You are on page 1of 12

SENG SEGAT PHASE-3 DEVELOPMENT

PROJECT

DATA SHEET

A 08/06/2018 Issued for Review & Comment MC IP SER


REV. DATE DESCRIPTION PREPARED CHECKED APPROVED CLIENT APPROVED

Project Title:
CUSTODY TRANSFER METERING SYSTEM
SENG SEGAT PHASE-3 DEVELOPMENT PROJECT

Client :

EMP BENTU LTD.

Contractor :

PT. HANDIYAN HULU INSTRUMEN

HHI Doc. No. HHI-EMP-DS-000 Revision: A

PO. No. : Status Doc. :


TABLE OF CONTENT

1 COVER PAGE

2 TABLE OF CONTENT

3 Data Sheet for Ultra Sonic Meter

4 Data Sheet for Flow Computer

5 Data Sheet for Double Block and Bleed Valve 8"

6 Data Sheet for Gas Chromatograph

7 Data Sheet for Moisture Analyzer

8 Data Sheet for H2S Analyzer

9 Data Sheet for Pressure Transmitter

10 Data Sheet for Temperature Transmitter


11 Data Sheet for Pressure Indicator
12 Data Sheet for Temperature Indicator
DATA SHEET
ULTRASONIC FLOWMETER
PROJECT: CUSTODY TRANSFER METERING SYSTEM SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-001-USM
1 Tag Number FT 601A; FT 602A 42 Manufacture: Elster-Instromet
QSonicPlus

PURCHASE
Service Custody Transfer Gas
GENERAL

2 43 Model :
3 P&ID No. HHI-EMP-P&ID-001 44 Serial No. : VTA
4 No of Units Required 2
5 Piping Specification ANSI/ASME B31.3 600# Class
SITE DATA

6 Hazardous Area Classification Class 1, Div 2, Group D, T4


7 Ambient Temperature (deg C) Min: 25 Norm: 30 Max: 35
8 Humidity (% R.H) Min: 58 Norm: 88 Max: 99
9 Fluid Natural Gas
10 Operating Pressure (Psig) Min: 800 Norm: 1000 Max: 1060
PROCESS DATA

11 Operating Temperature (deg.F) Min: 90 Max: 105


12 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70
13 Design Pressure (Psig) Min: 0 Max: 1300
15 Design Temperature (deg.F) Min: -20 Max: 200
16 Density (lb/ft3) Min: Max:
17 Absolute Viscosity (cP) Min: Max:
18 Molecular Weight Min: Max:
19 Specific Heat Ratio Cp/Cv Min: Max:
20 Body A333 Gr. 6 (Seamless)
21 Size 8", 600 RF
22 Capacity Range @Operating Press. & Temp. 0 to 328 MMSCFD
METER

23 Velocity Range 0 to 98 ft/sec


24 Uncertainty 0.2% (after wet calibration) from Qt to Qmax
25 Repeatability ≤ ±0.05% of reading
26 Design Code ASME B31.3
27 Nominal Dia Schedule 8" SCH 80 (Note 4, 5)
28 Number of Paths 6 path
29 Number of transducer 12
TRANSDUCER

30 Model NG
31 Operating frequency 200 kHz
32 Material Full metal: Titanium (Ti Gr 2)
33 Mechanical design pressure 255 barg
34 Mechanical design temperature -40 to 90oC
35 Electrical connection M20 cable entries (5 off)
SIGNAL PROCESSING UNIT

36 Material housing Alluminium cast alloy (epoxy coated)


37 Ingreess protection IP66 / NEMA 4X
38 Output 2 serial ports (RS-232/RS485configurable) ;1 ethernet port / high speed VDSL
2 frequency outputs (0 to 5 kHz) ; 2 digital outputs 2 ; 2 analogue outputs 2
1 USB port (for localparameterization/ diagnostics)
39 Serial interface RS-485; Standard Elster-Instromet protocol or Modbus
40 Power supply Nominal 24 VDC (18 to 36 VDC), <20 W
41 Local display GUI, 4.3" widescreen graphical colour display with touchscreen (Haz. Area of Class 1 Div. 2)

