 14000 4500 AS PER ROW AVAILABLE 200
FLOOR APRON BL-L 2000 1500 7000 1500 2000 BL-R FLOOR APRON
125
GUARD STONE WEARING COAT
FRL
3.0 % 5.0 % 5.0 % 3.0 %

750
300
150 COMPACTED EARTH
300 THK. DRY STONE PITCHING OVER 250

EC-R
EC-L

2500
EARTH CUSHION 300mm THK. FLAT STONE EMBEDDED
150 THK. FILTERMEDIA
IN 150mm thk. M15 CONCRETE
300 THK. DRY STONE PITCHING OVER

750
2
1 D/S 150 THK. FILTERMEDIA 450 750 150mm THK. M15 PCC
U/S
300 (min.)

300 (min.)
2 CURTAIN WALL PCC M20

550
B1
1

B2
PCC TOE WALL PCC TOE WALL
IL-2 IL-1
BED LVL SLOPE 1 IN 1000(MIN) BED LVL
'A'
100 1650 100
100mm THK. M15 PCC
750

750
TYPICAL CROSS SECTION OF
2000 150 THK. PCC M15

2500
SECTION 1-1 FLOOR APRON FLEXIBLE APRON
CURTAIN WALL(D/S SIDE)
(SCALE-1:30)
PCC CURTAIN WALL (SCALE-1:50) REFERENCE DRAWINGS
PCC CURTAIN WALL DETAILS OF RCC BOX CTL/NH-216/TG/STR/BOX-REIN-003a
Length of Return
AS PER SITE Prop.Ch: Flow wall
FRL IL-1 IL-2 A B1 B2 C D E BL-L BL-R EC-L EC-R MISCELLANEOUS DETAILS CTL/NH-216/TG/STR/BOX-MISC-001
Direction
(FLEXIBLE APRON) SCHEDULE LHS RHS (FLEXIBLE APRON)
200
MINIMUM OF 3000 OR 36+017 35+960 5.800 2.609 2.693 5.00 2.000 2.000 0.50 0.50 0.55 1.094 1.262 0.547 0.631 L to R 3.400 3.400 MINIMUM OF 6000 OR
AS PER ROW AVAILABLE 4500 4500 AS PER ROW AVAILABLE
FLOOR APRON CL OF PROPOSED ROAD FLOOR APRON 125
2 3

750

2000
COMPACTED EARTH 450 425

TO GURJANAPALLI
300mm THK. FLAT STONE EMBEDDED PROPOSED SEQUENCE OF CONSTRUCTION:-
PCC TOE WALL PCC TOE WALL IN 150mm thk. M15 CONCRETE
2000 1500 7000 1500 2000

800
1. EARTH WORK EXCAVATION
150mm THK. M15 PCC
2. CONFIRMATION OF FOUNDING LEVEL AS MENTIONED IN GFC DRAWING
MONOLITHIC FLY WING

MONOLITHIC FLY WING


2:1 2:1 CURTAIN WALL PCC M20
3. LAYING OF PCC LEVELLING COURSE
RETURN WALL

RETURN WALL
100 1300 100 4. CONSTRUCTION OF BOTTOM SLAB WITH A PORTION OF WEB
100mm THK. M15 PCC
5. CONSTRUCTION OF WEB
TYPICAL CROSS SECTION OF 6. CONSTRUCTION OF TOP SLAB WITH A PORTION OF TOP WEB
1.5:1

1.5:1
7. BACK FILLING BEHIND THE SIDE WALL
CURTAIN WALL(U/S SIDE)
8. LAYING OF WEARING COAT
(SCALE-1:30)
D
PCC CURTAIN WALL PCC CURTAIN WALL 9. PLACING OF SIDL

1 U/S D/S 1
12350

CL OF CULVERT
A

FLOOR APRON FLOOR APRON

FLEXIBLE APRON FLEXIBLE APRON


D

EARTH CUSHION
MONOLITHIC FLY WING

MONOLITHIC FLY WING


TO TIMMAPURAM
RETURN WALL

RETURN WALL
BOX TOP LVL

C
150 X 150
HAUNCH (TYP.)

B1 / B2
D A D
600 THK.
FILTER MEDIA
2 3 PLAN
(SCALE-1:50)

E
PCC M15
VIEW 3 -3
(SCALE-1:40)
300mm THK. FLAT STONE NOTES:
CL OF CULVERT APRON EMBEDDED IN 01. ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METERS UNLESS MENTIONED OTHERWISE .
TO TIMMAPURAM TO GURJANAPALLI 150 THK. CONCRETE (M15) INVERT LVL
GUARD STONE 02. DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
D 03. GRADE OF CONCRETE:
CONSTRUCTION JOINT EQ (i) RCC BOX...................................M30
EQ EQ (ii) PCC PARAPET.........................M30
(iii) RCC RETURN WALL...............M30

100
HAUNCH 150 X 150(TYP.)

100
1200
(iv) PCC LEVELING COURSE.......M15
EARTH CUSHION
04. GRADE OF UNTENSIONED STEEL SHALL BE Fe 500D, CONFORMING TO IS: 1786
BOX TOP LVL 150mm THK. PCC M15 150mm THK. PCC M15
05. 600mm FILTER MEDIA SHALL BE PROVIDED BEHIND RCC BOX AND RETURN WALL.

E
1 LEVELING COURSE
COMPACTED EARTH COMPACTED EARTH 06. THE BACK FILL MATERIAL BEHIND RCC BOX / RETAINING WALL SHALL HAVE
1 FOLLOWING PROPERTIES =2.0 T/Cum.
100 300 DETAILS AT JUNCTION OF 07. SEISMIC ZONE - II
1.5 DETAIL-A
1 150 X 150 (SCALE-1:20) BASE SLAB AND SIDE WALL
1.5
HAUNCH (TYP.) 1 (SCALE-1:20)
WEEP HOLES AT 9. FLOW DIRECTION SHOWN IN THE PLAN IS INDICATIVE ONLY, BED PROTECTION FOR
200
UPSTREAM AND DOWN STREAM SHALL BE BASED ON THE FLOW DIRECTION THE SITE.
1500c/c STAGGERED
10. FLEXIBLE APRON SHALL BE PROVIDED BASED ON SITE CONDITION AND
SHALL BE DECIDED BY ENGINEER-IN-CHARGE WHEREVER ROCK IS
AVAILABLE AT TOP LEVEL FLEXIBLE APRON SHALL BE DISPENSED.
TOPSLAB

500
11. BACK FILLING SHALL BE DONE SIMULTANEOUSLY ON BOTH SIDE OF BOX.

