ENKON PROFILE

PLANT INTEGRITY INSPECTION


AND NDT SERVICES
PREPARED BY
FILIZ OZTASKIN-COUNTRY MANAGER
RAJENDRAN CHETTIAR – PROJECT MANAGER
ENKON END.KON.KAY.SAN.VE TIC.LTD.STI.
STREET # 62 HOUSE # 22 MANAWY BASHA,

BASRA, IRAQ

TEL: +964 780 416 81 92

Web: www.enkon.com.tr

E-mail: enkon@enkon.com.tr
EXECUTIVE SUMMARY

 Enkon was estabilished in 1991, with it’s head office in Tuzla,Istanbul,Turkey


 ENKON has a branch in Iraq Basra, Azerbaijan,Kuveyt,UEA and a sister concern
KAZEN in Kazakhstan Atyrau.
 Our company primarily focuses on engineering inspection services with special
emphasis in the NDT sector. Enkon cater to a wide range of industries including
the oil, gas, energy, power, offshore and marine sector, petrochemical and
nuclear.
 As a service oriented company, we give great importance to quality through
our team of qualified professionals. All Enkon employees possess specific
qualification related to their respective roles and have extensive experience in
their fields to supervise and inspect various engineering projects.
CONTRACT EXECUTION SUMMARY-
RUMAILA SINCE 2011

 Current Contract No. CN102170-NDT AND INTEGRITY INSPECTION WITH 2 TEAMS API
INSPECTION OF PRESSURE VESSELS AND PIPING. 3 TEAMS ADVANCED NDT INSPECTION OF
CORROSION MAPPING OF VESSELS, MFL OF STORAGE TANK BOTTOM, LRUT OF PIPING
 Contract No. CN101816-NDT SERVICES-WORKING WITH ONE TEAM PERFORMING RT, PAUT,
MT,PT,HARDNESS AND SOIL TESTING ACTIVITIES. GCMC TPI SERVICES.
 Contract No. CN101438-NDT SERVICES - WORKING WITH THREE TEAMS PERFORMING RT,
PAUT, MT,PT,HARDNESS AND SOIL TESTING ACTIVITIES
 Contract No. CN101132-NDT SERVICES - WORKING WITH THREE TEAMS PERFORMING RT,
PAUT, MT,PT,HARDNESS AND SOIL TESTING ACTIVITIES
 Contract No. CN100357-NDT SERVICES - WORKING WITH TWO TEAMS PERFORMING RT,UT,
MT,PT,HARDNESS TESTING.
SERVICE OFFERED OVERVIEW

Convetional NDT Services


 Radiography Testing
 Ultrasonic Testing
 Ultrasonic Thickness Measurement
 Magnetic Particle Testing
 Liquid Penetrant Testing
 Ferrite Measurement
 Visual Inspection
 Positive Material Idendification
 Hardness Testing
ADVANCED NDT SERVICES

Advanced NDT Services

 Time of Flight Diffraction ( ToFD) of welds


 Phased Array UT of welds
 Eddy Current Testing (ECT) of joints and tubes
 Video-scope Inspection Testing of pipe internals
 Radiography of cross-country pipeline by X-Ray Crawlers
 Magnetic Flux Leakage of Tank Bottom Plates
 Digital Radiography
 Automated Corrosion Mapping
 Long Range UT with Guided Wave Technique
OTHER SERVICES OFFERED

Other Services Offered

 Holiday Testing
 Vacuum Box Leak Test
 Blasting and Painting Inspection
 Hydrogen Attack Evaluation
 Welder Qualification Certification
 Welding Procedure Specification
 Post Weld Heat Treatment
 Soil Moisture/Density Testing by Troxler (Nuclear method)
OTHER SERVICES OFFERED

 PLANT INTEGRITY INSPECTION


 PRESSURE VESSEL INSPECTION AS PER API 510
 STORAGE TANK INSPECTION AS PER API 653
 PIPING INSPECTION AS PER API 570
 WELDING INSPECTION AS PER CSWIP 3.1, AWS-CWI AND APPLICABLE CODES
ASME SEC.VIII, SEC IX, ASME B31.3, B31.1, B31.4, AWS D1.1, API 1104
QA /QC INSPECTION

