You are on page 1of 26

Explore Spreading Science & Technology

E l e c t r o n i c s with

Exclusive Electronic Hobby Kits


Beginner Level : Intermediate Level : Advanced Level :
Simple Water Level Indicator Flashing LEDs Moving Message Display
Water Level Indicator Water Pump Controller-cum-Motor Infrared Proximity Detector
Fire Alarm Timer Infrared Remote Switch
Simple Burglar Alarm Garage Light and Security Control Frequency Measurement
Simple Touch Bell Low-Range AM Radio Transmitter Clap-Based Switching for Devices
Musical Touch Bell FM Transmitter Car Security System with Remote Control
Musical Doorbell with Memory FM Receiver Temperature Indicator
Magic Eye and many more… Burglar Alarm System Light Sensor
Traffic Light Control IR Counter Physics Catalog 2009

n
Smoke Alarm and many more… Code Lock
Stop-Watch and many more...

Spreading Science & Technology

141-B, Electronic Complex, Pardesipura, Indore - 452 010 India, Tel : 91-731-4211500,
TeleFax : +91-731-4202959, E-mail: info@nvistech.com, Website : www.nvistech.com
Nvis Technologies is a Scientech Group Enterprise
Contents Page No.
NV6000 Electricity Lab 4
NV6002 Electrostatic Lab 5
NV6004 Magnetism Lab 6
NV6005 Solar Energy Trainer 7
NV6006 Optics Bench 8
NV6006C Divergence of Laser 9
NV6006D Inverse Square Law 10
NV6007 Fuel Cell Trainer 11
NV6008 Wind Energy Trainer 12
NV6012 Coulomb’s Law Demonstrator 13
NV6021 Half Shade Polarimeter 14
NV6022 Viscosity Measurement Apparatus 15
NV6023 Malus Law Setup 16
NV6025 Planck's Constant Determination using LED 17
NV6026 Moment of Inertia table Setup 18
NV6028 Fresnel Biprism Setup 19
NV6029 Nodal Slide Assembly Setup 20
NV6030 Carey Foster's Bridge Setup 21
NV6031 Stefan's Law Trainer 22
NV6032 Calibration of Voltmeter and Ammeter using Potentiometer 23
NV6034 Current Carrying Coil Setup 24
NV6037 Desauty's and Schearing Bridge Trainer 25
NV6040 Young's Modulus Setup 26
NV6041 Post Office Box Trainer 27
NV6042 Resloving Power of Telescope 28
NV6043 Thermal Expansion Trainer 29
NV6045 Ray Optics Study Setup 30
NV6050 Boyle’s Law Demonstrator 31
NV6101 Hall Effect Trainer 32
NV621 Gauss & Tesla Meter 33
NV622 Measurement Unit 33
NV623 Constant current Power Supply 33
NV6102 Measurement of susceptibility of paramagnetic solution (Quinck's Tube Method) 34
NV6103 e/m measurement setup 35
NV6104 Newton's Ring apparatus 36
NV6105 Resistivity & Band gap Measurement (Four Probe method) 37
NV6106 Semiconductor Energy Band-Gap Measurement Trainer 38
NV6107 Ballistic Galvanometer Setup 39
NV6108 Hysteresis Loop Tracer 40
NV6109 Ultrasonic Measurement Lab 41
NV6110 Measurement of Wavelength of Laser by Diffraction Grating 42
NV651 Incandescent light source 43
NV652 Mercury light source 43
NV653 Sodium light source 43
NV654 Laser source 43
NV656 Spectrometer Set-up 44
NV657 Travelling Microscope 45
NV660 Set of Polarizers 46
Nanotechnology
NV4500 Introductory Nano Kit 47
NV4501 Nano TiO2 Solar Cell Kit 48
NV4502 Ferro Fluid Demonstrator 49
NV4515 Artificial Muscle Trainer 50
Simtel Nanotechnology 51
Simtel Physics 51
NV6000 NV6002
Electricity Lab Electrostatic Lab
Physics

Electricity Lab NV6000 is a versatile Training System for the Scope of Learning
laboratory. It is designed such that all the basic electrical circuits ¡
To study the Resistances individually as well as in series and in
can be tested. The experiments given with this Training system parallel connections.
will develop clear understanding of series and parallel circuits, ¡
To study the Ohm's Law mathematical relationship between three
variable Voltage (V), Current (I) and Resistance (R).
electromagnetic induction, coil behaviour with AC and DC
¡
To study the voltage and current flowing into the circuit. Electrostatic Lab NV6002 is a versatile training system to be Scope of Learning
circuits, diode and transistor characteristics etc. This simple
¡
To study the Kirchhoff's Law for electrical circuits.
training system provides a strong platform for detailed studies in used in the laboratories. It introduces the basic concepts of To study the Charge Induction in Electrostatics
n
¡
To study the R-C circuit and find out the behaviour of capacitors in a
electricals and electronics. R-C network and study the phase shift due to capacitor. electrostatics like charging by friction, induction and
To study the Charge Conduction in Electrostatics
n
¡
To study the L-C circuit and find out its behaviour as resonance conduction. With this system static charge polarity can be easily
¨
Stand alone operation circuit. determined. This system is provided with a Digital Electroscope,
To study the Pith ball pendulum Electroscope
n
¨
Durable, Easy to use kit ¡
To study the characteristics of a semiconductor diode. Pith ball pendulum, Charge Demonstration Tube. A set of To study the relative charges of different rods with the help of
n Digital
¨
Includes all the Basic Electrical fundamentals ¡
To study the characteristics of a transistor. Display in milli volts
¨
Solderless connections different rods and clothes are provided to study the electrostatic
¡
To study the behaviour of current, when light bulbs are connected in
¨
Complete set of coils and cores to understand the Basics circuit. charges by their different combinations. To study
n the Electrostatic Charge with the help of Charge
of Electro magnetic induction and Transformers Demonstration Tube
¡
To understand the Faraday's Law of electromagnetic induction.
¨
Provided with a component box to perform all the ¡
To study the phenomenon of mutual induction. To study
n the Electrostatic Charge by the combination of different
experiments ¨
Complete training system to study the fundamentals of
¡
To study the Lenz's Law and effect of Eddy current. rods & cloths
¨
CBT covering all the experiments Electrostatics
¡
To study a Relay and construct a switching circuit by using relay.
¨
Extensive e-Manual ¡
To study Oersted experiments. ¨
Electrostatic charging by Induction, Conduction, Friction
¨
2 Year Warranty Accessories Include :
¡
To convert a Galvanometer into Volt meter. ¨
Digital Electroscope consists of Charge Polarity
Digital Electroscope
¡
To convert a Galvanometer into Ammeter Indicator & Display
Technical Specifications ¡
To construct and study a step down transformer with the help of
Pith balls
given coils and cores.
¨
Provided with a learning Software Pendulum Stand
DC Mains Supply : 5 V, 200 mA
AC Mains Supply : 6 V, 1A ¡
To construct and study a step up transformer. ¨
Extensive e-Manual Charge Demonstration Tube
Relay : 5V ¡
To study the effects of moving I core on a step up transformer. Rods - Teflon, Ebonite, Perspex
¨
2 Year Warranty
Galvanometer : 30 - 0 - 30 ¡
To study the hysteresis curve Cloths - Silk, Woolen, Cotton
Galvanometer Resistance : 80 W
Light Bulbs : 6V
Training System includes
Potentiometers : 25 W, 1 W,
10 KW, 1 W 1. Components box with
a. Resistors Technical Specifications
Switch : 1 Pole, 2 Way Toggle type
Core types : E, I, U b. Capacitors
c. Transistors Electroscope Display : Measures relative intensity of charge
Coils d. Diode in millivolts
e. Potentiometer Charge Polarity Indicators : Blue LED - Negative charge,
No. of Turns Wire Dimension Maximum Current Inductance 2. E, I, U cores Green LED - Positive charge
(mm.) (Amp.) (Approx.)
3. Set of coils Rods : Teflon, Ebonite, Perspex
200 Turn 0.818 1.46 590 mH 4. Magnetic compass
400 Turn 0.573 0.728 2.3 mH Cloths : Silk, Cotton, Woolen
5. Bar magnets
800 Turn 0.404 0.363 9.2 mH
Subject to Change

Subject to Change
6. Screw driver Pith balls (with pendulum) : Single & pair is provided for different
1600 Turn 0.251 0.144 34.2 mH observations
3200 Turn 0.170 0.072 134 mH 7. Multimeter
8. Connection patch cords Mains Supply : 90 - 275 V, 50 / 60 Hz
Fuse : 1 Amp.
9. CBT covering all the above experiments Pith ball Pendulum
Mains Supply : 230 V ±10%, 50 Hz
Dimension (mm) : W 345 × D 245 × H 105
4 5
NV6004 NV6005
Magnetism Lab Solar Energy Trainer
Physics

Lenz's Law Floating Magnets Homopolar Motor


Demonstration Experiment Experiment

Solar Energy Trainer NV6005 is a versatile training system to be Technical Specifications


Solar Panel : Consists of 6 solar cells
used in laboratories. It introduces the basic concept of solar cell Open circuit Voltage of each solar cell : 1.5 V
Magnetism Lab NV6004 is a versatile training kit to be used in ¨
Complete training system to study the fundamentals of Short circuit Current of each solar cell : 150 mA
magnetism (photovoltaic cell) of converting sunlight directly into electrical
laboratories. It provides a good basis for understanding the Voltmeter : 0 -10 V
¨
Provided with easiest way of magetic field
demonstration Ammeter : 0 - 500 mA
fundamentals of magnetism. This kit is provided with different energy. The system works as a live demonstration unit of solar
¨
Dramatic demonstration of Lenz's Law Potentiometer : 5 K
types of materials and shapes of Magnet, Magnetic Compass, ¨
Homopolar motor demonstration cells in terms of its concepts and applications. This system is AA Rechargeable NiCd Battery : 1.2 V