Notes :
(1) From Qt to Qmax, relative calibration laboratory and undistrurbed inlet / outlet section of 10D / 3 D respectively
(2) Analogue outputs and digital outputs sharing the terminal connections
(3) The metering shall cover for flow turn down of 1 : 70
(4) All welding with the nominal thickness more than 20 mm shall be PWHT as per ASME B31.3
(5) The meter bore shall have the roughness of 250 micro inch (Ra) or less including upstream/downstream metering piping spool
DATA SHEET
FLOW COMPUTER
PROJECT: SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-002-FC
1 Tag Number 39 Manufacture : FloBoss

PURCHASE
GENERAL

2 Service Custody Transfer Gas 40 Model : S600+


3 P&ID No. HHI-EMP-P&ID-001 41 Serial No. : VTA
4 No of Units Required 2
5 Hazardous Area Classification Zone 1, Gas Group IIA, IIB & II C
ENVIRONTMENT
CONDITION

6 Operating Temperature (deg C) Min: -10 Max: 60


7 Storage Temperature (deg C) Min: -40 Max: 70
8 Relative Humidity Min: 58 Norm: 88 Max: 98
9 Maximum Altitude 2000 meter
10 Microprocessor Cold fire MPC 8313C 333MHz
11 Memory DRAM - 128 MB; SRAM - 4 MB; Flash ROM - 256 MB
12 Batery Back up Batery lithium 3 Vdc 1500 mA ; Back up 30 to 20 ⁰C
Batery life 5 to 7 years
13 Power Supply 24 VDC
HARDWARE SPECIFICATION

14 Keypad Numeric keypad with 4 funtion keys and navigation button


15 Alarm Alarm LED provided at the panel front
16 Mounting Panel Flush mounted.mounting brakets to be provided
17 Power Consumption 24 Watt
18 Board :
*. CPU With Additional Ethernet 1 no. x P152 CPU board with dual ethernet ( 10/100 Mbits/S FD )
*. I/O With Mezzanine 1 no. x P144 I/O Board, 1 no. x P148 Mezzanine
*. Keypad 1 no. display - keypad ( with connectivity watchdog )
*. Prover NA
19 Standart Condition 15 Deg C, 1.01325 bara
20 Clock 33 MHz (min)
21 Protocol / Ethernet Port Modbus ; TCP/IP for Ethernet / 2 no. Dual Ethernet Communication
22 Serial Port - RS 232 2 no. ( 1x alarm printing; 1x peer to peer communication )
23 Serial Port - RS 485 4 no ( 2 x USM SOS; 2 x multidrop Comm with GC )
24 Protocol Modbus for serial comms; TCP/IP for ethernet
DATA TRANSMISION

25 Analog Input 12 no. for PT,TT


26 Analog Output 4 no. for flowrate signal to local control panel
27 Pulse Input 2 no. for ultrasonic meter signal
28 Digital Input 5 no. for Hand valve status ( Open,Close,etc…)
29 Digital Output 12 no. for duty FC command
30 Frequency Input
31 Pulse Output Not Used
32 Raw Pulse Output Not Used
33 RTD input Not Used
34 Calculation AGA 7, AGA 8, AGA 10, GPA 2172 & 2145, ISO 6976
35 Software Config 600 Lite+
OTHER

36 Mounting Provided
37 Configuration cable Provided
38 Interface Dedicated communication port at panel front for the config pro interface
DATA SHEET
GAS CROMATOGRAPH
PROJECT: SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review MC IP SER
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-004-GC
1 Tag Number 50 Manufacture ABB/Galvanic

PURCHASE
Service Custody Transfer Gas Model NGC 8206
GENERAL

2 51
3 P&ID No. HHI-EMP-P&ID-001 52 Serial No. VTA
4 No of Units Required 2
5 Piping Specification ANSI/ASME B31.3 600# Class
SITE DATA

6 Hazardous Area Classification Class 1, Div 2, Group D, T4


7 Ambient Temperature (deg C) Min: 25 Norm: 30 Max: 35
8 Humidity (% R.H) Min: 58 Norm: 88 Max: 99
9 Fluid Natural Gas
PROCESS DATA

10 Operating Pressure (Psig) Min: 800 Norm: 1000 Max: 1060


11 Operating Temperature (deg.F) Min: 90 Max: 105
12 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70
13 Design Pressure (Psig) Min: 0 Max: 1300
14 Design Temperature (deg.F) Min: -20 Max: 200
15 Dimensions 6.75" diameter x 16" long x 9" tall
16 Weight Approx. 12.7 kg
GENERAL DESIGN

