SpecificationS

2 CAPITAL GATE CAPITAL GATE 3

Summary STRUCTURAL
Design Loads •
Power Feed
 Office Areas are provided with 63 Amp three phase
PLUMBING AND DRAINAGE
General
FIREFIGHTING
General •
Telecommunication
 State-of-the-art passive connectivity solutions
Specification •  Office area superimposed Dead Load = 2.4kPa,

Live Load = 5.0kPa Cladding.


power supply for smaller units and 100 Amp three
phase power supply for larger units, locally for each
•  Sanitary wares, water tanks, domestic water

systems, soil/waste/vent and overflows, irrigation


•  Sprinkler installation, external hydrant system,

manual fire protection system of fire extinguishing,


allow tenants to deploy a full range of
telecommunications services from the UAE’s
‘Shell and Core’ Commercial Office Space office unit with a local Isolator (based on three system and rainwater system have been included. gas fire suppression system, fire alarms, and fire leading service providers.
•  Fully unitised facade curtain walling system is made
(Level 2 to 16) offices per floor). These are fed from the sub main detectors have been included.
up from 2 storey height diamonds which make up •  The main source of the building’s potable water, •  Optical fibre connections with up to 10G capacity
the ‘free form’ facade comprising double glazed distribution boards in the electrical room (each from the ADWEA distribution line, is stored in a tank •  The building consists of manual and automatic are available to tenants for connections to
factory sealed triangular glass units and steel floor), through a KWH meter provided in the meter at the basement floor, which undergoes a filtration firefighting equipment for complete building service providers.
section frames. room. Each tenant will provide a distribution board system. The concrete water tank is a double protection. The fire sprinkler system is entirely •  Tenants must install their own I.T. infrastructure in
as per their load requirements and connect to the compartment type, allocated for domestic water, independent from the hydrant network as required
Dimensional Information their office areas. Tenants will be required to:
local Isolator provided by the Landlord. fire protection system, and irrigation source. by Abu Dhabi Civil Defense Authority (ADCDA).
•  Floor to floor height: 4.00m (4,000mm). – Install and maintain the structured cabling and
•  Tenant supplied distribution boards are as per Aside from preliminary filtration, the domestic water All floors are provided with accepted zonal fire
•  Floor to ceiling height: 2.50–2.75m network infrastructure within their leased space.
ADDC/Abu Dhabi Water and Electricity Authority passes through a proven anti-legionella chemical sprinkler suppression with individual zonal control
(2,500–2,750mm). – Install and manage server room/data centre as
(ADWEA) regulations. Tenants will obtain the dosing system. Water tanks are provided at valve. Each floor has three fire hose cabinets (FHC)
required for their business.
•  Ceiling to void average: 0.80m (800mm). necessary approvals from the authorities for their basement, Level 1 and Level 17, with compliance at the common area, which can accommodate up
– Install and manage their own back office, voice
•  Raised floor height: 0.15m (150mm). layouts and power distribution requirements. KWH to ADDC requirements of minimum 2 days to 30m standard radius of service. All electrical
and application server systems.
All dimensions are approximate meters shall be provided by ADDC/ADWEA consumption storage. rooms are supplied with either automatic fire
– Obtain services from the telecommunications
Authorities after tenant fit-out completion and •  The plumbing system consists of metered cold extinguishers or FM 200 or foam type fire
service providers directly.
ELECTRICAL SERVICES inspections of the electrical installation are carried water (CW) network, filter cooled cold water supply suppression systems.
out by ADDC/ADWEA.
•  Additional services, including voice, data,
General (FCCWS) and centralised hot water (HW) Office Area
•  All common area lighting, power, two escape
high speed data links, video and television access,
•  No separate provision for power backed by standby distribution. The HW network for the office toilets, •  The office areas are fitted with the following:
may be requested from ADNEC, although tenants
staircases and elevators are fed from the landlord’s generator has been made for the tenant areas hotel and dining area is enhanced with heat tracing A) Upright sprinkler heads for firefighting and; are advised that these may be subject to leasing
distribution network. One passenger elevator is except the emergency lighting. system for fast acquisition of hot water and uniform B) Recessed sprinkler stub outs. agreements and availability.
