You are on page 1of 16

PROTEC TI O N A N D CO N N EC TI O N

ATEX enclosed safety switches


Designed for a potentially
explosive atmosphere
2
3


Table of contents

004 – 006 Overview

009 Type designation key

010 – 011 Technical data

013 Dimension drawings


4 AT E X E N C L O S E D S A F E T Y S W I T C H E S D E S I G N E D F O R A P OT E N T I A L LY E X P LO S I V E AT M O S P H E R E


ATEX approved switches
Designed for a potentially explosive
atmosphere
ATEX enclosed safety switches are designed to a potentially explosive
atmosphere and are made according to ATEX directive 2014/34/EU. A
potentially explosive atmosphere exists when a mixture of air gases,
vapours, mists, or dusts combine in a way that can ignite under certain
operating conditions. Typical applications for ATEX switches are
refineries, mills, conveyor belt in hazardous areas, and dusty
environments. Our ATEX enclosed safety switches support you in
creating a safe working environment, reducing the risk of electrical
and mechanical accidents, especially during maintenance and repair
work.

Ex tc III T70⁰C Dc
AT E X e c l o s e d s w i tc h e s a r e m a d e
a c c o r d i n g to AT E X c l a ss f o r e n c l o s e d
s w i tc h e s . M e a n i n g t h at t h e y a r e
explosion proof equipment, made for
zo n e 2 2 , e n d u r e c o n d u c t i v e d u s t , a n d
w i t h s t a n d te m p e r at u r e m a x 7 0 ⁰ C o f
t h e e x p o s e d s u r f a c e . T h e s p e c i f i c at i o n
o f zo n e 2 2 i s : e x p l o s i v e at m o s p h e r e
i s n o t l i ke l y to o c c u r, a n d i f i t d o e s
o c c u r, i t i s o n l y f o r a s h o r t t i m e .
OVERVIE W 5

Reliable in extreme conditions Safety and protection Easy to buy and install
R i g i d a n d w e l l p r ove n d e s i g n ABB puts safety first ABB is a one -stop -shop
T h e AT E X e n c l o s e d s af e t y Our design is based on ensuring for enclosed switches
s w i tc h e s a r e b u i l t to l a s t s af e t y a n d p r e v e n t i n g e l e c t r i c a l ABB has made the purchase
and resist the wear of harsh a c c i d e n t s . We h av e i n c l u d e d a n d i n s t a l l at i o n e a s y f o r AT E X
o p e r at i n g c o n d i t i o n s . T h e y a r e f e at u r e s s u c h a s c o v e r i n te r l o c k s e n c l o s e d s af e t y s w i tc h e s .
m a d e a c c o r d i n g to AT E X c l a ss a n d g a s p r e ss u r e r e l i e f f u n c t i o n The deliver y includes handle
f o r e n c l o s e d s w i tc h e s E x tc I I I to m a ke m ai n te n a n c e a n d ( I - O/O N - O F F ), P E - te r m i n a l ,
T 7 0 ⁰ C D c , w h i c h m e a n s t h at t h e y i n s t a l l at i o n a s s af e a s p o ss i b l e . threaded cable entries, cable
a r e d e s i g n e d to a p o te n t i a l l y glands for two cables and one
e x p l o s i v e at m o s p h e r e . T h e control cable, cable entr y plugs,
enclosures are made of high - and 1NO aux iliar y contact for
q u a l i t y, U V - r e s i s t a n t m ate r i a l s d i s c o n n e c t i o n o r a n n u n c i at i o n .
a n d t h e d e g r e e o f p r o te c t i o n i s
IP65 making them suitable for
b o t h i n d o o r s a n d o u td o o r s . T h e y
are also EMC approved and can
be used in env ironments w ith
elec tromagnetic disturbances.
6 AT E X E N C L O S E D S A F E T Y S W I T C H E S D E S I G N E D F O R A P OT E N T I A L LY E X P LO S I V E AT M O S P H E R E


ATEX enclosed safety switches
Safe and dependable performance
ATEX enclosed safety switches in demanding operating conditions
help ensure that machinery can’t be accidentally started while
maintenance is in progress. Safety and dependable performance has
been taken into consideration in every aspect of their design.