C
INVERT LVL PCC M20 12. DRAWING SHALL BE READ IN CONJUCTION WITH RELEVENT APPROVED HIGHWAY DRAWING

650
EQ FOR FRL,INVERT LEVEL,GL, CROSS SLOPE,LONGITUDINAL GRADIENT,
MONOLITHIC EQ EQ ROAD WAY DETAILS ETC.
FLY WING ** SHEAR KEY IS NOT SHOWN 13. PITCHING / REVETMENT ON SLOPES TO BE PROVIDED AS PER MORTH SPECIFICATION.

100
RETURN WALL FOR CLARITY 14. IF BC/CLAYEY SOIL ENCOUNTERED AS FOUNDING SOIL, THEN 900mm. DEPTH OF SOIL
HAUNCH 150 X 150(TYP.)
100 150

VIEW 2 -2 PCC M15 D BELOW FOUNDATION TO BE REMOVED & FILLED BY METAL / BOULDRES WITH SAND AS
(SCALE-1:40) CONSTRUCTION JOINT PER SP-13.
15. STRUCTURE HAS BEEN DESIGNED FOR
500 DETAILS AT JUNCTION OF i) ONE LANE, TWO LANE AND THREE LANES OF CLASS A
PCC M15 ii) ONE LANE OF CLASS 70R + ONE LANE OF CLASS A
TOP SLAB AND SIDE WALL iii) ONE LANE OF 40R BOGIE + ONE LAYER OF CLASS 1
DETAILS OF TOE WALL (SCALE-1:20)
16. CONSTRUCTION JOINTS:-
SCALE 1:10
THE LOCATION AND PROVISION OF CONSTRUCTION JOINTS SHALL BE AS PER THE
DRAWING AND THE SAME SHALL BE APPROVED BY THE ENGINEER-IN-CHARGE.
Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
GENERAL ARRANGEMENT DETAILS OF
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout, BOX CULVERT AT CH : 35+960
D:\KAKINADU\CULVERTS\35+960-BOX

(Ministry of Shipping,Road Transport & Highways)


Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:33pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers,
M/s . SMART SERVICE PVT LTD. PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056 ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- 19
(FLEXIBLE APRON) (FLEXIBLE APRON) TO TIMMAPURAM TO GURJANAPALLI
MINIMUM OF 3000 OR CL OF PROPOSED ROAD MINIMUM OF 6000 OR
AS PER ROW AVAILABLE 4500(SQ)/5710(SK) 14000 4500(SQ)/5710(SK) AS PER ROW AVAILABLE
FLOOR APRON 572(SQ) 2096(SQ) FLOOR APRON 200
2000 1500 7000 1500 2000
725.87(SK) 2659.86(SK)
WEARING COAT 125
5.571
GUARD STONE
3.0 % 7.0 % 7.0 % 3.0 %
250 250

750
300 THK. DRY STONE PITCHING OVER

1048
150 COMPACTED EARTH

286
150 THK. FILTERMEDIA EARTH CUSHION

2500
300mm THK. FLAT STONE EMBEDDED
300 THK. DRY STONE PITCHING OVER
IN 150mm thk. M15 CONCRETE

750
150 THK. FILTERMEDIA
U/S D/S
300 (min.)

300 (min.)
450 750 150mm THK. M15 PCC
2

2000

2000
1 2 CURTAIN WALL PCC M20
PCC TOE WALL PCC TOE WALL

550
BED LVL 2.375 1 BED LVL
SLOPE 1 IN 1000 2.313
'A'

100 1650 100


750

750
2000 100mm THK. M15 PCC

150 THK. PCC M15 TYPICAL CROSS SECTION OF

2500
SECTION 1-1 FLOOR APRON FLEXIBLE APRON CURTAIN WALL(D/S SIDE)
PCC CURTAIN WALL (SCALE-1:50) (SCALE-1:30)
PCC CURTAIN WALL REFERENCE DRAWINGS
DETAILS OF RCC BOX CTL/NH-216/TG/STR/BOX-REIN-003b
MISCELLANEOUS DETAILS CTL/NH-216/TG/STR/BOX-MISC-001
200

2
125
CL OF PROPOSED ROAD
3

750
MONOLITHIC FLY WING

2000
COMPACTED EARTH 450 425
RETURN WALL

300mm THK. FLAT STONE EMBEDDED PROPOSED SEQUENCE OF CONSTRUCTION:-


2000 1500 7000 1500 2000
IN 150mm thk. M15 CONCRETE

800
1. EARTH WORK EXCAVATION
150mm THK. M15 PCC
2. CONFIRMATION OF FOUNDING LEVEL AS MENTIONED IN GFC DRAWING
CURTAIN WALL PCC M20
3. LAYING OF PCC LEVELLING COURSE
14000(SQ) 100 1300 100 4. CONSTRUCTION OF BOTTOM SLAB WITH A PORTION OF WEB
FLEXIBLE APRON 100mm THK. M15 PCC

TO TIMMAPURAM
17766(SK) 5. CONSTRUCTION OF WEB
TYPICAL CROSS SECTION OF 6. CONSTRUCTION OF TOP SLAB WITH A PORTION OF TOP WEB
7. BACK FILLING BEHIND THE SIDE WALL
CURTAIN WALL(U/S SIDE)
8. LAYING OF WEARING COAT
12350

(SCALE-1:30) 9. PLACING OF SIDL


FLOOR APRON
1 (FLEXIBLE APRON)
5000

U/S
MINIMUM OF 6000 OR
AS PER ROW AVAILABLE
CL OF CULVERT
PCC CURTAIN WALL
MONOLITHIC FLY WING

3940

MONOLITHIC FLY WING


1.5:1

RETURN WALL

RETURN WALL
EARTH CUSHION

500
BOX TOP LVL
2:1

PCC TOE WALL


FLEXIBLE APRON 150 X 150
TO GURJANAPALLI

HAUNCH (TYP.)

12350

2000
(FLEXIBLE APRON) FLOOR APRON
1 500 5000(SQ) 500
MINIMUM OF 3000 OR D/S 3940(SK)
AS PER ROW AVAILABLE 600 THK.
FILTER MEDIA

PCC CURTAIN WALL

MONOLITHIC FLY WING


NOTES:

1.5:1
RETURN WALL
01. ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METERS UNLESS MENTIONED OTHERWISE .

550
PCC M15 02. DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
VIEW 3 -3 03. GRADE OF CONCRETE:
(SCALE-1:40)
2:1 (i) RCC BOX...................................M30
(ii) PCC PARAPET.........................M30
3 (iii) RCC RETURN WALL...............M30
PCC TOE WALL TOPSLAB (iv) PCC LEVELING COURSE.......M15

LHS 3450 LHS 3450 PLAN EQ


RHS 3450 2 CL OF CULVERT RHS 3450 (SCALE-1:50) EQ EQ 04. GRADE OF UNTENSIONED STEEL SHALL BE Fe 500D, CONFORMING TO IS: 1786
GUARD STONE 05. 600mm FILTER MEDIA SHALL BE PROVIDED BEHIND RCC BOX AND RETURN WALL.

