You are on page 1of 16

DEUTERIUM LAMPS

(D2 LAMPS)
Hamamatsu deuterium lamps

D2 key features and the reasons


Long lifetime
1 UV-transmitting glass

LAMPS
FOR HIGH PERFORMANCE
£Problems with prior lamps using quartz glass
Premature deterioration in transmittance
cause by UV light
£We solved these problems
by using UV-transmitting
glass superior to quartz
glass!!
Quality variations due to production
DEVICES process and material inclusions
High resistance to UV light
Troublesome ozone generation

Life characteristics High quality


Hamamatsu deuterium lamps (D2 lamps) 120
TLS B0021EA
with less variations
deliver a long lifetime, excellent stability, and 110
100

RELATIVE IRRADIANCE (%)


high output to the highest levels to allow 90
No ozone generation
users to obtain the maximum performance 80
70
characteristics from their equipment. 60
50
40
30 SYNTHETIC SILICA
SYNTHETIC SILICA ±3 σ
20 UV GLASS
10 UV GLASS ±3 σ

1 0
0 10 100
TIME (h)
1000 10000

High stability
Light output stability Maintains high stability until product lifetime end

3 2
Stability at initial operation Stability after 2000 hours of operation
20 20
15 15
10 10
ABS (10-5 A.U.)

ABS (10-5 A.U.)


5 5
0 0
-5 -5
-10 -10
-15 -15
-20 -20
0 100 200 300 400 500 600 700 800 0 100 200 300 400 500 600 700 800
TIME (s) TIME (s)
TLSOB0095EA TLSOB0096EA

2 Ceramic electrode
£Problems with prior lamps using £We solved these problems by
(Metal electrode) using ceramic electrodes with
excellent temperature
Low stability due to being susceptible to characteristics!!
ambient conditions
Excellent temperature
Large variation in light output because characteristics
electrode spacing is not uniform ensure high stability
Uniform electrode spacing
minimizes variations
in characteristics

3 Cathode (Super quiet type)


4 £Problems with conventional directly-heated type £We solved these problems of
the directly-heated type by
Concentrated radiated heat damage using a super quiet cathode!!
applies a large load to the cathode
Electron emission
Vibration and operating time directly capability with minimal
affect cathode deterioration fluctuations
Construction (L2D2)
CERAMIC ELECTRODE
(REAR PIECE)
ANODE Lighting performance
APERTURE
CERAMIC 4 Capacitor
ELECTRODE
(CENTER PIECE)
£Problems with D2 lamp without auxiliary ignition £We solved these problems with
CATHODE
the conventional lighting
Fails to light up due to electrode deterioration method by using auxiliary
during long-term operation lighting method!!
Fails to light up due to decrease of internal Secured lighting even
gas during long-term operation if the lamp is hot or
BULB
at the end of lifetime
Fails to light up when the lamp is hot and
LIGHT OUTPUT TLSOC0030EB in case of re-igniting right after turning off
1
Deuterium lamps are light source lamps that utilize an arc discharge in deuterium (D2) gas.
They emit an intense spectrum in the UV region and have feature of unrivaled stability
compared to other UV light sources.

PRODUCT LINE-UP / APPLICATION LIST


33 W 30 W 5 W to 7 W 110 W

X2D2® L2D2® S2D2® H2D2®


LAMPS LAMPS LAMPS LAMPS
High brightness deuterium lamps Long lifetime deuterium lamps Compact deuterium lamps Ultra-high luminance deuterium lamps
High-end light sources that offer Best-selling light sources that deliver Compact yet high-performance Next-generation light sources that
the world’s highest luminance the high quality and high performance light sources that were impossible have achieved the highest
among the 30 W class * (twice that required by chemical analysis to create up till now with luminance in the history of
of L2D2 lamps) instruments while keeping costs low conventional deuterium lamps deuterium lamps

P3 P5 P11 P14
*As of Feb. 2016 according to our research *As of Feb. 2016 according to our research

Window material
Applications UV glass Synthetic silica MgF2
HPLC (High Performance Liquid Chromatography)
UV-VIS Spectrophotometer
CE (Capillary Electrophoresis)
Atomic Absorption Spectrophotometer
Thin Layer Chromatography
Water Quality, Air Pollution and Other Environmental Analyzer
Film Thickness Gauge
Semiconductor Testing Equipment
UV Resistance Evaluation of Materials
Photoionization Light Source
Static Electricity Removal by Vacuum UV Light

: Optimum : Usable according to application : Not generally suitable

Peripheral devices that support high performance


Total support for extracting
maximum lamp performance
After-sales
To enable lamps to exhibit their
maximum performance, it is
service
important to design an based on long years
optimum housing and of experience
power supply. We do not only
sell deuterium lamps but
also provide power supplies Custom products
and housings specifically tailored to meet
designed for deuterium user needs
lamps.
Besides selling our own
products, we provide technical
support to help users design their Advice
own lamp housings and power for improving
supplies. We are also glad to offer performance
advice on optimal electrical ratings
characteristics
and lamp shapes that meet user Design
specifications.
Power supplies
Please consult with us for support and housings
specifications that are not listed in specifically designed
our product catalog. for lamps

2
®
X2D2
LAMPS
The X2D2® lamps (high brightness & long
lifetime deuterium lamps) deliver unparalleled
brightness twice that of L2D2 lamps (see page
5) while still maintaining the high stability and
long lifetime offered by the conventional
deuterium lamps. These characteristics will
enhance sensitivity and throughput in various
photometric instruments.