Tr i e d a n d t e s t e d p e r f o r m a n c e
We o f f e r I EC s t a n d a r d AC s w i tc h e s f r o m 1 6 to 1 2 5
A m p e r e s , w i t h p o w e r r at i n g s f r o m 7. 5 to 4 5 k W
u p to 6 9 0 V. T h e r at i n g s c o r r e s p o n d to u t i l i z at i o n
c ate g o r y AC - 2 3 A . AT E X e n c l o s e d s af e t y s w i tc h e s
a r e av ai l a b l e i n 3 - , 4 - a n d 6 - p o l e v e r s i o n s .
T h e y a r e f r o n t- o p e r ate d a n d h av e i n te r l o c ke d
c o v e r. T h e e n c l o s u r e i s d y e c a s te d a l u m i n i u m .

A l l o u r s af e t y s w i tc h e s h av e b e e n te s te d
a c c o r d i n g to I EC 6 0 9 47- 3 s t a n d a r d . A f te r r i g o r o u s
te s t i n g , o u r s af e t y s w i tc h e s h av e p r o v e n to
m ai n t ai n a h i g h d e g r e e o f s af e t y. O u r s af e t y
s w i tc h e s a r e d e l i v e r e d w i t h a n a u x i l i a r y c o n t a c t
t h at c a n b e u s e d f o r e l e c t r i c a l i n te r l o c k i n g .
T h i s i s d o n e b y c o n n e c t i n g t h e s af e t y s w i tc h
to a s t a r te r o r o t h e r m o to r c o n t r o l d e v i c e s . F o r
e a s y i d e n t i f i c at i o n , e a c h s af e t y s w i tc h h a s a
s t i c ke r l a b e l . F o r t h e m o s t e x t r e m e o p e r at i o n a l
c o n d i t i o n s , c o r r o s i o n - r e s i s t a n t g o l d p l ate d
a u x i l i a r y c o n t a c t s a r e av ai l a b l e u p o n r e q u e s t .

Ensured EMC safety


A B B ’s d e s i g n a l s o t a ke s i n to c o n s i d e r at i o n t h e
need for reliable per formance in env ironments
w i t h e l e c t r o m a g n e t i c d i s t u r b a n c e s ( E M C ), i n
f u l l c o m p l i a n c e w i t h E N 5 5 0 1 1 , a c c o r d i n g to
E U d i r e c t i v e 2 0 0 4/ 1 0 8/ EC . E l e c t r o m a g n e t i c
c o m p at i b i l i t y ( E M C ) r e f e r s to t h e a b i l i t y o f a
d e v i c e to f u n c t i o n d e s p i te e l e c t r o m a g n e t i c
disturbances in the env ironment w ithout
elec tromagnetically disturbing other dev ices in its
surroundings. This is impor tant in env ironments
w h e r e t h e d i s t u r b a n c e f r o m f r e q u e n c y c o n v e r te r s
m ay r i s e u p to te n s o f, o r e v e n h u n d r e d s o f M H z .
7
8 AT E X E N C L O S E D S A F E T Y S W I T C H E S D E S I G N E D F O R A P OT E N T I A L LY E X P LO S I V E AT M O S P H E R E


Type designation key
ATEX enclosed safety switches


Type codes

Understanding the type codes below will help you to quickly identify the correct product for
your needs. The simple naming system allows you to see the product type, ampere, rating,
standard classification and number of poles – all in one glance.

Explanation of types OTA16...125 A

O T A 1 6 S 3 B X
Type of switch
OT = Safety switch

Enclosure material
A = Aluminum

Switch size / Ampere rating


16...125 A (AC22A)

Handle type
S = Selector handle

Number of poles
3-, 4-, 6-pole

Colour
Y = Red-yellow handle, grey cover
B = Black handle, grey cover

EMC and ATEX application


X = EMC and ATEX
9
10 AT E X E N C L O S E D S A F E T Y S W I T C H E S D E S I G N E D F O R A P OT E N T I A L LY E X P LO S I V E AT M O S P H E R E


Technical data
ATEX enclosed safety switches


ATEX enclosed safety switches, 3, 4 and 6-pole, IP65, black handle

The delivery includes a black handle (I-O/ON-OFF), PE-terminal, threaded cable entries, cable
glands for two cables and one control cable, cable entry plugs, and auxiliary contacts
according to the table below. Enclosure in rigid dye casted aluminium. Safety switch sticker
included.

The products are all EMC approved. EMC glands to be ordered separately.