Magnetic Field Demonstrator, Lenz's Law Apparatus and Motor ¨


Provided with floating ring magnets and a dowel to Bulb : 1.2 V, 220 mA
demonstrate magnetic levitation provided with Solar Energy Trainer and a Solar Panel.
Fan : 1.5 V, 450 mA
Assembly. ¨
Provided in a good quality carrying case with foam
FM Receiver : 12 V
inserts
¨
Provided with a learning Software
¨
Extensive e-Manual ¨
Complete training system to study the Scope of Learning
Scope of Learning ¨
2 Year warranty fundamentals of photovoltaic system
¡
Calculation of voltage and current of solar cells in series
Study of different types and shapes of magnet
n
Contents & Specifications ¨
The system has two modes for study: ¡
Calculation of voltage and current of solar cells in parallel
Plotting
n of the combined magnetic field of the earth and a bar Types of material of magnet : Characteristics and Application Modes
¡
Study of I - V curve and power curve of solar cells to find out
magnet and to locate the neutral points and calculate the magnetic 1. Alnico maximum power point (MPP)
moment and the pole strength of the magnet 2. Ceramic or Ferrite ¨
On board voltmeter and ammeter are provided to
3. Rare earth magnet (NIB) measure the voltage and current respectively, ¡
Calculation of efficiency of solar cells
Study of magnetic field lines by Magnetic Field Demonstrator
n
Shapes of Magnet : during various modes of operation ¡
Application of solar cells in domestic purposes :
Study of magnetic levitation by Floating Ring Magnets
n 1. Bar Magnet
2. U-Shape Magnet ¨
Charging the battery using solar energy - Charging of battery, both on load and no load condition
Study of Oersted Law
n
3. Horse shoe Magnet - Operating bulb, fan and FM receiver
Study of Faraday's Law of Electromagnetic Induction
n
4. Cylindrical Magnet ¨
Weather proof solar cells
5. Ring Magnet
Study of Lenz's
n Law 6. Disc Magnet ¨
Portable and light weight
Magnetic Compass
Study of Electromagnet
n
Magnetic Field Demostrator ¨
Extensive e-Manual
Subject to Change

Subject to Change
Study of the principle of motor by a simple assembly of motor
n
Lenz's Law Demonstrator
Motor Assembly
¨
2 Year Warranty
Coil :
No. of Turns : 400
Inductance (approx.) : 2.3mH
Max. Current : 0.728 A

6 7
NV6006 NV6006C
Optics Bench Divergence of Laser
Physics

Light Source

The Optics bench NV6006 is a versatile training system


designed to provide a comprehensive introduction to laboratory
optics. It is designed such that all the basics of light and optics
can be understood easily. This system includes an optics bench NV6006C Divergence of Laser is an Optical setup helpful to ¨
Sliding stand with precise measurement
setup with different lenses and mirrors. The Basic Experiments identify characteristic of Laser beam. This product illustrates
¨
Precise Voltage and Current measurement
provide all the essentials for a solid introduction to optics. The how the spreading of Laser beam enhances with respect to
distance traveled in a medium. NV6006C is consist of Optics ¨
Microcontroller based LCD
System is easy to use, affordable, and ruggedly designed. This
Optic Bench provides understanding about basic properties of Bench and Measurement unit. The Measurement unit consists ¨
Provided with DC supply
light such as Refraction, Reflection, Dispersion and Total Internal of variable DC power supply, voltage and current display. The
¨
e-Manual
Reflection etc. by the easiest way. Optics Bench consists of Laser source, Converging lens and
Photo detector with distance measurement arrangement. ¨
2 Year Warranty

Contents & Specifications ¨


Ideal System for performing many Experiments
Two Rods of 1meter length with two stands ¨
A comprehensive and self contained optics system
¨
A complete system with a light source, Bench and all Contents & Specifications Scope of Learning
Light Source
other accessories ¡
To determine the Divergence of Laser beam
150 watt Incandescent light source Optics bench
¨
Accessories are provided in a good quality carrying
Mains Supply : 230 V ±10%, 50 Hz Length : 1meter
case
Different Shapes of slits Laser source
¨
Extensive e-Manual
Converging and Diverging lens ¨
Provided with Learning Software Wavelength : 630 nm
Focal length : 100 mm, 150 mm Output : Less than 3mW
¨
2 Year Warranty
Diameter : 50 mm each
Convex Lens
Concave and Convex mirror
Focal length : 100 mm, 150 mm Type : Double Convex
Diameter : 50 mm each Scope of Learning Focal Length : 100, 150 mm
¡
To study the image formation of source
Plane Mirror Diameter : 50 mm
¡
Introduction of ray optics by ray tracing
Dimension (mm) : 100 × 75 × 2 Detector : Photodiode
¡
Verification of Reflection of light
D-Shape lens DC Power Supply : 0 - 5 V
¡
To determine Refractive index of semi circle (D-shape) lens by
Dimension (mm) : 100 × 50 × 20
Snell's law Mains : 230 V ±10%, 50 Hz Accessories
Prism ¡
Verification of Reversibility of light
Dimension (mm) : 50 × 50 equilateral Fuse : 0.5 A
¡
To determine critical angle and obtain Total Internal Reflection
Mirror Stand ¡
To study Dispersion of light
¡
To study Convergent and Divergent lens by image and object
Subject to Change

Subject to Change
Lens Stand
relationships
Ray Table
¡
To measure Focal Length of Convex lens using Basic Lens
Viewing Screen Equation
Two Optical Pins ¡
To measure magnification of image of Convex lens
¡
To determine Focal length of Concave mirror by two Pin method
¡
To determine Focal length of Convex lens by two Pin method
8 9
NV6006D NV6007
Inverse Square Law Fuel Cell Trainer
Physics

NV6007 Fuel Cell Trainer is a modular experimental system designed to


study the working of Solar-Hydrogen cycle. The Reversible Fuel Cell is
¨ Complete Training System to study the Solar-Hydrogen
unique, as it acts as both, an Electrolyzer and a Fuel Cell.
cycle
This trainer demonstrates Chemistry and Physics principles by
¨ Reversible Fuel Cell-both as an Electrolyzer and as a
experimenting with the splitting of water into its basic elements
Fuel Cell
(hydrogen and oxygen) using renewable power generation from
photovoltaic technology (solar panel), and then use this basic element ¨ Measurement and Application Modes
Inverse Square Law, NV6006D is an Optical setup for illustrating
(hydrogen) of water as a renewable “energy carrier” that can power ¨ Weather proof Solar Panel
how light intensity varies with distance. The inverse square law many applications with fuel cell technology. ¨ Portable and light weight
NV6007 provides an excellent opportunity to learn about the exciting ¨ Extensive e-Manual and study material
states that the illumination of a surface by a point source is prospects of renewable energy. Study how renewable energy can be ¨ 2 Year Warranty
inversely proportional to the square of the distance between the harnessed, stored and re-used in all kinds of applications and how Scope of Learning
hydrogen can be a unique link between natural resources of power and ¡
Study of Current-Voltage Characteristic of Electrolyzer function of
source and surface. NV6006D consist of Optics bench, Light power consuming devices-using fuel cell technology. Reversible PEM Fuel Cell
This system includes Solar Photovoltaic Panel, Hydrogen and Oxygen ¡
Study of Current-Voltage Characteristic and Power Curve of Fuel Cell
source and Photodetector. Storage Tanks, Reversible Fuel Cell and an Application Board function of the Reversible PEM Fuel Cell
encouraging users to learn the system step by step, configure the ¡
Study of the Application of Fuel Cell function of Reversible Fuel Cell
system and visualize the workings of clean energy principles from start of providing electrical energy to the loads such as buzzer, fan and
to finish. bulb

Technical Specifications
Solar Panel :
Voltage (at optimum power point) : 2.2 V DC
Current (at maximum power point) : 450 mA
Dimensions : 125 x 155 x 8 (mm)
Technical Specifications Note : Solar Panel data is based on standard conditions Solar Panel
¨
Sliding stand with precise measurement
(1000 W/m2, 250C)
Optics bench : Reversible Fuel Cell :
¨
Light Source with height adjustment
Length : ½ meter Dimensions : 54 × 54 ×
17 (mm)
¨
e-manual Light Source : Incandescent Lamp Total Weight : 69.7 grams
Wattage : 100W Electrolyzer Function :
¨
2 Year Warranty Input Voltage : 1.8 ~ 2.6 V DC
Detector : Photodiode
Input Current : = 0.7 A Reversible Fuel Cell and
Hydrogen Production Rate : 7 ml / min at 1A Gas Storage Tanks
Oxygen Production Rate : 3.5 ml / min at 1A
Fuel Cell Function :
Output Voltage : 0.9 V DC
Output Current : 360 mA
Subject to Change

Subject to Change
Scope of Learning
Power : 210 mW
¡Verification of Inverse Square Law Volume of Inner Containers for : 16ml
Hydrogen/Oxygen Gas Storage Application Board

10 11
NV6008 NV6012
Wind Energy Trainer Coulomb’s Law Demonstrator
Physics

NV6008 Wind Energy Trainer is a versatile training setup used in ¨


Complete setup to study the fundamentals of wind based
DC power generator Coulomb's Law Demonstrator, NV6012 is
the laboratories to understand the conversion of wind energy
an important setup to understand the
into electrical supply. It introduces the basic concept of wind ¨
Measurement and Application Modes conceptual aspect of Coulomb's law.
turbine, of converting kinetic energy of wind into mechanical Coulomb's law states that the force
¨
On board voltmeter and ammeter are provided
energy and then this mechanical energy into electrical energy. between two electrical charges is

