Product name Phase U [V] Pump Q actual H actual [m] Energy [kWh/a] Price + energy

outlet [m³/h]
TPE 40-230/2-S 3 380-480 DN 40 9 15 1960 On request

Printed from Grundfos CAPS 1/13


Installation and Input Sizing Results
Flow (Q): 9 m³/h Head (H): 15 m Product number: 96275447
Type: TPE 40-230/2-S
Pumped liquid: HYCOOL 20 Quantity: 1
Supply: 380-480 V
Motor: 1.1 kW speed controlled
Flow: 9 m³/h ( max. +12 %)
Head: 15 m ( max. +25 %)
Power P1: 1.12 kW
Eta pump: 50.2 %
Eta pump+motor: 39.6 % =Eta pump * Eta motor
Eta total: 39.6 % =Eta relative to the duty point
Energy consumption: 1960 kWh/Year
CO2 emission: 1120 kg/Year
Price: On request EUR
Energy cost: 196 EUR /Year

Load profile
1 2 3 4
Flow 100 75 50 25 %
Head 100 100 100 100 %
P1 1.12 0.9 0.708 0.538 kW
Time 600 600 600 600 h/Year
Energy consumption 672 540 425 323 kWh/Year

Max. operation pressure: 10 bar


Min. inlet pressure: 1.5 bar

Pump Curve Dimensional Drawing


H TPE 40-230/2-S 167 167
(m) Q = 9 m³/h
100 % 167
24 H = 15 m 167 178
n = 88 % / 44 Hz
Viscosity = 3.2 mm²/s
20 Density = 1206 kg/m³
88 %

16
439
4 3 2 1
RP 1/4
141

12
68

8
40
102 102 320
4

Eta pump = 50.1 %


Eta pump+motor = 39.6 % M12
0
0 2 4 6 8 10 12 14 Q(m³/h)
132

P
132 132

(kW)
120

1.6
132

160
1.2

0.8

0.4

Printed from Grundfos CAPS 2/13


Position Qty. Description Single Price
1 TPE 40-230/2-S Price on request
Product No.: 96275447
Single-stage, centrifugal, in-line, single-head
pump.

The in-line design with opposite suction and


discharge ports enables mounting in pipework or
on a concrete foundation.

The shaft seal is a corrosion resistant


maintenance-free mechanical seal.

The pump is fitted with an IEC-flanged three-phase


MGE motor with frequency converter and
PI-controller integrated in the motor terminal
box. No additional motor protection is required as
both motor and electronics are protected by
integrated overload and temperature protection.

A differential pressure transmitter fitted on the


pump registers the differential pressure across
the pump and enables constant pressure or
proportional pressure control of the pump.

A control panel enables setting of required


setpoint as well as setting of pump to MIN or MAX
operation or to STOP. The control panel has
indicator lights for "Operation" and "Fault".

Communication with the pump is possible by means


of Grundfos R100 Remote Control enabling further
settings as well as reading out of a number of
parameters such as "Actual value", "Speed",
"Power input" and total "Power consumption".

The terminal box holds terminals for the


connection of :
- Pump start/stop (potential-free contact),
- external remote setpoint setting via analog
signal, 0 - 5 V, 0 - 10 V, 0(4) - 20 mA,
- 5 V voltage supply for setpoint potentiometer,
Imax = 5 mA,
- differential pressure sensor factory-fitted,
- input for forced control to MIN or MAX
(potential-free contact),
- potential-free fault signal relay with
changeover contact,
- RS485 GENIbus.

Liquid:
Liquid temperature range: -25 .. 90 °C
Density : 1206 kg/m³
Kinematic viscosity: 3.17 mm²/s

Technical:
Speed for pump data: 2835 rpm
Rated flow: 12 m³/h
Resulting flow of the pump: 9 m³/h
Rated head: 17 m
Resulting head of the pump: 15 m
Type of shaft seal: RUUE
Curve tolerance: ISO 9906 Annex A

Materials:
Material, pump housing: Cast iron
EN-JL1040 DIN W.-Nr.
25 B ASTM
Material, impeller: Stainless steel
1.4301 DIN W.-Nr.

