You are on page 1of 2

Fast Deployment

Reliable Running

Intelligent Management

Refarming

One-stop Site Solution


Site Construction Once for N-year Usage

Fast Deployment
◆ Flexible cabinet expansion, 0 site application

◆ All-in-One cabinet, site installation in 1 day

◆ Remote power supply, fast power on in 3 days

Reliable Running
◆ One-stop design, 100+ professional tests
◆ Stable running for 20 years under global hash
environment

◆ 800-W natural cooling, super mute


Experience more documents
OUTDOOR CABINET
Intelligent Management
◆ Intelligent battery management, 0 onsite visit
for maintenance and reduced OPEX by 20%

◆ Uniform NMS, 100% component management


◆ Intelligent security for anti-theft http://support.huawei.com
networkinfo@huawei.com
Refarming
◆ Flexible compartment expansion, smooth expansion
◆ Rate speedup at original sites: SuperVector/
G.fast/FTTH
◆ Refarming: transport, datacom, and mobile
◆ Reduced costs for the future evolution by 80% Copyright © Huawei Technologies Co.,Ltd. ALL rights reserved.
Small-capacity outdoor cabinet Medium-and large-capacity outdoor cabinet RPS Solution
F01S300 400-700-line Medium-capacity RPS RFT-V Series Solution
F01C100B Low Noise Mini Network Box
Installed in Corridors Light-weighted Cabinet ◆ Comprehensive protection for human being safety ◆ High energy efficiency
Meets IEC/EN60950-21 International security standards 93% conversion efficiency; supports multiple-pair-mode RPS
Flexible site Compact design with a depth of 235 mm for corridor installation. Ultra mute design < 45 dBA/day, < 35 dBA/night Intelligent fan speed adjustment. for fast protection against short circuit, open circuit, and for line loss reduction; supports intelligent fan speed adjustment.
selection leakage to ensure human being safety.
Light-weighted and one-door design with handles on both left Enclosure design, IP55, 40 kA surge protection, aluminum sheets, and ◆ High density and large capacity ◆ Unified NMS
Easy installation High reliability 20-year anti-corrosion performance,electronic door lock management. CO 3 U subrack supports up to 3528 W power and Unified NMS for both the power supply system and devices to
and right sides for easy lifting and installation.
supports 9 cascaded subracks. reduce difficulties in service deployment and provisioning.
Eco-friendly and Heat dissipation without fans, featuring zero power Wall Humanized design Illuminator for nighttime maintenance, diesel generator interface, Concrete foundation RPC018-V(3U) RPC004-V(1U) RPR006-V(1U)
energy-saving consumption, low noise, and no maintenance. (indoor corridor) maintenance socket, and authority-based maintenance. or elevated platform
Subrack
Dimensions (H x W x D) 925 mm x 630 mm x 235 mm Dimensions (H x W x D) 1350 mm x 850 mm x 450 mm
Maximum weight Dimensions (H×W×D) 130.5 mm x 442 mm x 312 mm 43.6 mm x 442 mm x 312 mm 43.6 mm x 442 mm x 312 mm
Maximum weight 140 kg/280 kg
(without/with batteries) 31.5 kg/54.5 kg (without/with batteries) 18/16 (with monitoring module)
Configuration up converters 4 up converters 6 down converters
Power supply AC; 12 Ah (one set of four batteries in series connection) Power supply ETP4830, RPS; 50 Ah or 100 Ah (one set of four batteries in series connection) Maximum output
power for a subrack 3528 W (36 circuits of output) 784 W (8 circuits of output) 1800 W (24 circuits of output)
Heat dissipation Direct ventilation, 310 W/45 ℃
Heat dissipation Heat exchanger, 1000 W/50 ℃ Rectifier module Up converter Down converter
Noise standard ETS 300753 Class 4.1E rural level Capacity 2 circuits of output per module 4 circuits of output per module
Noise standard ETS 300753 Class 4.1E rural level
1*AC MA5610/MA5616/MA5818, Voltage Input voltage: -40 to -72 V DC Input voltage: 190 to 380 V DC
Devices involved 2*AC MA5623A/MA5620/MA5626/MA5821/MA5822/MA5878 Devices involved 1*DC MA5603T(OLT/MSAN), 3*DC MA5616(Limited) Output voltage: Rate voltage: ±190 V DC; Maximum voltage: ±192 V DC Output voltage: -52 to -56 V DC
Maximum output 98 W 75 W
power of a circuit
Module conversion

F01S50 F01T300
≥ 93% (full load) ≥ 92% (full load)
64-line Mini Outdoor 400-700-line Medium-capacity efficiency