Force (F)
¨
Charging the battery using wind energy as the generator proportional to the product of the charges,
The setup works as a live demonstration unit of wind turbine and
of DC supply
and inversely proportional to the square of the distance between
generator in terms of its concepts and applications. It is provided
¨
Portable and light weight them. Coulombic force is one of the principle force involved in
with a Wind Turbine Setup and Wind Energy Trainer.
atomic reactions. Coulomb's Law is applicable for Electric field,
¨
Strongly supported by systematic operating instructions
Gravitational field and Magnetic field. In this product Magnetic
with theoretical and practical details
Contents & Specifications force is used for Coulomb's Law Demonstration. A pair of
¨
Extensive e-Manual Magnets of constant and equal pole strength are mounted 0
Wind Turbine Setup : Contain 3 blades Distance (r 2 )
horizontally with varying distance. It allows the Inverse Square
¨
2 Year Warranty
Maximum Open Circuit Voltage : 3 V DC law to be verified with reasonable accuracy. A simple balance
Maximum Short Circuit Current : 250 mA DC
Scope of Learning
Voltmeter : 0 -10 V
¡
Calculation of voltage and current of wind energy based DC supply ¨
Easy way of Magnetic Force Demonstration Technical Specifications
with change in shape of blades.
Ammeter : 0 - 500 mA ¨
LED Indicator Magnets : Two
¡
Calculation of voltage and current of wind energy based DC supply Length : 4cm
Potentiometer : 5 K ¨
Infrared light detection for balancing
with change in angle of blades.
Type : Neodymium
AA Rechargeable : 1.2 V
¨
Complete Training Setup
¡
Calculation of voltage and current of wind energy based DC supply
NiCd Battery with change in direction of wind.
Balancing : By IR detection
¨
2 Year Warranty
Scale : 0 - 14 cm
Lamp : 3 V DC ¡
Calculation of voltage and current of wind energy based DC supply
with change in wind pressure. Adaptor Input : 220 - 240 V, 50 / 60 Hz, 12 W
Fan : 3 V DC Scope of Learning Adaptor Output : 6 V, 500 mA
¡
Application of wind energy based DC supply in domestic purposes :
FM Band Radio : 3 V DC ¡Verification of Coulomb's Law Dimensions (mm) : L 360 ´
B 255
a. Charging of batteries both on load and no load conditions.
Subject to Change

Subject to Change
b. Operating lamp, fan and FM receiver.

12 13
NV6021 NV6022
Half Shade Polarimeter Viscosity Measurement Apparatus
Physics

NV6021 Half Shade Polarimeter is a useful apparatus for Technical Specifications NV6022 Viscosity Measurement Apparatus demonstrates Technical Specifications
understanding the concept of polarization. With the help of half Polaroid : viscosity experiment and elicit the interest of students in the field Tube stand :
shade polarimeter, polarization can be studied as well as Thickness : 0.1 mm Base (cast iron) : 23 x15 sq.cm.
of fluid mechanics. This apparatus verifies Stokes law and helps Rod (mild steel) : 110 cm.
Diameter : 26 mm
analyzed. For better accuracy in determination of specific us to understand the motion of object inside the fluid. Here
Type : Nitrocellulose polymer
rotation, half shade polarimeter is used which involves Cylindrical tube:
“falling sphere” method is used to determine the viscosity of Length : 100 cm.
comparing the brightness of two halves in the field of view. The Half wave plate :
liquid. This method describes a general procedure for the Internal diameter : 3.5 cm.
Wavelength : 589 nm
apparatus is based on Biot's Law. When a plane polarized light is External diameter : 4.0 cm.
Type : Quartz determination of not only the viscosity but the density of liquid as Volume : 962 c.c.
passed through an optically active substance, the plane of
Objective lens : well. This activity enables us to observe the relative viscosity
polarization of light gets rotated. In order to find out the effect of Measurement Unit:
Type : Double Convex and density of liquids like glycerin, castor oil, mustard oil etc. Adaptor Input :100 - 240 V, 50 / 60 Hz
relative rotation between the polaroids on intensity of Focal length : 50 mm Adaptor Output : 5 V
transmitted light, we are using a half wave plate. Comparing the Our set-up covers both manual and automatic viscosity Timer checking time : 5 Sec.
Eye piece : determination. Time segments : 3
brightness of the two halves of half wave plate, one can easily Type : Double Convex
find out the optical rotation produced by an optically active Focal length : 200 mm Steel sphere :
Diameter :0.2 cm to 0.5 cm
substance in solution form.
Polarimeter tube : Density :7.85 gm / cm3
Length :100 mm(1dm) ¨
Out-let in bottom of tube provides easy replacement of
Material : Borosilicate Glass beads :
liquid and dipped spheres
Volume : 23 ml Diameter : .35 cm to .45cm
Density : 2.5 gm/cm3
¨
Sodium vapour lamp light source
Sodium vapour lamp : ¨
Measurement unit enables us to capture and store time
¨
Adjustable height Wavelength : 5893? readings, and gives instant result of viscosity
Wattage : 35W
¨
Circular scale graduated from 0° to 360°
Lamp has to be connected with provided external power supply. ¨
Centrally bored rubber cork provides same trajectory for
all spheres Scope of Learning
¨
Polarimeter borosilicate glass tube with bubble trapper
in the middle Scope of Learning n
To determine the co-efficient of viscosity of glycerin by falling
sphere method.
n
Determination of the specific rotation of sugar solution using Half ¨
Dipping bowls provide easy quenching of sphere, and
¨
Extensive e-Manual Shade Polarimeter. prevent any kind of mixing into each other n
To determine the density of given liquid using steel sphere, glass
beads.
n
Study of variation of angle of rotation of sugar solution with its
¨
2 Year Warranty
Subject to Change

Subject to Change
concentration. n
To predict the fall time of different size spheres of same material.
¨
Extensive e-Manual
n
Study of optical rotary dispersion of sugar solution or to
determine the dependence of angle of rotation of sugar solution
on the wavelength of light.

14 15
NV6023 NV6025
Malus Law Setup Planck's Constant Determination using LED
Physics

Malus law Setup NV6023 is a useful optics setup for students. It Technical Specifications NV6025 Planck's Constant Determination using LED is a useful Technical Specifications
establishes the transverse nature of light and based on the Digital ammeter Trainer which illustrates the basic concept of the Quantum Mains : 230V ±10%, 50 Hz
polarization of light. Incandescent lamp is used as light source to Range : 0 - 20 microampere
Mechanics. The trainer familiarizes with the concept of photon Fuse : 0.5A
study the phenomenon by direct vision as well as for intensity Mains supply : 9 V
energy and explains how it is related to its frequency. Trainer is DC Power Supply : 0-5V
measurement. With the help of this setup, both the basic laws of Detector : Photodiode
LED
polarization - Brewster's law and Malus law can be understood mainly designed to evaluate Planck's Constant. For this purpose
Type : Super bright
easily. The polarization can be studied by direct vision as well as Polaroid five different colors of LEDs are included with trainer. This trainer
Size : 5 mm
by reading the variation of intensity through a digital ammeter Diameter : 26mm facilitates to determine the Planck's Constant by measuring the Colours : Blue, Green, Orange, Red, Yellow
connected across a photodiode. Type : Nitrocellulose polymer film
voltage drop across LEDs.
The verification of Malus law particularly, can be done in three
DC Voltmeter
different ways using: two coaxial polaroids, two parallel plain Incandescent lamp
Type : LCD
glass plates and a combination of glass plate and polaroid. ¨
Self contained trainer requires no other accessory
Wattage : 40W
Display : 3½ digit
Input Mains supply : 230V ± 10%, 50Hz ¨
Super bright LEDs Range :200 mV- 200V

¨
LCD for current and voltage
¨
Comprises of fixed lamp arm, central circular glass Measuring scale : 0° - 360º
DC Ammeter
plate base and movable analyzer arm
¨
Variable DC Supply (0-5 Volt) Type : LCD

¨
Holders with adjustable height and circular scale Display : 3½ digit
¨
Extensive e-Manual
plates Scope of Learning Range :2µA- 200 mA
¨
2 Year Warranty
¨
Digital ammeter for precise reading n
Study the Polarization of light by reflection and thus verify the
Brewster's law.

¨
Graduated circular scale of analyzer n
Verify Malus law using a plain glass plate and a Polaroid.
Scope of Learning
n
Verify Malus law using two Polaroid.
¨
from 0° to 360° n
Determination of Planck's Constant using Light Emitting Diode
n
Verify Malus law using two plain glass plates. (LED). Vo
¨
Extensive e-Manual hc
n
Draw the I-V characteristic for Light Emitting Diode (LED) and Slope = e
Subject to Change

Subject to Change
hence determine the Threshold Voltage.
¨
2 Year Warranty
n
Determination of Planck's Constant by plotting curve between
Threshold Voltage and Wavelength of LEDs.
1

16 17
NV6026 NV6028
Moment of Inertia table Setup Fresnel Biprism Setup
Physics

Lamp & Scale Measurement Unit

NV6026 Moment of Inertia Table Setup dramatically represents Technical Specifications NV6028 Fresnel Biprism Setup illustrates about the phenomena Technical Specifications
how moment of inertia posses in any body. Moment of Inertia of interference of light. With the help of interference phenomena Optics bench :
Circular Base
Type : Iron we can find the wavelength of monochromatic light source like Length : 1.5 m
plays an important role in our daily life. Setup familiarizes with
Diameter: 25cm Laser, Sodium lamp etc. in a very easy manner. In this Laser source:
the concept of Moment of Inertia along with rotational motion of
Wavelength : 630 nm
Inertia Discs experiment students can understand the concept of
object. Setup explains how it is affected by mass and distance Output : Less than 3mW
Type : Aluminium interference, image formation and the width of fringes. Generally
Diameter : 15cm Biprism :
from the axis of rotation. Our setup allows to determine the the interference pattern is demonstrated by Young's Double Slit
Balancing ring : 04 Dimension : 50 x 40 mm
moment of inertia of various objects. For time measurement of experiment, but it couldn't explain the phenomenon of Material : Glass
Suspension Wire Refractive index : 1.5
rotation, measurement unit is included with manual and Type : M.S. Wire interference clearly to overcome this difficulty Fresnel Biprism
Convex Lens:
automatic mode. Width : 28 gauge was introduced.
Type : Double Convex
Auxiliary Body of known MOI Focal Length : 100 mm
Diameter : 50 mm
Cylindrical ¨
A comprehensive and self contained optics system
¨
Micro controller based Measurement Unit Radius : 1.9 cm
Concave Lens:
Type : Double Concave
Weight : 300 gm ¨
A complete system with a Light Source, Bench and all
Focal Length : 200 mm
¨
Engraved and ruled inertia discs other accessories
Lamp & Scale(Optional) Diameter : 75 mm
Lamp :Laser light source ¨
Sliding uprights are provided
¨
Inverted U- shaped metal body with chuck screw Scale : 30 - 0 - 30 cm
connection
¨
Laser as a Monochromatic source Scope of Learning
n
Determination of the wavelength of the monochromatic light with
¨
Measurement unit gives instant result of moment of ¨
Convex lens is used for focused image the help of Fresnel Biprism.
inertia
n
Determination of fringe width of the interference pattern.
Scope of Learning ¨
Concave lens for clear vision of fringes
n
Determination of the moment of inertia of given body using
¨
Three experimental bodies
inertia table. ¨
Extensive e-Manual
n
Determination of the moment of inertia of given body using
¨
Extensive e-Manual inertia table using lamp and scale arrangement. ¨
2 Year Warranty
Subject to Change

Subject to Change
n
Prove the perpendicular axis theorem of moment of inertia using
¨
2 Year Warranty inertia table.