17 Housing Material ATEX Type 4x (IP 66 Eq.), CSA Type 4x, IECEx IP56
18 Power Requirement 220 VAC
19 Power Consumption Normal: 7 W for non heated version; Less than 120 W for heated version
20 Range Operation 800 to 1500 BTU/SCFD less than 100 ppm H2S
21 Installation Inside 3 side Shelter, close to sample point
22 Mounting Stand Alone Pipe Mount
23 Hardware 2 Paralel Isothermic GC Modules with narrow-bore capillary column technology in combination with
ANALYTICAL SECTION

MEMS based analytical components


24 Detector Type TCD Detection
25 Analysis Output Full compilation of any natural gas up to C6+, Heating value, Density, Wobbe Index
26 Repeatability ± 0.125 % BTU @ 1000 BTU (± 0.025%)
27 Uncertainty Better than 0.1 % for all calculated properties
28 Analysis Time 5 min
29 Detected Components N2 - CO2, C1 to C6+
ELECTRONIC SECTION

30 Processor board 16 bit processor 133 MHz, 32 MB flash memory


31 Communication Ethernet UTP 10 Base T for Modbus TCP/IP and PC link
Two RS 232/485/422 ports (User selectable) for Modbus RTU
32 Memory Up to a total 2 GB of RAM, CPU RAM Memory 20 MB, Nand Flash 32 MB, Data Storage 128 MB to 2 GB
33 Electrical Connection M20
34 No. of Sampling Stream 2 Ea 40 Sample Probe Type Retractable
SAMPLE CONDITIONING

35 Functional Test Acc. Manufacture Standard 41 Sample Outlet Size 1/2" NPT
SYSTEM

36 Sample Outlet Vented to Atmosphere / 1/2" NPT 42 Heat Tracing No


37 Fast Loop Sampling Provided 43 Material - Fitting 316 SS
38 Material - Impulse Tube 316 SS 44 Calibration Gas Type C1 to C6+
39 Carrier Gas Type 99.995%
45 Technical ATEX, Class 1, Zone 1 Groups IIB
APPROVAL AND
CERTIFICATES

46 Analytical Nmi Test Certificate


47 Calculations GPA 2172-96 (Z by AGA 8 or ISO 6976-95; ISO 12213 (by AGA8)
48 Electronics EMC - EMI/RFI: EN 55022, EN 61000-6-1, EN 61000-4-2, 4-3, 4-4, 4-6, 4-8
49 Marking Manufactures Standard
DATA SHEET
MOISTURE ANALYZER
PROJECT: SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review MC IP SER
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-005-MA
1 Tag Number 46 Manufacture: Ametek

PURCHASE
Service Custody Transfer Gas
GENERAL

2 47 Model No. : 3050 OLV


3 P&ID No. HHI-EMP-P&ID-001 48 Serial No. : VTA
4 No of Units Required 2
5 Piping Specification ANSI/ASME B31.3 600# Class
SITE DATA

6 Hazardous Area Classification Class 1, Div 2, Group D, T4


7 Ambient Temperature (deg C) Min: 25 Norm: 30 Max: 35
8 Humidity (% R.H) Min: 58 Norm: 88 Max: 99
9 Fluid Natural Gas
PROCESS DATA

10 Operating Pressure (Psig) Min: 800 Norm: 1000 Max: 1060


11 Operating Temperature (deg.F) Min: 90 Max: 105
12 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70
13 Design Pressure (Psig) Min: 0 Max: 1300
14 Design Temperature (deg.F) Min: -20 Max: 200
15 Sensing Element Quartz Crystal Microbalance (QCM)
16 QCM Response Time Near Real Time
17 Measuring Range 0.1 - 2500 PPMV (Part per Million by Volume)
18 Limit of Detection 0.1 PPMV
19 Accuracy 10% of Reading
20 Sensitivity 1 % of Reading
21 Reproducibility ± 5% of reading from 0 to 2500 PPMV
22 Reference Gas Actual sample gas
23 Online Verification Yes, verification with internal moisture generator with NIST traceable
24 Auto Calibration Yes
ANALYZER