Cabinet in Natural Heat Dissipation Outdoor Cabinet


Modular design, expandable space (side compartment/
RPS RFT-C Series Solution
Ultra mute design < 45 dBA/day, < 35 dBA/night Installed in residential communities. Superb scalability
Topbox), expansion in the original site, reducing TCO. ◆ Comprehensive protection for human being safety
Meets IEC/EN60950-21 International security standards for fast protection against short circuit, open circuit, and leakage to
Eco-friendly and Natural heat dissipation without fans and air filter, reducing Supports copper wires, fibers, and the hybrid onfiguration of ensure human being safety.
energy-saving OPEX by 80%. Simple evolution copper wires and fibers to facilitate future network evolution.
◆ High energy efficiency ◆ High density and large capacity
92% conversion efficiency; intelligent fan speed Unified NMS for both the power supply system and devices to
Easy installation Features a small volume and light weight to facilitate installation. Pole or wall All-component monitoring, electronic door lock management, Concrete foundation
Intelligent features and visible remote U2000 O&M, reducing OPEX by 30%. or elevated platform adjustment. reduce difficulties in service deployment and provisioning.
RPC018-C(3U) RPC004-C(1U) RPR008S-C
Dimensions (H x W x D) 850 mm x 560 mm x 200 mm Dimensions (H x W x D) 1350 mm x 850 mm x 450 mm Subrack
Maximum weight Maximum weight
(without/with batteries) 38 kg/66 kg 185 kg/325 kg
(without/with batteries)
Dimensions (H×W×D) 130.5 mm x 442 mm x 312 mm 43.6 mm x 442 mm x 312 mm 70 mm x 250 mm x 185 mm
Power supply AC; 12 Ah (one set of four batteries in series connection) Power supply ETP4830/ETP4890, RPS; 50 Ah or 100 Ah (one set of four batteries in series connection)
Configuration 18/16 (with monitoring module) 4 up converters 1 down converter
Heat dissipation Natural heat dissipation, 120 W/50 ℃ up converters
Heat dissipation Heat exchanger, 1500 W/50 ℃, 1000 W/55 ℃
Maximum output 3136 W (144 circuits of output) 696 W (32 circuits of output) 150 W (8 circuits of output)
Noise standard ETS 300753 CLASS 4.1 protected area level Noise standard ETS 300753 Class 4.1E rural level power for a subrack
Rectifier module Up converter Down converter
Devices involved 1*AC MA5622A/MA5623/MA5623A/MA5612/MA5616 Devices involved 1*DC MA5800-X7/MA5603T (OLT/MSAN), 3*DC MA5616 (Limited)
Capacity 8 circuits of output per module 8 circuits of output per module
Input voltage: -40 to -72 V DC Input voltage: -36 to -72 V DC Input voltage: 240 to 380 V DC
Voltage
Output voltage: 340 to 380 V DC Output voltage: 340 to 380 V DC Output voltage: -52 to -56 V DC

F01S100 192-line Small-capacity Outdoor


Cabinet Featuring Security and Flexibility
F01T500 1000-line Large-capacity
Outdoor Cabinet
Maximum output
power of a circuit 22 W NA
Module conversion ≥ 92% (full load) ≥ 92% (full load)
efficiency
Ultra mute design < 45 dBA/day, < 35 dBA/night, Installed in residential communities.
Superb scalability
Modular design, expandable space (side compartment/Topbox),
expansion in the original site, reducing TCO.
Enclosure design

Optical access evolution


IP55, no air filter, no routine maintenance, reducing OPEX by 80%.

Supports MA5608T OLT optical access evolution.


Simple evolution Scalable heat exchanger for high-speed service evolution;
copper-fiber hybrid access for easy network evolution.
Configuration Capacity
Wall, pole, or All-component monitoring, electronic door lock management, Concrete foundation
Easy installation Features a small volume and high density to facilitate
concrete foundation
Intelligent features and visible remote U2000 O&M, reducing OPEX by 30%. or elevated platform
Networking
scenarios Solution Maximum Capacity
installation.
F01C100B + 2*AC MA5620/MA5626 48 FE + 48 POTS
Dimensions (H x W x D) 1110 mm x 670 mm x 250 mm Dimensions (H x W x D) 1600 mm x 1350 mm x 480 mm F01C100B + 2*AC MA5878 48 GE + 96 POTS
FTTB+LAN
Maximum weight Maximum weight F01S50 + 1*AC MA5612 22 FE; 48 POTS
(without/with batteries) 50 kg/74.5 kg 250 kg/518 kg
(without/with batteries) F01S100 + 2*AC MA5620 48 FE + 48 POTS
Power supply AC, ETP4830, RPS; 12 Ah (one set of four batteries in series connection) Power supply ETP4890/ETP48150, RPS; 100 Ah (two sets; can be expanded to 400 Ah) F01C100B + 2*AC MA5622A/MA5623A 96 V+V; 48 VD Combo
Heat dissipation Natural heat dissipation: 200 W/50 ℃; enhanced heat dissipation: 315 W/50 ℃ or 245 W/55 ℃ Heat dissipation Heat exchanger, 2000 W/50 ℃ F01C100B + 1*AC MA5616/MA5818 256 POTS; 128 VD/V+V/SV/AD/AD Combo; 144 SV; 72 G.fast

