You are on page 1of 54

BUILDING SCHEDULE OF RATES EFFECTIVE FROM

2018 JANUARY
SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION I - MASONRY WORKS.

1 B-001 Brick work in 1:5 cement sand mortar 225mm thick 3


m 18,918.83
(Nominal)and above in foundations up to D.P.C .
2 B-002 Brick work in 1:8 cement sand mortar 225mm thick (Nominal)in
super structure in ground floor. m3 18,971.04
3 B-003 Brick work in 1:5 cement sand mortar 112.5mm thick (Nominal) 2
m 2,400.77
in ground floor.
4 B-004 Brick work in 1:5 cement sand mortar 112.5mm thick (Nominal)
using available bricks. m2 1,290.12
5 B-005 Brick work in 1:8 cement & sand mortar 225mm thick (Nominal)
or above. (using available bricks) m3 7,954.45
6 B-006 Brick work in 1:5 Cement Sand Mortar 225mm thick (nominal)
Large brick in ground floor. m2 2,898.72
7 B-007 Brick work in 1:5 Cement Sand Mortar 150mm thick (nominal)
Large brick in ground floor. m2 1,919.13
8 B-008 Masonry block work 100mm thick (Nominal) in walls in cement
and sand 1:5 motar using hollow blocks made of cement and
sand to the proportion of 1:10, confirming to compressive m2 1,634.46
strength not less than 2N/mm2 in ground floor.

9 B-009 Masonry block work 150mm thick (Nominal) in walls in cement


and sand 1:5 motar using hollow blocks made of cement and
sand to the proportion of 1:10, confirming to compressive m2 1,880.26
strength not less than 2N/mm2 in ground floor.

10 B-010 Masonry block work 200mm thick (Nominal) in cement and sand
1:5 motar using hollow blocks made of cement and sand to a
proportion of 1:10, confirming to compressive strength not less m2 2,494.19
than 2N/mm2 in ground floor.

11 B-011 R.R masonry in 1:5 cement and sand motar in foundations using
available rubble. m3 12,033.90
12 B-012 R.R masonry in 1:5 cement and sand motar in foundations. m3 14,395.10
13 B-013 R.R masonry in 1:5 cement and sand motar in superstructure.
m3 15,754.05
14 B-014 Provision of weep holes in retaining walls with 90mm dia. PVC
down pipes including metal packing around inner mouth as nr 585.72
directed, length of pipe up to 1050mm.
15 B-015 Provision of weep holes in retaining walls with 90mm dia. PVC
down pipes including metal packing around inner mouth as nr 724.61
directed, length of pipe 1200mm to 1650mm.
16 B-016 Provision of weep holes in retaining walls with 90mm dia. PVC
down pipes including metal packing around inner mouth as nr 860.11
directed, length of pipe 1800mm to 2250mm.

Recommended by the Price Comitee - 2018 Page 1


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION II - CONCRETOR

17 C-001 Mixing and placing in position concrete grade 30, nominal mix
1:1:2 (20mm) using a concrete mixer including fuel / operator / m3 25,476.14
handling/vibrator.
18 C-002 Mixing and placing in position concrete grade 25, nominal mix
1:11/2:3 ( 20mm) using a concrete mixer including fuel / operator m3 21,757.57
/ handling/vibrator.
19 C-003 Mixing and placing in position concrete grade 20, nominal mix
1:2:4 ( 20mm) using a concrete mixer including fuel / operator / m3 20,424.98
handling/vibrator.
20 C-004 Mixing and placing in position concrete 1:21/2:5(25mm) using a
concrete mixer including fuel / operator / handling/vibrator. m3 15,877.36

21 C-005 Mixing and placing in position concrete 1:3:6 (40mm) using a


concrete mixer including fuel / operator / handling. m3 15,505.18
22 C-006 Tor steel reinforcement bend to shape laid in position and tied
kg 273.75
with G.I. wire as directed.Including spaces & chairs.
23 C-007 Mild steel reinforcement bend to shape laid in position and tied
kg 273.75
with G.I. wire as directed.Including spaces & chairs.
24 C-008 Sawn timber formwork in class III timber for columns, ground
floor. m2 2,525.30
25 C-009 Sawn timber form work in class III timber for underside of
ground floor slabs. m2 1,465.46
26 C-010 Sawn timber form work in class III timber for concrete beams.
m2 3,293.93
27 C-011 Sawn timber formwork in class III timber for portal frames.
m2 2,254.65
28 C-012 Sawn timber formwork in class III timber for ground concrete
work,at ground level plinth beams,lintols etc. m2 1,365.51
29 C-013 2400mm x 600mm x 450mm plat form with 75mm thick 1:3:6
(40mm) base & 2400mm x 300mm x 225mm step in rubble and
75mm thick 1:2 1/2:5 (25mm) concrete topping. Inclusive of 1:3
cement and sand rendering finished smooth with coloured cement
floating and polishing and providing three numbers 2"dia.,4.5mm nr 71,560.75
tk. G.I.pipe flag post complete with painting and provide
necessary arrangements for hoisting the flag as per the drawing
No.CPC/CS/11/04/2017/Type-ST/02(i).

Recommended by the Price Comitee - 2018 Page 2


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
30 C-014 3300mm x 1350mm x 1050mm platform for Flag Post (Type-1)
with 1:2:4 (20mm) concreteand 1:3 cement and sand rendering
finished smooth with coloured cement floating and polishing and
providing three numbers 2" dia.(4.5mm tk) G.I.pipe flag post
complete with painting and provide necessary arrangements for nr 127,507.30
hoisting the flag. All shall be to working order as per the drawing
No.CPC/CS/11/04/2017/Type-ST/02(ii).

31 C-015 Concrete catch pits / valve chambers in 50mm thick 1:2:4(20mm)


concrete side walls and internal faces cement rendered with 1:3
cement and sand finished smooth, to be water tite, inclusive of
provision for necessary pipe connection etc, with suitable cover nr 917.07
or grating on top to be flush with floor level. Internal dimensions
150mm x 150mm x 300mm.

32 C-016 Concrete catch pits / valve chambers in 50mm thick 1:2:4(20mm)


concrete side walls and internal faces cement rendered with 1:3
cement and sand finished smooth, to be water tite, inclusive of
provision for necessary pipe connection etc, with suitable cover nr 1,168.67
or grating on top to be flush with floor level. Internal dimensions
150mm x 150mm x 450mm.

33 C-017 Concrete catch pits / valve chambers in 50mm thick 1:2:4(20mm)


concrete side walls and internal faces cement rendered with 1:3
cement and sand finished smooth, to be water tite, inclusive of
provision for necessary pipe connection etc, with suitable cover nr 2,503.10
or grating on top to be flushed with floor level. Internal
dimensions 300mm x 300mm x 450mm.

34 C-018 Drain 225mm X 150mm (average depth) concrete 1:21/2:5


(25mm) 75mm thick, provide expansion joints at 3000mm crs
12mm thick , 1:3 cement, sand rendering finished smooth,
including necessary excavation, form work, laying polythene m 2,185.17
membrane under concrete and laid to required slope.

35 C-019 Drain 225mm X 300mm(average depth) concrete 1:2 1/2:5


(25mm) 75mm thick, provide expansion joints at 3000mm crs
12.5mm thick , 1:3 cement, sand rendering finished smooth,
including necessary excavation, form work, laying polythene m 2,604.52
membrane under concrete and laid to required slope.

36 C-020 Drain 225mm x 450mm(average depth) concrete 1:2 1/2:5


(25mm) 75mm thick, provide expansion joints at 3000mm crs
12.5mm thick , 1:3 cement, sand rendering finished smooth,
including necessary excavation, form work, laying polythene m 4,462.33
membrane under concrete and laid to required slope.

Recommended by the Price Comitee - 2018 Page 3


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
37 C-021 750mm wide ramp and 225mm X 150mm(average depth) drain in
1:2 1/2:5(25mm) concrete 75mm thick with 1:3 plaster finished
smooth, including necessary excavation, form work, providing
expansion joints at 3000mm crs and laying polythene membrane m 3,792.92
under concrete and laid to required slope.

38 C-022 Concrete cover slabs 50mm thick 1:2:4 (20 mm) r/f with, 6mm
dia. MS bars at bottom @ 100mm centre. both ways, 1:3 cement
and sand rendering finished smooth, pre-cast in, pieces not m2 4,365.13
exceeding 600mm x 450mm placed in position as directed,
providing drain holes if required.
39 C-023 Extra over concrete chamber for earth electrode in 50mm thick
1:2:4(20mm) concrete side walls with R.C.C cover slab on top.
nr 1,228.73
internal dimensions 150mm x 150mm x 300mm.

40 C-024 Rate of placing, porker vibrating, leveling and curing of Ready


mixed concrete of any grade. (Cost of Ready mix concrete is not m3 856.25
included.)
Add.
Cost of Ready mix concrete of required grade up to 15km.
m3
Minimum charge for pumping car (up to 30m3 ) up to 15km
Sum 18,000.00
Additional charge for pumping concrete (exceeding 30m3) up to
15km m3 600.00
Transport over 15km
Transport charges for pumping car over 15km km 70.00
Ready mixed Concrete Transport beyond 15km 3
m 40.00
Hoisting m3
(Either pumping or hoisting could be used)
Total A
Add.
20% overhead & profit
Total B
Ready mixed concrete rate - A + B
Ready mixed concrete rates as per item no 43-47 of Material
Prices and Transport rates 2017
Raedy mixed concrete (grade 15) up to 15km 3
m 12,400.00
Raedy mixed concrete (grade 20) up to 15km 3
m 13,000.00
Ready mixed concrete (grade 25) up to 15km 3
m 13,425.00
Ready mixed concrete (grade 30) up to 15km 3
m 14,000.00
41 C-025 Mixing and placing in position concrete 1:3:6 (40mm) manualy
m3 16,183.45
42 C-026 Mixing and placing in position concrete 1:21/2:5(25mm) manualy 3
m 16,555.63
43 C-027 Mixing and placing in position concrete grade 20, nominal mix 3
m 21,103.25
1:2:4 ( 20mm) manualy

Recommended by the Price Comitee - 2018 Page 4


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION III - DEMOLISHER

44 D-001 Removing asbestos ceiling including timber framework, stacking


serviceable materials and debris cleared away. in single storied m2 492.92
building.
45 D-002 Removing asbestos ceiling including timber frame work,
stacking serviceable materials and debris cleared away in two m2 547.69
storied building.
46 D-003 Removing & stacking partitions, weld mesh, shelves from 2
m 229.50
existing walls.
47 D-004 Demolishing and clearing debris of 225mm wide drain in brick
m 210.88
masonry.
48 D-005 Demolishing & clearing debris away of floor paving brick,
concrete or rubble inclusive of rendering.. m2 212.87
49 D-006 Removing & clearing debries away Corrugated sheets, iron,
asbestos or aluminium alloy from roof including frame work
inclusive of wiring and fixtures, gutters, valance boards etc.. in m2 172.96
single storied buildings.
50 D-007 Removing & clearing debries away Corrugated sheets, iron,
asbestos or aluminium alloy from roof including frame work
inclusive of wiring and fixtures, gutters, valance boards etc.. in m2 186.26
two storied buildings.
51 D-008 Removing & clearing debries away Corrugated sheets, iron,
asbestos or aluminium alloy from roof including frame work
inclusive of wiring and fixtures, gutters, valance boards etc.. in m2 199.57
three storied buildings.
52 D-009 Removing & clearing debries away tiled roof with frame work
inclusive of wiring and fixtures, gutters, valance boards etc.,
stacking serviceable materials and debris cleared away in single m2 279.40
storied buildings.
53 D-010 Removing & clearing debries away tiled roof with frame work
inclusive of wiring and fixtures, gutters, valance boards etc.,
stacking serviceable materials and debris cleared away in two m2 385.83
storied buildings.
54 D-011 Removing & clearing debries away tiled roof with frame work
inclusive of wiring and fixtures, gutters, valance boards etc., 2
m 492.27
stacking serviceable materials and debris cleared away in three
storied buildings.
55 D-012 Removing & clearing debries away tiles calicut or half round,
removed from roof of single storied buildings including stacking 2
m 106.44
serviceable materials and debris cleared away.

56 D-013 Removing & clearing debries away tiles calicut or half round,
removed from roof of two storied buildings including stacking m2 159.66
serviceable materials and debris cleared away.

Recommended by the Price Comitee - 2018 Page 5


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
57 D-014 Removing & clearing debries away tiles calicut or half round,
removed from roof of three storied buildings and above, 2
m 212.87
including stacking serviceable materials and debris cleared away.

58 D-015 Removing and stacking trusses steel or timber 6.1m (20 Left) of
nr 4,051.20
span from single storied building.
59 D-016 Removing and stacking trusses steel or timber 7.6m (25 L.ft) of
nr 5,064.00
span from single storied building.
60 D-017 Removing and stacking trusses steel or timber 9.1m (30 L.ft) of
nr 6,076.80
span from single storied building.
61 D-018 Demolishing bricks walls 112.5mm thick inclusive of plaster and
any fixtures including debris cleared away. m2 425.75
62 D-019 Demolishing bricks walls above 225mm thick inclusive of 3
m 1,746.38
plaster and any fixtures including debris cleared away.
63 D-020 Demolishing rubble masonry in cement and sand inclusive of
plaster and any fixtures, rubble stacked and removing debris . m3 2,172.38

64 D-021 Demolishing reinforced concrete walls, beams or slabs up to first


floor and debris cleared away. m3 13,952.38
65 D-022 Demolishing reinforced concrete walls, beams or slabs up to
second floor and debris cleared away. m3 14,667.89
66 D-023 Demolishing reinforced concrete walls, beams or slabs up to third
floor and debris cleared away. m3 15,741.15
67 D-024 Removing & stacking door or window size up to 4.0m2 from
nr 1,968.00
existing walls.
68 D-025 Removing & stacking Door or window size over 4.0m2.from
nr 2,952.00
existing walls.
69 D-026 Removing & stacking Door or window sash size up to 4.0m2 .
from existing frames. m2 238.32
70 D-027 Removing & stacking Door or window sash only size over 4.0m2
from existing frame. m2 357.48
71 D-028 Removing & stacking Gutters, down pipes, valleys GI or PVC
m 53.53
including specials .
72 D-029 Removing & stacking Boards, valance and barge. m 40.55
73 D-030 Low-level suits, squatting closets. nr 787.20
74 D-031 Removing & stacking Wash basins, cisterns, sinks, urinals. nr 492.00
75 D-032 Removing & stacking Ridges, asbestos or tile. m 77.86
76 D-033 Removing & stacking Pipes PVC, GI. m 25.83
77 D-034 Chipping & clearing debris away from brick wall plasters and 2
m 238.32
floor rendering.
78 D-035 Chipping & clearing debris away from concrete wall plasters and 2
m 357.38
concrete floor rendering.
79 D-036 Uprooting & stacking all materials barbed wire upto 5 strands
fence (Barbed wire tobe rolled up,Length of the fence to be m 306.71
measured).
80 D-037 Demolishing & clearing tiled, glazed floor or wall. m2 423.68

Recommended by the Price Comitee - 2018 Page 6


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
SECTION IV - EXCAVATOR

81 E-001 Earth excavation in levelling site inclusive of haulage up to 3


m 1,078.38
30m. (manual cutting only up to 450m3)
82 E-002 Earth excavation in levelling site inclusive of haulage up to
30m. (machine cutting only) in ordinary soil. m3 183.68
* Total excavation rate A + B
83 E-003 Excavation in foundations in normal earth up to depth of 1.5m
inclusive of backfilling, compacting and disposal of surplus earth. m3 1,599.75

84 E-004 Excavation in foundations in soft rock requiring manual digging,


up to a depth of 1.5m inclusive of backfilling and disposal of m3 2,139.00
surplus materials.
85 E-005 Rock Requaring blasting & pilling inclusive of haulage up to 30
m. Payable on rubble measurement only. (Rubble volume m3 4,517.76
measured as - Pilling measurment X 0.75)
86 E-006 Rock Requaring blasting and remove the blasted rock from the
site (within 10km) m3 4,899.25
87 E-007 Excavation in levelling site in soft rock involving manual digging
inclusive of haulage up to 30 m. m3 2,121.12
88 E-008 Excavation in wells / pits in normal earth up to depth of 1.5m
inclusive of backfilling behind wall / ring and disposal of surplus m3 1,773.54
earth, rate excluding for shoring.
89 E-009 Excavation in wells / pits in normal earth 1.5m to 3.0m depth
inclusive of backfilling behind wall /ring and disposal of surplus m3 2,468.70
earth, rate excluding for shoring.
90 E-010 Excavation in wells / pits in normal earth 3.0m to 4.5m depth
inclusive of backfilling behind wall /ring and disposal of surplus m3 3,511.44
earth, rate excluding for shoring.
91 E-011 Excavation in wells / pits in normal earth 4.5m to 6.0m depth
inclusive of backfilling behind wall /ring and disposal of surplus m3 4,572.06
earth, rate excluding for shoring.
92 E-012 Filling earth and compacting (as approved by Engineer) 150mm
layers in large quantities. Rate includes for transport of 30 m. m3 1,252.17

