You are on page 1of 4

| ERROR CODES | TOPOLOGY

Specific Error Code Indication Solution


1 Sensor Short Circuit Check Peripheral (Sensor)
4 Sensor Power Supply: Overload Check Peripheral (Sensor) Home Help

6 Line Break Check Wiring Cable You are here: Home/Slot000/Topology

7 Upper Limit Overshot Check Programming Cube67+ BN-EI/P Art.No. 56525 IP-Address 192.168.100.6
8 Lower Limit Overshot Check Programming
Slot 000 56525 Cube67+ BN-EI/P Status Properties I/O Length Save/Load Auto Config Reset Auto Refresh Topology
Branch 0
Use Webserver to Check Slot 001 56601 DIO16 E 8xM12
16 Parameter Error Slot 002 56603 DI16 E 8xM12
Parameters
Slot Saved Configuration Current Configuration
Branch 1
19 Actuator Power Supply: Overload Check Actuators Slot 101 56611 DIO8 E 4xM12 Branch 000

Slot 102 56603 DI16 E 8xM12 001 56601 56601


002 56603
23 Actuator Warning 24VDC Shorted to Output Branch 2 003
004
Branch 3
24 Actuator Short Circuit Check Actuators 005
006

26 Diagnostics Acc. to DESINA Cable Break, European Standard 007


008

40 Actuator Power Supply: Undervoltage Check Power Supply 009


010

41 Actuator Power Supply: Not Available Check Power Supply and Cabling 011
012
013
External Actuator Power Supply:
42 Check Power Supply 014

Undervoltage 015
016

External Actuator Power Supply: Branch 001


43 Check Power Supply and Cabling 101 56611 56611
Not Available
50 Sensor Power Supply: Undervoltage Check Power Supply
52 Power Supply Not Available Check Power Supply and Cabling
Ethernet/IP Connection Not Available. The error
Check Communication Cable and
86 occurs when the scanner fails to respond to the
Ethernet Switch
bus node switch-on or no connection is set up.
After the configuration is saved, a connected
module configuration was changed. The error is Check topology in webserver to
87 cleared when the current configuration is saved make sure current configuration
on the configuration is deleted. matches the saved configuration. Click the “Topology” tab to go to the topology page.
A reset is required. Here you will see a display of the saved configuration
Link Missing. Ethernet Connection was Lost. (column 2) and the current configuration (column 3)
88 Check Cabling
(Ethernet Cable Removed) on each branch or port of the bus node. When the
PLC connection timeout. This error is set when a
saved configurations don’t match the current
Check Requested Packet Interval configurations, the mismatched modules will be
89 timeout occurs on a PLC connection. The error is
(RPI) setting. Default = 10ms highlighted in red.
cleared after every new connection set up.
The error is set when an I/O module fails in Check input and output modules
99
service, for example, lost module. for failure/system cable damage.
Expand error message display
255 Buffer Overflow / Diagnostic Buffer Overflow in web server “Property” tab or
acknowledge existing errors

Murrelektronik, Inc. | 1400 Northbrook Parkway, Suite 300 | Suwanee, GA 30024 | P: 770-497-9292 | F: 770-497-9391 | murrinc.com
| HOME MENU | DIAGNOSTICS

Home Menu Link When you click on the module highlighted in red in
the Navigation section the page for the specific
module will load in your browser. To check the
diagnostics for the module, click on "Status" and the
page shown above will load.
Home Help

You are here: home

Cube67+ BN-EI/P Art.No. 56525 IP-Address 192.168.100.6

Home Help
Slot 000 56525 Cube67+ BN-EI/P
Branch 0
Slot 001 56601 DIO16 E 8xM12
Slot 002 56603 DI16 E 8xM12 You are here: Home/Slot000/Status
Branch 1
Slot 101 56611 DIO8 E 4xM12 Cube67+ BN-EI/P Art.No. 56525 IP-Address 192.168.100.6
Slot 102 56603 DI16 E 8xM12

Branch 2
Slot 000 56525 Cube67+ BN-EI/P Status Properties I/O Length Save/Load Auto Config Reset Auto Refresh Topology
Branch 3 Branch 0
Slot 001 56601 DIO16 E 8xM12 Apply/Refresh
Slot 002 56603 DI16 E 8xM12

Branch 1
Name: Cube67+ BN-EI/P art-No 56625
Slot 101 56611 DIO8 E 4xM12
Slot 1 56601 Slot 101 56611
Slot 102 56603 DI16 E 8xM12 Version: 1.03

Branch 2 Status: Okay

Branch 3
Last 5 Module Diagnostics: (Overflow is Displayed With Value “255”)

Channel
IP Address Branch No. Slot No. Global Error Code Specific Error Code Diag Active/Inactive Count Acknowledge
No.
6 0 0 0 Error No EI/P Connection 1 1 No Ack
Configuration
6 0 0 0 Error 1 1 No Ack
Navigation Section Slot 102 56603
Changed
No Ack
Slot 2 56603
No Ack
No Ack

Explanation of the diagnostic chart:


