1492BF

Low pressure regulator 180 kg/h LPG

Application Features
• These low pressure regulators are mainly used as second • High performance, well stabilised outlet pressure,
stage regulation device in high capacity LPG installations thanks to the balanced seat design.
like: • Compact and robust design.
- gas supply for industrial processes • Pre-set outlet pressure, internally adjustable
- canalised distribution for domestic gas supply. • Reinforced diaphragm sealed with an independent
• They can also be used with other non-aggressive gases : O-ring.
Natural Gas, Nitrogen, Air,…. • Integral pressure relief valve.
• They can be equipped with a safety against overpressure • Vent protected from rain by a labyrinth design
(OPSO) and against underpressure (UPSO).
• Easily dismountable for inspection and maintenance.
• Working temperature: -20 / +60°C (-4 / +140°F).
• Made in EC, joint project Coprim-Clesse

Construction
• Housing and cover in die-cast aluminium alloy protected
Compliance to directive by painting.
• Valve body in spheroidal graphite cast iron SF420,
All regulators are manufactured in compliance with the protected by zinc coating.
Pressure Equipment Directive (PED 97/23/CE. • Diaphragm in NBR complying with EN 549 reinforced
They are marked. with polyamide fibres.
• Valve pad and seals, in NBR complying with EN 549.
• Spring in zinc coated steel.
• External sensing device . Compression fitting ∅10mm
• Seat Ø 17mm
1492BF
Low pressure regulator 180 kg/h LPG
Performances
50 80
051002AH 051002AK
70
Pe = 4bar
40 Pe = 4bar
60 Pe = 1bar
Outlet pressure (mbar)

Outlet pressure (mbar)


Pe = 1bar
50 Pe = 0,6bar
30 Pe = 0,5bar
Pe = 0,3bar Pe = 0,3bar
Pe = 4bar Pe = 4bar
40
Pe = 1bar Pe = 1bar
20
30
Pe = 0,5bar Pe = 0,3bar Pe = 0,6bar
Pe = 0,3bar
20
10
10
Flow rate - Propane (kg/h) Flow rate - Propane (kg/h)
0 0
0 100 200 300 0 100 200 300

Product range
Inlet Outlet Inlet Outlet Guaranteed Opso-Upso
Product Product Outlet Pressure Cg Pressure
Connectio Connectio Pressure Pressure Wh flow-rate Weight Connection
Code Name Pas (Wa) (2-4) (6) relief valve
n n bpe (1) (3) Propane (5)
Rc 1'' Rc 1 1/2'' 0,5-4 bar 30(25-38) mbar 16-100 mbar 180 kg/h Pas +
051002AH 1492BF 230 3kg Yes
(BSP-ISO7) (BSP-ISO7) 7-58 psig 12(10-15) inch w.c. 6,5-40 inch w.c. 8,5 MBTU/hr 45±15mbar
Rc 1'' Rc 1 1/2'' 0,6-4 bar 50(40-60) mbar 16-100 mbar 180 kg/h Pas +
051002AK 1492BF 230 3kg Yes
(BSP-ISO7) (BSP-ISO7) 9-58 psig 12(10-15) inch w.c. 6,5-40 inch w.c. 8,5 MBTU/hr 45±15mbar
(1) Inlet pressure, bpe:
bpe= range of inlet pressure (Pe.min-Pe.max), for which the regulator guarantees, at nominal setting, the given precision class AC.
For an adjustment different that the nominal setting, one must consider: Pe.min=Pa adjusted + 0,5bar
(2) Outlet pressure Pas(Wa):
Pas= pre-set outlet pressure Wa = possible adjustment range (Pa.min-Pa.max) with the original spring
(3) Outlet pressure Wh : maximum possible range, changing the spring
(3) Precision class : AC=20
The maximum fluctuation, in%, of the outlet pressure, for any inlet pressure in the bpe range and for any flow between 10% and 100% of the guaranteed flow rate.
(5) Guaranteed flow rate, Q(kg/h):
This refers to commercial propane at 15°C and 1013mbar atm. pressure. For other gases : Qbut (kg/h)=1.14xQ(kg/h) , Qnat gas ([n]m3/h)=0.82xQ(kg/h)
For inlet pressures higher than the minimum specified value (Pe.min), the flow rate can be higher than the guaranteed flow rate..
(6) Calculation of the volumic flow rate possible in all conditions:
Qv = volumic flow rate - (n)m3/h -
- for (Pe-Pa)≤0,5(Pe+Pb) : Pb = atmospheric pressure - bar -
Pe et Pa = inlet and outlet pressures - bar -
d = relative density of the gas, in relation to air
- for (Pe-Pa)>0,5(Pe+Pb) : te = temperature of the gas on inlet - °C -
Cg = flow coefficient of the regulator

Installation
1- Upstream valve
7 2- Manometer with nail valve
3- Filter
4- Regulator
5- Downstream valve
6- Discharge valve
7- Sensing pipe

Advised installation OPSO-UPSO on regulator


Buffer volume
In case of installations submitted to sudden variations of flow (e.g. a burner with cyclic on/off operation), all of the downstream piping should be of sufficient volume
(V) in relation to the volumetric flow rate (Qv), in accordance with the following formula : V(litres)>Qv((n)m3/h).

Accessories
- OPSO-UPSO safety device
- manometers
FM-1391-1392-EN2-31026

- filters
- buffer volume
The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy, they are not to be construed as
warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs
or specifications of such products at any time without notice.

For more information, contact COMAP,


16, avenue Paul Santy, 69008 LYON – FRANCE Tel : + 33 4 78 78 16 00 - Fax : + 33 4 78 78 15 25 - email : gaz@comap.fr

You might also like