Accessories

18 19
NV6029 NV6030
Nodal Slide Assembly Setup Carey Foster's Bridge Setup
Physics

NV6029 Nodal Slide Assembly Setup is an elite training unit to Technical Specifications NV6030 Carey Foster's Bridge Setup is used for the Technical Specifications
determine the focal length of convergent lens either individually measurement of very low resistances, although it can be used to Mains Supply : 230V AC ±10%, 50Hz
or in combination. The nodal slide is made available for the Optics bench : Fuse :0.5A
find small differences between large resistances. It can measure DC Power Supply : 3V
examination of images formed at a finite magnification, whether Length :1 m
the decimal value of resistance. Our Carey Foster's bridge Setup Variable resistance : 0-100 W
by visual examination, photography, by the introduction
Galvanometer :
between the fixed light source or object and the lens.This setup Light source : consists of two parts one is bridge arrangement and other one is
Deflection : 30-0-30
helps students to understand the basic property of lens like focal Output : 40W its testing unit. Testing unit contains DC power supply, Resistance : 80W
length, focus point, nodal point, principal axis, centre of Input : 220 V ±10%, 50Hz Wire :
Galvanometer and adjustable resistances on a single board. DC
curvature etc. Nodal slide assembly is very compatible Type : Constantan
arrangement, in which rotational and linear movement of the power supply solves the problem of discharging a battery or a Length : 1 m
Convex Lens :
carriage (on which two lens holder are fixed) is provided to cell with respect to time which affects the result. Sensitivity of SWG : 28
Type : Double Convex Diameter : 0.37 mm
check arrangement of optical bench. Carey Foster's bridge is the same as the sensitivity of the
Focal Length : 150 mm Resistance : 10W (2 Nos.)
¨
A comprehensive and self contained optics system Diameter : 50 mm Wheatstone bridge as it uses the same fundamental principle. Bridge scale : 0-100 cm
¨
A complete system with a Light Source, Bench and all Jockey : Copper
other accessories Nodal Slide Assembly :
¨
Sliding uprights Circular scale : 0 - 360° ¨
Precise Bridge arrangement Scope of Learning
Linear scale : 70 - 0 - 70 mm n
Measurement of low resistance using the Carey Foster's Bridge
¨
40W incandescent lamp Light Source
without calibrating the Bridge wire.
¨
Galvanometer, resistances and DC power supply are
¨
Extensive e-Manual n
Determination of the specific resistance of the Constantan wire
provided on a single board
using the Carey Foster's Bridge.
¨
2 Year Warranty
Scope of Learning n
Measurement of low resistance using the Carey Foster's Bridge
¨
Low temperature coefficient Constantan wire after calibrating the Bridge wire.
n
Determination of the focal length of the convergent lens.

n
Determination of the focal length of the combination of
¨
DC power supply in place of a cell or battery
convergent lenses.
¨
Extensive e-Manual
n
Verification of the relation.

1 1 1 d ¨
2 Year Warranty
+
F f1 f2 f1 f2
Subject to Change

Subject to Change
n
Determination of the principle points of the lens system

Accessories

20 21
NV6031 NV6032
Stefan's Law Trainer Calibration of Voltmeter and Ammeter
using Potentiometer
Physics

NV6031 Stefan's Law Trainer illustrates about the basic Technical Specifications NV6032 Calibration of Voltmeter and Ammeter by Potentiometer Technical Specifications
phenomenon of thermodynamics. The Trainer gives idea about is very useful setup to understand the functioning and calibration Analog Voltmeter : 0 - 10V
Voltmeter : 0 -10V
how energy loss depends on temperature. Stefan's Law states of Potentiometer, Voltmeter and Ammeter. It is a complete setup
Ammeter : 0 - 500mA Analog Ammeter : 0 - 1A
that the power radiated by a body is proportional to the 4th power with training board, Potentiometer and Calibration unit.
Bulb : Potentiometer Wire : Constantan
Calibration unit has a Voltmeter and an Ammeter, which can be
of the absolute temperature. The phenomenon can be studied Type : (Neon)
Calibrated by Potentiometer. A Potentiometer is an instrument Length : 10 meters
using a light-bulb filament used as radiating body. The power Operating Voltage : 12V DC
designed to measure an unknown voltage by comparing it with a
can be determined from the voltage and current of the filament. DC Supply (Standard) : 1.016 V
Variable Resistance : 1KW
known voltage. It has a high degree of accuracy. The
The temperature of the filament can be determined indirectly by Variable Resistance : 3 - Decade
Mains Supply : 230V AC ±10%, 50Hz potentiometer is used extensively for the calibration of
first computing the electrical resistance and then using a
Fuse : 500 mA voltmeters and ammeters, and provides a standard method for : X 0.1E, X 1E, X 10E
standard resistance versus temperature relationship.
calibration of these instruments. The potentiometer is used Voltage Ratio Factor : 0, 1.5, 15, 30, 150, 300
extensively for the calibration of voltmeters and ammeters, and
Total Resistance : 15K E
provides the standard method for calibration of these
Variable Supply : 0 - 12 V
instruments.
¨
Inbuilt Ammeter and Voltmeter Scope of Learning
Mains : 230 V ±10, 50 Hz
n
Verification of Stefan's law by electrical method.
Fuse : 0.5 A
¨
Variable DC supply ¨
Inbuilt meters
n
Study the temperature dependence of total radiation and hence
verify the Stefan's law.
¨
Easy to Operate ¨
Complete Setup requires no other accessories

¨
Designed with all Safety Precautions ¨
Compact design Scope of Learning

n
Study of Standardization of the DC Potentiometer
¨
Extensive e-Manual
¨
Extensive e-Manual
n
Calibration of Voltmeter using DC potentiometer
¨
2 Year Warranty n
Calibration of Ammeter using DC potentiometer
¨
2 Year Warranty
Subject to Change

Subject to Change
22 23
NV6034 NV6037
Current Carrying Coil Setup Desauty's and Schearing Bridge Trainer
Physics

NV6034 Current Carrying Coil Setup is useful to understand the NV6037 Desauty`s and Schearing Bridge Trainer is useful for Technical Specifications
concept of Electromagnetism. This product is also known as measuring very small value of Capacitance. By setting the null Sine Wave Generator :
Stewart and Gee apparatus. This setup is helpful for the study of point, we can evaluate the unknown capacitance. To set this Frequency range : Selectable
P Q
magnetic field around a current carrying coil. The setup point, null detector with amplifier circuit is implemented on 500 Hz
l to 1 KHz
illustrates how magnetic field generates by applying electric trainer board. NV6037 is based on the principle of Wheat Stone

Magnetic Field B
1 KHz to
l 10 KHz
current in any current carrying conductor. For this purpose Bridge. A Function Generator is provided for Frequency and
10 KHz
l to 60 KHz
Tangent Galvanometer is used, which is based on Tangent law of Amplitude variation. Null detector section includes differential
Amplitude control output :
magnetism. X'
amplifier, audio amplifier and speaker.
-X
O
+X Sine wave : Up to 8 Vpp
Distance Speaker : 8 Ohm
Display : LCD
¨
A complete setup with all accessories Technical Specifications ¨
A Complete set up with all necessaries accessories
Fuse : 500 mA, slow blow
¨
Precise Tangent Galvanometer Mains : 230 V AC ±10%, 50 Hz ¨
Inbuilt Function Generator
Mains : 230 V AC ±10%, 50 Hz
¨
Sliding Magnetometer DC Power Supply : 5 Volt, 2.6 A ¨
Microcontroller based Frequency Counter Unknown Capacitors : 0.1 ìF, 0.22 ìF, 0.47ìF
¨
Provided with DC power supply DC Ammeter : 0-3A ¨
Null detector with audio amplifier and speaker
Tangent Galvanometer
¨
Extensive e-Manual ¨
e-manual
Type : Stewart and Gee
¨
2 Year Warranty ¨
2 Year Warranty
Scale : 50 - 0 - 50 cm
Magnetometer
Pointer : Aluminium
Scope of Learning Quadrant : 0° - 90° (Four) Scope of Learning
¡
Determination of the radius of a current carrying coil Coil ¡
Determination of unknown capacitance using Desauty
Bridge method
¡
Determination of the magnetic field with the variation of Bobbin : Aluminium
distance along the axis of current carrying coil Diameter : 19 cm ¡
Determination of unknown capacitance using Schearing
Bridge method
¡
Verification of Biot Savart's Law Wire : Insulated copper
Subject to Change

