You are on page 1of 2
RCM ACI-Builder Ver. 5.1.0.0 Project Nos on Project Name: ‘ALDLP Job Title: £2 (PO) ‘ales by ENGR, UDAYAN | Checked by: ENGR. UDAYAN Sheet: of Date: 09-02 2018 Concretecompressive strengh Reinforcement yield strength Density of reinforced concret= Flexare strenath reduction factor Shear strengthreduction factor Pile Capacity (working oad) Applied Column Service Loads: Column deed load (working) Column live load (working) Column Geometry ox = 425mm Column tengthinxSiecion oy = 425mm Column widthin¥-Drection Pile Caps Geometry: -dp = 450mm Pieciameter H 2675 0m Ticknens piece : Ceareaver 3 effective deh 2 Pile edge offset : Pretolerance s Distance between ple ee L=s+cp+2*e=2050mm —Lengthofple cans 3 =ap+2-e=s000m vist ofple caps a =05*(S-Cx)+t=487.5mm Shear Span a/d =0929 Shear-SpanDepthRatio Check Pile Capacity: +ap-+ ap W =L™B=H*We=384724N Self Weight ofpilecans Rw = [P(d) + P(L) + WI/ 2 = 286.586 KN Pile Reaction (applied working load) Rw /Pc=0.819 Pile Demand-Capacty Ratio «Pile Demand-Capacity Ratio = Rw / Pc=0.819<1 ..0K Design of One Way Shear (Beam Shear Action): ile ulimate reaction (Applied shear force Vu) Ru = Wu = max of [1.2* P(d) + 1.6 *P(L), 14 P(@)] /2 =358.6 KN Determine the type of one way shear: afd =0.020<1 Shear-Span Depth Ratio, ‘The enticalsecton takes place atthe face of column indirection of short wath "S" Check Pile Caps Depth Efficiency To Carry The Applied Shear Force: Concrete shear strength for one way deep beam action: Vc= Phi * K* {0.16 * Sari{fc) + 17* Rho * aipha}*B* d DATS KN Factor of shear enhancement Ratio ofusedrein‘orcement, seedesign of flexure below. Forone way deep beam shear action(a/d <1) Maximum concrete shear strength for one way deep beam actio \Vc_mat = Phi * 0.83 * Sqri(Fc)* 8 * d = 1613.023 kN Used concrete shearstrength for one way deep beam action: \Ve_used = Min of {VG Ve_maxp = 412.975 kN - One Way Deep Beam Shear Demand Capacity Ratio = Ru / Ve_used = 0.821 ENGR. UDAYAN CHAKRABORTY [RCM ACI-Builder (Reinforced Concrete Members ACK- Builder) RCM ACI-Builder Ver. 5.1.0.0 on ‘ALDLP £2 (PO) ‘ales by ENGR, UDAYAN | Checked by: ENGR. UDAYAN Sheet of Date: 09-02 2018 Design of 2-PileCaps According to ACI3L@M-11. Determine Area of Flexural Reinforcement: Mu = Ru*a/B = 183.408 kNm /m Applied ultinatemoment permeter length c= 0.003 Concrete compressive strain 005 Reinf.tensilestrain 0.85 >= {beta = 0.85-0.05|(Fe-28)/7]} >= 0.65, then beta = 0.636 Equivalent compressive depth factor Ct =[eq/lectes)]*d = 0.375%d = 196.38 mm Neutralaxs dept ymax ~ beta * Ct 16453 mm ‘Maximum equivalent compressive blode dapth Y= d~{Sart(e*d-{(2"Mu)/(phi=0.85+Fe*(b=1000)))} = 15.45 mm Equivalent compressive block depth Y= 18.45 mms lesser than Ymax= 164.53 mm ‘Section works as singly reinforced section As(req) = 0.85" Fc (b=1000) *¥/fy = 938.01mmz/m Required area of flexural reinforcement pe:meterlength | Determine minimum erea of flexure reinforcement: ‘As(min) = Max of {Min of fAs{min), As(rnin2)], As(min3)}= 1250.67 mm2/m Where: -As(mint) = Max of (0.25 * {Sart{Fc)/ fy}* (b=1000) * 4, 1.4* (b=1000) *¢ / fy) = 1750.00 mm2/m + As(omind) = (4/3) * As(reg) = 1250.67 mna/m fy = 420 Mfa then A(smin3) = 0,018 * (5=1000)* H/2= 607.50mm2/m_ for Shrinkage & Temperature (Each Face) Used area of flexure reinforcement: As(used) = Max of {As(req),As(min)} = 1250.67 mm2{m. -As(used) = T16 @ 16 an/m Rho = (100 / 16) * [61 = 1542]/ [4 * (b=1000) * (4=525)] = 0.00239 Ratio of used reinforcement ENGR. UDAYAN CHAKRABORTY

You might also like