QA/QC Inspection

 GCMC services
 Safety and Environment Inspection.
 Electrical and Instrumentation Inspections.
 Other Inspections
MANPOWER RECRUITMENT & SUPPLY

Manpower Recruitment & Supply

 Welding Engineers
 Welding Inspectors
 Plant Inspectors
 QA/QC Inspectors
 NDT Technicians
 Welders
 Project Schedulers/Engineer
 Cost Estimator
AUTHORIZED AGENT FOR TURKEY

 ENKON is authorised agent of Sentinel and Kyung Do of South Korea to


Turkey Region to supply the following:
 Isotope Camera and container
 Isotopes
 NDT instruments and appliances, spares
 Services of NDT equipment.
ENKON EQUIPMENT CAPACITY FOR RUMAILA
DISCIPLINE NUMBERS EQUIPMENT
CORROSION MAPPING 2 SILVERWINGS-RMS

GAMMA RAY AS REQUIRED SENTINEL 880 DELTA

PAUT 1 GE PHASOR XS

TOFD & PAUT 3 OLYMPUS-OMNISCAN MX & ZETEC


TOPAZ 32
MT, PT AS REQUIRED KYUNGDO AC/DC

PWHT 2 WELDOTHERM STANDARD

LRUT TELETEST FOCUS 1 TELETEST FOCUS

HARDNESS TESTING 1 EQUOTIP 3

THICKNESS MEASUREMENT 1 SONA TEST T-GAGE IV

SOIL TESTING 1 TROXLER 3440

MFL FLOORMAP 3Di 1 SILVERWING

HYDROFORM SCANNER 2 OLYMPUS

UT MANUAL 4 SONATEST MASTERSCAN D70

Welding inspection Kit 2 GAL GAGE


CORROSION MAPPING RMS-2
PAUT-OLYMPUS-HYDROFORM SCANNER
TOFD & PAUT-OLYMPUS OMNISCAN
MX & ZETEC TOPAZ 32
PAUT-GE PHASOR XS
MANUAL UT-SONATEST MASTERSCAN
D70
LRUT-TELETEST FOCUS
MFL-STORAGE TANK BOTTOM PLATE
SCANNER
PWHT-WELDOTHERM STANDARD
PWHT-INSULATED JOINTS
ENKON MANPOWER IN RUMAILA
METHOD LEVEL PERSONNEL
SAFETY NEBOSH IGC N/A 1
GAMMA RAY III 3
GAMMA RAY II 5
GAMMA RAY I 4
PAUT II 8
TOFD II 6
MANUAL UT III 3
MT,PT III 3
MT,PT II 6
PWHT N/A 4
CORROSION MAPPING II 4
HARDNESS TESTING N/A 2
SOIL TESTING N/A 2
LRUT I 1
MFL II 4
PLANT
API 510, 570, 653 6
INSPECTOR
WELDING
CSWIP 3.1 6
INSPECTOR
ORGANISATION CHART
KEY PERSONNEL OF ENKON

 Sahin Cakmak – General Manager ( Turkey)


 Mustafa Cakmak – Deputy Manager (Turkey)
 Filiz Oztaskin – Country Manager (Iraq)
 Rajendran Chettiar – Project manager & Company NDT Level – III
STEPS TO ENHANCE QUALITY OF WORKS

ENKON is performing the NDT and PWHT services as per the requirements of the Clients. The following strategies are
followed to improve the Quality of NDT services.

 1. To have approved procedures for the discipline/technique to be undertaken in multi languages.

 2. To have adequately qualified technicians as per Company’s Specification to perform the respective NDT
service.

 3. To have adequate, suitable and calibrated equipment and instruments to perform the respective NDT service.

 4. Time based audit on the work place of technicians by Company Level – III or Company authorized
representative to observe the procedure compliance and safety compliance while working of the
technicians.

 5. Time based audit on document compliance for calibration certificates, equipment documents by Company
Level – III/authorized representative.

