You are on page 1of 3

DESIGN INFORMATION SHEET

GABION WALL

CUSTOMER INFORMATION
Company:
Requested by
Tel.: Fax: e-mail:
Project name: Project Nº:
Location: City / State / Country:
(*) MACCAFERRI INFORMATION
Company or distributor:
Requested by: Project Nº:
(*) DESIGN LEVEL STANDARD REQUIRED
Level 1 (Conceptual Level 2 (Preliminary Level 3 (Final
Proposal) Suggestion) Design)

WALL PARAMETERS LOADS ON WALL


Wall height above GL (H) Uniform load (qg) kN/m2

External steps? Y/N Line load (Qg) kN/m

Wall batter angle () º Line load offset (Xg) m


kN/m
Rockfill unit weight (R) 3 BRIDGE LOADING
Vertical uniform load underneath
Gabion porosity % kN/m2
bankseat
Filter cloth behind Horizontal uniform load underneath
Y/N kN/m2
wall? bankseat
Filter cloth under
Y/N Bankseat width kN
wall?
SEISMIC LOAD CONDITION (Please note that the above is for Gabion bridge abutment only)
Horizontal acceleration
coefficient
LOADS ON BACKFILL
Vertical acceleration coefficient STRETCH 1 2
(q kN/m
PHREATIC SURFACE Uniform load on stretch
)
21 2

(Q
Initial height (Wv) m Line loads kN/m
)
Slope angle stretch 1 ( W1) m Line loads offset (X) 10 m

Stretch 1 lenght (Wh1) m FOUNDATION SOIL


Soil
Slope angle stretch 2 ( W2) m
description
kN/m
Stretch 2 lenght (Wh2) m Soil unit weight (f) 18 3

Internal friction
BACKFILL SOIL PROPERTIES angle
(f) 30 º

Soil Cohesion (cf) kN/m


description 0 2
kN/m Allowable bearing kN/m
Soil unit weight (s) 3 2
capacity
Internal friction angle (s) º Foundation depth (Hf) m
kN/m
Cohesion (cs) 2 Berm width (Lf) m

Slope profile stretch 1 (s’) º Toe slope angle (f ) º


Horizontal distance
stretch 1
(Ls’) m FOUNDATION ADITIONAL LAYERS
Slope angle stretch 2 (s”) º Layer f1 f2

BACKFILL ADITIONAL LAYERS Soil description


kN/m
Layers s1 s2 Soil unit weight () 18 3

Soil description Internal friction angle () 38 º


kN/m
Soil unit weight () 3 Cohesion (c) 0 kPa

MI/WDC/QF/01
R00/1.07.08
1
Internal friction angle () º Thickness (h) 0.3 m
Free water surface max
Cohesion (c) kPa (Hwmax) m
height
Free water surface min
Layer inclination () º (Hwmin) m
height
Initial height (h) m

SAFETY FACTORS
Global Stability Sliding Overturning Bearing Capacity
Seismic No seismic Seismic No seismic Seismic No seismic Seismic No seismic

TYPICAL SECTION

PROJECT DESCRIPTION
RIVER BED PROFILE
Lined section

Reno mattress apron


Sack gabions
foundation
(Please tick “” the appropriate box)

(*) MACCAFERRI SUGGESTIONS (AREA MANAGER)

Maccaferri Environmental Solutions Pvt. Ltd.


1003,10thFloor,Casablanca,
Plot NO.45,Sector-11,CBD Belapur,Navi Mumbai-400614
Tel. (022) 27580475 / 0931/32/27565906- Fax (022)
27580488
E-mail: technical@maccaferri-india.com -Web site:
www.maccaferri-india.com

MI/WDC/QF/01
R00/1.07.08
2
(*) ADDITIONAL INFORMATION
Section to Section to Bill of
Only drawing Maccaferri specs Drawing
be be Plan Elevation quantitie
without calculation for drawings template
calculated drawn s

Yes Yes Yes Yes Yes Yes

No No No No No No

This Design Info Sheet is for static analyses only.


Should hydraulic analyses be required please use the channel protection Design Info Sheet.

Attachments: File name:


Photos
Site Investigations
Drawings
NOTES: (*) For Maccaferri use only.

Maccaferri Environmental Solutions Pvt. Ltd.


1003,10thFloor,Casablanca,
Plot NO.45,Sector-11,CBD Belapur,Navi Mumbai-400614
Tel. (022) 27580475 / 0931/32/27565906- Fax (022)
27580488
E-mail: technical@maccaferri-india.com -Web site:
www.maccaferri-india.com

MI/WDC/QF/01
R00/1.07.08
2