Subject to Change
Turns : 0 to 5, 50, 100, 200, 500

24 25
NV6040 NV6041
Young's Modulus Setup Post Office Box Trainer
Physics

NV6040 Young's Modulus Setup is a complete system used to Technical Specifications NV6041 Post Office Box Trainer is the combination of Technical Specifications
determine Young's Modulus of Elasticity of materials. When a resistances which work on the principle of Wheatstone Bridge.
metal wire is stretched beyond its elastic limit then its cross Sample 1 : Post Office Box is helpful to determine the unknown resistance Mains : 230 V AC ± 10%, 50 Hz
section is reduced i.e. its structure is changed internally. These Material : Iron of wires like Constantan, and Nichrome etc. With the help of Fuse : 500 mA
changes increase with repeated drawings. The hardness and Length : 100 cm NV6041 we can determine the specific resistance of different DC Power Supply : 5V
elasticity of the material are profoundly affected. Setup is used to Breadth : 2.5 cm types of wire. Post Office Box can also verify the combination of
investigate the change in length of a sample under a varying Depth : 0.6 cm resistances in series and parallel. Galvanometer
tension. Sample 2 : Deflection : 30 – 0 – 30
Material : Brass Resistance : 80 W
Length : 100 cm
Precise measurement by Spherometer
¨ Breadth : 2.6 cm Sample : Constantan, Nichrome
¨
Unknown Resistance
Self-contained and easy to operate
¨ Depth : 0.5 cm Provided with DC power supply
¨ Type : Variable
Buzzer indicator
¨ Sample 3 : Compact design
¨ Range : 0 – 10 KW
Samples – Aluminium, Brass, and Iron
¨ Material : Aluminium Easy to operate
¨
Length : 100 cm Wire Samples :
A complete setup with stand, weights and different
¨ e-Manual
¨
samples Breadth : 2.55 cm Constantan : 1 meter
2 Year Warranty
¨
e-Manual
¨ Depth : 0.5 cm Nichrome : 1 meter
Weight (6 nos.) : 500 gm
Spherometer :
Main scale : 10 - 0 - 10 mm
Circular scale : 100 divisions
Scope of Learning Scope of Learning
Least Count : 0.01mm
¡
Determination of Young's Modulus of Elasticity of the given Power Supply : 230 V +10%, 50 Hz ¡
Determination of unknown resistance
samples by bending.
Adaptor Output : 12 V DC ¡
Determination of resistivity of the material of wire
Subject to Change

Subject to Change
¡
Verification of effects of resistances in series and parallel

26 27
NV6042 NV6043
Resloving Power of Telescope Thermal Expansion Trainer
Physics

NV6043 Thermal Expansion Trainer (Pullinger's Apparatus) Technical Specifications


illustrates the concept of conduction of heat in solids. With the Steam jacket
Resolving Power of Telescope NV6042 helps students to ¨
Provided with variable rectangular slit help of this product one can understand how Linear Thermal Type : Brass
understand the fundamental principle of Telescope. Telescope expansion occurs in solids. Pullinger's Apparatus is used to
¨
Crosswire- Eyepiece Length : 50 cm
used to gather and focus light. A Telescope with better resolving determine Coefficient of Linear Expansion of a given sample.
¨
Wide aperture optics Diameter : Inner 2.5 cm
power will reveal smaller surface features on the surface of the Thermal Expansion Coefficient is a thermodynamic property of
¨
Rack and pinion arrangement focusing Outer 3 cm
Moon or a planet. If a Telescope has good resolving power, then a substance or we can say Thermal Expansion is the tendency of
¨
Sodium Lamp as Monochromatic Light Source Sample
magnifying the image can be seen with fine details. Resolving matter to change in volume in response to a change in
(Optional) Type : Copper, Steel, Aluminium
Power of Telescope is the ability to see really small details so temperature
¨
Durable and precise construction Length : 52 cm
objects that are close together in the sky are easily seen as
¨
e-Manual Diameter : 10 mm
separate. The resolving power of a Telescope is indirectly related
to the diameter of the main mirror or lens. However it is limited by ¨
2 Year Warranty Spherometer
¨
Precise measurement by Spherometer
the Earth's atmosphere. Large Telescopes do not have better Main Scale : 10 - 0 - 10 mm
¨
For heating Electric Oven is provided
resolving power than modest size Telescopes. Circular Scale : 100 divisions
¨
Buzzer indicator
Least Count : 0.01 mm
¨
Samples for study– Copper, Brass, Aluminum Buzzer indicator : 1.5 - 15 V DC
Technical Specifications Scope of Learning ¨
Self- contained and easy to operate Power Supply : 230 V ±10%, 50 Hz
Slit : ¡
To determine Resolving Power of a Telescope
¨
e-Manual Adaptor Output : 5 V, 500 mA
Stripes Width : 1 mm
Separation between Stripes : 1 mm, 2 mm, 5 mm ¨
2 Year Warranty
Variable Rectangular Slit :
Main scale : 5 mm
Circular scale : 50 divisions
Least Count : 0.02 mm
Scope of Learning
Eyepiece : 10X(Ramsden)
Sodium vapor lamp : ¡
To determine the co-efficient of Linear Expansion of a given
Wavelength : 5893? Sample
Subject to Change

Subject to Change
Mains Supply : 230 V ± 10%, 50Hz
¡
Comparison of the coefficient of thermal expansion of
Wattage : 35 W
given samples of material & verification of
α copper <
αbrass <α aluminium

28 29
NV6045 NV6050
Ray Optics Study Setup Boyle’s Law Demonstrator
Physics

Boyle's Law Demonstrator, NV6050 helps students to


understand the relation between Pressure and Volume. Gas
laws are basics laws that give the relation between the three
basic properties of gas like Temperature, Pressure and Volume.
The NVIS Ray Optics Study Setup, NV6045 is designed to Technical Specifications
Robert Boyle stated that the volume of a fixed mass of ideal gas
provide a comprehensive introduction to laboratory optics.
Laser source at constant temperature is inversely proportional to the gas
Optics is a branch of physics that describes the behavior and
Wavelength : 630 nm pressure. All other laws are derived from ideal gas equation like
properties of Light and the interaction of light with matter. We Pressure
Output : Less than 3mW Charle's Law, Gay-Lussac's law, Avagadro's law etc. The
interact with light that has interacted with objects to determine
D-Shape Lens experiment will help students to understand the Ideal Gas law :
such things as the color, shape, and position of the objects. In
Material : Acrylic PV = nRT
studying optics we still gain our information by interacting with
light that has interacted with objects. But in studying optics we Ray Table : Four Quadrants of 90°
want to know more about optical properties like Reflection,
¨
Large syringe for Accurate Volume Measurement Volume
Refraction, Diffraction, Inference. NV6045 is designed such that
all the basics of light and optics can be understood easily. This ¨
High quality Pressure Gauge
product is supplied with Laser light source and Ray table scale ¨
2 Year Warranty
for measurement of different parameters.

Pressure Gauge : 0 - 2.1 kg/cm2 Scope of Learning


Syringe : 0 - 50 ml ¡Verification of Boyle's Law
¨
Laser light source Scope of Learning
Dimensions (mm) : L 265 ´
B 175
¨
Ray table for measurement ¡Verification of Reflection of Light
¨
e-Manual ¡Verification of Refraction of Light
¨
2 Year Warranty ¡Total Internal Reflection Demonstration
Subject to Change

Subject to Change
30 31
NV6101 Technical Specifications

Hall Effect Trainer NV621


Gauss & Tesla Meter
Microcontroller Based LCD screen for Measurement of Magnetic Field in
Gauss and Tesla, with PC Interface facility.
Sensor : InAs for better sensitivity
Range : 0 - 20 K Gauss
Indicates the direction of the magnetic field
Resolution : 1 Gauss
Mains Supply : 230 V ±10 %, 50 Hz
Dimension (mm) : W 198 × D 285 × H 90
Physics

NV622
Measurement Unit
a) Measurement of probe current and hall voltage
The Hall Effect Trainer NV6101 is a very useful system for the Digital Display : 0 - 200 mV
laboratory. It is used for the study of Hall Effect and its Current : 0 - 20 mA
Accuracy : 0.2 % of the reading 1 of digit
measurement. The Hall Effect is an important observation in
Load Regulation : 0.03 % for 0 to full load
material science. If an electric current flows through a conductor b) Measurement of Thermo emf and heater current - Digital Display
in a magnetic field, it exerts a transverse force on the moving 0 - 20 mV (100 microvolt Min.)
charge carriers which tends to push them to one side of the Accuracy : 0.1 % of reading 1 digit
conductor. It will balance this magnetic influence and producing Current : 0 - 1 A
Accuracy : ± 0.2 % of the reading 1 of digit
a measurable voltage between two sides of the conductor. This c) Hall probe
voltage is called as Hall voltage. Crystal : P - type lightly dopped
Resistivity : 6 - 7 ohm.cm
This system is provided with Gauss and Tesla meter with an InAs
Thickness : 0.50 mm 2 %
sensor for measurement of magnetic field. Measurement unit is d) Oven
given for measuring Hall voltage, probe current, heater current Maximum constant current : 750 mA
and thermo-emf. Constant current power supply is provided Maximum temperature : 90OC
for electromagnet which produces the magnetic field. This e) Temperature sensor
Temperature is measured with Chromel-Alumel thermocouple with its
trainer can be used to calculate the carrier density, mobility of junction at a distance of 1mm from the crystal.
charge carrier, Hall coefficient of given semiconductor material Thermocouple : Chromel-Alumel (Thermo e.m.f. chart is provided)
etc. We can study the effect of temperature in semiconductor f) Mains Supply : 230 V ±10 %, 50 Hz
material and relation between magnetic field and Hall voltage. g) Dimension (mm) : W 262 × D 316 × H 130

Setup consist of the following equipments :


Gauss & Tesla Meter NV621
?
Measurement Unit NV622
?
NV623
Constant Current Power Supply NV623
? Constant current Power Supply
Electromagnet
? Current range : 0 to 3.5 A
Hall probe with Oven and Thermocouple
? Output Voltage : 40 V
Display : 3½ digit, 7 segment
¨
A complete setup for the study of Hall Effect in Scope of Learning
Mains Supply : 230 V ±10 %, 50Hz
semiconductor ¡
Measure the magnetic field by Gauss and Tesla meter Dimension (mm) : W 262 × D 316 × H 130
¨
A Hall Effect probe is provided with p type germanium ¡
Find the poles of an electromagnet with the help of Hall probe
crystal with oven and Gauss meter
¨
Provided with InAs sensor for measuring magnetic field ¡
Measurement of Hall voltage
Electromagnet
¨
Gauss and Tesla meter for measuring magnetic field with Poles : 25 mm diameter
¡
Calculate the charge carrier concentration (density) of
LCD and PC interface facility semiconductor crystal Coils : 2 Nos.
Subject to Change