 6. Time based audit on equipment condition and performance by company Level – III/ authorized
representative.
STEPS TO ENHANCE QUALITY OF WORKS

 7. To ensure and encourage by the management with the work group to perform as a team.

 8. To make awareness with the work team the pros and cons of the errors/negligence if any with the
working procedure.

 9. To ensure by the management with the work group for good working atmosphere, adequate tools
and accessories are feed with.

 10. To ensure by Site Supervisor, after the NDT services, the observations and information are properly
recorded in log books and reported.

 11. Recording of re-work/negligence performed by each technician and analysis the cause for it and
rectify the same.

 12. If the re-work /negligence continue repeatedly by an individual / group of technicians adequate
actions like re-training/memo/suspension may be taken accordingly.
STEPS TO ENHANCE QUALITY OF WORKS

 13. To get updated information/revision from the Standards Institutions like ASME,
AWS, ASNT, API, EN, BS etc. and comply accordingly with the procedures.

 14. To get latest development in the testing equipment technology and update working
systems accordingly.

 15. To ensure by the management that NCR raised by audit are rectified and updated
with the systems.

COUNTRY MANAGER-IRAQ
HEALTH,SAFETY AND ENVIROMENT POLICY

Our goals/objectives are:

 “ALL ACCIDENTS CAN BE PREVENTED”


 Our Goal Is To Have A Zero Work Accident Rate, A Zero Environmental Incident Rate and Prevent All
Occupational Illnesses.
 Safety, Occupational Health And Environmental Affairs Are The Life Style For Our Employees.
 By Safety, Occupational Health And Environmental Affairs, ENKON & KAZ-EN Are Placed Amongst The Best
Performing Plants Worldwide.
 All Applicable Laws, Regulations And Standards Are Complied With.
 By Doing Environmental Effect Analysis In All Processes,All Negative Impacts are Eliminated Continuously.
 Educate All Employees About Employee Health and Safety Issues.
 This Policy Is The Responsibility Of All ENKON Employees And Contractors And Is An Integral Part Of Their
Contract.
ENKON SAFETY PROGRAM

 provision of physical safeguards


 provision of personal protective equipment
 regular program of inspection aimed at identifying and eliminating unsafe working
conditions and practices
 training of employees in safety procedures and in safe working practices with emphasis
on:
 personal conduct
 safety discipline
 accident reporting
 personal protection
 first aid
 attention to tools and equipment
ENKON SAFETY PROGRAM

 machines
 electricity
 compressed gases and fluids
 crane and forklift operation
 fire
 lifting and handling of materials
 materials storage
 operation of motor vehicles and accident reporting
 welding and cutting
 radiation safety
ENKON SAFETY PROGRAM

 the continual development and refinement of safety and health rules

 ensuring the adherence to safety and health rules

 the prompt investigation of every accident in order to avoid its recurrence

 the continual development and refinement of working procedures to


ensure safe working

 routine inspection and maintenance of equipment


ENKON STRATEGY ON LOCAL CONTENT

 Strategies for maximising local content.

 i. Already we have local Iraqi manpower for skilled and unskilled job and in future it is expected to
rise considerably.
 ii. Our NDT services are skilled job and require internationally recognized training and qualification.

 iii. We plan to find out academically well qualified manpower and train them to international level
either in Iraq by inviting expat trainers or taking the manpower to Istanbul, Turkey where we
have full-fledged training centre.
 iv. We plan to engage local manpower 25% in the 1st year, 40% in the 2nd year and 50% in the 3rd
year in the area of technical, HSE both job specific and general, site co-ordination,
documentation etc.
 v. Actively participating in local social welfare
 vi. Our vision is to make sure of ENKON contribution in rebuilding Iraq and upgrading local
intelligence and skills.
ENKON STRATEGY ON LOCAL CONTENT

 Technology transfer plans.


