You are on page 1of 3

***********************************************************************************

****

II N N N N OOOO SSSSS EEEEE N N


TTTTTTT
II NNN N NNN N OO OO S E NNN N T
II N NN N N NN N OO OO SSSSS EEE N NN N T
II N NN N N NN N OO OO S E N NN N T
II N NN N NN OOOO SSSSS EEEEE N NN T
copyright (c) 2016, InnoSenT GmbH
all rights reserved

***********************************************************************************
****

RELEASE NOTES - iSYS-4001 firmware:

supported devices:

- iSYS-4001
- iSYS-4002
- iSYS-4003

***********************************************************************************
****

NOTE:

InnoSenT had a product optimization for the iSYS-4001 end of year 2016.

Use the 1Vx firmware versions only for devices which have already an 1Vx
firmware running.

***********************************************************************************
****

iSYS4001_v1.312.hex 2016-
10-31

change log:

- added delay after RS485 Tx-Enable Pintoggle to ensure stable communication for
all baud rates

***********************************************************************************
****

iSYS4001_v1.310.hex 2016-
02-03

change log:

- number of frequency channels increased from 4 to 8


***********************************************************************************
****

iSYS4001_v1.309.hex 2015-
12-09

change log:

- same startup for all devices (iSYS-4001, iSYS-4002, iSYS-4003). After power up
and
intitialization routine, measurement mode will be started.

***********************************************************************************
****

iSYS4001_v1.308.hex 2015-
09-07

change log:

- new single target filter parameter added: min/max range and velocity

***********************************************************************************
****

iSYS4001_v1.305.hex 2015-
08-21

change log:

- bugfix in protocol read threshold-bins parameter


- bugfix in protocol get targetlist with 32-bit values

***********************************************************************************
****

iSYS4001_v1.304.hex 2015-
06-01

change log:

- limits for power supply voltage measurement adapted to support 5V supply

note:

- digital output driver do not work correctly with 5V supply. Take power supply
as
specified in datasheet, if using the digital outputs.

***********************************************************************************
****
iSYS4001_v1.303.hex 2015-
05-11

change log:

- bugfix in protocol, read frequency channel number

***********************************************************************************
****

iSYS4001_v1.3.hex 2015-
01-13

change log:

- optimization EEPROM write access