93 E-013 Filling earth and compacting (as approved by Engineer) 150mm


3
layers under floors. Rate includes for transport of 30 m. m 1,443.84

94 E-014 Shoring for excavations up to 3m height.All as per detail drawing 2


m 799.99
No .CPC/CS/11/04/2017/Type-ST/03
95 E-015 Bailing out and cleaning of well total depth up to 3.0m
(measured, capacity of well below water table). m3 527.94
96 E-016 Bailing out and cleaning of well total depth up to 4.8m
(measured, capacity of well below water table). m3 1,055.87
97 E-017 Bailing out and cleaning of welltotal depth up to 7.5m (measured,
capacity of well below water table). m3 1,478.22

Recommended by the Price Comitee - 2018 Page 7


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
98 E-018 Extra over excavation for removing boulders size exceeding
0.05m3,in any manner (Volume of each boulder measured as 0.75 m3 3,428.57
x Average height x Squared area).
99 E-019 Depositing and spreading haulage of earth more than 30m away
from site by any means. m3 423.88
100 E-020 Levelling ground to required grading cutting lumps and spreading 2
m 42.37
and compacting manually.
101 E-021 Disposal of surplus earth, inclusive of loading and unloading and
transport up to 10 km.(Using Mechine) m3 313.67
102 E-022 Compacting approved gravel, filled in 150mm layers by manual
tamping as specified. (Gravel available at site) m3 1,048.09
103 E-023 Suplying and spreading river sand in layers as specified under
3
foundations, drainage sand blankets, filters, around soakage pits, m 4,934.86
wells etc.
104 E-024 Compacting approved gravel in 150mm layers by any means
except manual tamping as specified. (Gravel available at site) m3 529.85

105 E-025 Rock excavation in column footings or wall foundations. m3 5,722.84


106 E-026 Sand filling under foundations. (As a cushion) m
3
5,011.25

Recommended by the Price Comitee - 2018 Page 8


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION V - PAVIOR

107 F-001 62mm thick floor paved with brick, and rendering 1:3 cement ,
finishing smooth with gray cement floating with expansion joints
filled in 1:2 bitumen and sand. (Rate including for brick paved m2 2,931.21
with 2:5 lime mortar and curing)
108 F-002 62mm thick floor paved with brick, and rendering 1:3 cement ,
finishing smooth with gray cement floating with expansion joints
filled in 1:2 bitumen and sand. (Rate including for brick paved m2 2,271.11
with 2:5 lime mortar and curing). Bricks available at site.

109 F-003 Floor concrete with 1:2 1/2:5(25mm) 75mm thick, 1:3 normal
cement and sand rendering finished smooth with expansion joints
filled with 1:2 bitumen and sand. Rate including for curing, m2 2,151.79
compacting ground and laying polythene sheets under the
concrete.
110 F-004 Floor concrete with 1:2 1/2:5(25mm) 62mm thick, 1:3 normal
cement and sand rendering finished smooth with expansion joints
filled with 1:2 bitumen and sand. Rate including for curing, m2 1,758.39
compacting ground and laying polythene sheets under the
concrete.
111 F-005 Floor concrete with 1:2 1/2:5(25mm) 75mm thick with expansion
joints filled with 1:2 bitumen and sand rate including for the
curing, compacting ground and laying polythene sheet under the m2 1,237.95
concrete.
112 F-006 Floor concrete with 1:2 1/2:5(25mm) 62mm thick with expansion
joints filled with 1:2 bitumen and sand rate including for the
curing, compacting ground and laying polythene sheet under the m2 844.55
concrete.
113 F-007 Extra over supplying & fixing tile beading (Small) m 92.12
114 F-008 Extra over Supplying & fixing tile beading (Large) m 109.09
115 F-009 Floor paving with approved pattern and colour
ceramic floor tiles on 1:3 cement mortar, joints filled with tile
grout, to match the colour of tiles and cleaning. (Cost of tile is m2 2,053.64
not included)
Add only the cost of tile + 20% overhead and profit per m2
(Tile) for the above rate.
* Total floor tiling rate A + B
116 F-010 100mm high tile skirting approved pattern and colour ceramic
floor tiles on 1:3 cement mortar, joints filled with tile grout to
m 312.98
match the colour of tiles and cleaning. (Cost of tile is not
included)
Add only the cost of tile + 20% overhead and profit per "m"
(Tile skirting) for the above rate.
* Total tile skirting rate A + B

Recommended by the Price Comitee - 2018 Page 9


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
117 F-011 Floor re-rendering with 1:3 cement and sand after demolishing
and clearing damaged areas, providing expansion joints filled in 2
m 1,085.95
1:2 bitumen and sand (Rate including for curing).

118 F-012 Floor rendering with 1:3 cement and sand, normal cement floated
surface with expansion joints filled with 1:2 bitumen sand.( Rate m2 913.83
including for curing)
119 F-013 Extra over, for waxing and polishing coloured cement floor .
m2 178.65
120 F-014 100mm high skirting in cement and sand 1:3 projected or flush to
walls finished smooth with gray cement floating including m 527.50
forming groove.
121 F-015 Waterproofing in upper floor bathrooms, water tanks etc. with
waterproofing agent approved by the Engineer, (Barralastic or
equivalent) apply two coats after well cleared surface. m2 2,057.44

122 F-016 Floor rendering with 1:3 cement and sand approved coloured
surface with expansion joints filled with 1:2 bitumen and sand. m2 1,162.89
(Rate including for curing)
123 F-017 100mm high skirting in cement and sand 1:3 finished smooth
m 567.13
with coloured cement including forming groove.
124 F-018 Paving interlock blocks (strength 25N/mm2 rough gray colour /
normal) nominal thickness 80mm with quarry dust bedding
including compacting and levelling (Earth levelling and m2 2,530.34
compacting measured seperatly)
125 F-019 Paving interlock blocks (strength 25N/mm2 rough) nominal size
thickness 80mm rough colour with quarry dust bedding
including compacting and levelling (Earth levelling and m2 2,776.92
compacting measured seperatly)
126 F-020 Floor paved with approved pattern and colour floor tiles
(homogeneous /porcelain) with tile mortar on 1:3 cement mortar,
joints filled with tile grout to match the colour of tiles and m3 2,234.34
cleaning. (Tile rate not included)
127 F-021 100mm high tile skirting approved pattern and colour floor tiles
(homogeneous / porcelain) on 1:3 tile mortar, joints filled with 3
m 340.52
tile grout to match the colour of tiles and cleaning. (Tile rate not
included)

Recommended by the Price Comitee - 2018 Page 10


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
SECTION VI - MISCELLANEOUS / GENERAL

128 G-001 Clearing jungle along the fence. m 64.57


129 G-002 Cutting coconut trees removing root balls and stacking logs.
nr 6,396.00
130 G-003 Cutting coconut trees and removing stumps. nr 4,428.00
131 G-004 Cutting trees girth 0.45m to 0.9m, removing root balls and
nr 10,382.40
stacking logs.
132 G-005 Cutting trees girth 0.45m to 0.9m and stacking logs. nr 6,427.20
133 G-006 Cutting trees girth 0.925m to 1.35m, removing root balls and
nr 14,832.00
stacking logs.
134 G-007 Cutting trees girth 0.925m to 1.35m and stacking logs. nr 10,876.80
135 G-008 Cutting trees girth 1.375m to 1.8m, removing root balls and
nr 21,259.20
stacking logs.
136 G-009 Cutting trees girth 1.375m to 1.8m and stacking logs. nr 17,304.00
137 G-010 Cutting trees girth 1.825m to 2.25m, removing root balls and
nr 29,664.00
stacking logs.
138 G-011 Cutting trees girth 1.8m to 2.25m and stacking logs. nr 25,708.80
139 G-012 Cutting trees girth 2.2m to 2.7m, removing root balls and stacking
nr 36,091.20
logs.
140 G-013 Cutting trees girth 2.2m to 2.7m and stacking logs. nr 32,136.00
141 G-014 Barbed wire fence, 7strands 14 BWG with 4 points at 75mm crs
and R.C.C posts 1:1 1/2:3 (20mm) concrete 1.70m high and
section 150mm x 150mm at bottom and 100mm x 100mm at top,
at 2.4m c/c , r/f with 4 nos 6mm dia. MS rods with 14BWG wire
stirrups at 150mm crs. Rate to include for m 1,495.40
excavation,1:3:6(40mm) cement concrete foundations to all posts
and providing straightening bolts with washers and nuts.All as
per detail drawing No .CPC/CS/11/04/2017/Type-ST/05

142 G-015 Barbed wire fence, 10 strands 14 BWG with 4 points at 75mm
crs and R.C.C posts 1:1 1/2:3 (20mm) concrete 2.25m high and
section 150mm x 150mm at bottom and 100mm x 100mm at top,
at 2.4m c/c, r/f with 4 nos 6mm dia. MS rods with 14BWG wire
stirrups at 150mm crs. Rate to include for m 1,769.65
excavation,1:3:6(40mm) cement concrete foundations to all posts
and providing straightening bolts with washers and nuts.

143 G-016 Casting & errecting fence posts (intermediate or struts) in cement
concrete 1:1 1/2:3(20mm) r/f with 4 nos 6mm dia. MS rods and
14BWG wire stirrups at 150crs, 1.7m high and section 150mm x
150mm at bottom and 100mm x 100mm at top, as per detail nr 2,526.79
drawing including fixing with 1:3:6 concrete, excavation etc.All
as per detail drawing No .CPC/CS/11/04/2017/Type-ST/11

Recommended by the Price Comitee - 2018 Page 11


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
144 G-017 Casting & errecting fence posts (intermediate or struts) in cement
concrete 1:1 1/2:3(20mm) r/f with 4 nos 6mm dia. MS rods and
14BWG wire stirrups at 150crs, 2.25m high and section 150mm x
150mm at bottom and 100mm x 100mm top, as per detail drawing nr 2,992.74
including fixing with 1:3:6 concrete, excavation etc.All as per
detail drawing No .CPC/CS/11/04/2017/Type-ST/11

145 G-018 Refixing available RCC fence posts , Rate includes for concreting
nr 754.27
1:3:6(40mm) where necessary.
146 G-019 Strengthing & fixing available barbed wire 14 gauge 4 points, on
m 28.44
exiting concrete or timber fence posts.
147 G-020 Suppling & fixing barbed wire 14 gauge 4 Points,on existing
m 38.38
concrete or timber fence posts.
148 G-021 Constructing flight of steps in 1:2 1/2 :5(25mm) concrete overall
width 1.5m, waist 100mm on well compacted ground, waist
below ground level, curb walls 150mm thick overall height
450mm in outer surface. Rate includes all formwork and 1:3 m 13,872.75
cement rendering finished smooth to exposed surfaces. size of
steps 150 mm rise and 275mm tread.(Measured sloping length.)

149 G-022 Constructing landing flight of steps 1.5m wide overall base
100mm thick, curb walls 150mm thick and 150mm height
m 11,867.06
externally, in 1:2 1/2:5(25mm) concrete, and 1:3.cement
rendering finished smooth.
150 G-023 Constructing chain link mesh fence 2.0m high (Gauge 12) with 2"
dia. medium quality GI pipe at 2.4m c/c up rights and one after
the other 3/4" dia. medium quality GI pipe up right at 2.4m c/c
and 1" dia. GI pipe medium quality at top and bottom runners,
including excavation, foundation concrete work 1:2:4(20mm), m 8,757.03
welding work, painting of two coats of anticorrosive and finished
coat of enamel etc.(Chain link fence open area 2" x 2") All as per
detail drawing No .CPC/CS/11/04/2017/Type-ST/01

151 G-024 Supplying and laying 1.5m x 1.0m x 1.0m galvanized gabion
nr 14,855.90
boxes with necessary rubble packing.
152 G-025 Supplying and laying 2.0m x 1.0m x 1.0m galvanized gabion
nr 19,886.10
boxes with necessary rubble packing.
153 G-026 Supplying and laying 1.0m x 1.0m x 1.0m galvanized gabion
nr 10,623.06
boxes with necessary rubble packing.
154 G-027 Supplying and laying geo textile layer behind gabion retaining
walls type T.S. 30. m2 236.78
155 G-028 Cutting turf sods, loading to hand carts and transporting up to 30
m, laying and watering for 30days. (Royalty for turf sods, and m2 347.07
transport beyond 30m paid separately)
156 G-029 Preparing a filter layer behind the retaining wall using 6" dia.
perforated T600 PVC pipe, geo textile , 3/4" metal packing and
m 5,589.29
river sand as per the detailed drawing
No.CPC/CS/11/04/2017/Type-ST/04

Recommended by the Price Comitee - 2018 Page 12


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
157 G-030 Waterproofing with cementitious waterproofing agent approved
by the Engineer, (Xypex or equivalent) apply two coats after well m2 2,282.63
cleareing and preparation of surface.
158 G-031 Waterproofing with cementitious waterproofing agent approved
by the Engineer, (Thoroseal or equivalent) apply two coats after
well well cleareing and preparation of surface. m2 1,174.86

Recommended by the Price Comitee - 2018 Page 13


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION VII - DRAINAGE SYSTEMS

159 H-001 Supplying and fixing elbow pvc 110mm. nr 1,227.42


160 H-002 Supplying and fixing, Cleaning eye bend pvc (89D) 110mm.
nr 1,097.73
161 H-003 Supplying and fixing bend PVC 110 for drainage. nr 812.91
162 H-004 Supplying and laying type 400 pvc 110mm for sewer line in
medium soil, joints embedded in 1:3:6(40mm) concrete including
m 948.52
necessary excavation, back filling, and compaction, invert depth
up to 600mm.
163 H-005 Supplying and laying type 400 pvc 110mm for sewer line in
medium soil, joints embedded in 1:3:6 (40mm) concrete
m 1,097.11
including necessary excavation, back filling, and compaction
invert depth up to 600mm to 900mm.
164 H-006 Supplying and laying type 400 pvc 160mm for sewer line in
medium soil, joints embedded in 1:3:6(40mm) concrete including
m 2,564.13
necessary excavation, back filling, and compaction invert depth
up to 600mm.
165 H-007 Supplying and laying type 400 pvc 160mm for sewer line in
medium soil, joints embedded in 1:3:6(40mm) concrete including
m 2,712.72
necessary excavation, back filling, and compaction invert depth
to 600mm to 900mm.
166 H-008 Supplying and fixing gully PVC 150mm including concreting and
nr 739.37
supplying necessary grating.
167 H-009 Construction of manhole 600mm x 600mm x 600mm internally
complete with cement concrete 1:2:4(25mm) in 75mm thick base,
225mm tk.brick walls on top of base slab and channelling &
bending, 1:3 cement and sand rendered in internal surfaces, nr 18,963.68
75mm thick RC. cover slab r/f with 10mm tor steel @ 150mm
c/c. both ways, complete with lifting handles.

168 H-010 Construction of manhole 600mm x 600mm internally complete


with brick walls 1:3 cement and sand rendered in internal
nr 5,668.86
surfaces, extra over for each additional 0.3m depth.

169 H-011 Construction of manhole 1.05m x 0.675m x 0.60m internally


complete with cement concrete 1:2:4(25mm) in 75mm thick base,
225mm tk.brick walls on top of base slab and channelling and
bending, 1:3 cement and sand rendered in internal surfaces, nr 29,061.51
75mm thick RC. cover slab r/f with 10mm tor steel @ 150mm
c/c. both ways, complete with lifting handles.

170 H-012 Construction of manhole 1.05m x 0.675m internally brick walls


225mm , 1:3 cement and sand rendered in internal surfaces extra nr 7,519.73
over each additional 0.3 m depth.