Features Characteristics
●Long life: 2000 h ●Spectral distribution
TLSOB0024EF TLSOB0079EC
●High stability: 0.005 %(p-p) typ. 1 100

●High brightness: 2 times higher than L2D2 lamps


IRRADIANCE (µW·cm-2·nm-1 at 50 cm)

80

RELATIVE IRRADIANCE (%)


■Arc distribution
SYNTHETIC SILICA
(L9519, L10904)
0.1
●X2D2 lamp Aperture size: 0.5 mm 60
MgF2 (L9841)

UV GLASS
(L9518, L10804)
40

0.01

20

0.001 0
160 200 240 280 320 360 400 100 120 140 160 180 200 220 240 400

WAVELENGTH (nm) WAVELENGTH (nm)

●Directivity (Light distribution)


1UV glass 2Synthetic silica 3MgF2
2 times L9518, L10804
30°
L9519, L10904 L9841

higher than 20° 20°


30° 30°
20°
conventional type 10° 10° 10°

0° 0° 0°
●L2D2 lamp Aperture size: 0.5 mm -10° -10° -10°

-20° -20° -20°


-30° -30° -30°

30° 30° 30°


20° 20° 20°

10° 10° 10°

0° 0° 0°

-10° -10° -10°

-20° -20° -20°


-30° -30° -30°
TLSOB0111EA TLSOB0112EA TLSOB0113EA

3
Dimensional outline (Unit: mm)
L9518, L10804 L9519, L10904
50 50
-0.05 Tolerance of emitting point (center) -0.05 Tolerance of emitting point (center)
35 - 0.1 35 -0.1
A

A
With respect to axial line A: ±0.1 With respect to axial line A: ±0.1
30 ± 1 With respect to plane B: ±0.1 30 ± 1 With respect to plane B: ±0.1
ARC POINT ARC POINT
+0.15 +0.15
3 + 0.05 3 +0.05

59 MAX.

59 MAX.
ARC POINT ARC POINT

15
50

50
22 - 0.1

22 - 0.1
10

10
+0

+0
32
32
B B
2 × 3.3
5

5
2 × 3.3

14 ± 1
9 MAX.

9 MAX.
AUXILIARY AUXILIARY
IGNITION 22±0.05 22±0.05 IGNITION
DEVICE DEVICE 22±0.05 22±0.05
160 ± 10

160 ± 10
LIGHT OUTPUT
LIGHT OUTPUT
CONNECTOR (MOLEX) CONNECTOR (MOLEX)
CONNECTION HOUSING: 39-01-2040 CONNECTION
HOUSING: 39-01-2040
(70)

(70)
#1: AUXILIARY ELECTRODE CONTACT: 39-00-0428 #1: AUXILIARY ELECTRODE
CONTACT: 39-00-0428
#2: ANODE #2: ANODE
#3: FILAMENT #3: FILAMENT
#4: FILAMENT (GND) TLSOA0105EE #4: FILAMENT (GND) TLSOA0106EE

L9841 50
Tolerance of emitting point (center)
-0.05
35 -0.1 With respect to axial line A: ±0.1
Example of optical system layout for visible light
A

With respect to plane B: ±0.1


30 ± 1
+0.15
3 +0.05
(X2D2 lamp)
ARC POINT
ARC POINT The see-through structure allows easy use in combination
59 MAX.

with a visible light source.


15

22 - 0.1
+0
50
10
32

B 2 × 3.3 TOP VIEW


5

25 ± 1

ANGLE OF INCIDENCE
19°
9 MAX.

AUXILIARY
IGNITION LIGHT
DEVICE 22±0.05 22±0.05
OUTPUT
160 ± 10

HALOGEN
LENS
LIGHT OUTPUT LAMP
(VISIBLE LIGHT)
CONNECTOR (MOLEX)
HOUSING: 39-01-2040 CONNECTION L10804, L10904
(70)

CONTACT: 39-00-0428 #1: AUXILIARY ELECTRODE


#2: ANODE TLSOC0053ED
#3: FILAMENT
#4: FILAMENT (GND) TLSOA0107EE

Specifications
Type No. L9518 L10804 L9519 L10904 L9841 Unit
Type Standard See-through Standard See-through Standard —
Window material UVglass Synthetic silica MgF2 —
Spectral distribution 185 to 400 160 to 400 115 to 400 E nm
Aperture diameter 0.5 mm
Output stability Drift (Max.) ±0.3 %/h
at 230 nm Fluctuation (p-p) Typ. 0.005 %
Guaranteed life at 230 nm A 2000 h
Discharge starting voltage (Max.) B 400 V dc
Anode current 300 ± 30 mA dc
Tube voltage (Typ.) 90 85 V dc
Voltage 2.5 ± 0.25 V dc
Warm-up
Current (Typ.) 4 A dc
Filament ratings
Voltage 1.7 ± 0.2 V dc
Operating
Current (Typ.) 3.3 A dc
Filament warm-up time (Min.) 20 s
Power supply C C9559, M9521 —
Bulb wall temperature D 245 to 290 °C
ALamp life end is defined as the point when light output at 230 nm falls to 50 % of its initial value or when output fluctuations exceed 0.05 % (p-p).
BA trigger voltage must be applied to the anode and auxiliary electrode. CThe power supply for the L2D2 cannot be used to operate X2D2 lamps.
DRecommended temperature for operating a lamp in the lamp housing. Consult us on how to measure the temperature.
EDoes not support vacuum evacuation and so should be used in nitrogen atmosphere.
* Custom lamps not listed above will be available on request. Please feel free to contact us.

4
®
L2D2
LAMPS
The L2D2® lamps are UV light sources
with a long service lifetime and high
stability. These L2D2 lamps have charac-
teristics essential for light sources used
in chemical analysis instruments and
provide high measurement accuracy.

Example of custom-designed lamp


Cathode
Aperture diameter type Cathode ratings
( 0.5, 1.0) Preheating Operating
1 2.5 V 1.0 V
2 2.5 V 1.7 V
Features Light-emitting point
3 3.0 V 0V–1V
4 10 V 2.5 V – 6 V
5 10 V 7V
●Long life: 4000 h (L6565) 6 12 V – 15 V 0V

●High stability: 0.005 %(p-p) typ. Flange


shape
●Small intensity variations Capacitor position Lead length
●Low cost
●Error-free lighting Connector

Please consult us about custom


designed lamp.