100
HAUNCH 150 X 150(TYP.) 06. THE BACK FILL MATERIAL BEHIND RCC BOX / RETAINING WALL SHALL HAVE
TO TIMMAPURAM FOLLOWING PROPERTIES =2.0 T/Cum.
TO GURJANAPALLI CONSTRUCTION JOINT 07. SEISMIC ZONE - II

DETAILS AT JUNCTION OF
EARTH CUSHION TOP SLAB AND SIDE WALL 9. FLOW DIRECTION SHOWN IN THE PLAN IS INDICATIVE ONLY, BED PROTECTION FOR
(SCALE-1:20) UPSTREAM AND DOWN STREAM SHALL BE BASED ON THE FLOW DIRECTION THE SITE.
300

150 BOX TOP LVL 10. FLEXIBLE APRON SHALL BE PROVIDED BASED ON SITE CONDITION AND
SHALL BE DECIDED BY ENGINEER-IN-CHARGE WHEREVER ROCK IS
200 AVAILABLE AT TOP LEVEL FLEXIBLE APRON SHALL BE DISPENSED.
300mm THK. FLAT STONE
APRON EMBEDDED IN 11. BACK FILLING SHALL BE DONE SIMULTANEOUSLY ON BOTH SIDE OF BOX.
1.5 INVERT LVL
1 150 X 150 150 THK. CONCRETE (M15) 12. DRAWING SHALL BE READ IN CONJUCTION WITH RELEVENT APPROVED HIGHWAY DRAWING
1.5 FOR FRL,INVERT LEVEL,GL, CROSS SLOPE,LONGITUDINAL GRADIENT,
HAUNCH (TYP.) 1 ROAD WAY DETAILS ETC.

500
WEEP HOLES AT CONSTRUCTION JOINT EQ
PCC M20 EQ EQ 13. PITCHING / REVETMENT ON SLOPES TO BE PROVIDED AS PER MORTH SPECIFICATION.
1500c/c STAGGERED

650
14. IF BC/CLAYEY SOIL ENCOUNTERED AS FOUNDING SOIL, THEN 900mm. DEPTH OF SOIL

100
HAUNCH 150 X 150(TYP.) BELOW FOUNDATION TO BE REMOVED & FILLED BY METAL / BOULDRES WITH SAND AS

100
PER SP-13.
1200

15. STRUCTURE HAS BEEN DESIGNED FOR


100 150

i) ONE LANE, TWO LANE AND THREE LANES OF CLASS A


INVERT LVL 150mm THK. PCC M15 150mm THK. PCC M15
ii) ONE LANE OF CLASS 70R + ONE LANE OF CLASS A
1 LEVELING COURSE iii) ONE LANE OF 40R BOGIE + ONE LAYER OF CLASS 1
300 COMPACTED EARTH COMPACTED EARTH
** SHEAR KEY IS NOT SHOWN 1 500 16. CONSTRUCTION JOINTS:-
DETAILS AT JUNCTION OF THE LOCATION AND PROVISION OF CONSTRUCTION JOINTS SHALL BE AS PER THE
FOR CLARITY 100 300 DETAIL-A PCC M15
VIEW 2 -2 PCC M15 BASE SLAB AND SIDE WALL DRAWING AND THE SAME SHALL BE APPROVED BY THE ENGINEER-IN-CHARGE.
(SCALE-1:40) (SCALE-1:20) DETAILS OF TOE WALL (SCALE-1:20)
SCALE 1:10 SCHEDULE CHAINAGE AS PER CA CH:36+491
Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
GENERAL ARRANGEMENT DETAILS OF
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout, BOX CULVERT AT CH : 36+430
D:\KAKINADU\CULVERTS\36+430-BOX

(Ministry of Shipping,Road Transport & Highways)


Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:34pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers,
M/s . SMART SERVICE PVT LTD. PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056 ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- 20
TO TIMMAPURAM TO GURJANAPALLI
(FLEXIBLE APRON) (FLEXIBLE APRON)
MINIMUM OF 6000 OR CL OF PROPOSED ROAD MINIMUM OF 3000 OR
AS PER ROW AVAILABLE 4500 14000 4500 AS PER ROW AVAILABLE 200
FLOOR APRON BL-L 2000 1500 7000 1500 2000 BL-R FLOOR APRON
125
WEARING COAT GUARD STONE
FRL
3.0 % 2.0 % 2.0 % 3.0 %

750
300
150 COMPACTED EARTH
250 300 THK. DRY STONE PITCHING OVER

EC-R
EC-L

2500
EARTH CUSHION 300mm THK. FLAT STONE EMBEDDED
150 THK. FILTERMEDIA
IN 150mm thk. M15 CONCRETE
300 THK. DRY STONE PITCHING OVER

750
2
150 THK. FILTERMEDIA 450 750 150mm THK. M15 PCC
D/S 1 U/S
300 (min.)

300 (min.)
2 CURTAIN WALL PCC M20

550
B1
1

B2
PCC TOE WALL PCC TOE WALL
IL-1 IL-2
BED LVL SLOPE 1 IN 1000(MIN) BED LVL
'A'
100 1650 100
100mm THK. M15 PCC
750

750
TYPICAL CROSS SECTION OF

2000
150 THK. PCC M15
2500

FLEXIBLE APRON FLOOR APRON SECTION 1-1 CURTAIN WALL(D/S SIDE)


(SCALE-1:30)
(SCALE-1:50) PCC CURTAIN WALL REFERENCE DRAWINGS
PCC CURTAIN WALL DETAILS OF RCC BOX CTL/NH-216/TG/STR/BOX-REIN-004
Length of Return
AS PER SITE Prop.Ch: Flow wall
FRL IL-1 IL-2 A B1 B2 C D E BL-L BL-R EC-L EC-R MISCELLANEOUS DETAILS CTL/NH-216/TG/STR/BOX-MISC-001
Direction
(FLEXIBLE APRON) SCHEDULE LHS RHS (FLEXIBLE APRON)
MINIMUM OF 6000 OR MINIMUM OF 3000 OR
200
37+387 37+320 6.966 3.706 3.820 3.00 2.000 2.000 0.30 0.30 0.35 1.700 1.472 0.850 0.736 R to L 3.400 3.400
AS PER ROW AVAILABLE 4500 4500 AS PER ROW AVAILABLE
FLOOR APRON CL OF PROPOSED ROAD FLOOR APRON 125
3 2