Recommended by the Price Comitee - 2018 Page 14


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
171 H-013 Shallow drains in floors 75mm diameter in cement concrete
1:2:4(25mm), 75mm thick in bottom and sides including cement m 1,705.69
and sand rendering.
172 H-014 Construction of 1.2m diameter internal fully built type soakage
pit, built up 225mm thick brick work in 1:8 cement ,sand mortar
invert depth from ground level 3.0m,on 225mm x 150mm ring
beam 1:2:4(20mm) concrete mix, including 1:3 cement,sand
plaster finished smooth with neat gray cement (0.9m invert depth
only) & 100mm high 1:2:4(20mm ) concrete ring pad above nr 138,110.04
ground level, complete with 75mm thick RCC cover slab with
lifting handle.All as per detail drawing
No.CPC/CS/11/04/2015/TYPE-SP/03.

173 H-015 Construction of 1.2m diameter internal semi built type soakage
pit, built up 225mm thick brick work in 1:8 cement and sand
mortar invert depth from ground level 0.90m, on 225mm x
150mm ring beam 1:2:4(20mm) concrete mix, including 1:3
cement and sand plaster finished smooth with neat gray cement nr 59,452.13
& 100mm high 1:2:4(20mm ) concrete ring pad above ground
level, complete with 75mm thick RCC cover slab with lifting
handle. All as per detail drawing No.CPC/CS/11/04/2015/TYPE-
SP/04
174 H-016 Construction of 1.8m diameter internal fully built type soakage
pit , built up 225mm thick brick work in 1:8 cement ,sand mortar
invert depth from ground level 3.0m, on 225mm x 150mm ring
beam 1:2:4(20mm) concrete mix, including 1:3 cement and sand
plaster finished smooth with neat gray cement (0.9m invert depth
only) & 100mm high 1:2:4(20mm ) concrete ring pad above nr 200,399.39
ground level, complete with 75mm thick RCC cover slab with
lifting handle. All as per detail drawing
No.CPC/CS/11/04/2015/TYPE-SP/05

175 H-017 Supplying and fixing Tee, pvc 110mm for drainage. nr 1,088.79
176 H-018 Supplying and fixing of vent pvc 110mm diameter (type 400)
on walls with timber plugs and pvc brackets. (Specials paid m 885.47
separately)
177 H-019 Construction of septic tank for 30 persons. as per detail drawing
No. CPC/CS/11/04/2015/TYPE-ST/02/01 & nr 161,900.25
CPC/CS/11/04/2015TYPE-ST/02/02
178 H-020 Construction of septic tank for 30 persons. as per detail drawing,
extra over for invert depth exceeding up to 1800mm, per each nr 17,365.71
additional 0.3 m.
179 H-021 Construction of septic tank for 50 persons. as per detail drawing
No. CPC/CS/11/04/2015/TYPE-ST/02/01 & nr 202,874.99
CPC/CS/11/04/2015TYPE-ST/02/02
180 H-022 Construction of septic tank for 50 persons. as per detail drawing,
extra over for invert depth exceeding up to 1800mm, per each nr 20,015.90
additional 0.3 m.

Recommended by the Price Comitee - 2018 Page 15


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
181 H-023 Construction of septic tank for 100 persons.as per detail drawing
No. CPC/CS/11/04/2015/TYPE-ST/02/01 & nr 258,564.63
CPC/CS/11/04/2015TYPE-ST/02/02
182 H-024 Construction of septic tank for 100 persons. as per detail
drawing, extra over for invert depth exceeding up to 1800mm, per nr 25,368.24
each additional 0.3 m.

Recommended by the Price Comitee - 2018 Page 16


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
SECTION VIII - ELECTRICAL INSTALLATION
Note,
* All electrical installation shall be done according to the IET
wiring regulations
* All MCCB, RCD,- 17th
MCBEdition - ( BS 7671:
and Isolators 2008
shall be Incorporating
Europian,
Japanese or equivalent.
* All types of fans shall be approved quality and shall have
minimum one year warranty period.
* Ceiling fans shall be complied with the SLS 814 and shall have
cut-off safety switch and safety wire provided to prevent
detachment of fan motor from the rod.
* All types of LED lamp fittings should have minimum two year
warranty period.
* Samples of all materials shall be approved by the engineer, prior
to the installation.
I-A Point wiring through conduits for lamps and fans.
Pendant type lamp point wiring to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
183 I-001 nr 2,100.00
in concealed conduit in wall and above ceiling, to be
supplied and installed in working order.
2 nos. of pendant type lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
184 I-002 PVC insulated PVC sheathed copper cables wired in nr 2,970.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
3 nos. of pendant type lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
185 I-003 PVC insulated PVC sheathed copper cables wired in nr 3,840.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
4 nos. of pendant type lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
186 I-004 PVC insulated PVC sheathed copper cables wired in nr 4,710.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
Recessed type / surface mounted type / ceiling mounted
type lamp point wiring to be carried out with 2 x 1.0 mm2
187 I-005 PVC insulated PVC sheathed copper cables wired in nr 1,839.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
2 nos. of recessed type / surface mounted type / ceiling
mounted type lamp point to be controlled by one switch -
point wirings to be carried out with 2 x 1.0 mm2 PVC
188 I-006 nr 2,448.00
insulated PVC sheathed copper cables wired in concealed
conduit in wall and above ceiling, to be supplied and
installed in working order.

Recommended by the Price Comitee - 2018 Page 17


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
3 nos. of recessed type / surface mounted type / ceiling
mounted type lamp point to be controlled by one switch -
point wirings to be carried out with 2 x 1.0 mm2 PVC
189 I-007 nr 3,057.00
insulated PVC sheathed copper cables wired in concealed
conduit in wall and above ceiling, to be supplied and
installed in working order.
4 nos. of recessed type / surface mounted type / ceiling
mounted type lamp point to be controlled by one switch -
point wirings to be carried out with 2 x 1.0 mm2 PVC
190 I-008 nr 3,666.00
insulated PVC sheathed copper cables wired in concealed
conduit in wall and above ceiling, to be supplied and
installed in working order.
Watertight lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
191 I-009 nr 1,839.00
in concealed conduit in wall and above ceiling, to be
supplied and installed in working order.
2 nos. of watertight lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
192 I-010 PVC insulated PVC sheathed copper cables wired in nr 2,448.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
3 nos. of watertight lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
193 I-011 PVC insulated PVC sheathed copper cables wired in nr 3,057.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order..
4 nos. of watertight lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
194 I-012 PVC insulated PVC sheathed copper cables wired in nr 3,666.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order..
Indoor bracket lamp point wiring to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
195 I-013 nr 1,839.00
in concealed conduit in wall and above ceiling, to be
supplied and installed in working order..
2 nos. of indoor bracket lamp points to be controlled by
one switch - point wirings to be carried out with 2 x 1.0
196 I-014 mm2 PVC insulated PVC sheathed copper cables wired in nr 2,448.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
3 nos. of indoor bracket lamp points to be controlled by
one switch - point wirings to be carried out with 2 x 1.0
197 I-015 mm2 PVC insulated PVC sheathed copper cables wired in nr 3,057.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.

Recommended by the Price Comitee - 2018 Page 18


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Stairway lamp point wiring - to be carried out with 2 x 1.0
mm2 PVC insulated PVC sheathed copper cables wired in
198 I-016 nr 3,161.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
Ceiling fan point wiring completed with fan hook - to be
carried out with 2 x 1.0 mm2 PVC insulated PVC sheathed
199 I-017 copper cables and 2.5 mm2 earth cable wired in concealed nr 2,402.00
conduit in wall and above ceiling, to be supplied and
installed in working order.
Point wiring through conduits for Socket outlets -5A,13A,15A,
I-B
Data & Telephone.
5 A socket outlet - point wiring to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables and
200 I-018 2.5 mm2 earth cable wired in concealed conduit in wall nr 2,360.00
and above ceiling, to be supplied and installed in working
order.
13 A socket outlet / grouped socket outlets - point wiring to
be carried out with 2 x 2.5 mm2 PVC insulated PVC
201 I-019 sheathed copper cables and 2.5 mm2 earth cable wired in nr 3,487.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
13 A socket outlet to be controlled by 20A D/pole switch
with neon indicator - point wiring to be carried out with 2 x
2.5 mm2 PVC insulated PVC sheathed copper cables and
202 I-020 nr 4,278.00
2.5 mm2 earth cable wired in concealed conduit in wall and
above ceiling ,to be supplied and installed in working
order.
15 A socket outlet - point wiring to be carried out with 2 x
2.5 mm2 PVC insulated PVC sheathed copper cables and
203 I-021 2.5 mm2 earth cable wired in concealed conduit in wall and nr 3,487.00
above ceiling , to be supplied and installed in working
order.
15 A socket outlet to be controled by 20A D/pole switch
with neon indicator - point wiring to be carried out with 2 x
2.5 mm2 PVC insulated PVC sheathed copper cables and
204 I-022 nr 4,092.00
2.5 mm2 earth cable wired in concealed conduit in wall and
above ceiling ,to be supplied and installed in working
order.
Data socket outlet ( RJ 45 ) - point wiring to be carried out
with 5U/ UTP AWG 24 CAT 5E PVC cables wired in
205 I-023 nr 1,861.00
concealed conduit in wall and above ceiling, to be supplied
and installed in working order.
Data socket outlet ( RJ 45 ) - point wiring to be carried out
with 6U/ UTP AWG 24 CAT 6E PVC cables wired in
206 I-024 nr 1,970.00
concealed conduit in wall and above ceiling ,to be supplied
and installed in working order.

Recommended by the Price Comitee - 2018 Page 19


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Telephone socket outlet ( RJ 11 ) - point wiring to be
carried out with 2 x 0.5 mm2 Single Pair - BS 10653
207 I-025 nr 1,631.00
cables wired in concealed conduit in wall and above ceiling
,to be supplied and installed in working order.
Telephone socket outlet ( RJ 11 ) - point wiring to be
carried out with 2 x 0.5 mm2 Single Pair - BS 10653
208 I-026 nr 1,849.00
cables wired in concealed conduit in wall and above ceiling
,to be supplied and installed in working order.
I-C Point wiring through PVC casing for lamps and fans.
Pendent type lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables
209 I-027 nr 2,208.00
wired with PVC casing on wall and on soffit of the slabs to
be supplied and installed in working order .
2 nos. of pendent lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
210 I-028 PVC insulated PVC sheathed copper cables wired with nr 3,104.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order .
3 nos. of pendent lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
211 I-029 PVC insulated PVC sheathed copper cables wired with nr 4,041.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order .
4 nos. of pendent lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
212 I-030 PVC insulated PVC sheathed copper cables wired with nr 4,937.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
Recessed type / surface mounted type / ceiling mounted
type lamp point wiring - to be carried out with 2 x 1.0 mm2
213 I-031 PVC insulated PVC sheathed copper cables wired with nr 1,947.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order .
2 nos. of recessed type / surface mounted type / ceiling
mounted type lamp points to be controlled by one switch-
point wirings to be carried out with 2 x 1.0 mm2 PVC
214 I-032 nr 2,582.00
insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in working order .
3 nos. of recessed type / surface mounted type / ceiling
mounted type lamp points to be controlled by one switch-
point wirings to be carried out with 2 x 1.0 mm2 PVC
215 I-033 nr 3,217.00
insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in working order.

Recommended by the Price Comitee - 2018 Page 20


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
4 nos. of recessed type / surface mounted type / ceiling
mounted type lamp points to be controlled by one switch-
point wirings to be carried out with 2 x 1.0 mm2 PVC
216 I-034 nr 3,852.00
insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in working order.
Watertight lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
217 I-035 nr 1,947.00
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
2 nos. of watertight lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
218 I-036 PVC insulated PVC sheathed copper cables wired with nr 2,582.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
3 nos. of watertight lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
219 I-037 PVC insulated PVC sheathed copper cables wired with nr 3,217.00
PVC casing on wall and on soffit to be supplied and
installed in working order.
4 nos. of watertight lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
220 I-038 PVC insulated PVC sheathed copper cables wired with nr 3,852.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
Indoor bracket lamp point wiring - to be carried out with 2
x 1.0 mm2 PVC insulated PVC sheathed copper cables
221 I-039 nr 1,947.00
wired with PVC casing on wall and on soffit of the slabs to
be supplied and installed in working order.
2 nos. of indoor bracket lamp points to be controlled by
one switch - point wirings to be carried out with 2 x 1.0
222 I-040 mm2 PVC insulated PVC sheathed copper cables wired nr 2,582.00
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
3 nos. of indoor bracket lamp points to be controlled by
one switch - point wirings to be carried out with 2 x 1.0
223 I-041 mm2 PVC insulated PVC sheathed copper cables wired nr 3,217.00
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
Stairway lamp point wiring - to be carried out with 2 x 1.0
mm2 PVC insulated PVC sheathed copper cables wired
224 I-042 nr 3,475.00
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.

Recommended by the Price Comitee - 2018 Page 21


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Ceiling fan point wiring completed with fan hook - to be
carried out with 2 x 1.0 mm2 PVC insulated PVC sheathed
225 I-043 copper cables and 2.5 mm2 earth cable wired with PVC nr 2,510.00
casing on wall and on soffit of the slabs to be supplied and
installed in working order.
Point wiring through PVC casing for Socket outlets -
I-D
5A,13A,15A, Data & Telephone.
5 A socket outlet - point wiring to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables and
226 I-044 2.5 mm2 earth cable wired with PVC casing on wall and on nr 2,447.00
soffit of the slabs to be supplied and installed in working
order.
13 A socket outlet / grouped socket outlets - point wiring to
be carried out with 2 x 2.5 mm2 PVC insulated PVC
227 I-045 sheathed copper cables and 2.5 mm2 earth cable wired with nr 3,669.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
13 A socket outlet to be controled by 20A D/pole switch
with neon indicator - point wiring to be carried out with 2 x
2.5 mm2 PVC insulated PVC sheathed copper cables and
228 I-046 nr 4,460.00
2.5 mm2 earth cable wired with PVC casing on wall and on
soffit of the slabs to be supplied and installed in working
order.
15 A socket outlet - point wiring to be carried out with 2 x
2.5 mm2 PVC insulated PVC sheathed copper cables and
229 I-047 2.5 mm2 earth cable wired with PVC casing on wall and on nr 3,669.00
soffit of the slabs to be supplied and installed in working
order.
15 A socket outlet to be controled by 20A D/pole switch
with neon indicator - point wiring to be carried out with 2 x
2.5 mm2 PVC insulated PVC sheathed copper cables and
230 I-048 nr 4,460.00
2.5 mm2 earth cable wired with PVC casing on wall and on
soffit of the slabs to be supplied and installed in working
order.
Data socket outlet ( RJ 45 ) - point wiring to be carried out
with 5U/ UTP AWG 24 CAT 5E PVC cables wired with
231 I-049 nr 2,012.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
Data socket outlet ( RJ 45 ) - point wiring to be carried out
with 6U/ UTP AWG 24 CAT 6E PVC cables wired with
232 I-050 nr 2,122.00
PVC casing on wall and on soffit of the slabs to be
supplied and installed in working order.
Telephone socket outlet ( RJ 11 ) - point wiring to be
carried out with 2 x 0.5 mm2 Single Pair - BS 10653
233 I-051 nr 1,782.00
cables wired with PVC casing on wall and on soffit of the
slabs to be supplied and installed in working order.