Specifications
A B Required
Output stability at 230 nm
Dimen- Guaranteed discharge Anode Tube
Window Spectral Aperture Fluctuation life starting
Type No. Type sional Drift (p-p) current voltage
C
outline
material distribution diameter at 230 nm voltage
Max. Typ. Max. Typ.
(nm) (mm) (%/ h) (%) (h) (V dc) (mA dc) (V dc)
L6565 1.0 4000 350
q
L6301
L6301-50 i
L6303 q
UV glass 185 to 400
L12313 e
L12313-50 u
0.5 ±0.3 0.005 2000 400
L6307 Standard
w
L6309
300 ± 30 80
L7296 r Synthetic
160 to 400
L7296-50 y silica
L12307 w UV glass 185 to 400
L7293 t
MgF2 115 to 400 1.0 — — 2000D 350
L7293-50 o
L6999 q
UV glass 185 to 400
L6999-50 i
See-through 0.5 ±0.3 0.005 2000 400
L9030 r Synthetic
160 to 400
L9030-50 y silica
ASee pages 7 and 8.
BLamp life end is defined as the point when light output at 230 nm falls to 50 % of its initial value or when output fluctuations exceed 0.05 % (p-p).
CA pulse voltage higher than this value must be supplied to start reliable lamp discharge.
DOperating life may vary depending on operating environmental conditions (vacuum atmosphere).

5
Characteristics
●Spectral distribution
Deuterium lamps emit high intensity light in the UV range at wavelengths shorter than 400 nm. Light intensity on the short wavelength side is deter-
mined by the window material used.
■UV glass, Synthetic silica ■MgF2
TLSOB0024EF TLSOB0079EC
1.0 100
IRRADIANCE (µW·cm-2·nm-1 at 50 cm)

SYNTHETIC SILICA

RELATIVE IRRADIANCE (%)


(PROJECTING TYPE, 1 mm THICK) 80
MgF2

0.1
60

UV GLASS
40
0.01

20

0.001 0
160 200 240 280 320 360 400 100 120 140 160 180 200 220 240 400

WAVELENGTH (nm) WAVELENGTH (nm)

●Arc distribution ●Directivity (Light distribution)


Arc distribution of deuterium lamps is determined by the aperture 1UV glass 2Synthetic silica 3MgF2
(light exit) size. At the same input current and voltage, lamps with a 30° 30° 30°
0.5 mm aperture provide 1.4 times higher intensity than lamps with a 20° 20° 20°
1.0 mm diameter aperture. 10° 10° 10°

0° 0° 0°

-10° -10° -10°

-20° -20° -20°


-30° -30° -30°

30° 30° 30°


20° 20° 20°

10° 10° 10°

0° 0° 0°

-10° -10° -10°


APERTURE: 0.5 mm APERTURE: 1.0 mm
-20° -20° -20°
-30° -30° -30°
TLSOB0021EC TLSOB0020EC TLSOB0077EC

Filament ratings Applicable power supply H


Warm-up Operating Filament
Bulb wall
warm-up time
Voltage E Current Voltage Current AC input type DC input time temperature Type No.
Typ. Typ. Min. (Recommended) I
(V dc, ac) (A dc, ac) (V dc) (A dc) (s)
L6565
1.0 ± 0.1 1.8 C9598-2510 M9596-2510 L6301
2.5 ± 0.25 4
L6301-50
1.7 ± 0.2 3.3 C9598-2517 M9596-2517 L6303
L12313
3 5 0 to 1 0 to 1.8 C9598-3000 M9596-3000
L12313-50
0.8 2.5 to 6.0 F 0.3 to 0.6 C9598-1035 M9596-1035 L6307
L6309
10 ± 1 20 245 to 290
1.2 7.0 ± 0.5 1 C9598-1070 M9596-1070 L7296
L7296-50
12 to 15 0.5 to 0.55 0G 0G C9598-1555 M9596-1555 L12307
L7293
L7293-50
L6999
2.5 ± 0.25 4 1.0 ± 0.1 1.8 C9598-2510 M9596-2510
L6999-50
L9030
L9030-50
EIf the cable between the lamp and power supply is too long, a large filament voltage drop occurs in the cable that might make the lamp filament voltage too low.
The filament power supply should be designed to supply the specified voltage at the lamp input terminal.
FRecommended operating voltage is 3.5 V ± 0.5 V.
GDuring lamp operation a discharge current flows into the filament so no external power supply is needed to maintain the filament temperature.
HTo extract full performance from our deuterium lamps we recommend using our dedicated power supplies.
IRecommended temperature for operating a lamp in the lamp housing. Consult us on how to measure the temperature.
* Custom lamps not listed above will be available on request. Please feel free to contact us. 6
Dimensional outline (Unit: mm)

See-through type
q L6301, L6565, L6303, L6999 w L6307, L6309 , L12307 e L12313

7 MAX.
7 MAX.
28 ± 1 30±1

7 MAX.
30 ± 1

68 ± 2
68 ± 2

60 ± 2
42 ± 2
42 ± 2
42 ± 2

ARC POINT ARC POINT ARC POINT


160 ± 10

160 ± 10
160 ± 10
CONNECTION
CONNECTION CONNECTION
L6303

20
20
FILAMENT : BLUE
20

FILAMENT : BLUE
FILAMENT : BLUE FILAMENT . GND : BLUE
FILAMENT.GND : BLACK

7
7
7

FILAMENT · GND : BLACK ANODE : RED


ANODE : RED 6
ANODE : RED 6 6

L6301, L6565, L6999


FILAMENT : BLUE
FILAMENT : BLUE
ANODE : RED TLSOA0040ED TLSOA0018EF TLSOA0039EF

See-through type See-through type


r L7296, L9030 t L7293 y L7296-50, L9030-50
7 MAX.
7 MAX.