Printed from Grundfos CAPS 3/13


Position Qty. Description Single Price
304 AISI

Installation:
Maximum ambient temperature: 40 °C
System pressure: 16 bar
Max pressure at stated temp: 16 / 90 bar / °C
Min inlet pressure: -0.8 bar
Standard, pipe connection: DIN
Size, pipe connection: DN 40
Pressure stage, pipe connec.: PN 6 / PN 10
Flange size for motor: FT100

Electrical data:
Motor type: MGE90SA
P2 : 1.1 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-480 V
Rated current: 2,60-2,30 A
Cos phi - power factor: 0,88-0,77
Rated speed: 360-3430 rpm
Enclosure class (IEC 34-5): IP55
Insulation class (IEC 85): F

Others:
Net weight: 45.8 kg
Gross weight: 49.2 kg
Shipping volume: 0.091 m³

Printed from Grundfos CAPS 4/13


Position Qty. Description Single Price
1 TPE 40-230/2-S Price on request

Note! Product picture may differ from actual product

Product No.: 96275447


Single-stage, centrifugal, in-line, single-head
pump.

The in-line design with opposite suction and


discharge ports enables mounting in pipework or
on a concrete foundation.

The shaft seal is a corrosion resistant


maintenance-free mechanical seal.

The pump is fitted with an IEC-flanged three-phase


MGE motor with frequency converter and
PI-controller integrated in the motor terminal
box. No additional motor protection is required as
both motor and electronics are protected by
integrated overload and temperature protection.

A differential pressure transmitter fitted on the


pump registers the differential pressure across
the pump and enables constant pressure or
proportional pressure control of the pump.

A control panel enables setting of required


setpoint as well as setting of pump to MIN or MAX
operation or to STOP. The control panel has
indicator lights for "Operation" and "Fault".

Communication with the pump is possible by means


of Grundfos R100 Remote Control enabling further
settings as well as reading out of a number of
parameters such as "Actual value", "Speed",
"Power input" and total "Power consumption".

The terminal box holds terminals for the


connection of :
- Pump start/stop (potential-free contact),
- external remote setpoint setting via analog
signal, 0 - 5 V, 0 - 10 V, 0(4) - 20 mA,
- 5 V voltage supply for setpoint potentiometer,
Imax = 5 mA,
- differential pressure sensor factory-fitted,
- input for forced control to MIN or MAX
(potential-free contact),
- potential-free fault signal relay with
changeover contact,
- RS485 GENIbus.

Liquid:
Liquid temperature range: -25 .. 90 °C
Density : 1206 kg/m³
Kinematic viscosity: 3.17 mm²/s

Printed from Grundfos CAPS 5/13


Position Qty. Description Single Price

Technical:
Speed for pump data: 2835 rpm
Rated flow: 12 m³/h
Resulting flow of the pump: 9 m³/h
Rated head: 17 m
Resulting head of the pump: 15 m
Type of shaft seal: RUUE
Curve tolerance: ISO 9906 Annex A

Materials:
Material, pump housing: Cast iron
EN-JL1040 DIN W.-Nr.
25 B ASTM
Material, impeller: Stainless steel
1.4301 DIN W.-Nr.
304 AISI

Installation:
Maximum ambient temperature: 40 °C
System pressure: 16 bar
Max pressure at stated temp: 16 / 90 bar / °C
Min inlet pressure: -0.8 bar
Standard, pipe connection: DIN
Size, pipe connection: DN 40
Pressure stage, pipe connec.: PN 6 / PN 10
Flange size for motor: FT100

Electrical data:
Motor type: MGE90SA
P2 : 1.1 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-480 V
Rated current: 2,60-2,30 A
Cos phi - power factor: 0,88-0,77
Rated speed: 360-3430 rpm
Enclosure class (IEC 34-5): IP55
Insulation class (IEC 85): F