Subject to Change
Resistance : 2.2 Ohms (approx.)
¨
A thermocouple is provided for thermo-emf ¡
Calculate the Hall coefficient of Ge 'p' type crystal
Yoke : U shaped soft iron material
measurement ¡
Calculate the mobility of charge carrier particles
Input voltage : 40 V, 3.5 A
¨
Provided with an Electromagnet ¡
Study the Hall voltage as a function of current at constant
Weight : 16 Kg (approx)
¨
Provided with the power supply unit for an magnetic field
Dimension (mm) : W 400 × D 215 × H 235
electromagnet ¡
Study the Hall voltage as a function of magnetic filed at constant
current
¨
Extensive e-Manual
¡
Study the dependence of Hall Effect coefficient on temperature
¨
2 Year Warranty
32 33
NV6102 NV6103
Measurement of susceptibility of paramagnetic e/m measurement setup
solution (Quinck's Tube Method)

Deflection
Magnetometer
Power Supply
and measurement unit
Physics

Stand

CRT

NV6102 Measurement of susceptibility of paramagnetic Technical Specifications Nvis Model NV6103 e/m measurement setup is a very useful for Technical Specifications
solution is a laboratory setup to measure susceptibility of Physics and Basic Science Laboratories. This is used to find the
1. Quinck's Tube
paramagnetic solution by Quinck's tube Method. Susceptibility It is a U-shaped glass tube. One of the limbs of the tube is wide and Cathode Ray Tube:
specific charge density of a electron particle in a CRT by
refers to that quantity of a substance by virtue of which the the other one is narrow. Wide limb of the tube is fitted with the stand.
substance get magnetized. In other words, it refers to the extent 2. Paramagnetic samples Thomson method using BAR magnet. This system provided Distance between Plates d=0.3 cm
of induced magnetization in unit field. On the basis of It includes with two paramagnetic material one is Ferric Chloride with a power supply unit for CRT and Deflection Magnetometer
(Fecl3) and other is Mangnese Sulphate (MnSo4). Length of Plates l =2 cm
Susceptibility a substance can be classified as diamagnetic, with stand arrangement and mounting stand for CRT. NV6103
3. Electromagnet :
paramagnetic and ferromagnetic substance, which is an Poles : 25 mm diameter have a microcontroller based instrument with LCD display for Distance between Screen and Plates (edge) L =14.5 cm
important observation in material science. Coils : 2 No. displaying deflection voltage. It is highly secure and stable Focusing Voltage : Variable 0 to 300 V DC
Resistance : 2.2 Ohms (approx.)
Setup Consist of the following equipments : system.
Yoke : U shaped soft iron material Intensity Adjustment Voltage : Variable 0 to 60 V DC
l Quinck's tube with stand Input voltage : 40 V, 3.5 A
l Electromagnet Weight : 16 Kg Deflection Voltage : Variable 0 to 50 Volt
l Travelling Microscope (optional) Dimension (mm) : W 400 × D 215 × H 235 ¨
Microcontroller based power supply instrument for CRT
l Gauss and Tesla Meter NV621 with InAs probe 4. Constant current power supply NV623 Scale : 0 to 30 cm each side
l Constant current power supply NV623 Current range : 0 to 3.5 A
Output Voltage : 40 V
¨
LCD to measure deflection voltage CRT Connection :By Octal socket
l Paramagnetic sample
Display : 3½ digit, 7 segment
Mains : 230 V, ±10% ¨
Focusing adjustment provided LCD :16×
2
¨
Quink's tube is provided with measuring scale Dimension (mm) : W 262 × D 316 × H 130
5. Gauss and Tesla meter NV621 ¨
Intensity adjustment provided Deflection Magnetometer : 0 to 360°
¨
Provided with a magnifying lens Microcontroller Based LCD Display For Measurement of Magnetic
¨
Gauss and Tesla meter for measuring magnetic field Field in Gauss and Tesla, With PC Interface facility. It can indicate ¨
Cathode Ray Tube mounting on acrylic stand Mains Supply : 230 V ± 10%, 50Hz
with LCD and PC interface facility the direction of the magnetic field.
Sensor : InAs for better sensitivity Fuse : 500 mA
¨
InAs Probe for better sensitivity of magnetic field ¨
Deflection magnetometer provided
Range : 0 - 20 Kg
¨
Provided with an Electromagnet Dimension of Power Supply (mm.) : W 215 ×
D 195 ×
H 130
Indicate the direction of the magnetic field ¨
Octal socket provided on the front panel of power supply
¨
Provided with the Constant Current Power Supply for Mains Supply : 230 V ±10%, 50Hz for connecting CRT
an Electromagnet Hall probe Crystal : P- type lightly dopped
Resistivity : 6 - 7 ohm.cm ¨
Provided with Pair of bar magnet and Compass Box
¨
Extensive e-Manual
Thickness : 0.50 mm 2%
¨
2 Year Warranty Dimension (mm) : W 198 × D 285 × H 90
¨
Extensive e-Manual
Travelling Microscope (optional)
Subject to Change

Subject to Change
Scope of Learning Optics : True achromatic objective with 75mm focusing distance
¨
2 Year warranty
10X Ramsden eyepiece with fine cross wire
Measurement of susceptibility of Ferric Chloride (Fecl3)
n Scale :
Paramagnetic solution Horizontal scale : 20 cm divided at 0.5 mm interval
Measurement of susceptibility of Mangnese Sulphate
n Vertical scale : 14 cm divided at 0.5 mm interval
(MnSo4) Paramagnetic solution Vernier scale : 50 division with a least count of 0.01 mm

34 35
NV6104 NV6105
Newton's Ring apparatus Resistivity & Band gap Measurement
(Four Probe method)
Physics

NV6104 Newton' s ring apparatus is one of the basic experiment Technical Specifications Nvis Resistivity and Band gap measurement of Semiconductor Technical Specifications
at graduation level. With the help of this apparatus, the wave is a versatile and useful system for Physics and Basic
Sodium Vapour Lamp : Four probe :
nature of light is confirmed. It is based on the phenomenon of Wavelength : 5893Å Electronics Laboratories. In NV6105, we can find Band gap by Contacts with sample : spring loaded
interference of light waves obtained from single coherent (of Mains Supply : 230 V ± 10%, 50Hz using four probe method. This is one of the widely used method Space between probes : 2 mm ±2%
same frequency and constant or zero phase difference). The Operating Wattage : 35W
for measurement of Resistivity and Band gap of semiconductor. Probes : Collinear
phenomenon of Newton's ring, is the result of interference Lens : Sample
A collinear four probe arrangement has been used. In this
between the partially reflected and partially transmitted rays Type : Plano - convex
system, we provide the pressure contacts with sample to take Material : Germanium crystal
from both the lower curved surface of plano-convex lens as well Focal Length : 100 cm
Type : n-type
Diameter : 6 cm quick measurement on a different position. Using this method
as upper surfaces of the glass plate. When viewed with a Thickness : 0.50 mm.
monochromatic light, it appears as a series of concentric, Newton's Ring Microscope : we can reduce error in measurement of Band gap and
Oven
Magnification : 30 X Resistivity.
alternating bright and dark rings centered at the point of contact Maximum Temperature : Room Temperature to 200°C (max)
Weight : 5.7 Kg
between the two surfaces. The thickness of the film is radially Horizontal Movement Limit : 9 cm Heater Resistance : 37ohms (approx.)
symmetrical and increases outwards from the point of contact. Least Count of Circular Scale : 0.001cm ¨
A complete setup for measurement of Resistivity & Maximum heater Voltage : 45V
By studying the ring pattern, we can determine the wavelength of Dimensions : 5” x 3” x 3” Band gap Measurement Unit
the monochromatic light and also the refractive index of a given Digital Voltage measurement :
¨
Four individually spring loaded probe arrangement is
transparent liquid medium present in the wedge - shaped film. provided Display : 3½ digit, with auto polarity
Scope of Learning
Range : X1(0-200mV) and X10(0-2V)
n
Determination of the Wavelength of sodium light by measuring the
¨
Collinear and equally spaced probe Resolution :100mV at X1 range
¨
A microscope with x-y-z axes movement diameters of Newton's rings.
Constant Current Generator :
n
Determination of the Refractive Index of a liquid transparent ¨
The probes are mounted in a Teflon bush, which
¨
Horizontal measurement scale with fine and coarse Current Range : 0 to 20mA
medium such as water using Newton's ring apparatus. ensure a good electrical insulation between the probes
movement screw Resolution : 1mA
Accuracy : ±0.25% or ±1 digit
¨
Cross wire in the field of view for ring's diameter ¨
Germanium crystal in the form of a chip is provided
Open Circuit Voltage : 18V
measurement
¨
Oven arrangement with safety precaution Oven Mains Supply :
¨
Newton's ring assembly consisting of plano-convex Input : 230VAC ± 10%
lens mounted on an optically plane glass plate ¨
Provision for low and high rates of heating Heating Options :
¨
Adjustable plane glass plate is provided to be inclined a) Low : 40V AC b) High : 45V AC
¨
Extensive e-Manual
at 45º with respect to the vertical plain Temperature Measurement :
Subject to Change

Subject to Change
¨
2 Year Warranty Mercury Thermometer Range : 0 -150 °C
¨
Sodium vapour lamp as the monochromatic (5893Å)
and broad light source

¨
Extensive e-Manual

¨
2 Year Warranty Newton's Ring Microscope

36 37
NV6106 NV6107
Semiconductor Energy Band-Gap Ballistic Galvanometer Setup
Measurement Trainer
Physics