50 ± 1 - 0.05
35.0 - 0.1
30 ± 1 50 ± 1

7 MAX.
A
14 ± 1 30 ± 1
8 7 30 ± 1 22.0 ± 0.1 22.0 ± 0.1 ARC
POINT

2 × 3.3
15
15

68 ± 2
68 ± 2

22.0 - 0.1
68 ± 2

+0

ARC
42 ± 2
42 ± 2

POINT
42

ARC B

14 ± 1
15
15

ARC POINT O-RING


5

POINT +0.15
FIXED 3 +0.05
RANGE
15 ± 0.5
160 ± 10
160 ± 10
160 ± 10

LIGHT OUTPUT
20

CONNECTION CONNECTION
7

CONNECTION
L7296 6
L7293 L7296-50
20

20

FILAMENT : BLUE FILAMENT : BLUE FILAMENT : BLUE


7

FILAMENT.GND : BLACK FILAMENT : BLUE FILAMENT·GND : BLACK Tolerance of emitting point (center)
ANODE : RED 6 6 ANODE : RED With respect to axial line A: ±0.1
ANODE : RED With respect to plane B: ±0.1

L9030 L9030-50
FILAMENT : BLUE FILAMENT : BLUE
FILAMENT : BLUE FILAMENT : BLUE
ANODE : RED ANODE : RED
TLSOA0017EG TLSOA0011EF TLSOA0075EE

7
See-through type
u L12313 -50 i L6301-50, L6999-50 o L7293-50

- 0.05
35.0 - 0.1 - 0.05

A
-0.05 35.0 - 0.1

7 MAX.
35 -0.1

A
7 MAX.

50 ± 1

7 MAX.
50 ± 1 28 ± 1
A

30 ± 1
ARC 30 ± 1 22.0 ± 0.1 22.0 ± 0.1 ARC
22 ± 0.1 22 ± 0.1 ARC
POINT POINT
POINT
50 ± 1
2 × 3.3 22.0 ± 0.1 22.0 ± 0.1 2 × 3.3
60 ± 2

68 ± 2
ARC

22.0 - 0.1
68 ± 2
37

+0
ARC
22 -0.1

POINT
+0

7
37
B POINT

42
2 × 3.3
15

B
5

O-RING

15
+0.15
3 +0.05 B

50 ± 1
15
22.0 - 0.1

8
FIXED

+0

5
RANGE +0.15
3 +0.05
ARC 15 ± 0.5
POINT
160 ± 10

160 ± 10
LIGHT OUTPUT +0.15
3 +0.05 15

160 ± 10
LIGHT OUTPUT LIGHT OUTPUT

CONNECTION CONNECTION CONNECTION


20

FILAMENT : BLUE FILAMENT : BLUE FILAMENT : BLUE


20

20
FILAMENT : BLUE FILAMENT : BLUE FILAMENT : BLUE
7

7
ANODE : RED ANODE : RED ANODE : RED
6 6 6

Tolerance of emitting point (center) Tolerance of emitting point (center) Tolerance of emitting point (center)
With respect to axial line A: ±0.1 With respect to axial line A: ±0.1 With respect to axial line A: ±0.1
With respect to plane B: ±0.1 With respect to plane B: ±0.1
With respect to plane B: ±0.1

TLSOA0050EA TLSOA0051ED TLSOA0088EC

Mounting example on the vacuum system See-through type


(L7293, L7293-50)
The see-through type electrode structure enables straight-line arrange-
1 ment of the halogen lamp, deuterium lamp, optical system and optical
path. This simplifies optical design of UV-VIS spectrophotometer etc.,
2 and eliminates loss of light amount caused by the half mirror.

4
An example for optics of See-through type
TOP VIEW

40°
A ARC
POINT
LIGHT
B SCREW PORTION OUTPUT
HALOGEN
C LENS LAMP
1VACUUM FLANGE
2TIGHTENING SCREW SEE-THROUGH
3O-RING JIS B2401 L2D2 LAMP
CALL No. V15 TLSOC0011EF

4SPACER
AMgF2 WINDOW
BGRADED SEAL
CO-RING FIXED RANGE
▼Type No.
TLSO 0053EA L6999, L6999-50, L9030, L9030-50

8
X2D2® L2D2® Power supply for X2D2® lamps / Lamp housing
LAMPS LAMPS

POWER SUPPLY
FOR D2 LAMPS
LAMP HOUSE
Applications using deuterium lamps require very high stability ▲Power supply Left: C9559, Right: M9521 ▲Lamp housing Left: E9522-50, Right: E9558-50
of light output, so using a Hamamatsu dedicated power supply
and lamp house is recommended to operate these lamps. Power supply for L2D2® lamps / Lamp housing
When users are designing their own power supply and lamp
housing, we provide technical support and follow-up to ensure
an optimal optical design so please consult us when needed.

E9522-50: for L9518 E9558-50: for L9519


E9522: for L6301-50 E9558: for L7296-50
* We welcome requests for custom products for see-through
types (L10804, L6999-50, L6999-50 and L9030-50). ▲Power supply Left: C9598, Right: M9596 ▲Lamp housing Left: E9522, Right: E9558

Dimensional outline (Unit: mm)


●C9559 ●E9522-50 * P.C.D. (Pitch Circle Diameter)

+0.1
2.8 - 0 WEDGE PRESSURE PIN

60
19.2
ARC POINT
3 × M4 DEPTH 5
LAMP FLANGE MOUNTING SURFACE
TOP VIEW (P.C.D.* 40)

5.8
79
3-1 32 22 2 × M3 DEPTH 5
20
C9559 °

22 ± 0.05 22 ± 0.05
3-120°

35.2
140

50
R2
35 18 3 × M3 (P.C.D.* 24) 34 ARC POINT
ARC POINT

5
110 280 +0.2
32.2 -0 OPTICAL SYSTEM MOUNTING SURFACE
FRONT VIEW SIDE VIEW REAR VIEW
TLSOA0114EA
●Supplied lamp output cable
●E9558-50 +0.1
3000 ± 50 2.8 - 0 WEDGE PRESSURE PIN

TLSOA0112EA 60

●M9521
OPTICAL SYSTEM
MOUNTING SURFACE 32

4.2
LAMP FLANGE MOUNTING SURFACE
3 × M4 DEPTH 5 79
(P.C.D.* 40) 29 ± 1 22 2 × M3 DEPTH 5
100
110

ARC POINT 20°


R2

3-1

22 ± 0.05 22 ± 0.05

35.2
50

160 35 MAX. 5 MAX.