Others:
Net weight: 45.8 kg
Gross weight: 49.2 kg
Shipping volume: 0.091 m³

Printed from Grundfos CAPS 6/13


Description Value H TPE 40-230/2-S
Product name: TPE 40-230/2-S A-F-A RUUE (m) Q = 9 m³/h
Product No: 96275447 100 %
24 H = 15 m
EAN number: 5700830062487 n = 88 % / 44 Hz
Viscosity = 3.2 mm²/s
Technical: Density = 1206 kg/m³
Speed for pump data: 2835 rpm 20
88 %
Rated flow: 12 m³/h
Resulting flow of the pump: 9 m³/h
Rated head: 17 m 16
Head max: 230 dm
Resulting head of the pump: 15 m 4 3 2 1
Type of shaft seal: RUUE
Curve tolerance: ISO 9906 Annex A 12
Pump No: 96463795
Pump version: A
8
Materials:
Material, pump housing: Cast iron
EN-JL1040 DIN W.-Nr.
25 B ASTM 4
Material, impeller: Stainless steel
1.4301 DIN W.-Nr. Eta pump = 50.1 %
304 AISI Eta pump+motor = 39.6 %
0
Material code: A 0 2 4 6 8 10 12 14 Q(m³/h)
P
Installation: (kW)
Maximum ambient temperature: 40 °C
System pressure: 16 bar 1.6
Max pressure at stated temp: 16 / 90 bar / °C
Min inlet pressure: -0.8 bar 1.2
Standard, pipe connection: DIN
Connect code: F
Size, pipe connection: DN 40 0.8
Pressure stage, pipe connec.: PN 6 / PN 10
Flange size for motor: FT100 0.4
P2 = 884 W
Liquid: 0 P1 = 1.12 kW
Liquid temperature range: -25 .. 90 °C
Density: 1206 kg/m³
Kinematic viscosity: 3.17 mm²/s

Electrical data:
Motor type: MGE90SA
P2: 1.1 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-480 V
Rated current: 2,60-2,30 A
Cos phi - power factor: 0,88-0,77
Rated speed: 360-3430 rpm
Enclosure class (IEC 34-5): IP55
Insulation class (IEC 85): F
Motor No: 85775805

Others:
Net weight: 45.8 kg
Gross weight: 49.2 kg
Shipping volume: 0.091 m³
Config. file no: 96280119

Printed from Grundfos CAPS 7/13


96275447 TPE 40-230/2-S
H TPE 40-230/2-S
(m) Q = 9 m³/h
H = 15 m
100 % n = 88 % / 44 Hz
24 Viscosity = 3.2 mm²/s
Density = 1206 kg/m³

20
88 %

16

4 3 2 1

12

Eta pump = 50.1 %


Eta pump+motor = 39.6 %
0
0 2 4 6 8 10 12 14 Q(m³/h)
P
(kW)

1.6

1.2

0.8

0.4

P2 = 884 W
0 P1 = 1.12 kW
Printed from Grundfos CAPS 8/13
96275447 TPE 40-230/2-S
cos phi TPE 40-230/2-S + MGE90SA 1.1 kW 3* 400 V, 50 Hz I
eta (A)

1 5

cos phi

0.8 eta 4

0.6 3
I

0.4 2

0.2 1

0 0
0 0.2 0.4 0.6 0.8 1 1.2 P2(kW)
n P1
(rpm) n (kW)

2500

2000 2

P1

1500

1000 1

500

n = 100 % 0

Printed from Grundfos CAPS 9/13


96275447 TPE 40-230/2-S

167 167
167
167 178

439
RP 1/4

141
68
40
102 102 320

M12
132

132

120
132
132

160

Note! All units are in [mm] unless others are stated.

Printed from Grundfos CAPS 10/13


96275447 TPE 40-230/2-S

96086116 SUPPLY:

L1 L2 L3
SEE NAMEPLATE
FOR FUTHER DATA
A:RS485A
Y:SHIELD
SIGNAL RELAY:

NC C NO
B:RS485B
MAX:250V/2A AC1
MIN: DC 5V/1MA

0-10V STOP
+OUT

+OUT

7: SENSOR INPUT
0/4-20M A 4-20M A 2: RUN/STOP
-

8: +24V RUN
3: GND
9: GND
4: SETPOINT
1: DIGITAL INPUT 0/4-20M A 0-10V
0/ 1 +
- 10K 5: +10V
CONNECTION FOR 6: GND
GRUNDFOS SENSOR

CONNECTION
OPTIONAL FOR PC-TOOL

Note! All units are in [mm] unless others are stated.