backed up by standby generator power, for use in water temperature supply of 55°C.
case of emergency. All life safety systems and MECHANICAL SERVICES •  The drainage system is laid at all areas where OTHER SERVICES Security
essential services are backed up by the standby HVAC System water service is available and tapped to the main Fire Alarm and Public Address
•  Security system has been provided with 24 hour
generator. In addition, some of the life safety General drainage point. Evacuation Systems physical security presence incorporating CCTV
system and essential system outlets are backed up •  Fresh air ventilation, fan coil unit (FCU) systems,
•  Smoke detectors have been provided within each surveillance of the main entrances, elevator lobbies
by uninterrupted power supply (UPS) to ensure fresh air handling units (AHUs), smoke extract Office Area and external areas. Tenants will use security access
office area. Smoke detectors are provided with
availability of power at all times. ventilation system, variable volume air-conditioning
•  Separate toilets for male and female are present cards in conjunction with proximity readers to
approx. two metres of additional cable for lowering
system, and chilled water (CW) system are provided. on each office floor. access the security barriers and at each of the main
Power Supply in to the ceilings. Voice evacuation speakers
The cooling requirement is served by TABREED •  Each office area is provided with: A) Cold water are provided within each office space, for entrance points.
•  The building is supplied at 11KV from an Abu Dhabi
district chilled water network, facilitated by an stub-out with meter provision to be applied to announcements.
Distribution Company (ADDC) primary substation Elevators – Passenger
energy transfer station at the basement and Level 1 ADWEA when occupied and; B) Soil, waste,
and network to basement sub-station. Emergency Lighting •  Three passenger elevators are provided for office
of the building as the primary supply of chilled and vent pipes for future pantry or toilet provisions.
•  Power is transformed to the operating voltage of •  Sufficient emergency lights are provided with floors, serving Ground floor to Level 16. Each
water network consisting of two units of rated heat
415 volts by five, 1,500KVA transformers installed in additional length of cable to lower in to the ceilings, elevator is 1,600kg (21 person) capacity. One
exchangers. The resulting or secondary chilled water
the substation. Main distribution boards (MDBs) are together with one wall mounted type exit light for elevator is backed up by generator power for use in
lines will be metered as being conveyed by four
fed from the transformers installed in the basement installing above the entrance/exit door for each case of mains power failure.
rated pumps serving AHUs and FCUs mounted
low voltage (LV) switchgear room, adjacent to the office space. All the emergency and exit lights are Elevators – Service/Goods
at all floors of the building.
substation. MDBs distribute power to the backed up by the central battery system, which is •  One office floor service elevator of 1,600kg capacity
development, through cable routes, rising bus bars, Office Areas backed up by the standby generator. is provided.
sub-main distribution boards (SMDBs) and •  The office areas including basement, ground and
mezzanine are served by centralised AHUs (2 Nos.) Ceilings
distribution boards (DBs).
located at Level 1.
•  All suspended ceilings incorporating plasterboard
and/or ceiling tiles is by the tenant.
•  The office areas are provided with the following
service ‘stub-outs’, including supply and return air Floors
ducts and metered chilled water supply and return •  Fully accessible raised access flooring (600 x 600
lines (provisions only inside the office areas), that tiles) with an overall floor depth of 150mm allowing
are interfaced with building management system 110mm clear void may be provided. (Currently
(BMS) control. FCUs for each office area will be under review).
provided by the tenant. Walls
•  The cooling criteria is based on the following data: •  Unplastered block and steel columns with
A) Average year round summer and winter design cementitious fireproofing to be clad or painted
conditions in offices are to be maintained at by the tenant.
23°C and 21°C ±1°C, with relative humidity set
Floor Power
at 50% ±5% and; B) The outdoor ventilation rate
•  All power reticulation, floor boxes, general purpose
is 8.0 l/s/person with approx. 8–12 air changes per
outlets and connections to DBs are by the tenant.
hour (ACH).
Lighting
•  All lighting and connections to DBs are by
the tenant.
Toilet and Pantry
•  High quality finishes including tiling to floor and
walls, ceilings, recessed lighting, ablution facilities
and marble vanity tops are provided.
4 CAPITAL GATE CAPITAL GATE 5