Cable entries from top and bottom


Max. motor Cable Dimensions Type Order code Weight
output outlets / side (1 pce)
AC-23A
415 V 690 V Height Width Depth
kW / A kW / A mm mm mm kg

3-pole
OTA16S3BX
Auxiliary contacts included: 1NO0NC. Auxiliary contacts max: 2NO2NC.
7.5 / 16 7.5 / 10 2xM25+M20 / 2xM25+M20 165 130 131 OTA16S3BX 1SCA152716R1001 1.3
9 / 20 9 / 11 2xM25+M20 / 2xM25+M20 165 130 131 OTA25S3BX 1SCA152722R1001 1.3
OTA63S3BX
11 / 23 11 /12 2xM32+M20 / 2xM32+M20 165 130 131 OTA40S3BX 1SCA152728R1001 1.3
22 / 63 15 / 20 2xM40 / 2xM40+M16 230 160 145 OTA63S3BX 1SCA152734R1001 1.8
37 / 75 18.5 / 20 2xM40 / 2xM40+M16 230 160 145 OTA80S3BX 1SCA152738R1001 1.8
37 / 75 37 / 40 2xM40 / 2xM40+M16 230 160 145 OTA100S3BX 1SCA152697R1001 1.8
45 / 90 45 / 50 2xM40 / 2xM40+M16 230 160 145 OTA125S3BX 1SCA152712R1001 1.8

4-pole
Auxiliary contacts included: 1NO0NC. Auxiliary contacts max: 2NO2NC.
7.5 / 16 7.5 / 10 2xM25+M20 / 2xM25+M20 165 130 131 OTA16S4BX 1SCA152718R1001 1.3
OTA25S4BX 9 / 20 9 / 11 2xM25+M20 / 2xM25+M20 165 130 131 OTA25S4BX 1SCA152724R1001 1.3
11 / 23 11 /12 2xM32+M20 / 2xM32+M20 165 130 131 OTA40S4BX 1SCA152730R1001 1.3
22 / 63 15 / 20 2xM40 / 2xM40+M16 230 160 145 OTA63S4BX 1SCA152736R1001 1.8
OTA80S4BX
37 / 18.5 18.5 / 20 2xM40 / 2xM40+M16 230 160 145 OTA80S4BX 1SCA152740R1001 1.8
37 / 80 37 / 40 2xM40 / 2xM40+M16 230 160 145 OTA100S4BX 1SCA152710R1001 1.8
45 / 90 45 / 50 2xM40 / 2xM40+M16 230 160 145 OTA125S4BX 1SCA152714R1001 1.8

6-pole
Auxiliary contacts included: 1NO0NC. Auxiliary contacts max: 2NO2NC.
7.5 / 16 7.5 / 10 2xM25 / 2xM25+M16 230 160 145 OTA16S6BX 1SCA152720R1001 1.8
9 / 20 9 / 11 2xM25 / 2xM25+M16 230 160 145 OTA25S6BX 1SCA152726R1001 1.8
11 / 23 11 / 12 2xM32 / 2xM32+M16 230 160 145 OTA40S6BX 1SCA152732R1001 1.8

OTA40S6BX
T E C H N I C A L D ATA 11


Technical data
ATEX enclosed safety switches


ATEX enclosed safety switches, 3, 4 and 6-pole, IP65, red-yellow handle

The delivery includes a red-yellow handle (I-O/ON-OFF), PE-terminal, threaded cable entries,
cable glands for two cables and one control cable, cable entry plugs, and auxiliary contacts
according to the table below. Enclosure in rigid dye casted aluminium. Safety switch sticker
included.

The products are all EMC approved. EMC glands to be ordered separately.

Cable entries from top and bottom


Max. motor Cable Dimensions Type Order code Weight
output outlets / side (1 pce)
AC-23A
415 V 690 V Height Width Depth
kW / A kW / A mm mm mm kg