750

2000
COMPACTED EARTH 450 425

TO GURJANAPALLI
300mm THK. FLAT STONE EMBEDDED PROPOSED SEQUENCE OF CONSTRUCTION:-
PCC TOE WALL PCC TOE WALL IN 150mm thk. M15 CONCRETE
2000 1500 7000 1500 2000

800
1. EARTH WORK EXCAVATION
150mm THK. M15 PCC
2. CONFIRMATION OF FOUNDING LEVEL AS MENTIONED IN GFC DRAWING
MONOLITHIC FLY WING

MONOLITHIC FLY WING


2:1 2:1 CURTAIN WALL PCC M20 3. LAYING OF PCC LEVELLING COURSE
RETURN WALL

RETURN WALL
100 1300 100 4. CONSTRUCTION OF BOTTOM SLAB WITH A PORTION OF WEB
100mm THK. M15 PCC
5. CONSTRUCTION OF WEB
TYPICAL CROSS SECTION OF 6. CONSTRUCTION OF TOP SLAB WITH A PORTION OF TOP WEB
1.5:1

1.5:1
7. BACK FILLING BEHIND THE SIDE WALL
CURTAIN WALL(U/S SIDE)
8. LAYING OF WEARING COAT
(SCALE-1:30)

D
PCC CURTAIN WALL PCC CURTAIN WALL 9. PLACING OF SIDL

1 D/S U/S 1

10350
CL OF CULVERT

A
FLOOR APRON FLOOR APRON

FLEXIBLE APRON FLEXIBLE APRON

D
EARTH CUSHION
MONOLITHIC FLY WING

MONOLITHIC FLY WING


TO TIMMAPURAM
RETURN WALL

RETURN WALL
BOX TOP LVL

C
150 X 150
HAUNCH (TYP.)

B1 / B2
D A D
600 THK.
FILTER MEDIA
PLAN 3 2
(SCALE-1:50)

E
PCC M15
VIEW 3 -3
(SCALE-1:40)
300mm THK. FLAT STONE NOTES:
CL OF CULVERT APRON EMBEDDED IN 01. ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METERS UNLESS MENTIONED OTHERWISE .
TO TIMMAPURAM TO GURJANAPALLI 150 THK. CONCRETE (M15) INVERT LVL
GUARD STONE 02. DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
D 03. GRADE OF CONCRETE:
CONSTRUCTION JOINT EQ (i) RCC BOX...................................M30
EQ EQ (ii) PCC PARAPET.........................M30
(iii) RCC RETURN WALL...............M30

100
HAUNCH 150 X 150(TYP.)

100
1200
(iv) PCC LEVELING COURSE.......M15
EARTH CUSHION
04. GRADE OF UNTENSIONED STEEL SHALL BE Fe 500D, CONFORMING TO IS: 1786
BOX TOP LVL 150mm THK. PCC M15 150mm THK. PCC M15
05. 600mm FILTER MEDIA SHALL BE PROVIDED BEHIND RCC BOX AND RETURN WALL.

E
1 LEVELING COURSE
COMPACTED EARTH COMPACTED EARTH 06. THE BACK FILL MATERIAL BEHIND RCC BOX / RETAINING WALL SHALL HAVE
1 FOLLOWING PROPERTIES =2.0 T/Cum.
100 300 DETAILS AT JUNCTION OF 07. SEISMIC ZONE - II
1.5 DETAIL-A
1 150 X 150 (SCALE-1:20) BASE SLAB AND SIDE WALL
1.5
HAUNCH (TYP.) 1 (SCALE-1:20)
WEEP HOLES AT 9. FLOW DIRECTION SHOWN IN THE PLAN IS INDICATIVE ONLY, BED PROTECTION FOR
200
MONOLITHIC UPSTREAM AND DOWN STREAM SHALL BE BASED ON THE FLOW DIRECTION THE SITE.
1500c/c STAGGERED
FLY WING 10. FLEXIBLE APRON SHALL BE PROVIDED BASED ON SITE CONDITION AND
RETURN WALL SHALL BE DECIDED BY ENGINEER-IN-CHARGE WHEREVER ROCK IS
AVAILABLE AT TOP LEVEL FLEXIBLE APRON SHALL BE DISPENSED.
TOPSLAB

500
11. BACK FILLING SHALL BE DONE SIMULTANEOUSLY ON BOTH SIDE OF BOX.

C
INVERT LVL PCC M20 12. DRAWING SHALL BE READ IN CONJUCTION WITH RELEVENT APPROVED HIGHWAY DRAWING

650
EQ FOR FRL,INVERT LEVEL,GL, CROSS SLOPE,LONGITUDINAL GRADIENT,
EQ EQ ROAD WAY DETAILS ETC.
** SHEAR KEY IS NOT SHOWN 13. PITCHING / REVETMENT ON SLOPES TO BE PROVIDED AS PER MORTH SPECIFICATION.

100
FOR CLARITY HAUNCH 150 X 150(TYP.) 14. IF BC/CLAYEY SOIL ENCOUNTERED AS FOUNDING SOIL, THEN 900mm. DEPTH OF SOIL
100 150

VIEW 2 -2 PCC M15 D BELOW FOUNDATION TO BE REMOVED & FILLED BY METAL / BOULDRES WITH SAND AS
(SCALE-1:40) CONSTRUCTION JOINT PER SP-13.
15. STRUCTURE HAS BEEN DESIGNED FOR
500 DETAILS AT JUNCTION OF i) ONE LANE, TWO LANE AND THREE LANES OF CLASS A
PCC M15 ii) ONE LANE OF CLASS 70R + ONE LANE OF CLASS A
TOP SLAB AND SIDE WALL iii) ONE LANE OF 40R BOGIE + ONE LAYER OF CLASS 1
DETAILS OF TOE WALL (SCALE-1:20)
16. CONSTRUCTION JOINTS:-
SCALE 1:10
THE LOCATION AND PROVISION OF CONSTRUCTION JOINTS SHALL BE AS PER THE
DRAWING AND THE SAME SHALL BE APPROVED BY THE ENGINEER-IN-CHARGE.
Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., GENERAL ARRANGEMENT DETAILS OF
M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout, BOX CULVERT AT CH : 37+320
D:\KAKINADU\CULVERTS\37+320-BOX

(Ministry of Shipping,Road Transport & Highways)


Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:34pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers,
M/s . SMART SERVICE PVT LTD. PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056 ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- 21
(FLEXIBLE APRON) (FLEXIBLE APRON) TO TIMMAPURAM TO GURJANAPALLI
MINIMUM OF 3000 OR LC OF PROPOSED ROAD MINIMUM OF 6000 OR
AS PER ROW AVAILABLE 4500(SQ)/5365(SK) 14000 4500(SQ)/5365(SK) AS PER ROW AVAILABLE
FLOOR APRON 2240(SQ) 1964(SQ) FLOOR APRON 200
2000 1500 7000 1500 2000
2670.89(SK) 2341.80(SK)
WEARING COAT 125
6.944
3.0 % 3.0 % GUARD STONE
2.0 % 2.0 %
250 250

750
300 THK. DRY STONE PITCHING

1120
150 COMPACTED EARTH

982
EARTH CUSHION OVER 150 THK. FILTER MEDIA

2500
300mm THK. FLAT STONE EMBEDDED
300 THK. DRY STONE PITCHING OVER
IN 150mm thk. M15 CONCRETE

750
150 THK. FILTERMEDIA
U/S D/S
300 (min.)

