You are on page 1of 15

PENETRANT TEST REPORT

PENETRANT TEST REPORT


Customer : PT Degremont Drawing No : T 6486.06A Report No : U3-IR-ME-U1-048B
Client : PT IKPT Procedure No : QP-WLD-05 NCR Ref No :
Wo NO : 14122 Aplicable CODE : ASME Sect. V Acceptan Crit : API 650
Material Spec. : A 36 Welding Proces : SMAW
Penetrant Type/Method : visible solvent removable other
Brand's Name/type : Magnaflux Penetrant : Magnaflux SKL-SP 2
Methode pre-cleaning : solvent spray Drying after pre cleaning : 3 minutes
Penetrant Aplication : Brush Spray Dwei time : 5 min Temp : 29˚C
Light Intensity : Light Source :
Method Removing excess penetrant Remove with cleaner
Drying after remove excess penetrant Developer App : Spray Developer Time : 10 min
Batch No of penetrant : 150605 Cleaner : 150606 Developer : 408396
Surface preparation As welded Machining Grinding Solvent
Time of examination After welding After hydro After PWHT
Scope of examination Base Metal Edge prep Back chipping
Weld Part Repair Weld Other
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
BOTTOM PLATE
WL P 2/3 W 09 / W 014 10 ACC ND

BOTTOM PLATE
TO ANNULAR W 08 / W 09 /
J1 W 014 10 ACC ND

SHELL TO
ANNULAR W 08 / W 09 /
WL P 1/3 W 014 10 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
CWL 4/5 W 010 / W 011 8 TO 6 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
WLP 5/1 W 018/ W 011 6 ACC ND
WLP 5/2 W 018/ W 011 6 ACC ND
WLP 5/3 W 018/ W 011 6 ACC ND
CLP 5/6 W 09/W 08/W 01 8 ACC ND
CLP 5/7 W 09/W 08/W 01 8 ACC ND
CLP 6/7 W 09/W 08/W 01 8 TO 6 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
N2
WJ-02 W 016 7.11 TO 6 ACC ND
WJ-03 W 016 6 ACC ND

N3
WJ-06 W 014 7.11 TO 6 ACC ND
WJ-07 W 014 6 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
N1
WJ-12 W 014 7.11 TO 6 ACC ND
WJ-13 W 014 6 ACC ND

N4
WJ-16 W 016 7.11 TO 6 ACC ND
WJ-17 W 016 6 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
Annulare Plate
WLP P1/2 W 14 / W 09 10 ACC ND
WLP P3/4 W 14 / W 08 10 ACC ND
WLP P5/6 W 09 / W 08 10 ACC ND
WLP P7/8 W 14 / W 09 10 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
Nozzle Box
WJ-04 W 016 6 ACC ND
WJ-08 W 014 6 ACC ND
WJ-09 W 016 6 ACC ND
WJ-10 W 014 6 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
PENETRANT TEST REPORT
PENETRANT TEST REPORT
Customer : PT Degremont Drawing No : T 6486.06A Report No : U3-IR-ME-U1-048B
Client : PT IKPT Procedure No : QP-WLD-05 NCR Ref No :
Wo NO : 14122 Aplicable CODE : ASME Sect. V Acceptan Crit : API 650
Material Spec. : A 36 Welding Proces : SMAW
Penetrant Type/Method : visible solvent removable other
Brand's Name/type : Magnaflux Penetrant : Magnaflux SKL-SP 2
Methode pre-cleaning : solvent spray Drying after pre cleaning : 3 minutes
Penetrant Aplication : Brush Spray Dwei time : 5 min Temp : 29˚C
Light Intensity : Light Source :
Method Removing excess penetrant Remove with cleaner
Drying after remove excess penetrant Developer App : Spray Developer Time : 10 min
Batch No of penetrant : 150605 Cleaner : 150606 Developer : 408396
Surface preparation As welded Machining Grinding Solvent
Time of examination After welding After hydro After PWHT
Scope of examination Base Metal Edge prep Back chipping
Weld Part Repair Weld Other
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
SHELL
WLP 3/1 W 014 8 ACC ND
WLP 3/2 W 014 / W 011 8 ACC ND
WLP 3/3 W 09 8 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
PENETRANT TEST REPORT
PENETRANT TEST REPORT
Customer : PT Degremont Drawing No : T 6486.06A Report No : U3-IR-ME-U1-048B
Client : PT IKPT Procedure No : QP-WLD-05 NCR Ref No :
Wo NO : 14122 Aplicable CODE : ASME Sect. V Acceptan Crit : API 650
Material Spec. : A 36 Welding Proces : SMAW
Penetrant Type/Method : visible solvent removable other
Brand's Name/type : Magnaflux Penetrant : Magnaflux SKL-SP 2
Methode pre-cleaning : solvent spray Drying after pre cleaning : 3 minutes
Penetrant Aplication : Brush Spray Dwei time : 5 min Temp : 29˚C
Light Intensity : Light Source :
Method Removing excess penetrant Remove with cleaner
Drying after remove excess penetrant Developer App : Spray Developer Time : 10 min
Batch No of penetrant : 150605 Cleaner : 150606 Developer : 408396
Surface preparation As welded Machining Grinding Solvent
Time of examination After welding After hydro After PWHT
Scope of examination Base Metal Edge prep Back chipping
Weld Part Repair Weld Other
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
CWL 3/4 W 016 / W 011 8 ACC ND
WLP 4/1 W 010 / W 011 8 ACC ND
WLP 4/2 W 010 / W 011 8 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :
PENETRANT TEST REPORT
PENETRANT TEST REPORT
Customer : PT Degremont Drawing No : T 6486.06A Report No : U3-IR-ME-U1-048B
Client : PT IKPT Procedure No : QP-WLD-05 NCR Ref No :
Wo NO : 14122 Aplicable CODE : ASME Sect. V Acceptan Crit : API 650
Material Spec. : A 36 Welding Proces : SMAW
Penetrant Type/Method : visible solvent removable other
Brand's Name/type : Magnaflux Penetrant : Magnaflux SKL-SP 2
Methode pre-cleaning : solvent spray Drying after pre cleaning : 3 minutes
Penetrant Aplication : Brush Spray Dwei time : 5 min Temp : 29˚C
Light Intensity : Light Source :
Method Removing excess penetrant Remove with cleaner
Drying after remove excess penetrant Developer App : Spray Developer Time : 10 min
Batch No of penetrant : 150605 Cleaner : 150606 Developer : 408396
Surface preparation As welded Machining Grinding Solvent
Time of examination After welding After hydro After PWHT
Scope of examination Base Metal Edge prep Back chipping
Weld Part Repair Weld Other
Result Types of
Part Name Weld No Thickness Remark
Accepted Rejected Distinuitis
WLP 4/3 W 010 / W 011 8 ACC ND

Sketch (Ientifity discountinuity listed above ) if necessary

Examined by : PT Degremont PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


PT IKPT PT Synthetic Rubber Indonesia

Name : Abdurahman wahid


NDE Level : II
Date : Date : Date :

You might also like