You are on page 1of 3

Page 1 of 3

PAWAN HANS LIMITED DOC. REF. NO.


JUHU AERODROME, MUMBAI : 400 056 EQ 08 DES 41

PROCEDURE SHEET FOR CAPACITY TEST OF NI-


CAD BATTERY PART NO. 20HKBN-25-J3 OF MI-172
REV. 2
AUG 2015
HELICOPTER FITTED WITH TV3-117VM ENGINES

APPROVED VIDE CAM LETTER NO. PHHL/WR/ENGG/DQC/5069, DATED 17/08/2015

Removed From Work Order No.

Component Sl.No. C.V. No.

TSBC/TSI. C.V. Date

T.S.N. Reason for Removal

REFERANCE: MAINTENANCE REQUIREMENT CARDS OF 20 HKBH-25-J3 MAINTENANCE SCHEDULE


LIST OF TESTERS
S/N DESCRIPTION SL. NO. CAL. VALIDITY
1 RF 80K/80H REFLEX CHARGER OR ANALYZER
2 Insulation tester 500 VDC
3 Digital Multimeter
4 Thermometer
5 Totque wrench
LIST OF TOOLS & EQUIPMENTS

Screw Driver, Spanners, Socket Wrench, Electrolyte filling device, Valve Key, Calibrated Nozzle,
Stiff Bristle Brush(non metallic), Safety Gloves, Goggles & Protective Apron

CONSUMABLES
Lint free cloths, Boric Acid Solution, Distilled Water, Detergent Powder

SL. NO. PROCEDURE TECH AME


1. Connect the battery to the tester. Charge the battery as per procedure
sheet EQ 08 DES 41-1.
2.
Set the discharge current to 10 Amps. And note the
time. TIME

3.
During discharge, when voltage reaches the value of 21 volts, measure
the voltage of each cell beginning with the positive
terminal of battery. TIME
Page 2 of 3

PAWAN HANS LIMITED DOC. REF. NO.


JUHU AERODROME, MUMBAI : 400 056 EQ 08 DES 41

PROCEDURE SHEET FOR CAPACITY TEST OF NI-


CAD BATTERY PART NO. 20HKBN-25-J3 OF MI-172 REV. 2
HELICOPTER FITTED WITH TV3-117VM ENGINES AUG 2015

SL. NO. PROCEDURE TECH AME


4. During discharge, note the time and discontinue discharge when any one
cell voltage falls below 1 volt of the battery voltage reaches 20 volts.

Cell voltage at the end of discharge.


Cell No. 1 2 3 4 5 6 7 8 9 10
Voltage

Cell No. 11 12 13 14 15 16 17 18 19 20
Voltage

5. Calculate the capacity in A.h according to the formula.


Q = J. t
Where, Q = Capacity (A.h)
J = Discharge Current (A)
t = Time of discharging (t)

ACTUAL CAPACITY OBTAINED A.h

NOTE : The capacity must not be less than 25 A.h during the first year of
operation and 21 A.h during the subsequent period of battery service.
6. Recharge the battery as per Maintenance Requirement Card 5 or
procedure sheet EQ 08 DES 41-1 for charging.
7. - Allow the battery to rest for few hours After finishing all the operation,
close the valves of the battery tight.
- Close the cover properly.
- Mark the C.T. date on the side of the battery.
- Complete the documentation.
Page 3 of 3

PAWAN HANS LIMITED DOC. REF. NO.


JUHU AERODROME, MUMBAI : 400 056 EQ 08 DES 41

PROCEDURE SHEET FOR CAPACITY TESTOF NI- CAD


BATTERY PART NO. 20HKBN-25-J3 OF MI-172 REV. 2
HELICOPTER FITTED WITH TV3-117VM ENGINES AUG 2015

SL. NO. PROCEDURE TECH AME


8 LIST OF PARTS REPLACED

SL.NO. PART NO. NOMENCLATURE QTY. REMARKS

I/we certify that aircraft/aircraft components/item of equipments enumerated above have been
removed/installed/inspected/modified/repaired/replaced/tested for operation as detailed above
and meets the requirements of Aircraft rules, Civil Airworthiness requirements and PHHL, MOE.

TECH ___________________________ SIGNATURE __________________________

DATE ____________________________ NAME _________________________

AME/APP.NO_________________________

DATE _________________________

You might also like