Printed from Grundfos CAPS 11/13


96275447 TPE 40-230/2-S
Input Sizing result
Select Type of Installation Type TPE 40-230/2-S
Installation Type Primary system only Quantity 1
One Chiller Supply 380-480 V
Your Requirements Motor 1.1 kW speed controlled
Flow (Q) 9 m³/h Flow 9 m³/h ( max. +12 %)
Head (H) 15 m Head 15 m ( max. +25 %)
Pumped liquid HYCOOL 20 Max. velocity 1.99 m/s
Min. liquid temperature -10 °C Min.inlet pressure -0.8 bar ( 50 °C, against
Liquid temperature during operation -10 °C atmosphere)
Max. liquid temperature 50 °C Power P1 1.12 kW
Max. operation pressure 10 bar Power P2 0.884 kW
Min. inlet pressure 1.5 bar Eta pump 50.2 %
Max. inlet pressure 1.5 bar Eta motor 78.9 %
Eta pump+motor 39.6 % =Eta pump * Eta motor
Control Mode
Eta total 39.6 % =Eta relative to the duty point
Constant Curve
Energy consumption 1960 kWh/Year
Type of Frequency Converter
CO2 emission 1120 kg/Year
Edit Load Profile Price On request EUR
Yearly operation time 100 days Energy cost 196 EUR /Year
Load profile Standard profile Price + energy costs On request EUR /15 Years
Consumption Q1 100 % Life cycle cost On request EUR /15 Years
Consumption Q2 75 %
Consumption Q3 50 % The shown results are only valid for Newtonian liquids!
Consumption Q4 25 %
Consumption Q1 9 m³/h H TPE 40-230/2-S
Consumption Q2 6.75 m³/h (m) 100 % Q = 9 m³/h
Consumption Q3 4.5 m³/h
Consumption Q4 2.25 m³/h H = 15 m
Time T1 600 h/a n = 88 % / 44 Hz
Time T2 600 h/a 20 88 % Viscosity = 3.2 mm²/s
Time T3 600 h/a Density = 1206 kg/m³
Time T4 600 h/a
Configuration 16
Single 4 3 2 1
Preferred number of poles
12
Pump design
Pump material
Inline Yes 8
End Suction, Close Coupled Yes
End Suction, Long Coupled Yes
With spacer coupling Yes 4
Operational Conditions Eta pump = 50.1 %
Frequency 50 Hz Eta pump+motor = 39.6 %
Phase 1 or 3 0
0 2 4 6 8 10 12 Q(m³/h)
Starting method 3 Phase
P
Min. power limit for SD start 5.5 kW
Voltage 1 x 230 or 3 x 400 V
(kW)
Ambient temperature 20 °C
Hit list settings 1.2
Allow uncontrolled No
Max. hits per product group 2
0.8
Max. hits total 8
Evaluation criterion Price + energy costs
Energy price 0.1 EUR/kWh
0.4
Calculation period 15 years 0
Load Profile
1 2 3 4
Flow 100 75 50 25 %
Head 100 100 100 100 %
P1 1.12 0.9 0.708 0.538 kW
Time 600 600 600 600 h/Year
Energy consumption 672 540 425 323 kWh/Year

Printed from Grundfos CAPS 12/13


Load profile
Q 9.0
[m³/h]

6.8

4.5

2.3

t
0 600 1200 1800 2400 [h]
1 2 3 4
Flow 100 75 50 25 %
Head 100 100 100 100 %
P1 1.12 0.9 0.708 0.538 kW
Time 600 600 600 600 h/Year
Energy consumption 672 540 425 323 kWh/Year

Total head 15 m

Dimensioning flow 9 m³/h

Printed from Grundfos CAPS 13/13