300 (min.)
450 750 150mm THK. M15 PCC
2

2000

2000
2 1 CURTAIN WALL PCC M20
PCC TOE WALL PCC TOE WALL

550
BED LVL
1 3.402 BED LVL
3.464 SLOPE 1 IN 1000 'A'

100 1650 100


750

750
100mm THK. M15 PCC
2000

150 THK. PCC M15 TYPICAL CROSS SECTION OF

2500
FLEXIBLE APRON FLOOR APRON SECTION 1-1 CURTAIN WALL(D/S SIDE)
(SCALE-1:50) PCC CURTAIN WALL (SCALE-1:30)
PCC CURTAIN WALL REFERENCE DRAWINGS
DETAILS OF RCC BOX CTL/NH-216/TG/STR/BOX-REIN-005
MISCELLANEOUS DETAILS CTL/NH-216/TG/STR/BOX-MISC-001
200

2
125
CL OF PROPOSED ROAD
3

750
MONOLITHIC FLY WING

2000
COMPACTED EARTH 450 425

RETURN WALL
300mm THK. FLAT STONE EMBEDDED PROPOSED SEQUENCE OF CONSTRUCTION:-
2000 1500 7000 1500 2000
IN 150mm thk. M15 CONCRETE

800
1. EARTH WORK EXCAVATION
150mm THK. M15 PCC
2. CONFIRMATION OF FOUNDING LEVEL AS MENTIONED IN GFC DRAWING
CURTAIN WALL PCC M20 3. LAYING OF PCC LEVELLING COURSE
14000(SQ) 100 1300 100 4. CONSTRUCTION OF BOTTOM SLAB WITH A PORTION OF WEB
FLEXIBLE APRON 100mm THK. M15 PCC

TO TIMMAPURAM
16693(SK) 5. CONSTRUCTION OF WEB
TYPICAL CROSS SECTION OF 6. CONSTRUCTION OF TOP SLAB WITH A PORTION OF TOP WEB
7. BACK FILLING BEHIND THE SIDE WALL
CURTAIN WALL(U/S SIDE)
8. LAYING OF WEARING COAT

11350
(SCALE-1:30) 9. PLACING OF SIDL
FLOOR APRON
(FLEXIBLE APRON) 1

4000
D/S
MINIMUM OF 3000 OR
AS PER ROW AVAILABLE
CL OF CULVERT
PCC CURTAIN WALL

MONOLITHIC FLY WING


3354
MONOLITHIC FLY WING

1.5:1
RETURN WALL
RETURN WALL

EARTH CUSHION

400
BOX TOP LVL
2:1

PCC TOE WALL


FLEXIBLE APRON 150 X 150
TO GURJANAPALLI

HAUNCH (TYP.)
11350

2000
FLOOR APRON (FLEXIBLE APRON)
1 400 4000(SQ) 400
U/S MINIMUM OF 6000 OR 3354(SK)
AS PER ROW AVAILABLE 600 THK.
FILTER MEDIA

PCC CURTAIN WALL


MONOLITHIC FLY WING

NOTES:
1.5:1

RETURN WALL

01. ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METERS UNLESS MENTIONED OTHERWISE .

450
PCC M15 02. DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
VIEW 3 -3 03. GRADE OF CONCRETE:
(SCALE-1:40)
2:1 (i) RCC BOX...................................M30
(ii) PCC PARAPET.........................M30
3 (iii) RCC RETURN WALL...............M30
PCC TOE WALL TOPSLAB (iv) PCC LEVELING COURSE.......M15

LHS 3450 LHS 3450 PLAN EQ


RHS 3450 CL OF CULVERT RHS 3450 (SCALE-1:50) 2 EQ EQ 04. GRADE OF UNTENSIONED STEEL SHALL BE Fe 500D, CONFORMING TO IS: 1786
GUARD STONE 05. 600mm FILTER MEDIA SHALL BE PROVIDED BEHIND RCC BOX AND RETURN WALL.

100
HAUNCH 150 X 150(TYP.) 06. THE BACK FILL MATERIAL BEHIND RCC BOX / RETAINING WALL SHALL HAVE
TO TIMMAPURAM FOLLOWING PROPERTIES =2.0 T/Cum.
TO GURJANAPALLI CONSTRUCTION JOINT 07. SEISMIC ZONE - II

DETAILS AT JUNCTION OF
EARTH CUSHION TOP SLAB AND SIDE WALL 9. FLOW DIRECTION SHOWN IN THE PLAN IS INDICATIVE ONLY, BED PROTECTION FOR
(SCALE-1:20) UPSTREAM AND DOWN STREAM SHALL BE BASED ON THE FLOW DIRECTION THE SITE.
300

150 BOX TOP LVL 10. FLEXIBLE APRON SHALL BE PROVIDED BASED ON SITE CONDITION AND
SHALL BE DECIDED BY ENGINEER-IN-CHARGE WHEREVER ROCK IS
200 AVAILABLE AT TOP LEVEL FLEXIBLE APRON SHALL BE DISPENSED.
300mm THK. FLAT STONE
APRON EMBEDDED IN 11. BACK FILLING SHALL BE DONE SIMULTANEOUSLY ON BOTH SIDE OF BOX.
1.5 INVERT LVL
1 150 X 150 150 THK. CONCRETE (M15) 12. DRAWING SHALL BE READ IN CONJUCTION WITH RELEVENT APPROVED HIGHWAY DRAWING
1.5 FOR FRL,INVERT LEVEL,GL, CROSS SLOPE,LONGITUDINAL GRADIENT,
HAUNCH (TYP.) 1 ROAD WAY DETAILS ETC.