Recommended by the Price Comitee - 2018 Page 22


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Telephone socket outlet ( RJ 11 ) - point wiring to be
carried out with 2 x 0.5 mm2 Two Pair - BS 10653 cables
234 I-052 nr 2,000.00
wired with PVC casing on wall and on soffit of the slabs to
be supplied and installed in working order.
I-E Installation of Power cable in Conduits
Supply and installation of 2 x 1 mm2 Cu/PVC/PVC cables
235 I-053 m 154.00
concealed in conduits.
Supply and installation of 2 x 1.5 mm2 Cu/PVC/PVC
236 I-054 m 215.00
cables concealed in conduits.
Supply and installation of 2 x 2.5 mm2 Cu/PVC/PVC
237 I-055 m 296.00
cables concealed in conduits.
Supply and installation of 2 x 4 mm2 Cu/PVC/PVC cables
238 I-056 m 415.00
concealed in conduits.
Supply and installation of 2 x 6 mm2 Cu/ PVC/ PVC
239 I-057 m 557.00
cables concealed in conduits.
Supply and installation of 2 x 10 mm2 Cu/ PVC/ PVC
240 I-058 m 847.00
cables concealed in conduits.
Supply and installation of 2 x 16 mm2 Cu/PVC/PVC
241 I-059 m 1,205.00
cables concealed in conduits.
Supply and installation of 2 x 25 mm2 Cu/PVC/PVC
242 I-060 m 1,770.00
cables concealed in conduits.
Supply and installation of 2 x 1 mm2 Cu/PVC/PVC + 2.5
243 I-061 m 223.00
mm2 E cables concealed in conduits.
Supply and installation of 2 x 1.5 mm2 Cu/PVC/PVC +
244 I-062 m 284.00
2.5 mm2 E cables concealed in conduits.
Supply and installation of 2 x 2.5 mm2 Cu/PVC/PVC +
245 I-063 m 365.00
2.5 mm2 E cables concealed in conduits.
Supply and installation of 2 x 4 mm2 Cu/ PVC/ PVC + 4
246 I-064 m 532.00
mm2 E cables concealed in conduits.
Supply and installation of 2 x 6 mm2 Cu/PVC/PVC + 6
247 I-065 m 766.00
mm2 E cables concealed in conduits.
Supply and installation of 2 x 10 mm2 Cu/PVC/PVC + 10
248 I-066 m 1,160.00
mm2 cables concealed in conduits.
Supply and installation of 2 x 16 mm2 Cu/PVC/PVC +
249 I-067 m 1,667.00
16mm2 E cables concealed in conduits.
Supply and installation of 2 x 25 mm2 Cu/PVC/PVC +
250 I-068 m 2,232.00
16mm2 E cables concealed in conduits.
Supply and installation of 4 x 4 mm2 Cu/PVC/PVC cables
251 I-069 m 767.00
concealed in conduits.
Supply and installation of 4 x 6 mm2 Cu/PVC/PVC cables
252 I-070 m 1,045.00
concealed in conduits.
Supply and installation of 4 x 10 mm2 Cu/PVC/PVC
253 I-071 m 1,563.00
cables concealed in conduits.
Supply and installation of 4 x 16 mm2 Cu/PVC/PVC
254 I-072 m 2,231.00
cables concealed in conduits.

Recommended by the Price Comitee - 2018 Page 23


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of 4 x 25 mm2 Cu/PVC/PVC
255 I-073 m 3,786.00
cables concealed in conduits.
Supply and installation of 4 x 35 mm2 PVC/XLPE/Cu
256 I-074 m 4,585.00
cables concealed in conduits.
Supply and installalation of 4 x 4 mm2 Cu/PVC/PVC + 4
257 I-075 m 957.00
mm2 E cables concealed in conduits.
Supply and installation of 4 x 6 mm2 Cu/PVC/PVC + 6
258 I-076 m 1,275.00
mm2 E cables concealed in conduits.
Supply and installation of 4 x 10 mm2 Cu/PVC/PVC + 10
259 I-077 m 1,960.00
mm2 E cables concealed in conduits.
Supply and installation of 4 x 16 mm2 Cu/PVC/PVC +
260 I-078 m 2,750.00
16mm2 E cables concealed in conduits.
Supply and installation of 4 x 25 mm2 Cu/ PVC/ PVC +
261 I-079 m 3,924.00
16mm2 E cables concealed in conduits.
Supply and installation of 4 x 35 mm2 PVC/XLPE/Cu +
262 I-080 m 5,074.00
16 mm2 E cables concealed in conduits.
I-F Installation of Earth cable in Conduits.
Supply and installation of 2.5 mm2 earth cable concealed
263 I-081 m 172.00
in conduit.
Supply and installation of 4 mm2 earth cable concealed in
264 I-082 m 219.00
conduit.
Supply and installation of 6 mm2 earth cable concealed in
265 I-083 m 273.00
conduit.
Supply and installation of 10 mm2 earth cable concealed in
266 I-084 m 383.00
conduit.
Supply and installation of 16 mm2 earth cable concealed in
267 I-085 m 553.00
conduit.
Supply and installation of 25 mm2 earth cable concealed in
268 I-086 m 860.00
conduit.
Supply and installation of 35 mm2 earth cable concealed in
269 I-087 m 1,076.00
conduit.
I-G Installation of Earth cable in Casing.
Supply and installation of 2 x 1 mm2 Cu/PVC/PVC cables
270 I-088 m 184.00
concealed in casing.
Supply and installation of 2 x 1.5 mm2 Cu/PVC/PVC
271 I-089 m 245.00
cables concealed in casing.
Supply and installation of 2 x 2.5 mm2 Cu/PVC/PVC
272 I-090 m 326.00
cables concealed in casing.
Supply and installation of 2 x 4 mm2 Cu/PVC/PVC cables
273 I-091 m 446.00
concealed in casing.
Supply and installalation of 2 x 6 mm2 Cu/PVC/PVC
274 I-092 m 622.00
cables concealed in casing.
Supply and installation of 2 x 10 mm2 Cu/PVC/PVC
275 I-093 m 872.00
cables concealed in casing.
Supply and installation of 2 x 16 mm2 Cu/PVC/PVC
276 I-094 m 1,221.00
cables concealed in casing.

Recommended by the Price Comitee - 2018 Page 24


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of 2 x 25 mm2 Cu/PVC/PVC
277 I-095 m 1,786.00
cables concealed in casing.
Supply and installation of 2 x 1 mm2 Cu/PVC/PVC + 2.5
278 I-096 m 253.00
mm2 E cables concealed in casing.
Supply and installation of 2 x 1.5 mm2 Cu/PVC/PVC +
279 I-097 m 314.00
2.5 mm2 E cables concealed in casing.
Supply and installation of 2 x 2.5 mm2 Cu/PVC/PVC +
280 I-098 m 395.00
2.5 mm2 E cables concealed in casing.
Supply and installation of 2 x 4 mm2 Cu/PVC/PVC + 2.5
281 I-099 m 562.00
mm2 E cables concealed in casing.
Supply and installation of 2 x 6 mm2 Cu/PVC/PVC + 6
282 I-100 m 792.00
mm2 E cables concealed in casing.
Supply and installation of 2 x 10 mm2 Cu/PVC/PVC + 10
283 I-101 m 1,170.00
mm2 E cables concealed in casing.
Supply and installation of 2 x 16 mm2 Cu/PVC/PVC +
284 I-102 m 1,813.00
16mm2 E cables concealed in casing.
Supply and installation of 2 x 25 mm2 Cu/PVC/PVC +
285 I-103 m 2,379.00
16mm2 E cables concealed in casing.
Supply and installation of 4 x 4 mm2 Cu/PVC/PVC cables
286 I-104 m 833.00
concealed in casing.
Supply and installation of 4 x 6 mm2 Cu/PVC/PVC cables
287 I-105 m 1,089.00
concealed in casing.
Supply and installation of 4 x 10 mm2 Cu/PVC/PVC
288 I-106 m 1,732.00
cables concealed in casing.
Supply and installation of 4 x 16 mm2 Cu/ PVC/ PVC
289 I-107 m 2,372.00
cables concealed in casing.
Supply and installation of 4 x 25 mm2 Cu/PVC/PVC
290 I-108 m 3,458.00
cables concealed in casing.
Supply and installation of 4 x 35 mm2 PVC/XLPE/Cu
291 I-109 m 4,607.00
cables concealed in casing.
Supply and installation of 4 x 4 mm2 Cu/ PVC/ PVC + 4
292 I-110 m 949.00
mm2 E cables concealed in casing.
Supply and installation of 4 x 6 mm2 Cu/ PVC/ PVC + 6
293 I-111 m 1,259.00
mm2 E cables concealed in casing.
Supply and installation of 4 x 10 mm2 Cu/ PVC/ PVC +
294 I-112 m 2,012.00
10 mm2 E cables concealed in casing.
Supply and installation of 4 x 16 mm2 Cu/ PVC/ PVC +
295 I-113 m 2,736.00
16mm2 E cables concealed in casing.
Supply and installation of 4 x 25 mm2 Cu/ PVC/ PVC +
296 I-114 m 3,888.00
16mm2 E cables concealed in casing.
Supply and installation of 4 x 35 mm2 PVC/XLPE/Cu +
297 I-115 m 5,037.00
16 mm2 E cables concealed in casing.
I-H Installation of earth cable in Casing.
Supply and installation of 2.5 mm2 earth cable concealed
298 I-116 m 203.00
in casing.

Recommended by the Price Comitee - 2018 Page 25


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of 4 mm2 earth cable concealed in
299 I-117 m 250.00
casing.
Supply and installation of 6 mm2 earth cable concealed in
300 I-118 m 303.00
casing.
Supply and installation of 10 mm2 earth cable concealed in
301 I-119 m 413.00
casing.
Supply and installation of 16 mm2 earth cable concealed in
302 I-120 m 624.00
casing.
Supply and installation of 25 mm2 earth cable concealed in
303 I-121 m 925.00
casing.
Supply and installation of 35 mm2 earth cable concealed in
304 I-122 m 1,141.00
casing.
Installation of armoured cables ( Underground or on
I-I
trays )
Supply and installation of 4 x 35 mm2
305 I-123 Cu/XLPE/SWA/PVC - armoured cables (Excluding floor m 5,082.00
excavation, civil works or cable tray installations)
Supply and installation of 4 x 25 mm2
306 I-124 Cu/XLPE/SWA/PVC - armoured cables (Excluding floor m 4,064.00
excavation, civil works or cable tray installations)
Supply and installation of 2 x 25 mm2
307 I-125 Cu/XLPE/SWA/PVC - Armoured cables (Excluding floor m 2,957.00
excavation, civil works or cable tray installations)
Supply and installation of 2 x 35mm2
308 I-126 Cu/XLPE/SWA/PVC - armoured cables (Excluding floor m 3,905.00
excavation, civil works or cable tray installations)
Supply and installation of 2 x 4 mm2 Cu/PVC/SWA/PVC -
309 I-127 armoured cables (Excluding floor excavation, civil works m 1,061.00
or cable tray installations)
Supply and installation of 2 x 6 mm2 Cu/PVC/SWA/PVC -
310 I-128 armoured cables (Excluding floor excavation, civil works m 1,272.00
or cable tray installations)
Supply and installation of 2 x 10 mm2 Cu/PVC/SWA/PVC -
311 I-129 armoured cables (Excluding floor excavation, civil works m 1,587.00
or cable tray installations)
Supply and installation of 2 x 16 mm2 Cu/PVC/SWA/PVC
312 I-130 cables (Excluding floor excavation, civil works or cable m 2,219.00
tray installations)
Supply and installation of 4 x 2.5 mm2 Cu/PVC/SWA/PVC
313 I-131 - armoured cables (Excluding floor excavation, civil works m 796.00
or cable tray installations)
Supply and installation of 4 x 4 mm2 Cu/PVC/SWA/PVC -
314 I-132 armoured cables (Excluding floor excavation, civil works m 1,166.00
or cable tray installations)

Recommended by the Price Comitee - 2018 Page 26


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of 4 x 6 mm2 Cu/PVC/SWA/PVC -
315 I-133 armoured cables (Excluding floor excavation, civil works m 1,535.00
or cable tray installations)
Supply and installation of 4 x 10 mm2 Cu/PVC/SWA/PVC -
316 I-134 armoured cables (Excluding floor excavation, civil works m 2,378.00
or cable tray installations)
Supply and installation of 4 x 16 mm2 Cu/PVC/SWA/PVC -
317 I-135 armoured cables (Excluding floor excavation, civil works m 3,115.00
or cable tray installations)
I-J Installation of Lamp fittings
Supply and installation of pendent type 200mm dia. conical
polycarbonate lamp shade and 15W CFL bulb (CFL bulb
318 I-136 nr 4,853.00
shall be 4 stars rated or greater) in working order.

Supply and installation of 15 W CFL globe (CFL bulb


319 I-137 nr 450.00
shall be 4 stars rated or greater) in working order.
Supply and installation of 7 W LED Globe in working
320 I-138 order (Efficacy shall be eaqual or greater than 80 lm / W). nr 514.00

Supply and installation of recessed type 1200mm x


1003mm fluorescent lamp fitting completed with polished
321 I-139 aluminium double parabolic louver and 2 nos. of 36 nr 5,835.00
W,1200mm fluorescent bulbs in working order. (with
electronic ballest)
Supply and installation of recessed type 600mm x 600mm
fluorescent lamp fitting completed with polished
322 I-140 aluminium double parabolic louver and 3 nos. of 18 nr 5,414.00
W,600mm fluorescent bulbs in working order. (With
electronic ballest)
Supply and installation of 1200mm fluorescent lamp fitting
completed with prismatic diffuser and 1 no.. of
323 I-141 nr 2,258.00
36W,1200mm fluorescent bulb in working order. (With
electronic ballest)
Supply and installation of 1200mm fluorescent lamp
fitting completed with prismatic diffuser and 2 nos. of
324 I-142 nr 2,521.00
36W 1200mm fluorescent bulb sin working order. (with
electronic ballest).
Supply and installation of 600mm fluorescent lamp fitting
completed with prismatic diffuser and 1 no.. of 18W
325 I-143 nr 2,258.00
600mm fluorescent bulb in working order. (With
Electronic ballest).
Supply and installation of 600mm fluorescent lamp fitting
completed with Opal white diffuser and 1 no.. of 18w
326 I-144 nr 2,099.00
600mm fluorescent bulb in working order. (With electronic
ballest).

Recommended by the Price Comitee - 2018 Page 27


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of 1200mm fluorescent lamp fitting
completed with opal white diffuser and 1 no.. of
327 I-145 nr 2,627.00
36w,1200mm fluorescent bulb in working order. (With
electronic ballest).
Supply and installation of 1200mm fluorescent lamp fitting
completed with opal white diffuser and 2 nos. of
328 I-146 nr 3,311.00
36w,1200mm fluorescent bulbs in working order.(With
electronic ballest).
Supply and installation of recessed (ceiling mounted) type
down light completed with 5" dia. polish aluminium
329 I-147 nr 1,428.00
reflector and 20W CFL bulb (CFL bulb shall be 4 stars
rated or greater) in working order.
Supply and installation of recessed (ceiling mounted) type
down light completed with 4" dia. polish aluminium
330 I-148 nr 1,296.00
reflector and 15W CFL bulb (CFL bulb shall be 4 stars
rated or greater) in working order.
Supply and installation of cylindrical down light (surface
mounted type) completed with 4" dia. polish aluminium
331 I-149 nr 1,565.56
reflector and 15 W CFL bulb (CFL bulb shall be 4 stars
rated or greater) in working order.
Supply and installation of cylindrical down light (surface
mounted type) completed with 5" dia. polish aluminium
332 I-150 nr 1,759.00
reflector and 20 W CFL bulb (CFL bulb shall be 4 stars
rated or greater) in working order.
Supply and installation of watertight bracket lamp (Bulk
333 I-151 nr 1,512.00
head) with 15 W CFL bulb in working order.
Supply and installation of watertight bracket lamp (Bulk
334 I-152 head) with 20 W CFL bulb (CFL bulb shall be 4 stars rated nr 1,591.00
or greater) in working order.
Supply and installation of 150W Halogen floodlight in
335 I-153 nr 1,460.00
working order.
Supply and installation of 150W Metal Halide compact
336 I-154 flood lamp with IP 65 rating or greater, including diecast nr 6,914.00
metal enclouser and all other required accessories.
Supply and installation of 250W Metal Halide compact
337 I-155 flood lamp with IP 65 rating or greater, including diecast nr 7,967.00
metal enclouser and all other required accessories.
Supply and installation of Cobra head type street lamp
fitting with IP 65 rating or greater, including 150W High
338 I-156 pressure sodium lamp with necessory controle gears, Die- nr 9,088.00
casting aluminum enclouser, Tempered glass cover and all
other required accessories.