 ENKON is performing only Non Destructive testing services and PWHT
services. Within this scope, technologies used are Iridium192 Isotope, X-
ray machine the latest in technical and safety equipment and ultrasonic
equipment. During the passage from subcontract to Joint venture
agreement, we will transfer all these equipment and know how to our
subcontractor. In long term, we will maintain their equipment and function
as their consultant
ENKON STRATEGY ON LOCAL CONTENT

 Commitment to assist Iraqi National Contractors in International Standards


and their accreditation.
 First item will be safety. Especially when working with radioactive it is very
important to protect workers and public from radiation. Therefore it is
necessary to make more attention to safety. We will teach our sub-
contractor to international level safety aspects for radiation.
 Secondly we develop their quality management system according to the
International Standard and upgrade them to get accreditation to ISO
systems. For this reason we will integrate level III certified inspector to the
system.
ENKON STRATEGY ON LOCAL CONTENT

 Plans to invest in and develop local businesses that may support


CONTRACTORS operations under this Project.

 NDT is a services business; there is no major scope to develop local


business. ENKON will make effort to procure all possible NDT consumables
from local suppliers. As the consumables have to meet international
quality standards, we select some capable suppliers from locals and
provide them know how and the process to procure from international
suppliers.
ENKON STRATEGY ON LOCAL CONTENT

 Workforce Nationalisation and Training Plan


 The subcontracting agency shall have operators of only locals. We engage
them with our internationally qualified operators to educate them on site. We
provide them professional training with our company L-III experts in all
disciplines they involve either in Iraq or taking the manpower to Istanbul,
Turkey. When the operators are qualified we allocate a site with our supervisor’s
assistance. We will assist them to procure necessary equipment and
instruments, its operation and calibration activities, maintenance know how,
record keeping, radiation safety activities, license requirements awareness.
 After commencing job, it is required evaluating local subcontractor.
 We help them in making an accredited establishment with necessary contacts
and assistance to comply with ISO 9001, ISO 14001, ISO 17020, OHSAS 18001.
NDT METHODS

CONVENTIONAL
NDT

SURFACE INSPECTION
MATERIAL PROPERTY CHECK
1. VISUAL TESTING VOLUMNAR INSPECTION
1. HARDNESS TESTING
2. MAGNETIC PARTICLE TESTING 1. RADIOGRAPHY TESTING
2. POSITIVE MATERIAL ANALYSIS
3. PENETRANT TESTING 2. ULTRASONIC TESTING
3. SOIL DENSITY TEST
4. EDDY CURRENT TESTING
NDT METHODS

ADVANCED NDT

UT
1. TOFD
OTHER METHODS
RT 2. PAUT
1. MAGNETIC FLUX LEAKAGE
1. DIGITAL RADIOGRAPHY 3. CORROSION MAPPING
2. PULSED EDDY CURRENT
4. HYDROFORM
5. LRUT
PLANT INTEGRITY INSPECTION

 1. PRESSURE VESSEL INSPECTION- API 510


 2. STORAGE TANK INSPECTION- API 653
 3. PIPING INSPECTION- API 570
 4. WELDING INSPECTION – CSWIP 3.1/AWS-CWI
 5. COATING INSPECTION- BGAS – 2/NACE-CPI-2
RADIOGRAPHIC TESTING

 Industrial radiography is used for a variety of applications but is commonly


performed using two different sources of radiation, X-Ray and Gamma ray
sources.
 X-Ray capabilities run the gamut from 4 MEV units utilized to radiograph
extremely large and thick castings and forgings, to portable X-Ray
cameras used for field weld applications and thin wall material inspection.
 Gamma sources vary from very low level fluoroscopic units to perform real
time corrosion under insulation surveys, to Iridium (Ir192) and Selenium (Se
75) sources used for a variety of weld inspections, to Cobalt (Co 60)
inspections for thick component testing.
GAMMA RAY EQUIPMENT

SENTINEL 880 PROJECTOR


GAMMA EXPOSURE SET UP
X-RAY EQUIPMENT
RT BY CRAWLER

 The X-Ray Crawler is similar to conventional radiography however an x-ray


source tube on a crawler device is run inside the pipeline to each weld
which can be controlled by outside remote sensor. The technique is quick
and can inspect on average 150 welds per day. The biggest advantage of
x-ray crawlers is REDUCTION IN EXPOSURE TIME AND NUMBER OF
EXPOSURES.
X-RAY CRAWLER EQUIPMENT
SCAR PROJECTOR

