37SOP-SEC-002

Rev. 1
Turbine EH Regulation Oil System

Turbine EH Regulation Oil System


37SOP-SEC-002
Rev. 0
Turbine EH Regulation Oil System

1.0 Scope of Applicability

Initial conditions, precautions and operation steps of system put into service and out
of service are listed by this procedure.

2.0 Basis of Compilation

2.1 EH oil system flow diagram, 1-37J51-002-CNPP-45-JD, Rev. 2


2.2 Control and safety oil system, 1-37J52-002-45-JD, Rev. 3
2.3 325 MW Nuclear Power Station Condensing Steam Turbine Instruction book,
HN325-5.34

3.0 Initial Conditions

3.1 The power of instrumentation and equipment has been supplied.


3.2 The closed cycle cooling water system is operating.

4.0 Precautions

4.1 If the EH oil temperature is less than 10oC, start-up of oil pump is prohibited.
4.2 If the EH oil temperature is less than 21oC, the turbine rolling is prohibited.
4.3 While one EH oil pump is operating, second pump should be at auto standby
conditions.
4.4 In case of high differential pressure alarm across filter, the maintenance
personnel should be called to replace the filter.
4.5 Avoid direct skin touching with EH oil.
4.6 Before the start of turbine unit, the increase in EH oil temperature should be
monitored.
4.7 EH oil system should be put into service for 30 minutes before the turbine is
restarted.

Page 1 of 7
37SOP-SEC-002
Rev. 0
Turbine EH Regulation Oil System

4.8 The high pressure accumulator nitrogen gas normal operating pressure is 89
bar(g), with zero hydraulic fluid pressure. The accumulator should be checked
weekly and recharged if the gas pressure decreases to 79 bar(g) level.
4.9 The low pressure accumulator nitrogen gas normal operating pressure is 2.1
bar(g). Theses accumulator should be recharged if the gas pressure decreases
to 1.65 bar(g) level.

5.0 Operation Steps

5.1 Putting System into service:


5.1.1 Preparation of system status
a. Confirm that all instrumentation has been put into service
according to Appendix 1, “EH Oil system Instrumentation List”
and operating normally.
b. Ask local operator to check status of equipment according to
“EH Oil system Equipment Check List”.
c. Two EH oil pumps have been energized.
d. Confirm that EH oil tank temperature is more than 21oC,
otherwise, perform the following operation until the oil
temperature is normal.
i. If oil temperature is below 10oC, oil tank electrical
heater should be put into service until oil temperature
reaches > 10oC.
ii. If oil temperature is between 10~20oC, adjust the set-
point of oil flooding valve to the minimum value
(35kg/cm2)
iii. Start up one of corresponding EH oil pump to warm up
oil circulation. Adjust the set point of oil flooding valve
to 70kg/m2, when oil temperature reaches 16 C. (The
other one may be started up to increase the heating
rate).

Page 2 of 7
37SOP-SEC-002
Rev. 0
Turbine EH Regulation Oil System

iv. When oil temperature reaches 21oC, restore the set-


point of oil flooding valve, cut off oil tank heater and
maintain one EH oil pump operation.

5.1.2 Start one EH oil pump (if it has not been start up), confirm that the
current is normal and EH oil pressure is between 12.4~14.8 MPa.
5.1.3 Inform local operator to check system operation condition.
5.1.4 Perform EH oil pump interlock test.
a. Turn on the interlock switch of standby EH oil pump “to stand-
by position” (i.e. INLK A / INLK B).
b. Open test solenoid valve J051-V627, confirm that when oil
pressure decreases to 11.3 MPa, stand by pump will be start
automatically. Verify its current and pressure are normal.
c. Repeat steps a & b for other EH oil pump. After it is normal,
maintain one in operation and the other to serve as interlocked
stand-by.

5.1.4 Take notice of that EH oil temperature is controlled between the


normal range of (44~54oC).

5.2 Taking system out of service:


5.2.1 Confirm that turbine has been tripped.
5.2.2 Put the interlock switch of EH oil pump at “interlock off” position.
5.2.3 Stop the operating EH oil pump.
5.2.4 Inform the local shift person to close cooling water inlet/outlet valve of
EH oil cooler.
5.2.5 Put the interlock switch of EH oil tank electrical heater at “interlock
off” position.

