GENERAL

This drawing is not be to scaled, use figured dimensions only


All dimensions and heigts to be checked before any work
commences on site Any discrepences to be reported to the Architect immediately
All heights of plinths, depths of excavations and number of steps
to be finally checked by the contractor on site.
This drawing must be read in conjunction with the Structural Engineer's drawings.
The site must be treated for termites in accordance with Municipal By-Laws using
SHELLDRITE soil poisoner.
Top of foundations to be a minimum of 600mm below natural ground level.
Backfill to foundations.
Top of concrete floor slab to a minimum of 200mm above finished ground level.
Concrete floor slab to be reinforced with S310 mesh wire. Black polythene
damp proofing membrane on 50mm sand binding on well compacted hardcore.
GUNDLE brickgrip emborsed damp proofing course under all brick walls,
windowsills and where floor levels change. Stormwater shall be removed
plaster & paint plaster & paint from dwelling, yard and site.
Electrical installations shall be a HEINEMANN earth leakage systems in
distribution board.
All building works to be carried out in accordance with municipal By-Laws
with the inspector approving every stage.
FOUNDATIONS
Drainage to engineer's specifications.
All foundations, foundation walls, structural concrete works and subsoil stormwater
footings under 230mm brickwalls.
WEST ELEVATION EAST ELEVATION 230 x 460 concrete strip footings under 115mm brickwalls and 230x690 concrete strip
FLOORS
SCALE :1-100 SCALE :1-100 75 x 19mm timber skirting with 9mm quadrant all round.
40mm rough cement screed to all floors (tiles in kitchens and baths) rest with blocks.
WALLS
All bricks to have GUNDLE dump proofing course on slabs and brickforce after every
eleven brick courses.
All bricks approved burnt clay commons/facings from Willdale or any other reputable
manufacturer (CAZ) approved.
Windows to be built-in with GUNDLE damp proofing course under cill bricks.
8775 All paint works to comply with manufacturer's specifications and with
840 7935 necessary under coats.
External finish rough cast plaster with three coats pva.
230 230 115 115 230 Internal finish steel trowel plaster, rhinoset skimming and 3 coats pva.
610 1793 2252 3200
ROOF
rw Asbestos cement trafford roof 0n
100mm dia p.v.c pipe laid to fall 1:60 minimum Gangnailed/sawn timber roof trusses, valleys and trimmings around chimneys
gully gully chimneys to be manufactured and erected by timber specialist.
WINDOWS AND DOORS
230

230
All windows and door frames standard pressed steel sections by
ab ab ab ab 6mm glazing/anodised alluminium sliding doors by specialist.
wc

shower
ENSUITE wc

DRAINAGE
(16.97 sqms)
1750

270 BATH
tub

100mm glazed earthenware sewer drain with a minimum fall of 1:60


100mm dia p.v.c pipe laid to fall 1:60 minimum
2800

(3.52 sqms)
2700

Rodding eyes at all head of drain and at all change of direction


ab and at every 15m intervals.
(1.06 sqms)wb
wb

Inspection eyes at junctions to have clearly marked covers on ground level.


BEDROOM 3
230 705 115

NORTH ELEVATION
BIC

SOUTH ELEVATION
shower

Drains under buildings to be 100mm cast iron pipe encased in 150mm concrete
.......

(ceramic tiles) and waste pipes under floor slabs to sleeved.


(9.90 sqms) All waste pipes must 65mm reseal traps and to be accessible over the entire
ab SCALE :1-100 SCALE :1-100 length for cleaning and repairing purposes.
PASSAGE
(4.25 sqms)

485

485

ab BIC Gutter down pipes must discharge at a distance of not less than 1500mm
(granno)

ab BIC
115
1096

from an open gulley.


BEDROOM 1 1542 115 1543 ab
(ceramic tiles)
(12.43 sqms) 3200
ELECTRICAL LEGEND
3200

3200
3660

2700
BIC

1000 BEDROOM 2 Distribution board 1500 above floor level.


1989

3285 600 (ceramic tiles)


(9.39 sqms) Ceiling mounted light fitting.
ab ROOF PITCH 22
ab ab
gully

Wall mounted light fitting.


115
230

3160 ab CONCRETE TILES ON 38X38 BATTENS ON TRUSSES BY SPECIALISTS ON


ab fridge stove 114X38 WALL PLATE
E E Waterproof ceiling mounted light fitting.
200X50 FASCIABOARD
14575

14575
s.s.s

KITCHEN
2270

RHINOBOARD CEILING ON 38X38 BRANDERING AT 400 CENTERS Outside waterproof wall light.
2155

2155

2500

(ceramic tiles) rw
(9.82 sqms) 75X100 G.I GUTTERS ON GUTTER DOWNPIPES AND DRIPSTONE UNDER
Surface ceiling mounted downlighter.
ab ab Telephone Connection.
DINING
230

230

ab (ceramic tiles) ab
rated door
1hr fire

(7.80 sqms) TV Connection.


WALL TO BE UNDER SIDE OF ROOF COVERING

ab
50 Liter 1Kw Geyser connection.
LOUNGE
(ceramic tiles) TIMBER TRUSS BY SPECIALIST
3500

3500
3960

100 Liter 2Kw Geyser Connection.


ab (17.81 sqms)
plasterboard ceiling plasterboard ceiling 150 Liter 3Kw Geyser Connection.
r.c lintel
5500

ab 5000
15 Amp Plugpoint.

2750
ab ab LOUNGE Double 15 Amp Plugpoint.
230 615 230 925 230

KITCHEN
ab (ceramic tiles)
VERANDAH Light dimmer switch.
1155

(5.20 sqms) dpc dpc


GARAGE 293 Light switch 1240 above floor level.
(power floatfinish)

230470
ARCH OVER TO ENGINEER
845

ab (16.97 sqms) ab 40mm CEMENT AND SCREED ON Two-way light switch.


230

100mm CONCRETE SLAB ON


690x230 FOOTING 150mm WELL COMPACTED HARDCORE FILL 690x230 FOOTING Bell switch
4770 2499 690X230mm CONCRETE FOOTING UNDER 230mm WALLS
500X230mm CONCRETE FOOTING UNDER 115mm WALLS Bell
230 230 230 293 293 230
460 4770 3545
Track with adjustable spot lights.
8775
SECTION E-E 1:100 Wall Spotlight.

Oven connection.
FLOOR PLAN (120) 1:100 Underfloor heating with thermostat.
Single fluorescent light fitting.

Double fluorescent light fitting.


Intercom unit.

SCALES
TITLE 1:100 1:200 DESIGNED

PROPOSED HOUSE ON ROYALE PROPERTIES REVISIONS

FOR .................................
Date Descriptions Initials ADDRESS

DATE