NV6106 Semiconductor Energy Band-Gap Measurement Technical Specifications NV6107 Ballistic Galvanometer Setup illustrates fundamental Technical Specifications
Trainer introduces you to a very useful nonlinear electronic information about electromagnetic induction. It concerns “how Ballistic Galvanometer
DC Power Supply
device: “diode”. This trainer familiarizes the characterstic and electric field affects magnetic field and also reveals the Suspension Wire : Phosphor Bronze
+ 15 V, 2.5 A
the energy band gap of Germanium semiconductor diode. + 5 V, 2.6 A mechanism of current sensing devices”. Ballistic Galvanometer Reflector : Concave Mirror

Semiconductor diode is an important element of most electronic Diode setup enables not only to detect weak electric field but as well as Coil Resistance : 100 ohm
O A79 P - N junction Lamp & Scale
devices and play an essential role in modern technology, to measures it very precisely. Ballistic power supply is included
Germanium Type Lamp : Laser Light Source
because of its relevant conductivity. This trainer provides the with setup, in which we can generate very weak ambient electric
Switch Scale : 30-0-30 cm
crucial framework, which needed to understand the concept of 1 Pole, 2 Ways
field and can reveal this effect to the Ballistic Galvanometer as a
Ballistic Galvanometer Mains Supply
an energy band gap and characteristic of a diode. Conductivity is Toggle Type detected deflection of coil. Lamp and scale arrangement is Supply Voltage : 6V
directly related to energy bands and it is necessary for any Display included for measurement of deflection. Potentiometer : 5KW
detailed description of semiconductor devices. The trainer is Type : LCD Mains : 230 V ± 10%, 50 Hz
Oven
based upon reverse diode characteristic, in which conductivity Fuse : 0.5A
Height : 77 mm ¨
Power Supply for Ballistic Galvanometer
depends on temperature. Width : 74 mm
Scope of Learning
Coil : Nichrome Wire ¨
Moving Coil with large Moment of Inertia
n
Determination of Ballistic constant by steady deflection method.
Fuse : 0.5A
¨
Designed with all safety standards
Mains : 90 - 275 V, 50 / 60 Hz ¨
Flexible Phosphor-Bronze Ribbon Suspension n
Determination of Charge sensitivity of Ballistic Galvanometer
using capacitors.
¨
Easy understanding circuit arrangement, with diagram Dimensions (mm) : W 250 ´
D 130 ´
H 30
¨
Highly Sensitive Coil n
Comparing capacitance of two condenser using Ballistic
interpretation.
Galvanometer.
¨
Lamp and Scale Arrangement with Adjustable Stand
¨
Onboard voltage and current measurement. n
Study the logarithmic decrement for a Ballistic Galvanometer.

¨
Deflection Measurement Scale
¨
Extensive e-Manual
¨
Extensive e-Manual
¨
PC Interface
¨
2 Year Warranty
Subject to Change

Subject to Change
Software Window

38 39
NV6108 NV6109
Hysteresis Loop Tracer Ultrasonic Measurement Lab
Physics

The Hysteresis Loop Tracer NV6108 is a versatile training Technical Specifications


system for the physics laboratories.This trainer is useful in
Display : 3 ½ digit NV6109 Ultrasonic Measurement Lab is a very useful training Technical Specifications
understanding the basic concepts and fundamentals of
Mains Supply : 230 V ±10%, 50Hz system for studying the various parameters of ultrasonic wave,
hysteresis loss in ferromagnetic substances.A precise Ultrasonic Interferometer
like velocity and distance measurement. With the help of this
knowledge of various magnetic parameters of ferromagnetic Sample :
setup, we can determine the velocity of ultrasonic wave in liquid Quartz Crystal
substances, i.e coercivity, retentivity, saturation magnetisation , Type : Soft Iron
with a high degree of accuracy. NV6109 consists of two parts – Diameter : 20 / 14 mm
hysteresis loss, and ability to determine these parameters
Length : 39 mm each one is training board and other is liquid cell. The training board
accurately are important aspects of magnetic studies.The Thickness : 1.4 mm
Diameter : 1.2 mm each contains Ultrasonic sensors, used for distance measurement
present set-up can accept the samples of different Frequency : 2 MHz
and object detection.
ferromagnetic substances and diameter. The demagnetisation Diameter of pickup coil : 3.21mm
Liquid Cell
effects and different samples has been taken into account
Optimum Quantity of Liquid : 12 cc
within the design. The equipment is complete in all aspects,
including a set of samples. ¨
Liquid Cell for Velocity Measurement Max. Displacement : 25mm of the Reflector
¨
Microcontroller based LCD Least Count of Micrometer : 0.01 mm
¨
Display of magnetic field in gauss Scope of Learning ¨
Ultrasonic Transducers as a Distance Meter Distance Measurement :
¨
Variable magnetic field ¨
Ultrasonic Transducers as a Object Detector
Understanding the following magnetic parameters and their Ultrasonic Transducer : 28 cm to 1.0 m (approximately)
¨
A good quality solenoid coil measurement by this set up: ¨
Precise Signal Conditioning
Clock Generator : 40 kHz
¨
Extensive e-Manual ¨
Self-contained and easy to operate
n
Corecivity Amplifier : 60 dB
¨
2 Year Warranty ¨
e-Manual
n
Retentivity Threshold Detector : 0 to 9 V DC

n
Buzzer Indicator : 1.5 - 15 V DC
Saturation magnetisation Scope of Learning
Power Supply : 230 V ± 10%, 50 Hz
Degree of n
Various magnetic phase identification
Saturation n
Study of Characteristic of Ultrasound
magnetization D Fuse : 500 mA
of tape or disc n
Hysteresis loss n
Measurement of the Distance using Ultrasonic Sensors Display : LCD
n
Study of Object Detection using Ultrasonic Sensors
Strength of
magnetizing
n
Determination of the Velocity of Ultrasonic Waves in a non-
C signal
electrolytic Liquid by Ultrasonic Interferometer
Subject to Change

Subject to Change
Input signal

n
Determination of the Compressibility of a non-electrolytic Liquid
by Ultrasonic Interferometer
Saturation

B-H Curve

40 41
NV6110 Light Sources Technical Specifications
Measurement of Wavelength of
Laser by Diffraction Grating

Diffraction Screen
Grating Light source is essential for any optics system. With a good
NV651
Laser Incandescent light source
Source spectral light source, students can investigate energy levels
Mains Supply : 230 V ±10%, 50 Hz
using spectrometer. In laboratory work generally artificial light Output Power : 150 W
sources are used, necessary for understanding the behaviour of
Physics

optics phenomena. NVIS light sources are the toughest, most

reliable light sources available for the laboratories, providing

high intensity spectral light.

NV652
Mercury light source
Na

Mains supply : 230V ± 10%, 50 Hz 653

NV6110 Measurement of Wavelength of Laser by ¨


A comprehensive and self contained Optics System Output Power : 160 W
Diffraction Grating is an Optical setup for understanding Wavelength : 400 - 800 nm
¨
A complete system with Light Source, Bench and all
the working of Diffraction grating and to determine the
necessary accessories
wavelength of Laser light. Where a Laser is used as a
Monochromatic Light Source and a Diffraction grating for ¨
Sliding stand for precise arrangement
getting a diffraction pattern.
Interference and Diffraction are the main phenomena
¨
2 Year Warranty
NV653
which demonstrate the wave nature of the light. ¨
Designed considering all safety standards Sodium light source
Diffraction grating allows a beam of light to be resolved Wavelength : 5893?
into different colors. It usually consists of thousands of ¨
Provided with a slit mask for different slit-plates This light source requires a special
narrow, closely spaced parallel slits (or grooves). power supply. Connecting directly to
the mains, may damage the Lamp.
With the help of this setup we can find out the wavelength ¨
Holes are provided to exhaust the hot air
of any intense Monochromatic light.
Technical Specifications Sodium vapour lamp
¨
Easy to operate Mains supply :
Optics bench
Mains supply : 230 V ± 10%, 50Hz
Length : 1 meter
¨
Inbuilt cooling fan is provided for halogen lamp Operating wattage : 35W
Laser source
Wavelength : 630 nm
¨
Extensive e-Manual
Output : Less than 3 mW
Diffraction Pattern
Diffraction Grating : 300 L / mm or
600 L /mm or
NV654
15000 L / inch Laser source
Scale Laser source NV654 :
Horizontal : 10 - 0 - 10 cm Wavelength : 630 nm
Subject to Change

Subject to Change
Vertical : 9 - 0 - 9 cm Output : Less than 3mW

42 43
NV656 NV657
Spectrometer Set-up Travelling Microscope
Physics

NV656 Spectrometer Set-Up is useful for understanding the ¨


A complete setup with all necessary items
behaviour of light and it concerns the phenomena of Reflection, ¨
Adjustment of entrance slit is provided
Refraction, Diffraction and Interference of light. Optical ¨
Prism table for accurate component placement Travelling Microscope, NV657 is extensively used in Research, Technical Specifications
spectrums are important for any detailed description of light
source and wavelength determination for each colour of light. ¨
Crosswire - Eyepiece Colleges, Schools and Industrial laboratories for accurate
Base : Iron
Spectrometer is basically an instrument for observing ¨
Wide aperture optics measurement of the diameters of different objects. Two slow
spectrums and measuring angle of deviation of light in a ¨
Rack and pinion arrangement focusing motion knobs are provided for taking accurate readings. For Scale : Stainless Steel
particular medium, for mathematical calculations. Set-Up ¨
Durable and precise construction placing objects on horizontal stage, milky cenolite sheet is
comprises of spectrometer, prisms, grating and light source, Vertical Scale
provided on the base. The position of the Microscope can be
which are necessary for all the basic experiments of
spectrometer. varied coarsely by sliding along the rails, or finely by turning a Main Scale : 0 - 150 mm
screw. The microscope is focused by rack and pinion and has
Technical Specifications : Scope of Learning Vernier Scale : 0 - 1 mm
achromatic objective of 50 mm focal length and eye piece with
Base: cross line graticule. Least Count : 0.01 mm
To determine the Wavelength of main spectral line of
?
Type : Cast iron mercury light using plane transmission grating and
Circle dia : 150 mm. (6”) Horizontal Scale :
spectrometer.
Purpose of the microscope is to aim at reference marks with
Scale : Main Scale : 0 - 180 mm
To determine the Refracting Angle of prism using
? much higher accuracy compared with bare eyes .It is used in
Type : Stainless Steel spectrometer. labs to measure refractive index of liquids using the geometrical Vernier Scale : 0 - 1 mm
Main scale : 0 - 360°
Vernier scale : 30 div To determine the Refractive Index and Dispersive Power of
? concepts of ray optics. It is also used for more accurate
prism using spectrometer. determination of small variation in the liquid levels, the refractive Least Count : 0.01 mm
Collimator :
To determine the Refractive Index of transparent liquid like
? index of liquids as well as in surface tension & diameter of Eyepiece : 10 X (Ramsden)
Tube length : 160 mm.
Focal length of water using a hollow prism and spectrometer. capillary tubes with precision.
Achromatic lens : 175 mm. (approx.) To draw a graph between the Angle of Minimum Deviation d
? m