25 Typical Flow 150 sccm


26 Allowable Inlet Pressure 20 - 50 Psig
27 Sample Gas Temperature 0 to 100 deg.C
28 Exhause Pressure 0 to 15 Psig
29 Power Requirement 120 VAC, 50 / 60 Hz, 150 W
30 Size Analyzer Enclosure & Plate (W x H x D) 367 x 324 x 430 & 800x600 mm
31 Approval CSA
32 Analog Output 4 - 20 mA
33 Serial Data Output Erial, RS 485
34 Alarm Digital Output Signal (Fault Alarm, Concentration Alarm)
35 Display No
36 Sample Tubing Connection 1/4" OD
37 Cable Entry M20 Cable Gland
38 Sampling Conditional System Required, MFR Std.
SAMPLING SYSTEM

39 Filter Included
40 Contaminant Trap Included
41 Pressure Reducer Included
42 Heated Pressure Reducer Included
43 Utility Gas Nitrogen, 47 L
OTHER

44 Pressure Gauge Included


45 Pressure Regulator Included
DATA SHEET
H2S ANALYZER
PROJECT: SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review MC IP SER
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-006-H2S
1 Tag Number 36 Manufacture Ametek

PURCHASE
Service Custody Transfer Gas Model No. 933
GENERAL

2 37
3 P&ID No. HHI-EMP-P&ID-001 38 Serial No. VTA
4 No of Units Required 2
5 Piping Specification ANSI/ASME B31.3 600# Class
SITE DATA

6 Hazardous Area Classification Class 1, Div 2, Group D, T4


7 Ambient Temperature (deg C) Min: 25 Norm: 30 Max: 35
8 Humidity (% R.H) Min: 58 Norm: 88 Max: 99
9 Fluid Natural Gas
PROCESS DATA

10 Operating Pressure (Psig) Min: 800 Norm: 1000 Max: 1060


11 Operating Temperature (deg.F) Min: 90 Max: 105
12 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70
13 Design Pressure (Psig) Min: 0 Max: 1300
14 Design Temperature (deg.F) Min: -20 Max: 200
15 Methodology Proprietary auto carrier frontal elution sampling; non dispersive ultraviolet analysis
16 Accuracy Standard range: ±2% of full scale ; Low range: ±5% of full scale
17 Repeatability Standard range: ±2% of full scale
PERFORMANCE SPECIFICATIONS

18 Sample transport 1/4" SS instrument tubing


19 Typical flow Approx. 1 to 5Nl/min depending on sample conditioning system
20 Standard Range H2S: 0 to 25 ppm min
21 Zero Drift Standard range: less than ±2% of full scale in 24 hours
Low range: less than ±5% of full scale in 24 hours
22 Response Time Excluding Sampling System less than 30 seconds to 90% response
23 Sensitivity 0.5% of full scale
24 Process Pressure Requirement 120 psig to 2000 psig
25 Maximum Sample Cell Pressure 100 psig (6.9 barg)
26 Maximum Sample Gas Temperature 50ºC (122ºF)
27 Typical Flow 2.5 L/min. (5 SCFH)
28 Power 207 to 264 VAC, 47 to 63 Hz, < 2 A
29 Power consumption <500 W (excluding sample & vent line)
ELECTRONICAL

30 Outputs Up to 4 isolated 4-to-20 mA, loop or self-powered;


31 Communication 4 non-isolated 1 to 5 VDC; 5 independent sets of SPDT
Form C, potential free alarm relay contacts, 2 A at 240 VAC
32 Digital Communication RS485 Modbus port; RS232/RS485 service port
33 Dimensions (H x W x D) 1185 x 780 x 254 mm (46.65 x 30.7 x 9.97 in.)
OTHER

34 Weight Approximately 100 kg (220.5 lbs)


35 Approvals ATEX II 2 G Ex d IIB T3 Gb
DATA SHEET
PRESSURE TRANSMITTER
PROJECT : SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV. DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review MC IP SER
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-007-PT
1 Tag Number PT 601A, PT 602A 32 Manufacture : Rosemount