Recommended by the Price Comitee - 2018 Page 28


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of Cobra head type street lamp
fitting with IP 65 rating or greater, including 250W High
339 I-157 pressure sodium lamp with necessory controle gears, Die- nr 12,249.00
casting aluminum enclouser, Tempered glass cover and all
other required accessories.
Supply and installation of 10W LED floodlight with IP 65
340 I-158 rating or greater in working order. (shall have minimum nr 2,329.00
two year warranty period).
Supply and installation of 20W LED floodlight with IP 65
341 I-159 rating or greater in working order. (Shall have minimum nr 3,594.00
two year warranty period).
Supply and installation of 30W LED floodlight with IP 65
342 I-160 rating or greater in working order. (Shall have minimum nr 4,701.00
two year warranty period).
Supply and installation of 50W LED floodlight with IP 65
343 I-161 rating or greater in working order. (Shall have minimum nr 6,808.00
two year warranty period).
Supply and installation of 100W LED floodlight with IP 65
344 I-162 rating or greater in working order. (Shall have minimum nr 9,971.00
two year warranty period).
Supply and installation of recessed (ceiling mounted) type
345 I-163 6W LED panel lamp fitting in working order.(Shall have nr 1,138.00
minimum two year warranty period).
Supply and installation of recessed (ceiling mounted) type
346 I-164 12W LED panel lamp fitting in working order.(Shall have nr 1,403.00
minimum two year warranty period).
Supply and installation of recessed (ceiling mounted) type
347 I-165 18W LED panel lamp fitting in working order.(Shall have nr 1,771.00
minimum two year warranty period).
Supply and installation of surface mounted type 6W LED
348 I-166 panel lamp fitting in to working order. (Shall have nr 1,244.00
minimum two year warranty period).
Supply and installation of surface mounted type 12W LED
349 I-167 panel lamp fitting in to working order. (Shall have nr 1,560.00
minimum two year warranty period).
Supply and installation of surface mounted type 18W LED
350 I-168 panel lamp fitting in to working order. (Shall have nr 2,092.00
minimum two year warranty period).
I-K Installation of Fans
Supply and installation of of Japanese or equivalant ceiling
fan 1400mm dia. complete with 5 speed humfree (electrical
351 I-169 switch size 85X85mm) regulator, safety switch and safety nr 9,057.00
wire in working order - Excluding Wiring . (Prime cost -Rs.
6435.00 * Excluding VAT )

Recommended by the Price Comitee - 2018 Page 29


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of of Indian or equivalant ceiling
fan 1400mm dia. complete with 5 speed humfree (electrical
352 I-170 switch size 85X85mm) regulator in working order - nr 6,897.00
Excluding Wiring . (Prime cost -Rs. 4652.00 * Excluding
VAT )
Supply and installation of of 200mm dia. Japanese or
equivalent exhaust fan with auto shutter in working order -
353 I-171 nr 8,750.00
excluding wiring. ( Prime Cost - Rs.6086.00.00 *
Excluding VAT)
Supply and installation of of 200mm dia. Indian or
equivalent exhaust fan with auto shutter in working order -
354 I-172 nr 5,219.00
excluding wiring. ( Prime Cost - Rs.3173.00 * Excluding
VAT)
Supply and installation of of Japanese or equivalent
300mm dia. exhaust fan with auto shutter in working order -
355 I-173 nr 10,543.00
excluding wiring. ( Prime Cost - Rs. 7565.00 * Excluding
VAT)
Supply and installation of of Indian or equivalent 300mm
dia. exhaust fan with auto shutter in working order -
356 I-174 nr 6,431.00
excluding wiring. ( Prime Cost - Rs. 4173.00 * Excluding
VAT)
Supply and installation of of Japanese or equivalent wall
357 I-175 fan with speed regulator in working order- excluding nr 11,744.00
wiring. ( Prime cost- Rs.8913.00 * Excluding VAT)
Supply and installation of of Indian or equivalent wall fan
358 I-176 with speed regulator in working order- excluding wiring. ( nr 6,685.00
Prime cost- Rs.4739.00 * Excluding VAT)
Supply and installation of Japanese or equivalant Orbit fan
359 I-177 in working order -excluding wiring. ( Prime Cost- nr 15,169.00
11739.00* Excluding VAT)
Supply and installation of Indian or equivalant Orbit fan in
360 I-178 working order -excluding wiring. ( Prime Cost- 5434.00* nr 7,528.00
Excluding VAT)
I-L Socket outlets Installation
Supply and installation of of 5 A socket outlet in working
361 I-179 nr 566.00
order .
Supply and installation of of 13 A socket outlet in working
362 I-180 nr 587.00
order .
Supply and installation of of 15 A socket outlet in working
363 I-181 nr 650.00
order.
Supply and installation of of 5 A socket outlet with neon
364 I-182 nr 661.00
indicator in working order.
Supply and installation of of 13 A socket outlet with neon
365 I-183 nr 713.00
indicator in working order.
Supply and installation of of 15 A socket outlet with neon
366 I-184 nr 766.00
indicator in working order.

Recommended by the Price Comitee - 2018 Page 30


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of of 16A / 32A 3 pin industrial
367 I-185 nr 1,363.00
socket outlet in working order.
Supply and installation of of 16A / 32A 5 pin industrial
368 I-186 nr 1,547.00
socket outlet in working order.
Supply and installation of of RJ 45 data socket outlet in
369 I-187 nr 1,873.00
working order.
Supply and installation of of RJ 11 telephone socket outlet
370 I-188 nr 818.00
in working order.
Supply and installation of of socket outlet including data
371 I-189 outlet and telephone outlet on one plate, in working order. nr 2,336.00

I-M Earthing Electrodes


Supply and installation of of 4 feet Cu earth electrode with
372 I-190 16mm diameter and other accessories in working order. nr 1,519.00

Supply and installation of 5 feet GI pipe with 2 inch


373 I-191 diameter as an earth electrode and other accessories in nr 4,144.00
working order.
no.te :- Extra over chamber for earth electrode with 50mm
thick 1:2:4 (20mm) concrete side walls with RCC cover See BSR Item
374
slab on top & Internal dimension 150mm x 150mm x No. C-022
300mm.
32A single Phase Distribution Boards ( Plastic Enclouser)
I-N

Supply and installation of 6 way single phase distribution


375 I-192 board including 32 A 2P Isolator , 40A 2P RCD (30mA) , nr 10,999.00
02 nos. single pole M.C.B s.
Supply and installation of 8 way single phase distribution
376 I-193 board including 32 A 2P Isolator , 40A 2P RCD (30mA) , nr 13,046.00
04 nos. single pole M.C.B s.
Supply and installation of 10 way single phase distribution
377 I-194 board including 32 A 2P Isolator , 40A 2P RCD (30mA) , nr 15,093.00
06 nos. single pole M.C.B s.
Supply and installation of 12 way single phase distribution
378 I-195 board including 32 A 2P Isolator , 40A 2P RCD (30mA) , nr 17,261.00
08 nos. single pole M.C.B s.
Supply and installation of 14 way single phase distribution
379 I-196 board including 32 A 2P Isolator , 40A 2P RCD (30mA) , nr 19,419.00
10 nos. single pole M.C.B s.
Supply and installation of 16 way single phase distribution
380 I-197 board including 32 A 2P Isolator , 40A 2P RCD (30mA) , nr 21,992.00
12 nos. single pole M.C.B s.
Supply and installation of 18 way single phase distribution
381 I-198 board including 32 A 2P Isolator , 40A 2P RCD (30mA) , nr 24,501.00
14 nos. single pole M.C.B s.

Recommended by the Price Comitee - 2018 Page 31


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
63A single Phase Distribution Boards( Plastic Enclouser)
I-O

Supply and installation of 6 way single phase distribution


382 I-199 board including 63 A 2P Isolator , 63A 2P RCD (30mA) , nr 13,835.00
02 nos. single pole M.C.B s.
Supply and installation of 8 way single phase distribution
383 I-200 board including 63 A 2P Isolator , 63A 2P RCD (30mA) , nr 15,882.00
04 nos. single pole M.C.B s.
Supply and installation of 10 way single phase distribution
384 I-201 board including 63 A 2P Isolator , 63A 2P RCD (30mA) , nr 17,929.00
06 nos. single pole M.C.B s.
Supply and installation of 12 way single phase distribution
385 I-202 board including 63 A 2P Isolator , 63A 2P RCD (30mA) , nr 20,097.00
08 nos. single pole M.C.B s.
Supply and installation of 14 way single phase distribution
386 I-203 board including 63 A 2P Isolator , 63 2P RCD (30mA) , 10 nr 22,255.00
nos. single pole M.C.B s.
Supply and installation of 16 way single phase distribution
387 I-204 board including 63 A 2P Isolator , 63A 2P RCD (30mA) , nr 24,828.00
12 nos. single pole M.C.B s.
Supply and installation of 18 way single phase distribution
388 I-205 board including 63 A 2P Isolator , 63A 2P RCD (30mA) , nr 27,325.00
14 nos. single pole M.C.B s.
32A single Phase Distribution Boards ( Metal Enclouser)
I-P

Supply and installation of 6 way single phase powder


coated metal distribution board including 32 A 2P Isolator ,
389 I-206 nr 13,835.00
40A 2P RCD (30mA) , 02 nos. single pole M.C.B s.

Supply and installation of 8 way single phase powder


coated metal distribution board including 32 A 2P Isolator ,
390 I-207 nr 15,882.00
40A 2P RCD (30mA) , 04 nos. single pole M.C.B s.

Supply and installation of 10 way single phase powder


coated metal distribution board including 32 A 2P Isolator ,
391 I-208 nr 18,518.00
40A 2P RCD (30mA) , 06 nos. single pole M.C.B s.

Supply and installation of 12 way single phase powder


coated metal distribution board including 32 A 2P Isolator ,
392 I-209 nr 20,565.00
40A 2P RCD (30mA) , 08 nos. single pole M.C.B s.

Supply and installation of 14 way single phase powder


coated metal distribution board including 32 A 2P Isolator ,
393 I-210 nr 23,614.00
40A 2P RCD (30mA) , 10 nos. single pole M.C.B s.

Recommended by the Price Comitee - 2018 Page 32


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of 16 way single phase powder
coated metal distribution board including 32 A 2P Isolator ,
394 I-211 nr 25,661.00
40A 2P RCD (30mA) , 12 nos. single pole M.C.B s.

Supply and installation of 18 way single phase powder


coated metal distribution board including 32 A 2P Isolator ,
395 I-212 nr 27,768.00
40A 2P RCD (30mA) , 14 nos. single pole M.C.B s.

63A single Phase Distribution Boards (Metal Enclouser)


I-Q

Supply and installation of 6 way single phase powder


coated metal distribution board including 63 A 2P Isolator ,
396 I-213 nr 16,671.00
63A 2P RCD (30mA) , 02 nos. single pole M.C.B s.

Supply and installation of 8 way single phase powder


coated metal distribution board including 63 A 2P Isolator ,
397 I-214 nr 18,718.00
63A 2P RCD (30mA) , 04 nos. single pole M.C.B s.

Supply and installation of 10 way single phase powder


coated metal distribution board including 63 A 2P Isolator ,
398 I-215 nr 21,354.00
63A 2P RCD (30mA) , 06 nos. single pole M.C.B s.

Supply and installation of 12 way single phase powder


coated metal distribution board including 63 A 2P Isolator ,
399 I-216 nr 23,401.00
63A 2P RCD (30mA) , 08 nos. single pole M.C.B s.

Supply and installation of 14 way single phase powder


coated metal distribution board including 63 A 2P Isolator ,
400 I-217 nr 26,450.00
63 2P RCD (30mA) , 10 nos. single pole M.C.B s.

Supply and installation of 16 way single phase powder


coated metal distribution board including 63 A 2P Isolator ,
401 I-218 nr 28,497.00
63A 2P RCD (30mA) , 12 nos. single pole M.C.B s.

Supply and installation of 18 way single phase powder


coated metal distribution board including 63 A 2P Isolator ,
402 I-219 nr 30,592.00
63A 2P RCD (30mA) , 14 nos. single pole M.C.B s.

I-R Three Phase and other Distribution boards


Supply and installation of of 40 A, 2P, Isolator in plastic
403 I-220 nr 3,285.00
enclosure.
Supply and installation of of 63 A, 2P, Isolator in plastic
404 I-221 nr 3,576.00
enclosure.
Supply and installation of of 40 A, 4P, Isolator in plastic
405 I-222 nr 6,702.00
enclosure.

Recommended by the Price Comitee - 2018 Page 33


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply and installation of of 63 A, 4P, Isolator in plastic
406 I-223 nr 7,405.00
enclosure.
Supply and installation of of 100 A, 4P, MCCB in a
407 I-224 nr 22,757.00
surface mounted metal enclosure.
Supply and installation of 28 way (14 x 2) 2 row metal
enclosure including 2 nos. of 40A 2P Isolator,2 nos. of
408 I-225 nr 40,146.00
40A/ 30mA 2P RCD, 20 nos. of 1P MCB and all other
necessary items including internal wiring in working order.
Supply and installation of 28 way (14 x 2) 2 row metal
enclosure including 2 nos. of 63A 2P Isolator, 2 nos. of
409 I-226 nr 45,818.00
63A 30mA 2P RCD, 20 nos. of 1P MCB and all other
necessary items including internal wiring in working order.
Supply and installation of 28 way (14 x 2) 2 row metal
enclosure including 1 no. of 40A 2P Isolator, 1 no. of
410 I-227 nr 30,498.00
40A/ 30mA 2P RCD, 15 nos. of 1P MCB and all other
necessary items including internal wiring in working order.
Supply and installation of 28 way (14 x 2) 2 row metal
enclosure including 1 no. of 63A 2P Isolator, 1 no. of 63A
411 I-228 nr 36,577.00
30mA 2P RCD, 20 nos. of 1P MCB and all other necessary
items including internal wiring in working order.
Supply and installation of 42 way (14 x 3) 3 row metal
enclosure including 1 no. of 40A 3P MCB, 3 nos. of 40A
412 I-229 2P Isolator, 3 nos. of 40A/ 30mA 2P RCD, 18 nos. of 1P nr 51,915.00
MCB and all other necessary items including internal
wiring in working order.
Supply and installation of 42 way (14 x 3) 3 row metal
enclosure including 1 no. of 63A 3P MCB ,3 nos. of 63A
413 I-230 2P Isolator, 3 nos. of 63A 30mA 2P RCD, 18 nos. of 1P nr 62,738.00
MCB and all other necessary items including internal
wiring.
Supply and installation of 56 way (14 x 4) 4 row metal
enclosure including 1 no. of 40A 4P Isolator ,3 nos. of
414 I-231 32A 2P MCB, 3 nos. of 40A/ 30mA 2P RCD, 30 nos. of nr 65,015.00
1P MCB and all other necessary items including internal
wiring.
Supply and installation of 56 way (14 x 4) 4 row metal
enclosure including 1 no. of 63A 4P Isolator, 3 nos. of
415 I-232 63A 2P MCB, 3 nos. of 63A 30mA 2P RCD, 30 nos. of nr 76,323.00
1P MCB and all other necessary items including internal
wiring.
Supply of 1 no. of 1P MCB. (6A,10A,16A,20A,25A,32A)
416 I-233 nr 642.00

Supply of 1 no. of 2P MCB. (6A,10A,16A,20A,25A,32A)


417 I-234 nr 1,660.00
418 I-235 Supply of 1 no. of 63A 2P MCB nr 3,660.00

Recommended by the Price Comitee - 2018 Page 34


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Supply of 1 no. of 3P MCB. (6A,10A,16A,20A,25A,32A).
419 I-236 nr 2,823.00
420 I-237 Supply of 1 no. of 63A 3P MCB. nr 5,296.00
421 I-238 Supply of 1 no. of 40A 2P MCB. nr 1,830.00
422 I-239 Supply 1 no. of 3P MCB 40A . nr 2,981.00
I-S Installation of MCB type change over
Supply and installation of 40A 2P MCB type changeover
423 I-240 nr 3,069.00
in powder coated metal enclouser in working order.
Supply and installation of 63A 2P MCB type changeover
424 I-241 nr 3,680.00
in powder coated metal enclouser in working order.
Supply and installation of 40A 4P MCB type changeover
425 I-242 nr 6,427.00
in powder coated metal enclouser in working order.
Supply and installation of 63A 4P MCB type changeover
426 I-243 nr 8,007.00
in powder coated metal enclouser in working order.
I-T Installation of Surge Protector.
Supply and installation of 10kA , 385V, 2P surge protector
and 2 nos. of 32A 10kA 1P MCB in a 300X300X150mm
427 I-244 nr 15,944.00
metal enclouser and completed with internal wiring in
working order.
Supply and installation of 10kA, 385V, 4P surge protector
and 4 nos. of 32A 10kA 1P MCB in a 300X300X150mm
428 I-245 nr 27,736.00
metal enclouser and completed with internal wiring in
working order.
I-U Installation of Air Conditioners
Supply and installation of 12000BTU split type air
429 I-246 nr 94,851.00
conditioner unit in working order.
Supply and installation of 12000BTU split type air
430 I-247 nr 98,013.00
conditioner(inverter type) unit in working order.
Supply and installation of 18000BTU split type air
431 I-248 nr 114,874.00
conditioner unit in working order.
Supply and installation of 18000BTU split type air
432 I-249 nr 118,037.00
conditioner(inverter type) unit in working order.
Supply and installation of 24000BTU split type air
433 I-250 nr 133,635.00
conditioner unit in working order.
Supply and installation of 24000BTU split type air
434 I-251 nr 141,223.00
conditioner(inverter type) unit in working order.
Supply and installation of 36000BTU split type air
435 I-252 nr 202,350.00
conditioner unit in working order.