500
WEEP HOLES AT CONSTRUCTION JOINT EQ
PCC M20 EQ EQ 13. PITCHING / REVETMENT ON SLOPES TO BE PROVIDED AS PER MORTH SPECIFICATION.
1500c/c STAGGERED

650
14. IF BC/CLAYEY SOIL ENCOUNTERED AS FOUNDING SOIL, THEN 900mm. DEPTH OF SOIL

100
HAUNCH 150 X 150(TYP.) BELOW FOUNDATION TO BE REMOVED & FILLED BY METAL / BOULDRES WITH SAND AS

100
PER SP-13.
1200

15. STRUCTURE HAS BEEN DESIGNED FOR


100 150

i) ONE LANE, TWO LANE AND THREE LANES OF CLASS A


INVERT LVL 150mm THK. PCC M15 150mm THK. PCC M15
ii) ONE LANE OF CLASS 70R + ONE LANE OF CLASS A
1 LEVELING COURSE iii) ONE LANE OF 40R BOGIE + ONE LAYER OF CLASS 1
300 COMPACTED EARTH COMPACTED EARTH
** SHEAR KEY IS NOT SHOWN 1 500 16. CONSTRUCTION JOINTS:-
DETAILS AT JUNCTION OF THE LOCATION AND PROVISION OF CONSTRUCTION JOINTS SHALL BE AS PER THE
FOR CLARITY 100 300 DETAIL-A PCC M15
VIEW 2 -2 BASE SLAB AND SIDE WALL DRAWING AND THE SAME SHALL BE APPROVED BY THE ENGINEER-IN-CHARGE.
PCC M15 (SCALE-1:20) DETAILS OF TOE WALL
(SCALE-1:40) (SCALE-1:20)
SCALE 1:10 SCHEDULE CHAINAGE AS PER CA CH:37+709
Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
GENERAL ARRANGEMENT DETAILS OF
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout, BOX CULVERT AT CH : 37+650
D:\KAKINADU\CULVERTS\37+650-BOX

(Ministry of Shipping,Road Transport & Highways)


Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:34pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED. M/s . SMART SERVICE PVT LTD.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers, PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056
ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- 22
1 + 6 6 + 1

0.3 A 6 1 6 0.3 A
6 4 3a 3 6 6 2 2a 1 6
15 14 14 15 15 14 14 15

11 11

2 2 + 2a 7 1 + 6

0.3 B
0.3 B
0.15 A 0.15 A
6 + 1

1 1

1 1 1 1 6
5 5

9
9 9 9
8 0.3 A 0.3 A 4
0.3 A 4

6 + 4 4 + 6

0.15 A 0.15 A

0.3 B

0.3 B
9 9
9 8 10 10
0.3 A 3 3 + 3a 8

8 7
11 11

0.3 A 0.3 A
4 + 6 6 4 6
6 + 4
SCHEDULE OF REINFORCENMENT:-
SECTIONAL ELEVATION 1-1

NOTATION
8 7 PATTERN OF BAR DIA BAR REINFORCEMENT DETAILS

BAR
BENDING in mm. SPACING SCALE 1:20
in mm.
(NOT TO SCALE)

1 16 200
4 + 6 1 + 6 6 + 1 NOTES:
6 + 4 2 16 200 1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
5 OTHERWISE STATED. THE DRAWING SHALL NOT BE SCALED.
5 2a 12 200 2. THE FOLLOWING GRADE OF CONCRETE SHALL BE USED FOR
5 5
a) LEVELLING COURSE - M15
3 20 200 b) RCC BOX - M30
3
10 16 200 3. REINFORCEMENT BARS SHALL BE HIGH YIELD STRENGTH DEFORMED BARS Fe500
3a
4. CLEAR COVER TO ANY REINFORCEMENT BAR IN RAFT SLAB BOTTOM AND EARTH FACE OF
16 200 SIDE WALLS SHALL BE 75mm & 50mm FOR REMAINING LOCATIONS
4 5. ANCHORAGE LENGTH SHALL BE AS PER CLAUSE 15.2.3.3 OF IRC112 - 2011

15 14 14 15 15 14 14 15 6. BAR LAPS SHALL BE AS PER CLAUSE 15.2.5.1 OF IRC112 - 2011


BOTTOM SLAB REINFORCEMENT PLAN TOP SLAB REINFORCEMENT PLAN 5 10 200
SCALE 1:30 SCALE 1:30
3 TOP REINFOREMENT TOP REINFOREMENT
6 16 200
BOTTOM REINFOREMENT BOTTOM REINFOREMENT

7 12 200
18

8 12 200
2 16
EQ

18
9 12 200
300

16
EQ

15
EQ

10 10 200
EQ

14 EARTH FACE
EQ

EQ

14 14
varies

11 12 4- no's NOTES:
EQ

15
EQ

RCC BOX 1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS


EQ

12 10 200 OTHERWISE STATED. THE DRAWING SHALL NOT BE SCALED.


17
2. THE FOLLOWING GRADE OF CONCRETE SHALL BE USED FOR
EQ

DETAILS OF KEY SECTION 2-2


17
13 10 200
a) LEVELLING COURSE - M15
SCALE 1:15
12 SCALE : 1:10 b) RCC BOX - M30
(REFER "DETAIL-A" IN GAD) 14 16 180
13 300 2 180 3. REINFORCEMENT BARS SHALL BE HIGH YIELD STRENGTH DEFORMED BARS Fe500
15 16 2L STIRRUPS
4. CLEAR COVER TO ANY REINFORCEMENT BAR IN RAFT SLAB BOTTOM AND EARTH FACE OF
ELEVATION OF RETURN WALL 16 20 3 NOS SIDE WALLS SHALL BE 75mm & 50mm FOR REMAINING LOCATIONS
SCALE 1:30
5. ANCHORAGE LENGTH SHALL BE AS PER CLAUSE 15.2.3.3 OF IRC112 - 2011
17 20 3 NOS 6. BAR LAPS SHALL BE AS PER CLAUSE 15.2.5.1 OF IRC112 - 2011
150
D:\KAKINADU\CULVERTS\BOX REINFORCEMENT-REIN-003A

18 12 2L STIRRUPS
Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF REINFORCEMENT DETAILS OF BOX CULVERT FOR 5 X 2m BOX CULVERT
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout,
(Ministry of Shipping,Road Transport & Highways)
Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:35pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers,
M/s . SMART SERVICE PVT LTD. PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056 ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- REIN-003a
6 3 3a 4 6 6 2 2a 1 6 NOTES:
15 14 14 15 15 14 14 15 1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE STATED. THE DRAWING SHALL NOT BE SCALED.
18 2. THE FOLLOWING GRADE OF CONCRETE SHALL BE USED FOR