170 °
20
FRONT VIEW SIDE VIEW 3-1 3 × M3 (P.C.D.* 24) 32 5 34 ARC POINT
TLSOA0113EA TLSOA0115EA

Power supply for X2D2 lamp specifications


Parameter C9559 M9521 Unit
AC 100 V to AC 240 V
Input voltage (100 V/200 V Auto switching) DC 24 V ± 2.4 V —
Input Single phase 50 Hz / 60 Hz
Input current (Max.) 1.4 3 A
Output With load (Typ.) 85 / 90 V dc
voltage (DC) Without load (Min.) 200 V dc
Output current (DC) 300 ± 30 mA dc
Current fluctuation (p-p) (Typ.) 0.005 %
Current drift at 25 °C (Typ.) ±0.02 %/h
Output Voltage 2.5 ± 0.2 V dc
Warm-up
Filament Current (Typ.) 4 A dc
ratings Voltage 1.7 ± 0.2 V dc
Operation
Current (Typ.) 3.3 A dc
Filament warm-up time Approx. 20 s
Trigger Anode 600 V peak
voltage Auxiliary electrode 600 V peak
Cooling method — Forced air cooling (0.3 m3/min) —
Operation ambient temperature 0 to +40 °C
Storage temperature -10 to +60 °C
Operating and storage humidity Below 80 (No condensation) %
External control (Lamp ON/OFF, Lamp irradiation signal) Yes Yes —
Conformance CE Yes Yes —
9 standards UL (File No. E249677) — Yes —
Dimensional outline (Unit: mm)
The power supply for the L2D2 cannot be used to operate X2D2 lamps. * P.C.D. (Pitch Circle Diameter)

●C9598 ●E9522 ARC POINT

60
+0.1
2.8 - 0 WEDGE PRESSURE PIN

19.2
LAMP FLANGE
3 × M4 DEPTH 5
MOUNTING SURFACE
TOP VIEW (P.C.D.* 40)

5.8
84
3-1 37 22 ± 0.05 2 × M3 DEPTH 5
20
°

22 ± 0.05 22 ± 0.05
3-120°
90

35.2
50
117 200

R2
35 18 3 × M3 (P.C.D.* 24) 32 ARC POINT
ARC POINT

5
FRONT VIEW SIDE VIEW REAR VIEW +0.2
32.2 -0 OPTICAL SYSTEM MOUNTING SURFACE

●Supplied lamp output cable TLSOA0118EA

●E9558
1800 ± 50
+0.1

60
TLSOA0116EA 2.8 - 0 WEDGE PRESSURE PIN

LAMP FLANGE
●M9596 OPTICAL SYSTEM
MOUNTING SURFACE 32 MOUNTING SURFACE

4.2
3 × M4 DEPTH 5 84 29 ± 1
22 2 × M3 DEPTH 5
(P.C.D.* 40)

5
ARC POINT 20°

R2
86.4

3-1
100

22 ± 0.05 22 ± 0.05

35.2
50
118 30 MAX. 5 MAX.
°
102 20
3-1 3 × M3 (P.C.D.* 24) 37 5 34 ARC POINT
FRONT VIEW SIDE VIEW
TLSOA0117EA TLSOA0119EA

Power supply for L2D2 lamp specifications


Parameter C9598 M9596 Unit
AC 100 V to AC 240 V
Input voltage (100 V/200 V Auto switching) DC 24 V ± 2.4 V —
Input Single phase 50 Hz / 60 Hz
Input current (Max.) 0.9 2 A
With load (Typ.) 80 V
Output voltage (DC)
Without load (Min.) 200 V
Output current (DC) 300 ± 30 mA
Output Current Fluctuation (p-p) (Typ.) 0.005 %
Current drift at +25 °C (Typ.) ±0.02 %/h
Warm-up time Approx. 20 s
Trigger voltage Approx. 600 V peak
Cooling method — Forced air cooling (0.3 m3/min) —
Operation ambient temperature 0 to +40 °C
Storage temperature -10 to +60 °C
Operating and storage humidity Below 80 (No condensation) %
External control (Lamp ON/OFF, Lamp irradiation signal) Yes Yes —
Conformance EN (CE marking) Yes Yes —
standards UL (File No. E249677) — Yes —

Filament ratings
Warm-up Operation
Type No. Voltage Current Voltage Current Applicable lamp
(V dc) (A dc)(Typ.) (V dc) (A dc)(Typ.)
L6565, L7293, L6999, L6999-50, L7293-50
C9598/M9596-2510 2.5 ± 0.2 4 1.0 ± 0.1 1.8
L6301, L6301-50, L9030, L9030-50
C9598/M9596-2517 2.5 ± 0.2 4 1.7 ± 0.2 3.3 L6303
C9598/M9596-3000 3 ± 0.2 5 0 0 L12313
C9598/M9596-1035 10 ± 0.5 0.8 3.5 ± 0.2 0.3 L6307
C9598/M9596-1070 10 ± 0.5 1.2 7 ± 0.4 1 L7296, L6309, L7296-50
C9598/M9596-1555 13.5 ± 0.7 0.5 5.25 ± 0.25 0.3 L12307

10
®
S2D2
LAMPS
The S2D2® lamps are compact deuterium
lamps with a drastically reduced size
compared to ordinary deuterium lamps.
Despite their compact body, the S2D2 lamps
have the same high stability as conventional
deuterium lamps and a unique electrode
structure that delivers high brightness.