Page 3 of 7
37SOP-SEC-002
Rev. 0
Turbine EH Regulation Oil System

6.0 Appendix 1

EH Oil system Instrumentation List

Instrumentation No. Instrumentation Name Remarks

EH oil tank temperature

EH oil pressure

Turbine emergency shut-off oil pressure

Turbine automatic stopping oil pressure

Time: ___________ Date: _______________

Performed by: _______________________________

Page 4 of 7
37SOP-SEC-002
Rev. 0
Turbine EH Regulation Oil System

7.0 Check List

EH Oil System Equipment Checklist


Time: ___________ Date: _______________

Equipment code Equipment Name Position Remarks


EH oil tank oil level Normal 1/2 ~3/4
No. 1 EH oil pump outlet valve Open
No. 2 EH oil pump outlet valve Open
EH oil high pressure side manifold Open
main valve
Pressure transmitter inlet oil valve Open
EH oil high pressure side manifold Closed
oil outlet valve
EH oil low pressure interlock Open
switch inlet oil valve
EH oil low pressure interlock test Closed
manual valve
No. 1 EH oil pump outlet pressure Open
meter valve
No.2 EH oil pump outlet pressure Open
meter valve
No.1 EH oil pump outlet filter net Open
differential pressure switch
positive pressure valve
No.1 EH oil pump outlet filter net Open
differential pressure switch
negative pressure valve
No. 2 EH oil pump outlet filter net Open
differential pressure switch
positive pressure valve
Oil temperature of EH oil tank Normal
Filter inlet oil valve Closed
Diatomaceous earth filter by-pass Closed
valve
EH reflux oil pressure switch Open
meter valve
EH reflux oil sampling valve Closed

Page 5 of 7
37SOP-SEC-002
Rev. 0
Turbine EH Regulation Oil System

Equipment code Equipment Name Position Remarks


EH oil cooler inlet three-way No.1/No.2
control valve
EH oil tank discharge oil valve Closed
No.1 EH oil pump inlet valve Open
No. 2 EH oil pump inlet valve Open
High accumulator inlet valve Open
High accumulator oil outlet valve Closed
High accumulator nitrogen Normal
pressure check
EH oil cooler cooling water inlet Open
main valve
EH oil cooler cooling water outlet Regulation
main valve
No.1 EH oil cooler cooling water Open
inlet valve
No. 1 EH oil cooler cooling water Open
outlet valve
No.2 EH oil cooler cooling water Open
inlet valve
No.2 EH oil cooler cooling water Open
outlet valve
No.2 auxiliary high accumulator Open
inlet oil valve
No.2 auxiliary high accumulator Closed
oil outlet valve
No.4 auxiliary high accumulator Open
inlet oil valve
No.4 auxiliary high accumulator Closed
oil outlet valve
No.2 & 4 auxiliary high Normal
accumulator nitrogen pressure
check
OPC pressure switch inlet oil Open
valve
Emergency shut-off manifold Open
diaphragm valve
No.1 auxiliary high accumulator Open
inlet valve

Page 6 of 7
37SOP-SEC-002
Rev. 0
Turbine EH Regulation Oil System

Equipment code Equipment Name Position Remarks


No.1 auxiliary high accumulator Closed
oil outlet valve
No.3 auxiliary high accumulator Open
inlet valve
No.3 auxiliary high accumulator Closed
oil outlet valve
No.1 & 3 auxiliary high Normal
accumulator nitrogen pressure
check
No.1 reflux oil accumulator oil Open
outlet valve
No.1 reflux oil accumulator oil Closed
outlet valve
No.3 reflux oil accumulator inlet Open
valve
No.1 reflux oil accumulator oil Closed
outlet valve
No.4 reflux oil accumulator inlet Open
valve
No.4 reflux oil accumulator oil Closed
outlet valve
No.2 reflux oil accumulator inlet Open
valve
No.2 reflux oil accumulator oil Closed
outlet valve

Time: __________________ Date: ________________

Performed by: ___________________ SS: _____________________ M(O): ____________