 The Model 959M portable gamma radiographic exposure device is specifically


designed as a Small Controlled Area Radiography (SCAR) system. The SCAR
projector is used primarily for the radiography of standard or difficult joint
geometries without disruption and the need for large barrier areas.
 The SCAR system is comprised of a Model 959M projector, a pneumatic control
unit and a series of clamps to fit a variety of pipe sizes.
 The system may be used with a maximum of 15 curies of Iridium-192 or 81
curies of Selenium-75. Lower activity sources with smaller focals are available.
 Allows for 24 Hour radiography
 Highly directional beam
 Ideal for offshore barge RT where area clearance is critical.
SCAR PROJECTOR

 SENTINELTM Model 1075 SCARPro source projector is used for industrial non-
destructive testing applications of gamma radiography with Selenium-
75. SCARPro can be used as a category I or II exposure device.
 When used in SCAR mode (category I), the SCARPro allows radiography to be
performed in congested work areas with a minimal distance to the controlled
areas.
 When used as a traditional projector (category II), standard SENTINELTM source
guide tubes and collimators allow the Selenium-75 source to be used for axial,
radial and panoramic exposures.
 Model 1075 SCARPro is a dual mode radiographic exposure device for Small
Controlled Area Radiography and traditional projection radiography.
 An interchangeable collimator with a 90o incremental adjustment enables safe
radiography in areas congested with workers.
SCAR PROJECTOR EQUIPMENT
RADIOGRAPH
ULTRASONIC TESTING

 Waves are introduced into a material and travel in a straight line and at a
constant speed until they encounter a discontinuity. The interface causes
some of the wave energy to be reflected and the rest of it to be
transmitted. The amount of reflected vs. transmitted energy is detected and
provides information on the size of the reflector, & therefore the
discontinuity encountered.
MANUAL UT EQUIPMENT
MANUAL UT
ECHO PATTERN FOR INTERPRETATION
UT THICKNESS MEASUREMENT
PAUT HYDROFORM PROBE SCANNING
AUT PHASED ARRAY

 Phased Array ultrasonic testing (PAUT) is an advanced method of ultrasonic


testing. Phased array ultrasonic method can reveal defects embedded in
the material that cannot be easily resolved with conventional ultrasonic
testing.
 The phased array probe consists an array of number of small ultrasonic
transducers each of which can be pulsed individually.
 Sizing of defects is very accurate by PAUT.
AUT PHASED ARRAY EQUIPMENT
PROBE ARRANGEMENT
PAUT RECORDED REPORT
AUT TIME OF FLIGHT DIFFRACTION (ToFD)

 Time of Flight Diffraction (ToFD) is an advanced method of Ultrasonic


inspection.
 It is a very sensitive defect detection method in welded joints.
 Time of Flight Diffraction (ToFD) ultrasonic test method can perform crack
detection very precisely and allow the owner to run the equipment or
plants until the critical crack depth and length is not reached with a
minimal risk of failure.
AUT TIME OF FLIGHT DIFFRACTION (ToFD) EQUIPMENT
TOFD-PROBE ARRANGEMENT
TOFD RECORDED REPORT
CORROSION MAPPING RMS2

 The RMS2 is a high speed, high accuracy remote access ultrasonic corrosion mapping
system designed to evaluate the condition of assets as storage tanks, pipelines, pressure
vessels and other critical equipment, supporting efficient inspection programme that
support integrity management processes to ensure effective and safe operation.
 The RMS2 ultrasonic scanner can give 100% coverage in a band up to 1000 mm wide,
significantly increasing Probability of Detection (POD) of defects and corrosion, enabling
engineers to determine the optimum repair strategy and improve remaining life
assessment (RLA) & risk based inspection (RBI) maintenance programs.

The RMS2 is extremely flexible with a range of scanning heads to suit different inspection
requirements.