▲Left: L13301
Right: L10671D

Features Characteristics
●Long life: 1500 h (L10671D) ●Spectral distribution ●Directivity (Light distribution)
TLSOB0109EB

●Compact
0.010
L10671D L13301
IRRADIANCE (µW·cm-2·nm-1) at 50 cm

0.009

●High stability: 0.005 %(p-p) typ. 0.008


30°
20°
30°

20°
●High output UV continuous 0.007
10° 10°
0.006
spectrum 0.005
L10671D 0° 0°

●Low power consumption


-10° -10°
0.004
-20° -20°
●Easy to use
0.003
-30° -30°
0.002
L10671P
0.001
L10671D 30° 30°
L10671H 0.000
200 220 240 260 280 300 320 340 360 380 400 20°
20°
WAVELENGTH (nm)
TLSOB0079JB 10° 10°
100
0° 0°
-10° -10°
RELATIVE IRRADIANCE (%)

80
MgF2 (L13301)
-20° -20°
-30° -30°
60
TLS B0005EA TLSOB0114EA
DETECTOR

40

PRINT CIRCUIT BOARD

20
TLS C0005EA

0
100 120 140 160 180 200 220 240 400
WAVELENGTH (nm)

Specifications
Parameter Description / Value Unit
Type No. L10671D L13301 —
Window material UV glass MgF2 —
Spectral distribution 185 to 400 115 to 400 nm
Aperture diameter 1.0 mm
Output stability Drift (Max.) ±0.25 %/h
at 230 nm Fluctuation (p-p) (Typ.) 0.005 %
Guaranteed life at 230 nm A 1500 1000 D h
Output current 30 50 mA
Output voltage (Typ.) Approx. 135 V
Voltage 4.2 V
Warm-up
Current (Typ.) 0.55 A dc
Filament ratings
Voltage 3.5 V
Operating
Current (Typ.) 0.5 A dc
Filament warm-up time (Min.) Approx. 25 s
Bulb wall temperature B (Max.) 185 240 °C
Storage temperature -10 to +60 °C
Storage humidity Below 85 % (No condensation) —
ALamp life end is defined as the point when light output at 230 nm falls to 50 % of its initial value or when output fluctuations exceed 0.05 % (p-p).
11 B Position “a” in dimensional outline COperating life may vary depending on operating environmental conditions (vacuum atmosphere).
Dimensional outline (Unit: mm)
* PCD (Pitch Circle Diameter)
●L10671D ●L13301 O-RING FIXED RANGE TEMPERATURE
MEASUREMENT P.C.D.* 10.72 ± 0.2
TEMPERATURE P.C.D.* 10.72 ± 0.2 15.0 ± 0.5
TEMPERATURE TEMPERATURE POINT a
MEASUREMENT POINT a A 58 MAX. A
MEASUREMENT MEASUREMENT
POINT a 20.5 MAX. 8 MAX. 18° 10° POINT a 20 5 15.5 ± 2.0 8 MAX. 18° 10°
9 × 0.7 9 × 0.7

36°

36°
7 8 7 8

36°

36 °
22 MAX.

9 B 9 B
6 6

20.5
15
5 5 ●CONNECTION
●CONNECTION

36 °

36°
3 6°

36 °
4 1 4 1 1: FILAMENT
3 2 1: FILAMENT 3 2
3 (7): ANODE
3 (7): ANODE ARC POINT 5: AUXILIARY
ARC POINT 7.5 6 9 × 0.7 18° 10° 5: AUXILIARY 7.5 6 9 × 0.7 18° 10° ELECTRODE
ELECTRODE EMISSION POINT POSITION TOLERANCE (CENTER) 9: GND
EMISSION POINT POSITION TOLERANCE (CENTER) 9: GND · With Respect To Axis Line A: ±0.3 mm 2, 4, 6, 8: N.C.
· With Respect To Axis Line A: ±0.3 mm 2, 4, 6, 8: N.C. · With Respect To Axis Line B: ±0.3 mm
· With Respect To Axis Line B: ±0.3 mm
TLSOA0109EA TLSOA0016EA

RELATED PRODUCTS
Power supply
●L10671P (for L10671)
3× 3
CN9: CONNECTOR FOR 12 V CN1: JACK FOR DC INPUT VOLTAGE (MOUNTING HOLE) CN4: CONNECTOR
1: + 3 3 FOR 5 V OUTPUT
Parameter Description / Value Unit 2: – (Usage example: Tungsten Lamp)
1: +
2: –
Input voltage (DC) 12 * V CN2: EXTERNAL CONTROL

3
27
CONNECTOR
CN5: CONNECTOR
Power consumption Max. 10 VA FOR 5 V OUTPUT

65
(Usage example: Shutter Solenoid)
S2D2 lamp ON /OFF — 1: +
2: N.C.

20
CN4 output ON/OFF — 3: –

CN5 output ON/OFF A —

3
8 17 30
55 CN3: CONNECTOR
External control Status signal

18 MAX.
TOP VIEW FOR S2D2 LAMP TOP VIEW
OUTPUT (Bottom Board Only)
S2D2 lamp —

( )
1: GND
2: FILAMENT
CN4
32.5 MAX.
3: N.C.
4: AUXILIARY BOARD = 1.2 mm
Main power ELECTRODE
9.2

5: ANODE
AEach time a signal for external control is input across
2.5 MAX.

SIDE VIEW
terminals 3 and 10, voltages +5 V and -5 V are alternately TLS A0005EA
output at 200 ms intervals.
* Input voltage range is from 8.5 V dc to 13.2 V dc.
1000 ± 100 112.5

●C10707 (for L13301)


Parameter Description / Value Unit
Input voltage (DC) * 10.8 to 13.2 V OUTPUT CABLE
DC JACK
Power consumption Max. 17 VA MAIN POWER LED
EXTERNAL CONTROL
70
Lamp ON /OFF CONNECTOR
External control —
Lamp status signal
42.5

* This power supply come with AC/DC adapter.