IP Address: Last octet of the IP address.
Branch No.: Indicates Bus Node port, number 0-3.
Slot No.: Indicates the module position on one of the
After you boot the web server (http://192.168.100.6), bus node ports.
the home page is displayed. The home page shows an
Channel No.: Indicates pin 4 or pin 2 on M12 port of
overview of the modules currently connected both I/O module (Pin 4: 0-7, Pin 2: 10-17) for 16 point module and
graphically and in list form. To return to this overview (Pin 4: 0-3, Pin 2: 10 – 13) for an 8 point module.
For correct operation of the Web Server from any submenu, click on the “Home” link in the
we recommend Internet Explorer, Version 7. Global Error Code: Indicates general error.*
upper left hand corner of your browser window.
Google Chrome does not support the Specific Error Code: Indicates specific errors.*
enabling of outputs.
You can get diagnostic information for any module Diag. Active/Inactive: Indicates if error is active (1)/inactive (0).
highlighted in red by clicking on it's name in the list Count: Indicates how many times the error occurred.
The information on this sheet applies view, also referred to as the Navigation section, which Scan the R to visit our online
Acknowledgement: With or without acknowledgement is
to CUBE67+ Ethernet I/P BusNodes is located to the left of the displayed overview. catalog where you can download configurable. If no acknowledgement is selected, error is
(Art. No. 56525) only. For information on
other modules or systems, please visit
data sheets, installation manuals cleared when the error is fixed. With acknowledgement, the
and more for CUBE67+ BusNodes. error message remains until it is acknowledged through the
our website, murrinc.com.
PLC or web server.
*Please see details in Error code descriptions.

Murrelektronik, Inc. | 1400 Northbrook Parkway, Suite 300 | Suwanee, GA 30024 | P: 770-497-9292 | F: 770-497-9391 | murrinc.com
| MODULE STATUS (MS) | SENSOR VOLTAGE (US)
NETWORK STATUS (NS) LEDs ACTUATOR VOLTAGE (UA) LEDs

MS NS US UA

| Possible LED States | Possible LED States


Solid Green Solid Red Solid Green Solid Red

Flashing Green Flashing Red Flashing Green Flashing Red

Off Off
MS US
Module Status (MS) LED Sensor Voltage (US) LED

LED Indication Solution LED Indication Solution


BusNode is OK Normal State Sensor and Communication
Normal State
Power OK (>18V)
Check Actual I/O Configuration
BusNode Configuration Changed Compared to Saved Configuration Power OK. Lost communication with I/O Check I/O modules on the port to see
in BusNode with Webserver module on branch port (0,1,2,3) which module has US LED off
Check I/O Module Connections Low Voltage and Check power. Check I/O modules on the
Lost 1 or more I/O Module Connections
and Cycle Power Lost Communication with I/O port to see which module has US LED off
No power to BusNode (<12V) Check Power Low voltage Check Incoming BusNode Power
or Module Failed (Initialization may take a few seconds)
No Sensor or Communication Check Incoming BusNode
Power (<13V) Power and Cabling
NS

Network Status (NS) LED


UA
LED Indication Solution Actuator Voltage (UA) LED
Communicating with PLC Normal State
Communication Ready and Waiting LED Indication Solution
Normal State
(No data exchange) Actuator Voltage OK (>18V) Normal State
Increase Requested Packet Interval (RPI) Low actuator voltage Check Incoming BusNode Power
Time Out Link to PLC
Time
No actuator power (<13V) Check Incoming BusNode Power
Conflicting IP Address on the Network Check IP Address
No connection/IP address Check Communication Cable

Murrelektronik, Inc. | 1400 Northbrook Parkway, Suite 300 | Suwanee, GA 30024 | P: 770-497-9292 | F: 770-497-9391 | murrinc.com
| LINK/ACTIVE (L/A) LEDs | SENSOR POWER SUPPLY (US)
ACTUATOR POWER SUPPLY (UA)
LEDs

L/A L/A

US UA
Port1 Port2

| Possible LED States | Possible LED States


Solid Amber Solid Yellow Solid Green Solid Red

Flashing Green Off Flashing Green Flashing Red

Off

L/A L/A

Link/Active (L/A) LED US UA Sensor Power Supply (US) LED


Port1 Port2

LED Indication Solution LED Indication Solution


Port connected to switch or Power and Communication OK (>18V) Normal State
Normal State
another BusNode
Power OK (>18V), No Data Exchange Check System Cable
Port connected to another device,
Check all Communication Cables Sensor Power Under Voltage
but no data transfer Check Power and Circuits
or Short Circuit
Data Transfer Normal State
Check circuits and see if the circuit is
Overload (I>4A)
No Cable Connection Check Cables drawing too much power
Low Voltage and No Data Exchange Check Power and System Cables
No Sensor Power (<13V) and
Check Power and System Cables
No Data Exchange

Scan the R to visit our online catalog where you can download data US UA
Actuator Power Supply (UA) LED
sheets, installation manuals and more for CUBE67+ BusNodes.
LED Indication Solution
Power and Communication OK (>18V) Normal State
The information on this sheet applies to CUBE67+ BusNodes only. For information on other Actuator Power Under Voltage
Check Power and Circuits
modules or systems, please visit our website, murrelektronik.com. or Short Circuit
Check circuits and see if the circuit is
Overload (I>4A)
For correct operation of the Web Server we recommend Internet Explorer, Version 7. drawing too much power
Google Chrome does not support the enabling of outputs. No Actuator Power (<13V) Check Power

Murrelektronik, Inc. | 1400 Northbrook Parkway, Suite 300 | Suwanee, GA 30024 | P: 770-497-9292 | F: 770-497-9391 | murrinc.com