Recommended by the Price Comitee - 2018 Page 35


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
SECTION IX - CARPENTER AND JOINER
436 J-001 Supplying & fixing brass barrel bolts 100mm with brass screws.
nr 386.64
437 J-002 Supplying & fixing oxidized iron barrel bolts 100mm with iron
nr 272.71
screws.
438 J-003 Supplying & fixing brass barrel bolts 150mm with brass screws.
nr 545.41
439 J-004 Supplying & fixing oxidized iron barrel bolts 150mm with iron
nr 301.80
screws.
440 J-005 Supplying & fixing butt hinges brass 100mm x 62mm with brass
Pair 1,047.70
screws.
441 J-006 Supplying & fixing butt hinges oxidized iron 100mm x 62mm
Pair 645.31
with iron screws.
442 J-007 Supplying & fixing casement stays 250mm iron oxidized. nr 260.10
443 J-008 Supplying & fixing casement stays 300mm brass ,circular type
nr 569.16
with brass screws.
444 J-009 Supply and fixing Zn/Al powder coated roller door consisting
0.6mmthick zink aluminium Powder coated sheet, pulleys, side
plate with the racers and necessary U channels. All complete to m2 7,722.00
working order. Excluding the covering box and electrical motor.

445 J-010 Fabricating & fixing door 28mm thick, battened sash with 95mm
x 45mm (Nominal) frame, in cl.1 timber, oxidized heavy duty
furniture 100mm x 62mm iron butt hinges with in side and out
side 100mm barrel bolts , draw ring, painted sashes and frame, m2 16,114.61
two of coats enamel paint with primer under coats.(3Nos
hingers)
446 J-011 Fabricating & fixing door 28mm thick battened, sash single hung
with 95mm x 45mm (Nominal) frame with, Jack timber, oxidized
heavy duty furniture with 2 nos 100mm barrel bolt, rate included m2 19,306.09
primer under coats and two coats of enamel paint.(3Nos of
hingers)
447 J-012 Fabricating & fixing door 28mm thick flush panelled sash single
hung with 95mm x 70mm(Nominal) frame, in treated kempas
timber, oxidized heavy duty furniture, original mortise door lock
approved by engineer,100mm barrel bolts 2 nos etc. rate included m2 23,955.42
primer under coat & two coats of enamel paint .(3Nos of
hingers)
448 J-013 Fabricating & fixing door 28mm thick flush panelled sash single
hung with 95mm x 70mm (Nominal) frame, Jack timber, oxidized
heavy duty furniture, original mortise door lock approved by
engineer, 100mm barrel bolts 2 nos etc.rate included primer m2 26,796.35
under coat & two coats of enamel paint .(3Nos of hingers)

Recommended by the Price Comitee - 2018 Page 36


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
449 J-014 Fabricating & fixing door 28mm thick panelled & glazed double
hung sashes and top fanlight 95mm x 70mm (Nominal)
frame,treated kempas timber, oxidized heavy duty furniture,
original mortise door lock approved by engineer,2 Nos of 100mm m2 21,752.01
barrel bolt and150mm barrel bolt , rate included primer under
coat & two coats of enamel paint.(3pairs of hingers)

450 J-015 Fabricating & fixing door 28mm thick panelled & glazed double
hung sashes and top fanlight 95mm x 70mm (Nominal) frame, in
Jack/special timber, oxidized heavy duty furniture, original
mortise door lock approved by engineer, 100mm barrel bolt & m2 23,591.57
150mm barrel bolt, rate included primer under coat & two coats
of enamel paint.(3pairs of hingers)
451 J-016 Fabricating & fixing door 28mm thick flush panelled, sash with
95mm x 45mm (Nominal) frame, in cl.1 timber, oxidized heavy
duty furniture with inside and out side 100mm barrel bolts in lieu m2 20,391.10
of lock and rate included primer under coat & two coats of
enamel paint.(3Nos of hingers)
452 J-017 Fabricating & fixing door 28mm thick flush panelled, with 95mm
x 45mm (Nominal) frame, in Jack/special timber, oxidized heavy
duty furniture with inside and outside 100mm bolts in lieu of m2 21,653.70
lock and rate included primer under coat & two coats of enamel
paint. (3Nos of hingers)
453 J-018 Fabricating & fixing door 28mm thick plywood sash with 95mm
x 70mm (Nominal) treated kempas timber frame, oxidized heavy
duty furniture, original mortise door lock approved by engineer, 2
m 13,598.72
rate included primer under coat & two coats of enamel
paint.(3Nos of hingers)
454 J-019 Fabricating & fixing door 28mm thick plywood sash with 95mm
x 70mm (Nominal) special timber frame, oxidized heavy duty
furniture,original mortise door lock approved by engineer, rate m2 15,575.99
included primer under coat & two coats of enamel paint.(3Nos of
hingers)
455 J-020 Repairing and re-fixing of door and window frames ,timber if
nr 432.00
used measured separately.
456 J-021 Repairing and re-fixing of door or window sash (timber, except
beadings if used measured separately). m2 2,347.83
457 J-022 Supplying and fixing draw rings 40mm . nr 250.90
458 J-023 Supplying & fixing glass panes 3mm thick, clear/pinhead, rate 2
m 2,183.84
includes for necessary beadings etc.
459 J-024 Supplying & fixing glass panes 4.6mm clear / pinhead ,rate 2
m 2,719.27
includes for necessary beadings etc.
460 J-025 Supplying & fixing hasp & staple 100mm to 150mm.( Pad lock
nr 466.64
Measured seperatly)
461 J-026 Supplying & fixing lock rim or night latch (Chinese) . nr 1,678.68
462 J-027 Supplying & fixing single hung mortise type door lock approved
nr 5,863.14
by engineer.

Recommended by the Price Comitee - 2018 Page 37


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
463 J-028 Supplying & fixing double hung mortise type door lock
nr 9,165.84
approved by engineer.
464 J-029 Fabricating & fixing security weld mesh door sash with locking
divice, in GI weld mesh 50mm x 50mm SWG 10, welded on
40mm x 40mm x 5mm MS angle frame complete with application
of two coats enamel paint over two coats of anticorrosive paint m2 11,294.71
complete .as per detail drawing No. CPC/CS/11/04/2017/TYPE-
ST/06
465 J-030 Fabricating & fixing security weld mesh in open type buildings in
GI weld mesh 50mm x 50mm SWG 10, welded on 40mm x
40mm x 5mm angle frame complete with application of two
coats enamel paint over two coats of anticorrosive paint m2 7,093.50
complete .as per detail drawing No. CPC/CS/11/04/2017/TYPE-
ST/07
466 J-031 Fabricating & fixing Special security grill fixed to aluminium
windows complete.(in 16mm x 5mm flat iron frame & SWG 10,
50mm x50mm weld mesh complete with application of two coats m2 10,215.43
enamel paint over two coats of anticorrosive paint.) as per detail
drawing No. CPC/CS/11/04/2017/TYPE-ST/08
467 J-032 Deleted
468 J-033 Fabricating & fixing Special security grill fixed for windows
complete with perimeter & either side of middle opening frame
in 16mm x 5mm M.S flat & 6mm dia.MS bars at 100mm c/c
diagonally ,properly welded & fixed to walls with rawl plugs,
screws inclusive of two coats of enamel paint on two coats of m2 8,717.48
anticorrosive paint.as per detail drawing No.
CPC/CS/11/04/2017/TYPE-ST/09

469 J-034 Repairing door & window frames using treated kempas, 95mm x
m 1,352.23
45mm (Nominal).
470 J-035 Repairing door & window frames using treated kempas, 95mm
m 1,871.37
x 70mm (Nominal).
471 J-036 Repairing door & window frames using Jack timber 95mm x
m 1,858.61
45mm (Nominal).
472 J-037 Repairing door & window frames using Jack timber 95mm x
m 2,529.39
70mm (Nominal).
473 J-038 Repairing door sash using Class 1 timber up to 28mm thick
nr 6,559.67
planks. ( Up to 2.0m2)
474 J-039 Repairing door sash using special class timber up to 28mm thick
nr 6,712.02
planks. ( Up to 2.0m2)
475 J-040 Repairing glazed / panelled window sash using class 1 timber up
nr 3,833.34
to 28mm thick planks. ( Up to 1.2m2)
476 J-041 Repairing glazed / panelled window sash using special class
nr 3,909.51
timber up to 28mm thick planks. ( Up to 1.2m2)

Recommended by the Price Comitee - 2018 Page 38


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
477 J-042 Fabricating and fixing fully glazed window 28mm thick sashes
and frame with nominal size 95mmx70mm using treated kempas
timber complete with oxidized heavy-duty furniture,3.0mm clear / 2
m 22,447.28
pinhead glass, including two coats of enamel paint & primer
under coat.
478 J-043 Fabricating and fixing fully glazed window 28mm thick sashes
and 95mm x 70mm (Nominal) frame using Jack timber complete
with oxidized heavy duty furniture, including two coats of enamel m2 22,469.95
paint & primer under coat. (Glass thickness 3.0mm clear /
pinhead).
479 J-044 Supplying & fixing casement fasteners Iron oxidized . nr 218.17
480 J-045 Supplying & fixing door, window frames new, measured length
of timber using treated kempas, 95mm x 45mm (Nominal). m 1,122.20

481 J-046 Supplying & fixing door, window frames new, measured length
m 1,616.63
of timber using treated kempas, 95mm x 70mm (Nominal)..
482 J-047 Supplying & fixing door/ window frames with new jack timber
m 1,580.78
95mm x 45mm (Nominal)..
483 J-048 Supplying & fixing door/ window frames with new jack timber
m 2,243.31
95mm x 70mm (Nominal)..
484 J-049 Supplying & fixing door, window 28mm thick new sash glazed or
panelled class1 timber. m2 10,277.15
485 J-050 Supplying & fixing door, window 28mm thick sash new glazed or
panelled Jack or special. m2 11,065.72
486 J-051 Replacing glass panes plain / pinhead 3mm in complete. m2 2,434.13
487 J-052 Replacing glass panes plain / pinhead 4.6mm in complete. m2
2,969.57
488 J-053 Fabricating and fixing Security weld mesh in open type buildings
in GI weld mesh 50mm x 50mm SWG 10, welded on 40mm x
40mm x 5mm MS angle frame complete with application of two m2 3,860.28
coats enamel paint over two coats of anticorrosive paint (using
available weld mesh ).
489 J-054 Fabricating and fixing security weld mesh on existing window
frames complete with class 1 timber beadings, and applying two
coats paint to match the exiting including two coats of enamel m2 1,785.91
paint & primer under coat.
490 J-055 Supplying and fixing plywood door sash approved quality
2
including of oxidized heavy duty furniture etc. (Painting & locks m 3,510.09
measured separately).
491 J-056 Fabricating and fixing Anodized aluminium louvers panel fixed
to aluminium window or doors with aluminium architectural
sections with 10 - 15 micron coating including all necessary
fitting etc.(Aluminium window or door measured m2 18,620.83
separately).(The used sections are DG01, DG101, A -110 -AT)

Recommended by the Price Comitee - 2018 Page 39


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
492 J-057 Fabricating and fixing Anodized aluminium hinged type sash
door with aluminium architectural sections with 10 - 15 micron
coating glazed and panelled with 3mm plastic coated ply board to
both sides at bottom and 4.6mm thick glass at top.Including door m2 18,862.04
lock etc.(The used sections are 100D 3105, 100D 103, 100D 101,
100D 201, 100D 301, 100D 401, 100D 501, 70SM 1011)

493 J-058 Fabricating and fixing Anodized Aluminium hinged type sash
door with aluminium architectural sections with 10 - 15 micron
coating glazed and panelled with 4mm cladding board at bottom
and 4.6mm thick glass at top.including door lock etc.(The used m
2
21,457.20
sections are -100D 3105, 100D 103, 100D 101, 100D 201,
100D301, 100D 401, 100D 501, 70SM 1011)

494 J-059 Fabricating and fixing Anodized Aluminium hinged type sash
door with aluminium architectural sections with 10 - 15 micron
coating glazed and panelled with 4mm cladding board .including
door lock etc.(The used sections are -100D 3105, 100D 103, m2 22,216.65
100D 101, 100D 201, 100D301, 100D 401, 100D 501, 70SM
1011)
495 J-060 Fabricating and fixing Anodized aluminium glazed window with
openable sash with aluminium architectural sections with 10 - 15
micron coating glazed 4.6 mm thick glass including all necessary m2 13,351.32
rubber beading, rawl plug etc.(The used sections are CA 1009,
CA 1010, CA 2005, 70SM 1011)
496 J-061 Fabricating and fixing Anodized Aluminium glazed fanlight with
openable sash with aluminium architectural sections with 10 - 15
micron coating glazed 4.6 mm thick glass including all necessary m2 17,655.26
rubber beading, rawl plug etc.(The Used sections are -CA-1009,
CA 1010, CA 2005, 70SM 1011)
497 J-062 Fabricating and fixing Anodized aluminium sliding window with
aluminium architectural sections with 10 - 15 micron coating
glazed with 4.6mm thick glass including all necessary rubber 2
beading, rawl plug etc.(The used sections are 70S 1001, 70S m 9,910.03
1101 -1, 70S 1201 - 1, 70S 1401, 70S 1501, 70S 1601, 70S
1701)
498 J-063 Fabricating and fixing TYPE-01 Anodized Aluminium partition
with aluminium architectural sections with 10 - 15 micron coating
glazed and panelled with 3mm , plastic coated ply board to both
sides,at bottom and 4.6mm thick glass at top.(The used section m2 5,552.10
SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

499 J-064 Fabricating and fixing TYPE-02 Anodized Aluminium partition


with aluminium architectural sections with 10 - 15 micron coating
glazed and panelled with 3mm , plastic coated ply board to both
sides,at bottom and 4.6mm thick glass at top.(The used section m2 5,944.37
SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

Recommended by the Price Comitee - 2018 Page 40


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
500 J-065 Fabricating and fixing TYPE -03 Anodized Aluminium partition
with aluminium architectural sections with 10 - 15 micron coating
glazed and panelled with 3mm , plastic coated ply board to both 2
sides,at bottom and 4.6mm thick glass at top.(The used section m 6,136.76
SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

501 J-066 Fabricating and fixing TYPE -04 Anodized Aluminium partition
with aluminium architectural sections with 10 - 15 micron coating
glazed and panelled with 3mm , plastic coated ply board to both
sides,at bottom and 4.6mm thick glass at top.(The used section m2 7,821.85
SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

502 J-067 Fabricating and fixing Anodized aluminium glazed sliding type
door sash with aluminium architectural sections with 10 - 15
micron coating glazed and panelled with 3mm plastic coating ply
board to both sides,at bottom and 4.6mm thick glass at top m2 8,850.95
,including door lock.(The used section 70S - 1002 -1, 70S 1102 -
1, 70S 1701 A, 70S 1402-1, 70S - 1801, 70S 1501, 70S 1202 - 1)

503 J-068 Fabricating and fixing Powder coated aluminium louvers panel
fixed to aluminium window or doors with aluminium
architectural sections with 60-80 micron coating including all
necessary fittings etc.(Aluminium window or door measured m2 21,077.98
separately).(The used sections are DG01, DG101, A -110 -AT)

504 J-069 Fabricating and fixing Powder coated aluminium hinged type
sash door with aluminium architectural sections with 60 - 80
micron coating glazed and panelled with 3mm plastic coated ply
board to both sides at bottom and 4.6mm thick glass at m2 20,524.40
top.Including door lock etc.(The used sections are 100D 3105,
100D 103, 100D 101,100D 201, 100D 301, 100D 401, 100D
501,70SM 1011)
505 J-070 Fabricating and fixing Powder coated aluminium hinged type
sash door with aluminium architectural sections with 60-80
micron coating glazed and panelled with 4mm cladding board at
bottom and 4.6mm thick glass at top.including door lock etc.(The m2 23,119.56
used sections are -100D 3105, 100D 103, 100D 101, 100D 201,
100D301, 100D 401, 100D 501, 70SM 1011)