PURCHASE
GENERAL

2 Service Custody Transfer Gas 33 Model No. : 3051 Series

3 P&ID No. HHI-EMP-P&ID-001 34 Serial No. : VTA

4 No of Units Required 2 35

5 Hazardous Area Classification Class 1, Div.1, Group D


SITE DATA

6 Ambient Temperature (deg C) Min: 15 Norm: 25 Max: 40

7 Humidity (% R.H) Min: 70 Norm: 82 Max: 98

8 Fluid Name Natural Gas


Operating Pressure (psig) Min: 800 Norm: 1060
PROCESS DATA

9 1000 Max:

10 Operating Temperature (deg.F) Min: 90 Max: 105

11 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70

12 Design Pressure (Psig) Min: 0 Max: 1300

13 Design Temperature (deg.F) Min: -20 Max: 200

14 Instrument Range 0 to 2000 psig 36 Accuracy ±0.075% of calibration span

15 Calibration Range 0 to 1300 psig 37 Stability ±0.2% of URL for 10 years

16 Elevation / Suppression No 38 Response Time 100 ms


17 Sensor Fill Fluid Silicone 39 Diaphragm 316 SS
TRANSMITTER

18 Enclosure Material Polyurethane Covered Alumunium

19 Process Connection 1/2" FNPT

20 Electrical Connection 1/2" NPT

21 Power Supply 24 VDC (Loop Powered)

22 Signal Output 4-20 mA + HART

23 Hazardous Area Certification FM Explosion Proof, Class 1 Div. 1 Grp. C & D


24 Ingress Protection NEMA 4X / IP66

25 Local Indicator / Scale LCD Type / Configurable in Eng. Units


26 2 Way Valve Manifold / Connection Size Yes, 316 SS / Direct Mount on Transmitter x 1/2" NPTF

27 Mounting Brackets 2" Pipe Mounted, 316SS


OPTIONS

28 Manifold Drain / Vent Plug Yes

29 Material Certification Yes, Material Traceability Certification per EN 10204 3.1B

30 Hydrostatic Testing with Certificate Yes

31 Calibration Certificate Yes


DATA SHEET
TEMPERATURE TRANSMITTER
PROJECT : SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV. DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review MC IP SER
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-008-TT
1 Tag Number TT 601B, TT 602B 35 Manufacture : Rosemount

PURCHASE
GENERAL

2 Service Custody Transfer Gas 36 Model No. : 3044 Series

3 P&ID No. HHI-EMP-P&ID-001 37 Serial No. : VTA

4 No of Units Required 2

Hazardous Area Classification Class 1, Div.1, Group D


SITE DATA

6 Ambient Temperature (deg C) Min: 15 Norm: 25 Max: 40

7 Humidity (% R.H) Min: 70 Norm: 82 Max: 98

8 Fluid Name Natural Gas


PROCESS DATA

9 Operating Pressure (psig) Min: 800 Norm: 1000 Max: 1060

10 Operating Temperature (deg.F) Min: 90 Max: 105

11 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70

12 Design Pressure (Psig) Min: 0 Max: 1300

13 Design Temperature (deg.F) Min: -20 Max: 200

14 Instrument Range 0 to 200 deg.F 36 Accuracy ±0.075% of calibration span

15 Calibration Range 0 to 150 deg.F 37 Diaphragm 316 SS

16 Mounting Direct to Thermowell

Enclosure Material Polyurethane Covered Alumunium


TRANSMITTER

17

18 Electrical Connection 1/2" NPT

19 Process Connection 1/2" NPT

20 Power Supply 24 VDC (Loop Powered)

21 Signal Output 4-20 mA + HART

22 Hazardous Area Certification FM Explosion Proof, Class 1 Div. 1 Grp. A, B, C & D


23 Ingress Protection NEMA 4X / IP66

24 Element Type RTD, Pt.100 Ohm, 4 Wire


ELEMENT

25 Material 316 SS

26 Mounting Brackets 2" Pipe Mounted, 316SS


THERMOWELL

27 Thermowell Construction Drilled Barstock Thermowell, Tapered, No Welding

28 Thermowell Material 316 SS

29 Insertion Length (U) 135 mm

30 Well Connection 1" ANSI 600 RF

31 Local Indicator / Scale LCD Type / 0 - 150 deg.F


OPTIONS

32 Wake Frequency Calculation Yes

33 Material Certification Yes, Material Traceability Certification per EN 10204 3.1B


34 Calibration Certificate Yes

1 All instrument shall be tagged with 316SS name plate.


2 Wake frequency shall not exceed 80% of natural frequency of the thermowell
NOTES

Calculation shall be performed to ASME PTC 19.3 latest edition.