16
a) LEVELLING COURSE - M15
b) RCC BOX - M30

EARTH FACE
3. REINFORCEMENT BARS SHALL BE HIGH YIELD STRENGTH DEFORMED BARS Fe500
14 14 4. CLEAR COVER TO ANY REINFORCEMENT BAR IN RAFT SLAB BOTTOM AND EARTH FACE OF
varies

15 SIDE WALLS SHALL BE 75mm & 50mm FOR REMAINING LOCATIONS


5. ANCHORAGE LENGTH SHALL BE AS PER CLAUSE 15.2.3.3 OF IRC112 - 2011
6. BAR LAPS SHALL BE AS PER CLAUSE 15.2.5.1 OF IRC112 - 2011

17
SECTION 2-2
SCALE 1:15

ADDITIONAL MESH REINFIRCEMENT ADDITIONAL MESH REINFIRCEMENT


1 1 1 1 T16@150 c/c FOR BOTH TOP AND BOTTOM OF BOTTOM SLAB T16@150 c/c FOR BOTH TOP AND BOTTOM OF TOP SLAB

9 9
9 9
0.3 A 0.3 A 0.3 A 0.3 A

9 9
9 9

8 7

8 7

BOTTOM SLAB TOP SLAB


(N.T.S) (N.T.S)
6 + 4 6 + 1
4 + 6 1 + 6
1 + 6 6 + 1
6 1 6
5 5 0.3 A 0.3 A
5 5

11 11
3
10 10
2 2 + 2a 7 1
+

0.3 B
0.3 B
6 0.15 A 0.15 A 6
15 14 14 15 15 14 14 15 +
BOTTOM SLAB REINFORCEMENT PLAN TOP REINFOREMENT 1
TOP SLAB REINFORCEMENT PLAN
SCALE 1:30 BOTTOM REINFOREMENT
SCALE 1:30
3 TOP REINFOREMENT
1 1
BOTTOM REINFOREMENT SCHEDULE OF REINFORCENMENT:- SCHEDULE OF REINFORCENMENT:-
NOTATION

NOTATION
PATTERN OF BAR DIA BAR PATTERN OF BAR DIA BAR
BAR

BAR
BENDING in mm. SPACING BENDING in mm. SPACING 6
in mm. in mm. 5 5
(NOT TO SCALE) (NOT TO SCALE)

16 200 8 12 200 6
1
18

9
16 200 9 12 200
2 16 2
4
4
300

2a 12 200
10 10 200
EQ

15
20 200 4
3 +
EQ

14
EQ

11 12 4- no's 0.15 A 0.15 A 6

0.3 B

0.3 B
16 200
EQ

3a 10
6 10
12 10 200
EQ

EQ

+ 3 3 + 3a 8
16 200
RCC BOX 4 4
13 10 200
EQ
EQ

17
EQ

5 10 200 14 16 180 11 11
EQ

180
DETAILS OF KEY 15 16 2L STIRRUPS
12 SCALE : 1:10 0.3 A 0.3 A
2 6 16 200
(REFER "DETAIL-A" IN GAD) 300 16 20 3 NOS 6 4 6
4 + 6
13 6 + 4
ELEVATION OF RETURN WALL 17 20 3 NOS
SCALE 1:30 7 12 200 SECTIONAL ELEVATION 1-1
150
D:\KAKINADU\CULVERTS\BOX REINFORCEMENT-REIN-003B

18 12 2L STIRRUPS REINFORCEMENT DETAILS (SCALE 1:20) SCHEDULE CHAINAGE AS PER CA CH:36+491


Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF REINFORCEMENT DETAILS OF BOX CULVERT FOR 5(sk)/3.94 (sq) X 2M BOX CULVERT
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout,
(Ministry of Shipping,Road Transport & Highways)
Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:35pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers,
M/s . SMART SERVICE PVT LTD. PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056 ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- REIN-003b
1 + 6 6 + 1

0.3 A 6 1 6 0.3 A
6 4 3a 3 6 6 2 2a 1 6
15 14 14 15 15 14 14 15

11 11

2 2 + 2a 7 1 + 6

0.3 B
0.3 B
0.15 A 0.15 A
6 + 1

1 1

1 1 1 1
6
5 5

9
9 9 9
8 0.3 A 0.3 A
0.3 A 4
4

6 + 4 4 + 6

9 9 0.15 A 0.15 A

0.3 B

0.3 B
9 8
10 10
0.3 A
3 3 + 3a 8

8 7
11 11

0.3 A 0.3 A
4 + 6 6 4 6
SCHEDULE OF REINFORCENMENT:- 6 + 4
SECTIONAL ELEVATION 1-1

NOTATION
8 7 PATTERN OF BAR DIA BAR

BAR
BENDING in mm. SPACING REINFORCEMENT DETAILS
in mm. SCALE 1:20
(NOT TO SCALE)

1 16 130
4 + 6 1 + 6 6 + 1
6 + 4 2 16 130
5
5 2a 10 130
5 5
3 16 130
3
10 3a 10 130

16 130
4

15 14 14 15 15 14 14 15
BOTTOM SLAB REINFORCEMENT PLAN TOP SLAB REINFORCEMENT PLAN 5 12 130 NOTES:
SCALE 1:30 SCALE 1:30 1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
3 TOP REINFOREMENT TOP REINFOREMENT
OTHERWISE STATED. THE DRAWING SHALL NOT BE SCALED.
2. THE FOLLOWING GRADE OF CONCRETE SHALL BE USED FOR
6 16 130
BOTTOM REINFOREMENT BOTTOM REINFOREMENT a) LEVELLING COURSE - M15
b) RCC BOX - M30
7 12 180
3. REINFORCEMENT BARS SHALL BE HIGH YIELD STRENGTH DEFORMED BARS Fe500
8 12 180
18
4. CLEAR COVER TO ANY REINFORCEMENT BAR IN RAFT SLAB BOTTOM AND EARTH FACE OF
SIDE WALLS SHALL BE 75mm & 50mm FOR REMAINING LOCATIONS
2 16 9 12 180
5. ANCHORAGE LENGTH SHALL BE AS PER CLAUSE 15.2.3.3 OF IRC112 - 2011
18
6. BAR LAPS SHALL BE AS PER CLAUSE 15.2.5.1 OF IRC112 - 2011
300

16 10 10 260
EQ

15

14 EARTH FACE
EQ
EQ

11 12 4- no's
EQ

14 14
varies

15
12 10 260
EQ

EQ

RCC BOX
EQ

13 10 200
17
EQ

EQ

17
SECTION 2-2 14 16 180
SCALE 1:15
EQ

DETAILS OF KEY 180


15 16 2L STIRRUPS
12 SCALE : 1:10 2
300 20 3 NOS
(REFER "DETAIL-A" IN GAD) 16
13 ELEVATION OF RETURN WALL 17 20 3 NOS
SCALE 1:30
150
12
D:\KAKINADU\CULVERTS\BOX REINFORCEMENT-REIN-004