Schedule of areas Ground floor plan

Areas
Lobby
Core Areas
Lifts
Hyat t Hotel

Profiterole
Café
OFFICE

Lobby
34 CAPITAL GATE CAPITAL GATE 35

FLOOR PLANS

key Level 16
Floor area:
Level 16
Floor area:
Level 15
Floor area:
Level 15
Floor area:
Level 14
Floor area:
Level 14
Floor area:
Level 13
Floor area:
Level 13
Floor area:
Level 12
Floor area:
Level 12
Floor area:
construction 353 sq m 3,800 sq
353
ft sq m 3,800 sq ft 1,029 sq m 11,076
1,029
sq ftsq m 11,076 sq ft 1,025 sq m 11,033
1,025
sq ftsq m 11,033 sq ft 1,047 sq m 11,269
1,047
sq ftsq m 11,269 sq ft 1,040 sq m 11,194
1,040
sq ftsq m 11,194 sq ft

facts
Height
160m / 35 storeys
Incline
18 degrees
Direction
Westward (East to West)
Overhang of the tower
from the base
33m
The Cardinal facade is 51% more
efficient than a standard typical
facade in restricting solar heat
to the building. This reduces the
energy consumption by HVAC
system by 15%.
Foundation piles
490
Depth of piles
20–30m Level 11 Level 11 Level 10 Level 10 Level 09 Level 09 Level 08 Level 08 Level 07 Level 07
Floor area: Floor area: Floor area: Floor area: Floor area: Floor area: Floor area: Floor area: Floor area: Floor area:
Structural steel 1,056 sq m 11,366
1,056
sq ftsq m 11,366 sq ft 1,041 sq m 11,205
1,041
sq ftsq m 11,205 sq ft 1,040 sq m 11,194
1,040
sq ftsq m 11,194 sq ft 1,025 sq m 11,033
1,025
sq ftsq m 11,033 sq ft 1,033 sq m 11,119
1,033
sq ftsq m 11,119 sq ft
in Capital Gate
13,200 tonnes
Diagrid systems
1 external – 1 internal
Diagrid nodes
702 external – 120 internal
Triangular glass panes
on facade
12,500
Diamond shaped sections
on facade
720
Total built up area
53,100 sq m
Total office area
14,396 sq m
Total hotel area
25,050 sq m

Key Leasing Level 06


Floor area:
Level 06
Floor area:
Level 05
Floor area:
Level 05
Floor area:
Level 04
Floor area:
Level 04
Floor area:
Level 03
Floor area:
Level 03
Floor area:
Level 02
Floor area:
Level 02
Floor area:

Facts 1,024 sq m 11,022


1,024
sq ftsq m 11,022 sq ft 1,027 sq m 11,054
1,027
sq ftsq m 11,054 sq ft 1,012 sq m 10,893
1,012
sq ftsq m 10,893 sq ft 1,008 sq m 10,850
1,008
sq ftsq m 10,850 sq ft 994 sq m 10,699 994
sq ftsq m 10,699 sq ft

Offices available from


353–1,056 sq m
Provision for 2.5–2.75 floor
to ceiling height
150mm raised floor
Two fitted pantries
and WCs per floor
Secure access to each floor
Dedicated covered parking
1:40 sq m
36 CAPITAL GATE CAPITAL GATE 37

FLOOR PLAN MEZZANINE level FLOOR PLAN level 02

Areas Floor Area


Hyatt 994 SQ M
Core Areas 10,699 SQ FT
Lifts

Areas
Office Space
Core Areas
Utilities
Lifts

Tea/Coffee
Foo
t
brid
ea g
cce
ss t
oo
ffic
e ca
r pa

Prive
rk

Business Bar/Lounge

Meeting Room 4

Meeting Room 3

Meeting Room 2

Meeting Room 1
38 CAPITAL GATE CAPITAL GATE 39

FLOOR PLAN level 07 SPLIT FLOOR PLAN level 14

Floor Area Floor Area


1,033 SQ M 1,025 SQ M
11,119 SQ FT 11,033 SQ FT

Areas Areas
Office Space Office Space
Core Areas Core Areas
Utilities Utilities
Lifts Lifts
40 CAPITAL GATE CAPITAL GATE 41

SPACE PLAN level 07 SPACE PLAN level 07

Floor Area Floor Area


1,033 SQ M 1,033 SQ M
11,119 SQ FT 11,119 SQ FT

Areas Areas
Office Space Office Space
Core Areas Core Areas
Utilities Utilities
Lifts Lifts

PA (2 PAX)

Boardroom
(18 PAX)
CEO CEO

Informal Manager 01
Manager 01 Meeting

Workstations
(34 PAX)

Manager 02
Manager 02

Manager 03
Manager 03

Workstations
24 PAX

Reception/
Waiting

Lift
Lobby
Reception/
Waiting

Fax/copy
area
Meeting
(6 PAX) Workstations
Meeting (6 PAX)
(4 PAX)

Fax/copy Boardroom
(14 PAX)

Workstations
Store 36 PAX
Room
Meeting
(4 PAX) Meeting
(6 PAX)

Foldable
Partition

Server
Room
Seating

Server Room

Fax/copy
Workstations area
Fax/copy 12 PAX
area

Workstations
18 PAX

Pantry/ Pantry/
Breakout Breakout