506 J-071 Fabricating and fixing Powder coated aluminium hinged type
sash door with aluminium architectural sections with 60-80
micron coating glazed and panelled with 4mm cladding board 2
including door lock etc.(The used sections are -100D 3105, 100D m 23,879.01
103, 100D 101, 100D 201, 100D301, 100D 401, 100D 501,
70SM 1011)

Recommended by the Price Comitee - 2018 Page 41


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
507 J-072 Fabricating and fixing Powder coated aluminium glazed window
with openable sash with aluminium architectural sections with 60 -
2
80 micron coating with 4.6 mm thick glass including all necessary m 14,445.16
rubber beading, rawl plug etc.(The used sections are CA 1009,
CA 1010, CA 2005,70SM 1011)
508 J-073 Fabricating and fixing Powder coated aluminium glazed fanlight
with openable sash with aluminium architectural sections with 10 -
15 micron coating glazed 4.6 mm thick glass including all m2 19,195.74
necessary rubber beading, rawl plug etc.(The Used sections are -
CA-1009, CA 1010, CA 2005, 70SM 1011)
509 J-074 Fabricating and fixing Powder coated aluminium glazed sliding
window with aluminium architectural sections with 60 - 80
micron coating with 4.6mm thick glass including all necessary 2
rubber beading, rawl plug & window lock etc.(The used sections m 10,811.07
are 70S 1001, 70S 1101 -1, 70S 1201 - 1, 70S 1401,70S 1501,
70S 1601, 70S 1701)
510 J-075 Fabricating and fixing TYPE-01 Powder coated aluminium
partition with aluminium architectural sections with 60 - 80
micron coating glazed and panelled with 3mm , plastic coated ply
board to both sides, at bottom and 4.6mm thick glass at top.(The m2 5,941.34
used section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

511 J-076 Fabricating and fixing TYPE-02 Powder coated aluminium


partition with aluminium architectural sections with 60 - 80
micron coating glazed and panelled with 3mm , plastic coated ply
board to both sides, at bottom and 4.6mm thick glass at top.(The m2 6,376.03
used section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

512 J-077 Fabricating and fixing TYPE -03 Powder coated aluminium
partition with aluminium architectural sections with 60 - 80
micron coating glazed and panelled with 3mm , plastic coated ply
board to both sides,at bottom and 4.6mm thick glass at top.(The m2 6,604.94
used section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

513 J-078 Fabricating and fixing TYPE -04 Powder coated aluminium
partition with aluminium architectural sections with 60 - 80
micron coating glazed and panelled with 3mm , plastic coated ply
board to both sides, at bottom and 4.6mm thick glass at top.(The m2 8,364.82
used section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

514 J-079 Fabricating and fixing Powder coated aluminium glazed sliding
type door sash with aluminium architectural sections with 60 - 80
micron coating glazed and panelled with 3mm plastic coating ply
board to both sides,at bottom and 4.6mm thick glass at top, m
2
9,581.43
including door lock.(The used section 70S - 1002 -1, 70S 1102 -
1, 70S 1701 A, 70S 1402-1, 70S - 1801, 70S 1501, 70S 1202 - 1)

Recommended by the Price Comitee - 2018 Page 42


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION X - PAINTER AND DECORATOR

515 P-001 Preparing and applying one coat of alkali resisting primer and
two coats of emulsion paint to walls. m2 661.30
516 P-002 After cleaning and preparing surface and applying one coat of 2
m 159.87
emulsion paint.
517 P-003 After cleaning and preparing surface and applying two coats of
emulsion paint. m2 391.71
518 P-004 After cleaning and preparing surface in new wood work
2
(inclusive of one coat of primer), two coats of enamel paint. m 727.43

519 P-005 After cleaning and preparing surface and applying one coat of 2
m 300.49
enamel paint.
520 P-006 After cleaning and preparing surface and applying one coat of
floor paint. m2 326.81
521 P-007 After cleaning and preparing surface and applying two coats of
enamel paint . m2 941.02
522 P-008 After cleaning and preparing surface and applying two coat of
floor paint. m2 739.24
523 P-009 Paint removing from any surfaces with blow lamp. m2 317.76
524 P-010 After removing scales and wire brushing,and applying one coat of
anticorrosive paint on steel work. m2 321.88
525 P-011 After removing scales and wire brushing, and applying two coat
of anticorrosive paint on steel work. m2 683.19
526 P-012 After sand papering and cleaning surface and applying two coats
of polyurethane varnish. m2 502.32
527 P-013 After sand papering and cleaning and applying one coat of
polyurethane varnish for old wooden surfaces. m2 378.61
528 P-014 After cleaning and preparing on external surfaces and applying
one coat of exterior paint. m2 207.46
529 P-015 After cleaning and preparing on external surfaces and applying
two coat of exterior paint. m2 391.43
530 P-016 Applying one coat of primer and two coats of exterior paint for
new walls. m2 497.23
531 P-017 Applying one coat of white or colour washing to walls. m
2
19.36
532 P-018 After patching up and preparing surface applying one coat of
white or colour washing to walls . m2 72.65
533 P-019 After scraping to original plaster and patching up applying two
coats of white or colour washing to walls. m2 142.93
534 P-020 Applying one coat of white washing to ceilings and soffit . m
2
84.75
535 P-021 Applying two coats of white washing to ceilings and soffit .
m2 150.48
536 P-022 After cleaning applying two coats of roofing paint on roof. m
2
329.10
537 P-023 Preparing and applying two coats of skim coat compound on
2
walls or soffit. Finished smooth. (Prepairing surface for painting) m 440.06

Recommended by the Price Comitee - 2018 Page 43


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION XI - ROOFER

538 R-001 Supplying and fixing new asbestos roofing sheets confirming to
SLS 9 on existing framework with new nut and bolts, apply two
coats of emulsion paint under side of sheet etc.(Frame work m2 1,303.47
measured separately).
539 R-002 Replacing Asbestos roofing sheets with new sheets on existing
frame work.with new nut and bolts, apply two coats of emulsion m2 1,392.17
paint under side of sheet etc.
540 R-003 Supplying & fixing 0.47mm thick colour Zn/Al. roofing sheets
with self drilling screws (fasteners) on existing frame work m2 2,100.93
(Frame work measured separately).
541 R-004 Supplying & Fixing 0.47mm thick Zn / Al sheets with self
drilling Screws (Fasteners) on existing frame work (Frame Work
Measured Seperatly) Tile profile. (Single & Double roof) m2 2,303.97

542 R-005 Supplying & Fixing 0.47mm thick Zn / Al sheets with self
drilling Screws (Fasteners) on existing frame work (Frame Work m2 2,366.02
Measured Seperatly) Tile profile. (Hip roof)
543 R-006 Supplying & fixing C - purlin 100 mmx 50 mmx 12 mm, 2mm
thick mild steel including prepare & apply 2 coats of
m 1,825.93
anticorrosive paint, necessary nut & bolts 6mm thick cleat and
welding works etc.
544 R-007 Supplying & Fixing C- purlin 100 mmx 50 mmx 12 mm & 2mm
thick GI including prepar & necessary nut & Bolts 6mm thick m 1,701.89
cleat & Welding Works etc.
545 R-008 Supplying & Fixing C- purlin 150 mmx 65 mmx 14 mm & 2mm
black steel thick including prepar & Apply 2 Coats of
m 2,542.30
Anticorrosive paint, necessary nut & Bolts 6mm thick cleat &
Welding Works etc.
546 R-009 Supplying & Fixing C- purlin 150 mmx 65 mmx 14 mm & 2mm
thick GI including prepar & necessary nut & Bolts 6mm thick m 1,991.42
cleat & Welding Works etc.
547 R-010 Supplying & fixing 0.47mm thick colour Zn /Al. ridge cap/
bottom ridge cap with self drilling screws (Fasteners) minimum m 1,571.14
girth 470mm.
548 R-011 Supplying & fixing 0.47mm thick colour Zn /Al. barge capping
m 1,593.81
with self drilling screws (Fasteners) .
549 R-012 Supplying & fixing 0.47mm thick colour Zn /Al. edge capping
m 1,239.88
with self drilling screws (Fasteners) .
550 R-013 Supplying & Fixing 0.47mm thick Zn / Al Flashing with self
drilling Screws (Fasteners) & rawl plugs. nominal girth 470mm . m 1,621.68

Recommended by the Price Comitee - 2018 Page 44


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
551 R-014 Supplying & Fixing 30mm thick sandwitch pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) Single & Double roof. (Sheet 2
m 5,154.99
thickness top - 0.4mm bottom - 0.35mm)

552 R-015 Supplying & Fixing 40mm thick sandwitch pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) Single & Double roof. (Sheet m2 5,738.91
thickness top - 0.4mm bottom - 0.35mm)

553 R-016 Supplying & Fixing 50mm thick sanwich pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) Single & Double roof. (Sheet 2
m 6,273.83
thickness top - 0.4mm bottom - 0.35mm)

554 R-017 Supplying & Fixing 60mm thick sandwitch pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) Single & Double roof. (Sheet m2 6,696.72
thickness top - 0.4mm bottom - 0.35mm)

555 R-018 Supplying & Fixing 30mm thick sandwitch pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) hip roof. (Sheet thickness top - m2 5,302.56
0.4mm bottom - 0.35mm)
556 R-019 Supplying & Fixing 40mm thick sandwitch pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) hip roof. (Sheet thickness top - m2 5,904.01
0.4mm bottom - 0.35mm)
557 R-020 Supplying & Fixing 50mm thick sandwitch pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) hip roof. (Sheet thickness top - m2 6,454.97
0.4mm bottom - 0.35mm)
558 R-021 Supplying & Fixing 60mm thick sandwitch pannel roofing sheets
with self drilling Screws (Fasteners) on existing frame work
(Frame Work Measured Seperatly) hip roof. (Sheet thickness top - m2 6,890.55
0.4mm bottom - 0.35mm)
559 R-022 Fixing 19mm thick Lunumidella tongued and grooved Ceiling ,
2
under side of rafters, on existing timber frame work. m 2,113.20

560 R-023 Flat asbestos ceiling fixed with wire nails to 100mm x 50mm
joists at 1.2m c/c & 50mm x 50mm bearers @ 0.6m c/c in cl.1
timber including 35mm x 12mm beadings and 50mm x 35mm
cove mouldings of approved timber. Rate included one coat of m2 4,184.91
primer, two coats of emulsion paint to underside of ceiling and
two coats of wood preservative(stain) to timber frame work.

Recommended by the Price Comitee - 2018 Page 45


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
561 R-024 Flat asbestos ceiling fixed with wire nails to 100mm x 50mm
joists,1.2m c/c & 50mm x 50mm bearers at 0.6m c/c in cl. 1
timber including 35mm x 12mm beadings and 50mm x 35mm 2
cove mouldings of approved timber. Rate included two coats of m 3,516.75
wood preservative (stain) on timber frame work.

562 R-025 Fixing flat asbestos ceiling under side of rafters, timber frame
work measured separately, rate included for wire nails, screws, m2 2,392.17
beadings and mouldings.
563 R-026 Fixing flat asbestos ceiling under side of steel purlins ,50mm x
50mm class 1 timber frame not more than 1.2m x 0.6m
crs.includes for wire nails, screws, beadings and mouldings and
6mm dia. mild steel hanging hooks. Rate included for application m2 1,792.31
of wood preservative (stain)timber frame.

564 R-027 Flat Lunumidella tongued and grooved Ceiling 19mm thick
complete with timber frame cl.1 100mm x 50mm joists at 0.6m
crs. Rate included for application of wood preservative on timber m2 4,597.23
frame work twice. (Painting measured separately).

565 R-028 Supplying and fixing down pipes pvc 90mm dia. with brackets
not exceeding 1.2m well secured to walls with plastic rawl plugs. m 611.33
(Rate includes for specials).
566 R-029 Fabricating and fixing GI down pipes G24, 100mm x 75mm
with 20mm x 3mm hoop iron brackets not exceeding 1.2m crs.
m 1,679.68
all other sides and brackets applied with 2 coats anticorrosive
paint, rate includes for specials.
567 R-030 Supplying and fixing down pipes colour Zn/Al 0.47mm thick
100mm X 100mm with brackets not exceeding 1.2m crs. of the m 1,361.35
pipe, rate includes for specials.
568 R-031 Fabricating and fixing GI Gutters G22, 150mm with 12mm x
6mm flat iron brackets not exceeding 0.6m crs. all sides and
m 1,905.97
brackets applied with two coats of anticorrosive paint, rate
includes for specials.
569 R-032 Supplying and fixing Gutters 0.47mm thick colour Zn /Al 457mm
girth with brackets not exceeding 0.6m crs. rate includes for m 1,347.24
specials.
570 R-033 Supplying and fixing pvc gutters square type 150mm with PVC
brackets not exceeding 225mm fixed to valance board using m 952.11
20mm nails, rate includes for specials.
571 R-034 Forming Plaster bands in 1:1:5 cement, lime and sand to tiled
m 71.82
roof coloured to match tiles.
572 R-035 Fixing close fitting type asbestos ridging pairs with necessary
m 1,112.65
bolts.
573 R-036 Laying calicut pattern ridge tile bedded in cement, lime and sand
m 530.77
motar 1:1:4 coloured to match tiles.

Recommended by the Price Comitee - 2018 Page 46


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
574 R-037 Fabricating and fixing Steel sections 2/ 62mm x 62mm x 6mm
used in gable rafters purlins etc.complete with fixing, bolts, 2
m 3,534.88
coats of anticorrosive paint and providing cleats where necessary
.(Concrete pad paid separately)
575 R-038 Applying one coat of wood preservative (stain) on roof structure
in asbestos roof measured in plan area. m2 107.74
576 R-039 Applying one coat of wood preservative (stain) on roof structure
for calicut tile roof, measured in plan area. m2 140.61
577 R-040 Applying one coat of wood preservative (stain) on roof structure
for asbestos roof measured in plan area. m2 167.09
578 R-041 Applying one coat of wood preservative (stain) on roof structure
for calicut tile roof measured in plan area. m2 271.58
579 R-042 Laying calicut tiles (available) on roof (For scattered laying) up
nr 9.60
to 10 tiles per building only.
580 R-043 Supplying and laying of new calicut tiles ( scattered laying where
nr 94.82
necessary) up to 25 tiles per building only.
581 R-044 Shifting and re-laying after cleaning calicut tiles. (For
nr 38.40
measurements of area not exceeding 25 tiles).
582 R-045 Supplying and laying, calicut pattern tiles, in any building. m2 1,257.80
583 R-046 Replacing with new class 1 timber 50mm x 25mm (nominal)
reepers including application of two coats of wood
m 165.03
preservative(stain) (Only up to 4.60m2 of roof area).

584 R-047 Replacing with new kempus timber 50mm x 25mm (nominal)
reepers including application of two coats wood m 223.50
preservative(stain) ( Only up to 4.60m2 of roof area).
585 R-048 Supplying and fixing class 1 timber 50mm x 25mm (nominal)
reepers including application of two coats of wood preservative
m 156.96
(stain) (only up to 4.6m2 of roof area).

586 R-049 Supplying and fixing kempus timber 50mm x 25mm (nominal)
reepers including application of two coats wood preservative m 215.43
(stain)( only up to 4.6m2 of roof area).
587 R-050 Replacing with new class 1 timber 50mm x 50mm (nominal)
battens including application of two coats of wood
m 420.30
preservative(stain) (Only up to 4.6m2 of roof area).

588 R-051 Replacing with new kempus timber 50mm x 50mm (nominal)
battons including application of two coats wood m 402.62
preservative(stain) ( Only up to 4.6m2 of roof area)
589 R-052 Supplying and fixing class 1 timber 50mm x 50mm (nominal)
battens including application of two coats of wood
m 416.26
preservative(stain) (only up to 4.6m2 of roof area).

590 R-053 Supplying and fixing kempus timber 50mm x 50mm (nominal)
battons including application of two coats wood m 398.58
preservative(stain) ( only up to 4.6m2 of roof area)

Recommended by the Price Comitee - 2018 Page 47


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
591 R-054 Replacing with new class 1 timber 50mm x 100mm (nominal)
joists/ rafters, including application of two coats of wood
m 917.42
preservative(stain) ( only up to 4.6m2 of roof area).