RMS2 SCANNER
CORROSION MAPPING SCANNING
CORROSION MAPPING SCANNING
VESSEL ROLLED OUT VIEW/
SCAN LOCATION DIAGRAM
COMPOSITE C SCAN IMAGE DIAGRAM
LRUT-LONG RANGE UT
GWT-GUIDED WAVE UT
 LRUT is traditionally used to detect corrosion, erosion and other defects in
pipework. An array of transducers is clamped around the pipe and
ultrasound is transmitted simultaneously along the pipe in both directions.
 The technique’s principal advantage is that it provides 100% initial
screening coverage, and only requires local access to the pipe surface
where the transducer array is to be attached. The technique has the
ability to inspect inaccessible areas such as clamps and cased or buried
pipes. It works without the need to remove insulation or coating.

CONVENTIONAL UT & LRUT
LRUT PROBE/BELL HOLE TESTING
LRUT EQUIPMENT SET UP
LRUT PROBE
LRUT – SCAN SIGNAL ON BOTH SIDES OF
PROBE
MAGNETIC PARTICLE TESTING

 Used for finding surface/near surface defects in ferromagnetic material,


Magnetic Particle testing is a versatile inspection method used for field and
shop applications. Magnetic particle testing works by magnetizing a
ferromagnetic specimen using a magnet or special magnetizing
equipment. If the specimen has discontinuity, the magnetic field flowing
through the specimen is interrupted and leakage field occurs. Finely milled
iron particles coated with a dye pigment are applied to the specimen.
These are attracted to leakage fields and cluster to form an indication
directly over the discontinuity.
MAGNETIC PARTICLE TESTING EQUIPMENT
MGNETIC PARTICLE INDICATIONS
LIQUID PENETRANT TESTING

 Penetrant testing – Based on the properties of capillary action, or the


phenomenon of a liquid rising or climbing when confined to a small
opening due to surface wetting properties of the liquid, Penetrant testing is
used for finding surface breaking discontinuities on relatively smooth,
nonporous surfaces
LIQUID PENETRANT TESTING
PENETRANT INDICATION
POSITIVE MATERIAL IDENTIFICATION

 NITON’s XRF alloy analyzers are portable hand-held devices that can
perform a chemical composition analysis on the material at any time in
merely seconds. XRF works by exposing the material to a flux of x-rays. The
atoms then absorb the energy and become temporarily excited and they
fluoresce, or emit x-ray. The x-rays emitted by the sample’s atoms possess
clearly defined energies that are unique to the elements present in the
sample. By measuring the intensity and energy, the XRF instrument can
provide qualitative and quantitative analysis. In other words, it can identify
the elements, measure the concentration of each and display them on the
unit.
POSITIVE MATERIAL IDENTIFICATION EQUIPMENT
PMI REPORT
EDDY CURRENT TESTING (ECT)

 Eddy Current testing uses the principals of electromagnetism as the basis


for conducting inspections. When alternating current is applied to a
conductor a magnetic field develops in and around the conductor. When
a second conductor is introduced into the magnetic field an induced
current flow is created. Eddy currents are a type of induced current.
 1. Crack detection-A primary use of eddy current inspection as cracks
cause a disruption in the circular flow patterns of the eddy currents and
weaken their strength.
 2. Conductivity measurements-Because of the sensitivity to changes in
a material's conductive properties and magnetic permeability, Eddy
Current is an excellent tool for material Identification and Material Sorting.
EDDY CURRENT TESTING
MAGNETIC FLUX LEAKAGE (MFL)

 Strong magnet induces a magnetic field in the material. At areas where there is
corrosion or missing metal, a leakage field will arise. The output from the
detector can be electronically digitalized for automated inspection systems.
 Leakage from storage tanks containing gas, oil or chemicals, or the influence
of the weather on the external surfaces of storage soils and tanks pose a very
hazardous situation. Material can also be affected by internal temperature
variations. Therefore the condition of tanks, and in particular the tank bottom, is
of outstanding importance.
 Magnetic Flux Leakage (MFL) is a method of Non-Destructive Testing, which is
used to detect corrosion and pitting in steel structures, most commonly
pipelines and storage tanks.
 MFL is a detection technique, which detects volumetrically changes. It is a very
suitable tool for detecting corroded spots in the plates.
MAGNETIC FLUX LEAKAGE (MFL) EQUIPMENT
MFL REPORT – COMBINED IMAGE
VISUAL INSPECTION