3-pole
OTA16S3YX
Auxiliary contacts included: 1NO0NC. Auxiliary contacts max: 2NO2NC.
7.5 / 16 7.5 / 10 2xM25+M20 / 2xM25+M20 165 130 131 OTA16S3YX 1SCA152717R1001 1.3
9 / 20 9 / 11 2xM25+M20 / 2xM25+M20 165 130 131 OTA25S3YX 1SCA152723R1001 1.3
OTA100S3YX
22 / 23 11 / 12 2xM32+M20 / 2xM32+M20 165 130 131 OTA40S3YX 1SCA152729R1001 1.3
22 / 63 15 / 20 2xM40 / 2xM40+M16 230 160 145 OTA63S3YX 1SCA152735R1001 1.8
37 / 75 18.5 / 20 2xM40 / 2xM40+M16 230 160 145 OTA80S3YX 1SCA152739R1001 1.8
37 / 80 37 / 40 2xM40 / 2xM40+M16 230 160 145 OTA100S3YX 1SCA152709R1001 1.8
45 / 90 45 / 50 2xM40 / 2xM40+M16 230 160 145 OTA125S3YX 1SCA152713R1001 1.8

4-pole
Auxiliary contacts included: 1NO0NC. Auxiliary contacts max: 2NO2NC.
7.5 / 16 7.5 / 10 2xM25+M20 / 2xM25+M20 165 130 131 OTA16S4YX 1SCA152719R1001 1.3
OTA25S4YX 9 / 20 9 / 11 2xM25+M20 / 2xM25+M20 165 130 131 OTA25S4YX 1SCA152725R1001 1.3
11 / 23 11 / 12 2xM32+M20 / 2xM32+M20 165 130 131 OTA40S4YX 1SCA152731R1001 1.3
22 / 63 15 / 20 2xM40 / 2xM40+M16 230 160 145 OTA63S4YX 1SCA152737R1001 1.8
OTA125S4YX 37 / 75 18.5 / 20 2xM40 / 2xM40+M16 230 160 145 OTA80S4YX 1SCA152741R1001 1.8
37 / 80 37 / 40 2xM40 / 2xM40+M16 230 160 145 OTA100S4YX 1SCA152711R1001 1.8
45 / 90 45 / 50 2xM40 / 2xM40+M16 230 160 145 OTA125S4YX 1SCA152715R1001 1.8

6-pole
Auxiliary contacts included: 1NO0NC. Auxiliary contacts max: 2NO2NC.
7.5 / 16 7.5 / 10 2xM25 / 2xM25+M16 230 160 145 OTA16S6YX 1SCA152721R1001 1.8
9 / 20 9 / 11 2xM25 / 2xM25+M16 230 160 145 OTA25S6YX 1SCA152727R1001 1.8
11 / 23 11 / 12 2xM32 / 2xM32+M16 230 160 145 OTA40S6YX 1SCA152733R1001 1.8

OTA40S6YX
12
DIMENSION DR AWINGS 13


Dimension drawings
ATEX enclosed safety switches

W
W
X
X

ØG ØG
A A

H B H B

D
D
Y
Y

W
W
X
X

ØG ØG
A A

H B H B

D
D
Y
Y

Dimensions Cable entry Fixing dimensions Dimensions Cable entry Fixing dimensions
mm mm mm mm
H W D X Y A B G H W D X Y A B G
OTA16...25 OTA63...125
3- and 4-pole 3- and 4-pole
165 130 131 2xM25+M20 2xM25+M20 95 125 6.5 230 160 145 2xM40 2xM40+M16 124 190 5.3
OTA40 OTA16...25
3- and 4 pole 6-pole
165 130 131 2xM32+M20 2xM32+M20 95 125 6.5 230 160 145 2xM25 2xM25+M16 124 190 5.3
OTA40
6-pole
230 160 145 2xM32 2xM32+M16 124 190 5.3
14

Additional information
We reserve the right to make technical
changes or modify the contents of this
document without prior notice. With
regard to purchase orders, the agreed
particulars shall prevail. ABB Oy does
not accept any responsibility whatso-
ever for potential errors or possible lack
of information in this document.

We reserve all rights in this document


and in the subject matter and illustra-
tions contained therein. Any reproduc-
tion, disclosure to third parties or
utilization of its contents – in whole or
in parts – is forbidden without prior
written consent of ABB Oy.
15

ABB Oy
Protection and connection
P.O. Box 622
FI-65101 Vaasa, Finland

www.abb.com

Find the address of your local sales


organization
on the ABB homepage:

www.abb.com/contacts
> Low Voltage Products and Systems
ATEX enclosed safety switches brochure, OTA16GB_18-05, 1SCC340013C0201

© Copyright 2018 ABB. All rights reserved.


Specifications subject to change without notice.

You might also like