3 Thermowell shall be stamped with the material, nominal "U" dimension and tag no.

4
DATA SHEET
PRESSURE INDICATOR
PROJECT : SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV. DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review MC IP SER
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-009-PI
1 Tag Number PG 601A, PG 602A 29 Manufacture : Wika

PURCHASE
GENERAL

2 Service Custody Transfer Gas 30 Model No. :

3 P&ID No. HHI-EMP-P&ID-001

4 No of Units Required 2

5 Hazardous Area Classification Class 1, Div.1, Group D


SITE DATA

6 Ambient Temperature (deg C) Min: 15 Norm: 25 Max: 40

7 Humidity (% R.H) Min: 70 Norm: 82 Max: 98

8 Fluid Name Natural Gas


Operating Pressure (psig) Min: 800 Norm: 1060
PROCESS DATA

9 1000 Max:

10 Operating Temperature (deg.F) Min: 90 Max: 105

11 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70

12 Design Pressure (Psig) Min: 0 Max: 1300

13 Design Temperature (deg.F) Min: -20 Max: 200

14 Type Direct Reading

15 Range (psig) 0 - 1200

16 Mounting Direct

17 Dial Diameter 6"

18 Case SS 316

19 Ring Standard
CONSTRUCTION

20 Blowout Protection Rear, Disc

21 Lens Safety Glass

22 Nominal Accuracy Required ± 0.5% of Full Scale

23 Pressure Element Bourdon


24 Element Material 316 SS

25 Standard Connection 1/2" NPT Male Screwed


26 Movement SS

27 Fluid Glycerine
28 Protection Weather Proof

1 All instrument shall be tagged with 316SS name plate, hard stamped with the instrument tag no.

2 White Back Ground with Black Figure


NOTES

3 Pressure Gauge shall calibrate in psi


DATA SHEET
TEMPERATURE INDICATOR
PROJECT : SENG SEGAT PHASE 3 DEVELOPMENT
PT. HANDIYAN
REV. DATE DESCRIPTION
PREP'D BY CHK'D BY APP'D BY
A 08-Jun-18 Issued For Review MC IP SER
Contractor : PT. Handiyan Hulu Instrumen CLIENT
Client : EMP Bentu Ltd. CHK'D APP'D
Document No : HHI-EMP-DS-010-TI
1 Tag Number TG 601B, TG 602B 30 Manufacture : Wika

PURCHASE
GENERAL

2 Service Custody Transfer Gas 31 Model No. : S5550

3 P&ID No. HHI-EMP-P&ID-001

4 No of Units Required 2

5 Hazardous Area Classification Class 1, Div.1, Group D


SITE DATA

6 Ambient Temperature (deg C) Min: 15 Norm: 25 Max: 40

7 Humidity (% R.H) Min: 70 Norm: 82 Max: 98

8 Fluid Name Natural Gas


Operating Pressure (psig) Min: 800 Norm: 1060
PROCESS DATA

9 1000 Max:

10 Operating Temperature (deg.F) Min: 90 Max: 105

11 Operating Flow Rate (MMSCFD) Min: 30 Norm: 60 Max: 70

12 Design Pressure (Psig) Min: 0 Max: 1300

13 Design Temperature (deg.F) Min: -20 Max: 200

14 Stem Threaded

15 Stem Material 316 SS

16 Stem or Union Thread 1/2"

17 Stem Diameter Standard


THERMOMETER

18 Dial Size 5"

19 Form Every Angle

20 Protection Weather Proof

21 Lens Safety Glass

22 Nominal Accuracy Required ± 0.5% of Full Scale

23 Range (deg.F) 0 - 150


24 Standard Connection 1/2" NPT Male

25 Include Yes
THERMOWELL

26 Material 316 SS

27 Construction Drilled Bar Stock

28 Inst. Connection 1/2" NPT

29 Well Connection 1" ANSI 600 RF

1 All instrument shall be tagged with 316SS name plate, hard stamped with the instrument tag no.
2 Dial Shall be White Back Ground with Black Figure
NOTES

3 All wetted Part material shall comply to nACE Standard MR-0175

4 The Thermowell length and bore diameter shall match elements stem length and stem diameter

You might also like