Lamp housing Socket with cable E13807 (for L13301)


* PCD (Pitch Circle Diameter)
●L10671H (for L10671D) P.C.D.* 10.72 ± 0.2
3 80 ± 10
Parameter Description / Value Unit 2 × 3.3
Weight 320 g
Optimum operating temperature B +40 to +80 °C
17.5

BAt position “b” in the L10671H dimensional outline. (When this lamp
housing is installed in equipment, thermal design specs must be consid-
ered to ensure the operating temperature will be within this range.) ▼CONNECTION
SOCKET
23 6 1: ANODE
130
TEMPERATURE 2: AUXILIARY ELECTRODE
MEASUREMENT POINT b 2 × M2.6 8 MAX.
3: FILAMENT
4: GND

TOP VIEW SCREWS FOR LAMP CHANGE


26
19 37.5
12 2.5 7.5 5 6 CONNECTOR FOR
CONNECTION TO L10671P
(CN3)
LIGHT
OUTPUT
9.2
29
14

28 5 ARC POINT
ARC
POINT FRONT VIEW 6 SIDE VIEW M11 × 0.5 (DEPTH 3.75) *
2 × 2.7 * 10 mm dia. lens can be placed.
FOR M2.6 FLATHEAD SCREW 13
13

2 × M2.6 DEPTH 2
BOTTOM VIEW
(Screw holes for mounting) TLS A0006EA * Please consult us on the housing and vacuum flange for the L13301.
12
RELATED PRODUCTS
Fiber light source
■APPLICATIONS
●Spectrophotometry ●Microtiter plate reader ●Biological measurement
●Environmental measurement ●Pharmaceutical testing ●Semiconductor inspection
●Absorption spectrum measurement ●High-performance liquid chromatography ●Optical component inspection

Compact UV-VIS S2D2 fiber light source L12515


The L12515 is the world’s smallest UV-visible
fiber light source containing an S2D2®
Features
compact deuterium lamp. Despite its small ●Compact: 72 mm × 40 mm × 90 mm
size, the L12515 delivers high output and high
stability. Its compact, easy-to-carry size and ●High stability: Fluctuation 0.004 % p-p (Typ.)
low voltage operation make it useful for (equivalent 2 × 10-5 A.U.)
various types of portable devices. ●External control
▲L12515
●Shutter function

Light output stability Characteristics


●at 230 nm
20
●Spectral distribution (Typical data)
ABSORBANCE (10-5 A.U.)

15
10
●200 nm to 220 nm ●200 nm to 1100 nm
5
0
(enlarged view of enhanced output region) TLSZB0125EA
1.4 10
-5
-10 L12515 L12515
1.2 L10671 (conventional type) L10671 (conventional type)
-15
-20
RELATIVE IRRADIANCE

TIME (100 s/div.)

RELATIVE IRRADIANCE
1
●at 600 nm 1
20
ABSORBANCE (10-5 A.U.)

0.8
15
10
5
0.6 3
0
0.4
Times 0.1
-5
-10 LIGHT GUIDE LIGHT GUIDE
-15 0.2 A7969-08AS A7969-08AS
Core diameter= 0.8 mm CORE DIAMETER= 0.8 mm
-20
TIME (100 s/div.) 0 0.01
TLSOB0107EA 200 202 204 206 208 210 212 214 216 218 220 200 300 400 500 600 700 800 900 1000 1100

WAVELENGTH (nm) WAVELENGTH (nm)

High power UV-VIS fiber light source L10290


The L10290 is a high power UV-visible fiber light source that outputs 200 nm to 1600 nm light
through a light guide (sold separately). The L10290 utilizes a high brightness deuterium lamp
(X2D2 lamp) to provide radiant intensity that is about twice that of our conventional products. These
features make it easier to use a UV-visible light source with high power and high stability.

Characteristics Features
▲L10290
●Spectral distribution (Typical data) ●High output: Twice intensity
TLSOB0099EB
10 (Compared to conventional model)
L10290
WHEN TUNGSTEN-HALOGEN
LAMP WITH MAX. VOLTAGE
●High stability: Fluctuation 0.004 % p-p (Typ.)
Twice intensity L10290
(equivalent to 2 × 10-5 A.U.)
RELATIVE IRRADIANCE

WHEN TUNGSTEN-HALOGEN
(compared to conventional model) LAMP WITH MIN. VOLTAGE
CONVENTIONAL MODEL ●Long life lamp: 2000 hours
●External control
1
●Shutter function
●Filter holder (Sold separately)
LIGHT GUIDE
A7969-08AS
CORE DIA.= 0.8 mm
0.1
200 300 400 500 600 700 800 900 1000 1100

WAVELENGTH (nm)
13
VUV light source
■APPLICATIONS
●Electrostatic remover ●Semiconductor inspection ●Dechucking of electrostatic chucks
●Film thickness measurement ●Material resistance evalution ●LCD manufacturing equipment
●Spectrophotometry ●Photoionization source

H2D2 light source unit L11798/-01, L11799/-01


The H2D2 light source unit contains a high-brightness, high-end deuterium lamp (H2D2 lamp)
that emits light at a brightness 6 times higher than our current deuterium lamps (L2D2 lamps).
Despite its high brightness, the H2D2 is highly stable, has a long service life, and allows
air-cooled operation by a specially designed housing. This feature makes it much more
convenient and easy to use than ordinary water-cooled lamps.
The H2D2 can be used in various applications and enhances equipment sensitivity and
throughput.
▲L11798, L11799
Left: Light source, Right: Power supply

Features Characteristics
●High brightness: 6 times ●Spectral distribution ●Arc distribution
TLSOB0079EB TLS B0007EB
650
(Compared to L2D2 lamp) 100
600
●High stability: Fluctuation 0.05 % p-p (Max.) 550 High
RELATIVE IRRADIANCE (%)