Noise standard ETS 300753 Class 4.1E protected area level F01S50 + 1*AC MA5616/MA5622A/MA5623A/ 64 POTS/AD/VD/AD Combo/VD Combo; 48 VD;
Noise standard ETS 300753 Class 4.1E urban level MA5612 24 VD Combo
Devices involved 1*AC/DC MA5616(Limited)/MA5818, 1*AC MA5608T, 2*AC MA5620/MA5626 Devices involved 1*DC MA5600T/MA5603T (OLT/MSAN), MA5800-X17/MA5800-X7 256 POTS; 192 AD/VD;
F01S100 + 1*AC/DC MA5616/MA5818 144 V+V/SV/VD Combo/SV Combo; 128 AD Combo

F01S200 + 1*DC MA5616 256 POTS/AD/VD/V+V; 192 SV/VD Combo/SV Combo;

F01S200 256-line Small-capacity Outdoor


Cabinet Featuring Security and Flexibility
F01D2000 2000-line Super-large-capacity
Outdoor Cabinet FTTB/C+DSL F01S300 + 3*DC MA5616
128 AD Combo; 96 G.fast
768 POTS; 640 AD/VD/V+V; 384 AD Combo;
576 VD Combo/V+V Combo; 192 SV Combo
Ultra mute design < 45 dBA/day, < 35 dBA/night, installed in residential communities. Large capacity 2 MA5600T subracks, up to 2048 lines. F01S300 + 1*DC MA5603T 384 POTS/AD/VD/V+V/SV/V+V Combo/VD Combo;
288 AD Combo
High reliability Enclosure design, IP55, low fault rate; no air filter and no routine Dual head exchanges and dual fans; IP55; 60 kA surge F01T300 + 3*DC MA5616
768 POTS; 640 AD/VD/V+V; 384 AD Combo;
and no maintenance maintenance, reducing OPEX by 80%, electronic door lock management. High reliability protection,electronic door lock management. 576 VD Combo/V+V Combo; 480 SV; 192 SV Combo
384 POTS/AD/VD/V+V/SV/V+V Combo/VD Combo;
Optical access evolution F01T300 + 1*DC MA5603T
Supports MA5608T OLT optical access evolution. Automatically adjusts the speed of fans. The fans run at a 288 AD Combo
Eco-friendly and low speed under normal temperature conditions, attaining Mounted on a
Concrete foundation, wall, 1024 VD/AD/POTS/VD Combo;
Flexible deployment Features a small volume and high density to energy-saving low noise and low power consumption. concrete base F01T500 + 1*MA5600T/MA5603T 768 V+V/AD Combo; 384 SV
facilitate installation. pole, or elevated platform
2048 POTS; 1792 AD/VD/VD Combo;
F01D2000 + 2*MA5600T
Dimensions (H x W x D) 1200 mm x 750 mm x 350 mm Dimensions (H x W x D) 1850 mm x 1750 mm x 800 mm 1536 AD Combo; 768 V+V Combo
Maximum weight F01S100 + 1*AC MA5608T 32 PON
Maximum weight 72 kg/147 kg (without/with batteries) 550 kg/950 kg
(without/with batteries) F01S200 + 1*DC MA5608T/MA5800-X2 32 PON/10G GPON; 48 GE
Power supply ETP4830, RPS; 26 Ah or 40 Ah (one set of four batteries in series connection) Power supply ETP48150; RPS; 150 Ah (two sets) FTTB/C+PON F01S300 + 1*DC MA5603T 96 PON; 48 GE
F01T300 + 1*DC MA5800-X7/MA5603T 112 PON/10G GPON; 288 GE
Heat dissipation Natural heat dissipation: 350 W/45 ℃, 265 W/50 ℃; Heat dissipation Heat exchanger, Max 3800 W/50 ℃
enhanced heat dissipation: 580 W/50 ℃, 400 W/55 ℃ F01T500 + 1*DC 272 PON/10G GPON; 768 GE
Noise standard ETS 300753 Class 4.1E urban level MA5600T/MA5603T/MA5800-X17/MA5800-X7
Noise standard ETS 300753 Class 4.1E rural level
AD: ADSL2+ AD Combo: ADSL2+ & POTS V+V Combo: Vectoring & POTS SV: SuperVector
Devices involved 1*DC MA5616/MA5608T/MA5818/MA5800-X2 Devices involved 2*DC MA5600T, 2*DC HABD + 1*DC HABF
VD: VDSL2 VD Combo: VDSL2 & POTS V+V: Vectoring

You might also like