592 R-055 Replacing with new kempus timber 100mm x 50mm (nominal)
joists/ rafters including application of two coats wood m 1,185.27
preservative(stain) ( only up to 4.6m2 of roof area)
593 R-056 Supplying and fixing class 1 timber 50mm x 100mm (nominal)
joists/ rafters including application of two coats of wood
m 869.34
preservative (stain) ( only up to 4.6m2 of roof area).

594 R-057 Supplying and fixing kempus timber 100mm x 50mm (nominal)
joists/ rafters including application of two coats wood m 1,112.83
preservative (stain)( only up to 4.6m2 of roof area)
595 R-058 Supplying and fixing any size class 1 timber beams including
application of two coats of wood preservative(stain) (Only up to m3 154,222.45
4.6m2 of roof area).
596 R-059 Supplying and fixing any size kempus timber beams, including
application of two coats wood preservative(stain) (Only up to m3 237,113.69
4.6m2 of roof area).
597 R-060 Supplying and fixing class1 Timber boarding , 20mm to 25mm
thick for valley gutters, flashings etc, inclusive of applying two
coats of wood preservative(stain)( Only up to 4.6m2 of roof m3 3,840.29
area).
598 R-061 Supplying and fixing valance boards beaded 225mm x 20mm
thick Ginisapu, including one coat of primer and two coats of
m 1,187.71
enamel paint (Flat iron bracket measured separately) .

599 R-062 Supplying & Fixing 0.47mm thick Zn / Al Valance board


m 1,571.14
including Screws. Nominal girth 470mm .
600 R-063 Extra over Supplying & Fixing 20x 6mm flat iron valance board
bracket at 0.6m c/c (total length 375mm) including welding nr 353.98
works, painting etc.
601 R-064 Fabricating and fixing Valley gutters and flashing in GI sheets
G22, including application of two coats of hot tar and blinding
m 1,525.15
with sand (timber board measured separately) 900mm wide.

602 R-065 Supplying & Fixing 0.47mm thick Zn / Al Valley gutters


m 1,535.35
including Screws. Nominal girth 470mm .
603 R-066 Fixing ridge tiles (available) laid on roof, 1:3 cement and sand
m 519.61
bedding and coloured to match tiles.
604 R-067 Cleaning and fixing timber (available), on roof, size 50mm x
m 57.54
25mm.
605 R-068 Cleaning and fixing timber (available), on roof, size 50mm x
m 62.27
50mm.
606 R-069 Cleaning and fixing timber (available), on roof, size 100mm x
m 269.83
50mm.

Recommended by the Price Comitee - 2018 Page 48


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
607 R-070 Cleaning and fixing timber (available), on roof, size 100mm x
m 269.83
75mm.
608 R-071 Cleaning and fixing timber (available), on roof, size 125mm x
m 269.83
50mm.
609 R-072 Cleaning and placing available roof trusses in position with
supplying necessary bolts and templates, 6m (20 L.ft) to 7.2m nr 12,600.00
(24 L.ft) spans.
610 R-073 Cleaning and placing available roof trusses in position with
supplying necessary bolts and templates, 7.6m (25 L.ft) to 8.7m nr 14,616.00
(29 L.ft) span.
611 R-074 Cleaning and placing available roof trusses in position with
supplying necessary bolts and templates, 9.1m (35L.ft)and above nr 16,632.00
up to 12.2m (40 L.ft) span.
612 R-075 Fixing available steel purlins on roof structures complete with
necessary bolts, welding, cleaning and painting two coats m 318.17
anticorrosive paints etc.
613 R-076 Supplying and fixing Asbestos sheets on 62mm x 62mm x 6mm
MS purlins not exceeding 1.35m crs.complete with necessary
bolts / welds GI roofing bolts at not more than 0.55m crs. on
every purlin, appling two coats of anticorrosive paint and appling m2 2,381.76
two coats of emulsion paint underside of sheets. Rate included
20mm x 6mm flat iron brackets for fixing valance board at 0.6m
c/c.
614 R-077 Supplying and laying 75mm x 75mm gauge 17 welded wire mesh
under the roof as directed. m2 215.68
615 R-078 Supplying and laying of laminated aluminium foil, 4mm thick
double side double bubble insulation layer, under the roof as m2 651.25
directed. (Ultra bubble reflective layer)
616 R-079 Fabricating and fixing suspended type ceiling PVC/Mineral fiber
board/Cement Board ceiling with T and and L sections complete
as per detailed drawing. (Ceiling panel rate not included.) Panel m2 2,078.76
size 600mm x 600mm.
Add only the cost of ceiling panel + 20% overhead and profit for
the ceiling panel per m2 for the above rate.
* Total ceiling rate A + B
617 R-080 Suppling, fabricating and erecting Web truss 20-40 feet span and
pitch 10-45degree with Top and Bottom Chord 2/60x60x5mm
and Internal members single angle 50x50x5mm, 10mm thick
Guzzet plate, 12mm thick base plate rate including welding and kg 322.52
two coats of anticorrosive paint and placing in position.

618 R-081 Fabricating and erecting "I" section truss 20-40 feet span and
pitch 10-45degree with "I" section rate included two coats of kg 328.58
anticorrosive paint and placing in position.

Recommended by the Price Comitee - 2018 Page 49


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION XII - PLASTERER

619 S-001 Black board plastering with 1:3 cement and sand finished smooth
with black cement floating including moulding at perimeter m2 1,455.12
20mm thick.
620 S-002 16mm thick 1:1:5 cement, lime and sand plastering to walls 2
m 926.44
finished smooth with lime putty.
621 S-003 1:1:5 cement, lime and sand plaster reveals 35mm to 150mm
m 306.55
wide finished smooth with lime putty.
622 S-004 Cement, lime and sand plaster, breaking the damaged areas and
replastering with 20mm thick 1:1:5 cement, lime and sand, m2 1,184.78
finished smooth with lime putty.
623 S-005 Cement and sand 1:3 plaster finished smooth with lime putty on
exposed faces of concrete surfaces and soffits, 10mm thick. m2 1,378.91

624 S-006 16mm thick cement and sand 1:5 plaster finished semi-rough with
wooden float. m2 729.61
625 S-007 16mm thick cement, lime and sand 1:1:5 plaster finished semi-
rough with wooden float. m2 745.27
626 S-008 1:1:5 cement, lime and sand plaster to reveals 35mm to 150mm
m 247.45
wide finished semi-rough.
627 S-009 Cement and sand rough plaster, breaking the damaged areas and
replastering with 1:1:5 cement, lime and sand plaster, finished m2 1,003.61
semi-rough with wooden float.
628 S-010 20mm thick damp proof course in 1:2 cement and sand trowelled
smooth and applied two coats of hot tar, blinded with sand. m2 1,363.63

629 S-011 Plinth plaster 12mm thick in 1:3 cement and sand finished
smooth with gray cement floating. m2 758.33
630 S-012 Plinth plaster 12mm thick in 1:3 cement and sand finished
smooth with coloured cement floating. m2 1,007.38
631 S-013 Rendering cement and sand 1:3, 20mm thick, finished smooth
with grey cement floating on walls. m2 1,115.22
632 S-014 Tiles glazed of approved pattern and colour with all specials
fixed to walls including raking plaster and bedding in cement
mortar 1:3, joints finished with tile grout to match colour of tiles m2 2,485.12
and cleaning. (Tile rate not included)
Add only the cost of tile + 20% overhead and profit for the wall
tile per m2 for the above rate.
* Total wall tilling rate A + B

Recommended by the Price Comitee - 2018 Page 50


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO

SECTION XIII - PLUMBER

Note
* All Brass taps, Ball valves, Gate valves, Stop valves, etc.

633 W-001 Supplying & fixing 20mm(1/2") dia. bidet spray approved best
nr 2,873.41
quality.(chromium plated)
634 W-002 Supplying & fixing approved cistern plastic with 20mm(1/2")
nr 4,159.72
flexible hose.
635 W-003 Supplying & fixing approved Closet ,with working order
including 20mm(1/2")dia. Brass chromium plated angle valve and nr 4,011.05
flexible hose. (Closet cost not included.)
Add only cost of the complete closet + 20% overhead and profit
per one set for the above rate.
* Supplied and fixed approved closet rate A + B
636 W-004 Supplying & fixing Bowl type approved urinal with trap and
nr 7,660.11
urinal flush valve complete to working order.
637 W-005 Supplying & fixing approved closet squatting foot rest type
(Orissa pan) with trap, supplied and fixed to working order,
including connection to sewer line. Rate includes for breaking nr 12,707.45
floor and concreting, cement rendering in damaged areas.

638 W-006 Supplying & fixing approved new closet squatting foot rest type
(Orissa pan) with trap, supplied and fixed to working order nr 9,263.45
including connection to sewer line.
639 W-007 Supplying & fixing mirror for bathroom 450mm x 600mm size
nr 2,444.26
approved quality with screws, plugs etc.
640 W-008 Supplying & fixing approved sink stainless steel with single
drain board with chromium plated wastewater chain, stay & waste
nr 6,448.38
plug (tap, brackets, water , waste water connection & brick work
measured separately).
641 W-009 Supplying & fixing approved ceramic sink 600mm x 375mm x
175mm overall size complete with waste plug, chromium plated
nr 13,674.18
waste chain & stay (tap, water connection, waste water
connection & brick work measured separately).
642 W-010 Supplying & fixing approved sink ceramic laboratory supplying
and fixing complete with waste, chromium plated waste chain,
nr 13,144.68
stay and waste plug. (tap, water & waste water connection, brick
work measured separately).
643 W-011 Supplying and fixing approved corner wash basin ceramic with
20mm(1/2") dia. chromium plated pillar tap, waste plug, chain
nr 10,999.44
and stay.(water connection and wastewater connection measured
separately).
644 W-012 Fixing wash basin suppled with 20mm(1/2") dia. Brass
chromium plated pillar tap, waste plug, chain and stay.(Water
nr 8,686.94
connection and waste water connection measured
separately).(Wash basin rate not included).

Recommended by the Price Comitee - 2018 Page 51


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
Add only cost of the complete wash basin + 20% overhead and
profit.(without taps and waste) per one set for the above rate.

* Supplied and fixed approved wash basin rate A + B


645 W-013 Removing and re-fixing available wash basin. nr 3,217.90
646 W-014 Constructing Stand post with 0.9m x 0.9m x 0.15m grade 20
concrete base and 0.15m x 0.15m x 0.75m RCC post,
20mm(1/2") plastic bib tap. Inclusive of 20mm PVC pipe
connection. Concrete base and post to be rendered with 1:3 nr 10,031.93
cement and sand finished smooth. (PVC supplied pipe measured
separately).
647 W-015 Supplying and installing 1000 L capacity (confirming to SLS
1174) water tank made of polymer materials of approved quality
nr 22,597.97
on sand bed. Rate for only water tank. PVC pipes, valves, fittings
measured separately.
648 W-016 Supplying and installing 2000 L capacity (confirming to SLS
1174) water tank made of polymer materials of approved quality
nr 38,527.04
on sand bed. Rate for only water tank. PVC pipes, valves, fittings
measured separately.
649 W-017 Supplying and installing 500 L capacity (confirming to SLS
1174) water tank made of polymer materials of approved quality
nr 14,246.44
on sand bed. Rate for only water tank. PVC pipes, valves, fittings
measured separately.
650 W-018 Supplying and fixing 20mm(1/2") dia. approved chromium plated
heavy quality swan neck type pillar tap with 01 No. P.V.C. faucet nr 3,196.16
socket to existing wash basin/sink.
651 W-019 Supplying and fixing 20mm(1/2") dia. approved brass heavy
quality, chromium plated bib tap with 20mm(1/2") dia. P.V.C. nr 1,663.04
faucet socket.
652 W-020 Supplying and fixing 20mm(1/2") dia. approved brass heavy
quality chromium plated Angle Value with 20mm(1/2") dia. nr 1,303.08
P.V.C. faucet socket.
653 W-021 Supplying and fixing 20mm(1/2") dia. approved plastic bib tap
nr 588.00
with 1 No.P.V.C faucet socket.
654 W-022 Supplying & fixing 20mm(1/2" dia.),150mm approved chromium
nr 1,564.60
plated shower rose.
655 W-023 Supplying and fixing 20mm(1/2") dia. approved shower rose
nr 2,203.75
chromium plated best quality Indian or equalant.
656 W-024 Supplying and laying Pipes PVC with specials, size 50mm dia. in
m 759.47
wastes of sinks. Type 600.
657 W-025 Supplying and laying Pipes PVC with specials, size 50mm dia.
rate includes for cutting trenches, testing and backfilling. (Type m 737.74
1000) depth of the trench not less than 450mm.
658 W-026 Supplying and laying Pipes PVC type 600 with specials, size
m 414.68
40mm dia. in waste of wash basins.
659 W-027 Supplying and laying Pipes PVC type 1000 with specials, size
40mm dia. Rate includes for cutting trenches, testing and m 599.45
backfilling. Depth of the trench not less than 450mm.

Recommended by the Price Comitee - 2018 Page 52


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
660 W-028 Supplying and laying Pipes PVC with specials, size 32mm dia.
(Type 1000) rate includes for cutting trencthes,testing and m 517.76
backfilling, depth of the trench not less than 450mm.
661 W-029 Supplying and laying Pipes PVC with specials, size 20mm dia.
type 1000 rate includes for cutting trenches, testing and back m 331.25
filling. Depth of the trench not less than 450mm.
662 W-030 Supplying and laying Pipes pvc with specials, size 63mm dia. in
m 717.99
waste water lines, vent pipes etc. (Type 400).
663 W-031 Supplying and laying Pipes pvc with specials, size 63mm dia.
m 1,034.53
(Type 1000).
664 W-032 Supplying and laying Pipes PVC with specials, size 25mm dia.
type 1000 rate includes for cutting trenches, testing and m 427.71
backfilling. Depth of the trench not less than 450mm.
665 W-033 Constructing Valve chamber 225mm x 225mm x 225mm in
1:2:4(20mm) concrete, complete with RCC lid, necessary lifting nr 3,929.11
hooks,R113 cement rendered in innner surfaces.
666 W-034 Supplying and fixing Gate valve ,brass, size 20mm dia. heavy
nr 2,214.20
quality.
667 W-035 Supplying and fixing Gate valve, brass, size 32mm dia. heavy
nr 3,258.94
quality.
668 W-036 Supplying and fixingGate valve brass, size 40mm dia. heavy
nr 4,758.50
quality.
669 W-037 Supplying and fixingGate valve brass, size 50mm dia. heavy
nr 5,858.99
quality.
670 W-038 Supplying and fixingGate valve brass, size 63mm dia. heavy
nr 7,431.61
quality.
671 W-039 Supplying and fixing Ball cock brass size 20mm dia. heavy
nr 1,396.10
quality.
672 W-040 Supplying and fixing Ball cock brass size 25mm dia. heavy
nr 2,568.11
quality.
673 W-041 Supplying and fixing Ball cock brass size 32mm dia. heavy
nr 3,457.71
quality.
674 W-042 Supplying and fixing Ball cock brass, size 40mm dia. heavy
nr 5,298.50
quality.
675 W-043 Supplying and fixing Ball cock plastic size 25mm dia. nr 493.16
676 W-044 Supplying and fixing Ball cock plastic size 20mm dia. nr 351.35
677 W-045 Supplying and fixing Ball cock plastic size 32mm dia. nr 531.94
678 W-046 Supplying and fixing Ball valve ,brass,size 20mm dia. nr 1,819.97
679 W-047 Supplying and fixing Ball valve brass size 25mm dia. nr 3,123.50
680 W-048 Supplying and fixing Ball valve ,brass, size 32mm dia. nr 3,877.78
681 W-049 Supply and fix 20mm dia Cromium plated Brass Conseal Valve
nr 2,991.32

Recommended by the Price Comitee - 2018 Page 53


SE.- ITEM DESCRIPTION
UNIT RATE
NO. NO
SECTION XIV- SCHEDULE OF TRANSPORT

682 Y-001 Transport of metal, sand, gravel and earth beyond 10 km, per km
km 40.00
rate for one cube.
683 Y-002 Transport of cement beyond 10 km, per km rate for one bag
km 0.67
(50kg)
684 Y-003 Transport of steel beyond 10 km, per km rate for 1000kg. km 13.33
685 Y-004 Transport of bricks beyond 10 km, per km rate for 1000Nos.
km 40.00
686 Y-005 Transport of calicut tile beyond 10 km, per km rate for 1000Nos.
km 40.00

Recommended by the Price Comitee - 2018 Page 54

You might also like