Telescope : and wavelength l


, for different colours of light using
Tube length : 185 mm. spectrometer. ¨
Wide Aperture Optics
Focal length of ¨
Accurate and precise arrangement
To plot a graph between Angle of Incidence and
?
Achromatic lens : 175 mm. (approx.) corresponding Angle of Deviation using prism and
¨
Magnifying lens for reading
Prism spectrometer.
Geometry : 50 × 50 mm. equilateral ¨
Rack and pinion arrangement focusing
To draw a graph between the Refractive Index m
? and
Refractive index : 1.51 Wavelength l for different colour of light and to verify ¨
2 Year Warranty
Subject to Change

Subject to Change
Hollow prism : 50 × 50 mm. equilateral Cauchy's formula.
¨
Extensive e-Manual
Plane transmission grating : 15,000 L/inch or 300 L/mm
Light source : Mercury lamp

44 45
NV660 NV4500
Set of Polarizers Introductory Nano Kit

Nanotechnology
Shape Memory Alloy Demonstrator
Physics

NV660 Set of Polarizers consist of identical units one is Technical Specifications

Polarizer and other is Analyzer. A polarizer is a device that Circular Scale : SPM Concept Demonstrator

converts an unpolarized or mixed-polarization beam of Range : 0° - 360°

electromagnetic waves (e.g. light) into a beam with a single


Least Count : 1°
NV4500 Introductory Nano Kit is a fundamental kit to ¨
Easy to comprehend
polarization state (usually, a single linear polarization). understand the basic concepts of Nano technology right from
Diameter : 79 mm ¨
Laser pointer is provided for clear vision of diffraction
Polarizers are used in many optical techniques and instruments, the scaling to the characteristics at Nano level. pattern
Type : Brass
and polarizing filters find applications in photography and Liquid Nanoscale Science, Engineering, and Technology are fields of ¨
Diffraction slide with different types of pattern is
Polaroid : research in which scientists and engineers are manipulating provided
Crystal Display technology. matter at the atomic and molecular level in order to obtain
Thickness : 0.1 mm ¨
Shape memory alloy demonstration
materials and systems with significantly improved properties.
In this kit we are explaining about atomic arrangement in any ¨
Scanning Probe Microscope concept demonstration
Type : Nitrocellulose Polymer
material. With the help of this kit we can also learn how atomic
arrangement changes the properties of material. ¨
Extensive e-Manual
Aperture :29 mm
¨
Wide Aperture Optics Observer
¨
Two Year Warranty

Analyzer
¨
Accurate and Precise Arrangement Technical Specifications
Shape Memory wire : Ni-Ti alloy
Sample Dimension : Scope of Learning
¨
Freely Rotational Pointer Length : 77 mm
¡
Understanding scaling of Nanotechnology.
Polarizer Diameter : 0.7 mm
Analyzed light
Magnifying Lens ¡
Demonstration of arrangement of atoms in material using
¨
Extensive e-Manual
Magnification : 10 X diffraction patterns.
Illuminator Modified Polarizer Light
Diameter of Lens : 40 mm ¡
Demonstration of Concept of scanning probe microscope using
¨
2 Year Warranty Laser source : magnetic strip.
Subject to Change

Subject to Change
Polarized light Wavelength : 630 nm
¡
Demonstration of the change in atomic arrangement in Shape
Output : Less than 3mW
Memory Alloy.
Incoherent light Hot Air Gun : 200 Watt
Diffraction Grating : With 8 different atomic arrangement
Working of Polarizers

46 47
NV4501 NV4502
Nano TiO2 Solar Cell Kit Ferro Fluid Demonstrator
Nanotechnology

Magnified View shows


normal field instability

Ferro Fluid under the influence of strong magnetic field

NV4501 Nano TiO2 solar cell kit is a Nanotechnology based kit. ¨


A complete solution to prepare a Nano TiO2 Solar Cell NV4502 Ferro Fluid Demonstrator shows how magnetic
This Kit explains how Nanotechnology helps in the field of properties can exist in fluid state. Normally, a liquid is not
¨
Provided with Transparent Conducting Glass Plates
energy solutions. It illustrates energy conversion principles that expected to exhibit any magnetic properties. However, when
¨
Provided with Digital Multimeter
can be integrated with mainstream topics in physics, chemistry nanoparticles of a magnetic material are dispersed in a liquid,

and biology courses. It deals with thermodynamics of energy ¨


Provided with Light Source magnetic properties can be exhibited. The nanoparticles so
dispersed are not visible to our eyes. The magnetic fluid is
conversion and technology's impact on society. The Hands on ¨
Accessories are provided in a Carrying Case
known as Ferro fluid. This is a colloidal suspensions of magnetic
approach of the kit enables students to make their own solar cell
nanoparticles. Ferro fluids have the captivating property of
and to study the performance.
exhibiting “spikes” when placed in the proximity of a strong
magnet. The aim of the experiment is to demonstrate the novel
properties in the material using nanoscience.
Technical Specifications
Conductive glass plate:Tin Oxide coated
Dimension:2.5 ´
2.5 cm. (square) Scope of Learning
Resistance: 20 - 30 W
¡
Preparation of Nano TiO2 solar cell ¨
A comparison between the Bulk and Nano size Iron Scope of Learning
Electrolyte Solution:Iodine Electrolyte contain
Particles
Ethylene Glycol ¡
Study of solar cell in presence of sunlight
Dilute Acetic Acid Solution:100 ml, pH 2-3 in distilled water ¡
To study the comparison between the bulk and nano size iron
¡
Study of solar cell by using halogen lamp particles in liquid
Labolene (Surfactant):20ml ¨
Provided with Strong Magnet
Nano TiO2 Powder:10 gm
Hot Air Gun:200Watt ¡
To study the occurrence of spikes in Ferro fluid
Light Source:Halogen lamp
¨
Provided with Iron filing for Comparision
Subject to Change

Subject to Change
Input:220-240V, 50/60Hz
¡
To Study drug delivery system using Ferro Fluid.
Output Power:50Watt ¨
Accessories are provided in a Carrying Case

48 49
NV4515
Artificial Muscle Trainer
Technology Teaching Software

Nanotechnology
Artificial Muscle Trainer, NV4515 is designed to provide
exposure of working with Ionic Polymeric Metal Composites
(IPMC) artificial muscles. IPMC is abbreviation of Ionic Polymer Contents
It is an Innovative Technology Learning Software to provide
Metal Composite or Compound. It is a synthetic replacement for
Nanotechnology

THEORETICAL, PRACTICAL and EXPERIMENTAL training


damaged human muscle tissue, or a powerful alternative for
required for understanding the fundamentals of
hydraulic machinery that runs on electricity.
Nanotechnology. It is a unique training program to deliver high-
Developed for use as artificial muscles, IPMC can result in a quality courseware to Students & Teachers both.
Objectives of Simtel
large shape deformation by applying a low voltage. Applying a ? Teaching Tool for In-Class Teaching Programs
mechanical force to the substance will result in a proportional ? Student Learning Tool for their Individual Self Study
voltage being applied onto the surface. Because of this it can be ? Corporate & Industrial Training Programs
used as a Sensor and an Actuator. IPMC is a type of electro
Definition of Nanotechnology
active polymer
History of Nanotechnology
Scaling of Nano
It can be manufactured and cut in any size and shape or in
Photolithography
particular in the form of micro Sensors and micro Actuators for Electrospinning
MEMS applications. It consists of Nano sized metal particles,
and a very flexible polymer that never wears out (or at least takes
a long time).

¨
IPMC samples

¨
Microcontroller based display

¨
Angular scale for displacement measurement Technology Teaching Software
¨
Precise Signal conditioning Physics
¨
Self-contained and easy to operate
Contents
¨
2 Year Warranty It is an Innovative Technology Learning Software to provide
THEORETICAL, PRACTICAL and EXPERIMENTAL training
¨
e-Manual required for understanding the fundamentals of Physics. It is a
unique training program to deliver high-quality courseware to
Students & Teachers both.

Scope of Learning Technical Specifications Objectives of Simtel


Teaching Tool for In-Class Teaching Programs
?
To study the working of IPMC sample as a Actuator
¡ IPMC Sample (L ×

H) : 30.5 ×
4.2 ×
0.2 (mm)
Student Learning Tool for their Individual Self Study
?
Angular scale : 90°
- 0°
- 90° Corporate & Industrial Training Programs
?
To plot the graph between Displacements versus Voltage
¡
for a given IPMC sample
DC Supply : -12 V to +12 V I Electrostatics
To plot the graph between Displacements versus Current
¡ II Current electricity
for a given IPMC sample III Magnetic Effects of Current and Magnetism
IV Electromagnetic Induction and Alternating Current
Square Wave Generator :
Subject to Change

Subject to Change
To plot the graph between Voltages versus Current for a
¡ V Electromagnetic Waves
given IPMC sample (A nonlinear hysteresis behavior) Amplitude : 0 to 22 Vpp VI Optics
VII Dual Nature of Matter and Radiations
To study the working of IPMC sample as a Sensor
¡ Frequency : 1 - 21 Hz VIII Atomic Nucleus
IX Solids and Semiconductor Devices
X Principles of Communication

50 51

You might also like