RELATIVE IRRADIANCE (%)


Drift ±0.3 %h (Max.)
80
L11798/-01 500 brightness
●Long life: Warranty of 1000 hours 60
450
400
×6
350
●Air cooling (needs no cooling water)
H2D2 lamp
300 Conventional model
X2D2 lamp
●External control 40 250
L2D2 lamp
200 ( 0.5 mm)
150
20
100
50
0 0
100 120 140 160 180 200 220 240 400 -2.5 -2 -1.5 -1 -0.5 0 0.5 1 1.5 2 2.5
WAVELENGTH (nm) DISTANCE FROM APERTURE CENTER (mm)

Electrostatic remover VUV ionizer L12542


Due to its wide irradiation angle about 3 times
larger than our current VUV light source, the Characteristics
L12542 efficiently removes electrostatic ●Directivity 30°
charges over large areas in depressurized or 20°
vacuum environments. (Light distribution)
10°
Up until now two or more VUV light sources

were needed to neutralize electrostatic charges
in large areas due to their limited irradiation -10°

angle. The L12542 solves this problem and ▲L12542


-20°

efficiently neutralizes large areas in a vacuum. Left: Light source, Right: Power supply -30° TLSZB0105EA

S2D2 VUV light source unit L10706 series


The S2D2 VUV light source unit is a vacuum
ultraviolet light source unit that incorporates SEM image
a compact deuterium lamp with an MgF 2 ●Comparison of electrostatic change removal effect
window.
Equipped with a SUS flexible tube with a
vacuum flange and a unique cooling mecha-
nism, this light source unit allows irradiating
objects or samples at a very close distance,
and can be installed and operated under
depressurized conditions. ▲L10706
The compact lamp unit and SUS flexible tube Left: Light source, Right: Power supply
▲Before
offer greater flexibility in attaching the light irradiance
source unit to various types of equipment.
▲After irradiance
14
■HANDLING PRECAUTION
1. Deuterium lamps emit ultraviolet rays which can be harmful to eyes and skin. Do not look directly at the emitted light or allow direct exposure to skin.
Always wear protective glasses or goggles and clothing when operating the lamps. (Refer to JIS T 8141 or equivalent safety standards).
2. Since the bulb wall temperature reaches a high temperature (over 200 °C) during lamp operation, do not touch it with bare hands or bring inflam-
mable objects near it.
3. Do not apply vibrations or mechanical shocks to the lamp. These might cause light output stability to deteriorate.
4. Graded sealing of synthetic silica and MgF2 window:
On bulbs using synthetic silica or MgF2 window, the window is formed by so-called "graded sealing" which connects different glasses with slightly
different expansion rates. Since the mechanical strength of the seams of this graded sealing is low, use caution when securing the lamp so that no
force is exerted on those seams during use.
5. Before turning on the lamp, wipe the bulb and window gently using alcohol or acetone. Do not handle the lamp with bare hands. Dirt or smears on
the window will cause a significant drop in ultraviolet transmittance.
6. High voltage is used to operate these lamps. Use extreme caution to prevent electrical shock.
7. Be sure to avoid to store the lamp under high humidity and high temperature. Also, in case the lamp is not used for a long time, it with package in
the place where shock or vibration is not applied.
8. Handling MgF2 and synthetic quartz windows:
UV light generates ozone when it irradiates an atmosphere containing oxygen. The amount of the generated ozone is low and so does not affect the
human body but does produce an ozone smell. So ventilate the room from time to time when using a lamp with an MgF2 or synthetic quartz window
in a closed room.

■WARRANTY
Lamps are warranted for a period of one year from the date of shipment. If a lamp is found to be defective within this warranty period, Hamamatsu will
replace the defective lamp without charge. (This warranty is limited to replacement of the defective lamp.) Even if within the warranty period (one
year), the warranty shall not apply to cases where the lamp operation time has exceeded the guaranteed life, or the trouble was caused by incorrect
operation or natural or man-made disasters.

■DISPOSAL OF LAMPS
When disposing of the used lamp, take appropriate measures in compliance with applicable regulations regarding waste disposal and correctly
dispose of it yourself, or entrust disposal to a licensed industrial waste disposal company.
In any case, be sure to comply with the regulations in your country, state, region or province to ensure the used lamp is disposed of legally and
correctly.

Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office.
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are
subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2017 Hamamatsu Photonics K.K.

HAMAMATSU PHOTONICS K.K. www.hamamatsu.com


HAMAMATSU PHOTONICS K.K., Electron Tube Division
314-5, Shimokanzo, Iwata City, Shizuoka Pref., 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, NJ 08807, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: usa@hamamatsu.com
Germany: Hamamatsu Photonics Deutschland GmbH.: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-265-8 E-mail: info@hamamatsu.de
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: infos@hamamatsu.fr
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court,10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, UK, Telephone: (44)1707-294888, Fax: (44)1707-325777 E-mail: info@hamamatsu.co.uk
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46)8-509 031 00, Fax: (46)8-509 031 01 E-mail: info@hamamatsu.se
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39)02-93 58 17 33, Fax: (39)02-93 58 17 41 E-mail: info@hamamatsu.it
China: Hamamatsu Photonics (China) Co., Ltd.: 1201 Tower B, Jiaming Center, 27 Dongsanhuan Beilu, Chaoyang District, 100020 Beijing, China, Telephone: (86)10-6586-6006, Fax: (86)10-6586-2866 E-mail: hpc@hamamatsu.com.cn TLS 1017E02
Taiwan: Hamamatsu Photonics Taiwan Co., Ltd.: 8F-3, No.158, Section2, Gongdao 5th Road, East District, Hsinchu, 300, Taiwan R.O.C. Telephone: (886)03-659-0080, Fax: (886)03-659-0081 E-mail: info@tw.hpk.co.jp NOV. 2017 IP

You might also like