18 2L STIRRUPS
Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF REINFORCEMENT DETAILS OF BOX CULVERT FOR 3 X 2M BOX CULVERT
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout,
(Ministry of Shipping,Road Transport & Highways)
Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:35pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers,
M/s . SMART SERVICE PVT LTD. PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056 ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- REIN-004
6 3 3a 4 6 6 2 2a 1 6 NOTES:
15 14 14 15 15 14 14 15 1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE STATED. THE DRAWING SHALL NOT BE SCALED.
18 2. THE FOLLOWING GRADE OF CONCRETE SHALL BE USED FOR

16
a) LEVELLING COURSE - M15
b) RCC BOX - M30

EARTH FACE
3. REINFORCEMENT BARS SHALL BE HIGH YIELD STRENGTH DEFORMED BARS Fe500
14 14 4. CLEAR COVER TO ANY REINFORCEMENT BAR IN RAFT SLAB BOTTOM AND EARTH FACE OF
varies

15 SIDE WALLS SHALL BE 75mm & 50mm FOR REMAINING LOCATIONS


5. ANCHORAGE LENGTH SHALL BE AS PER CLAUSE 15.2.3.3 OF IRC112 - 2011
6. BAR LAPS SHALL BE AS PER CLAUSE 15.2.5.1 OF IRC112 - 2011

17
SECTION 2-2
SCALE 1:15

ADDITIONAL MESH REINFIRCEMENT ADDITIONAL MESH REINFIRCEMENT


1 1 1 1 T16@150 c/c FOR BOTH TOP AND BOTTOM OF BOTTOM SLAB T16@150 c/c FOR BOTH TOP AND BOTTOM OF TOP SLAB

9 9
9 9
0.3 A 0.3 A 0.3 A 0.3 A

9 9
9 9

8 7

8 7

BOTTOM SLAB TOP SLAB


(N.T.S) (N.T.S)
6 + 4 6 + 1
4 + 6 1 + 6
1 + 6 6 + 1
6 1 6
5 5 0.3 A 0.3 A
5 5

11 11
3
10 10
2 2 + 2a 7 1
+

0.3 B
0.3 B
6 0.15 A 0.15 A 6
15 14 14 15 15 14 14 15 +
BOTTOM SLAB REINFORCEMENT PLAN TOP REINFOREMENT 1
TOP SLAB REINFORCEMENT PLAN
SCALE 1:30 BOTTOM REINFOREMENT
SCALE 1:30
3 TOP REINFOREMENT
1 1
BOTTOM REINFOREMENT SCHEDULE OF REINFORCENMENT:- SCHEDULE OF REINFORCENMENT:-
NOTATION

NOTATION
PATTERN OF BAR DIA BAR PATTERN OF BAR DIA BAR
BAR

BAR
BENDING in mm. SPACING BENDING in mm. SPACING 6
in mm. in mm. 5 5
(NOT TO SCALE) (NOT TO SCALE)

16 130 8 12 130 6
1
18

9
16 130 9 12 130
2 16 2
4
4
300

2a 12 130
10 10 260
EQ

15
16 130 4
3 +
EQ

14
EQ

11 12 4- no's 0.15 A 0.15 A 6

0.3 B

0.3 B
16 130
EQ

3a 10
6 10
12 10 260
EQ

EQ

+ 3 3 + 3a 8
16 130
RCC BOX 4 10 200 4
13
EQ
EQ

17
EQ

5 12 130 14 16 180 11 11
EQ

180
DETAILS OF KEY 15 16 2L STIRRUPS
12 SCALE : 1:10 0.3 A 0.3 A
2 6 16 130
(REFER "DETAIL-A" IN GAD) 300 16 20 3 NOS 6 4 6
4 + 6
13 6 + 4
ELEVATION OF RETURN WALL 17 20 3 NOS
SCALE 1:30 7 12 130 SECTIONAL ELEVATION 1-1
150
18 12 SCHEDULE CHAINAGE AS PER CA CH:33+747
D:\KAKINADU\CULVERTS\BOX REINFORCEMENT-REIN-005

2L STIRRUPS REINFORCEMENT DETAILS (SCALE 1:20)


Client: PROJECT: TITLE:
Authority Engineer: Proof Checking Consultant:
MINISTRY OF ROAD WADIA TECHNO ENGINEERING SERVICES LTD., M/s. Professional Civil Infra Private Limited REHABILITATION AND UPGRADATION OF REINFORCEMENT DETAILS OF BOX CULVERT FOR 4(sk)/3.354 (sq) X 2M BOX CULVERT
TRANSPORT & HIGHWAYS Raheja Points I, Wing "A" # 1838, Ground Floor, Sir. M Visweswaraya Layout,
(Ministry of Shipping,Road Transport & Highways)
Pt. Jawaharlal Nehru Road, Vakola, TIMMAPURA - GURJANAPALLI SECTION SRI AUTHORIZED SIGNATURE SCALE As Shown
Santacruz (E), Mumabi-400 055, India Ph: +91 90350 01642, Mob: +91 88867 22992 DRN.
FROM KM 26+150 TO KM 41+161ON NH 214 (CONCESSIONAIRE)
Jul 04, 2017 - 12:35pm

EPC Contractor: Design Consultant: Safety Consultant: (NEW NH -216) TO TWO LANE WITH DSND. BPK DATE February 2017
MCL-KSIPL(JV) CTL GLOBAL SERVICES PVT. LIMITED.
706, Ship Building, 7th Floor, 101, IST Floor, Krishna Chambers,
M/s . SMART SERVICE PVT LTD. PAVED SHOULDER IN THE STATE OF DATE REV. CODE PARTICULARS DRAWN CHKD. APPD.
CHKD. LPR Rev. R0
Near Municipal Market, C.G.Road, Navrangpura, # 1838, Groung floor, Sir M Visvesvaraya layout REVISIONS
JV

Ahmedabad-380009, Gujarat, India


HAL, Airport Road, Bangalore-560017.
Nagadevanahalli, Bangalore - 560056 ANDHRA PRADESH UNDER NHDP-IV.
Ph: +91 080 23433992 / 93, Fax: +91 080 23433994 STATUS CODE : 1. PRELIMINARY COPY. 2. FOR REVIEWS. 3. MATERIAL PROCUREMENT.
THROUGH EPC. 4. FOR APPROVAL. 5. APPROVED FOR CONSTRUCTION.
DRG.NO.CTL/NH-216/TG/STR/BOX- REIN-005

You might also like