 A visual inspection or visual examination of objects, parts or components is


the oldest and reliable non-destructive testing method.
 The test method is applied to almost every product as a quality assurance
tool.
 The most detrimental unacceptable discontinuities in the objects or items
are the surface opening discontinuities.
WELD VISUAL INSPECTION
API VISUAL INSPECTION
API-VISUAL INSPECTION
API-PITTING MEASUREMENT
HARDNESS TESTING

 Enkon specialise in hardness testing of various materials from stainless to


copper-aluminium alloys (bronze) using a range of different equipment:
Equotip, Mic 10, poldi and Vickers Diamond, with the results given in
different hardness conversions such as LD, HV, HB, HRB, HRC and HS.
HARDNESS TESTING EQUIPMENT
HARDNESS REPORT
POST-WELD HEAT TREATMENT (PWHT)

 Post-weld heat treatment is most generally used for stress relief. The
purpose of stress relieving is to remove any internal or residual stresses that
may be present from the welding operation. Stress relief after welding may
be necessary in order to reduce the risk of brittle fracture, to avoid
subsequent distortion on machining, or to eradicate the risk of stress
corrosion.
POST-WELD HEAT TREATMENT (PWHT)
PWHT
TROXLER EQUIPMENT
TROXLER-SOIL TEST REPORT
GCMC SERVICES

 Radiograph Interpretation
 Status updating on line.
 Management of NDT activities of construction contractors and NDT contractors.
 Preparation of daily and weekly reports of NDT status.
 Updating ROO with required suggestions if weld repair rate exceeds 5%.
 Wetting contractor NDT procedures.
 Witnessing Welder qualification test and welding procedure qualification
records test.
 Certifying completion Dossiers.
EXAMPLE OF NDT DAILY STATUS
LIST OF ROO APPROVED PROCEDURES
 Company procedure for personnel qualification and certification for NDT
 Radiography Testing, RTFI
 Radiation Safety Assurance Instructions.
 Ultrasonic Testing – Manual, PAUT, TOFD, CORROSION MAPPING, HYDROFORM, LRUT
 Magnetic Particle Testing.
 MAGNETIC FLUX LEAKAGE TEST FOR TANK BOTTOM PLATES
 Penetrant Testing.
 Hardness Testing.
 Positive Material Testing.
 Post Weld Heat Treatment.
 Soil Testing
 VISUAL TESTING
 WELDING INSPECTION
 API PROCEDURES FOR PRESSURE VESSEL, STORAGE TANK AND PIPING INSPECTION
 VACUUM BOX LEAKAGE TEST
ENKON CODE BANK

 ASME SEC.1, II, V, VIII, IX


 ASME B 31.1,31.3, 31.4, 31.8 AND MANY OTHERS
 EN-ISO – COMPLETE RANGE
 AWS – D1.1 AND MANY OTHERS
 API – 1104, 650, 653, 510, 570 AND MANY OTHERS
 ASNT – SNT-TC-1A, CP189, ALL NDT METHOD HAND BOOKS
 COMPLETE RANGE OF STUDY MATERIAL
 ENKON UPDATES CODE BANK EVERY YEAR.
 MEMBER OF ASNT, ASME AND OTHER CODE SELLERS.
ACCREDITATIONS ISO 9001:2008
ISO 14001:2004
OHSAS 18001:2007
ISO 17020:2012
RT SAFETY – ISOTOPE STORAGE FACILITY
ISOTOPE STORAGE LOCATION
RT SAFETY-GOVERNING FACTORS

 ENKON storage facility is approved by IRSRA Iraq and authorised to carry out
Radiography by Isotopes, Export and Import of isotopes from and to Iraq, transporting and
handling of isotopes in Iraq.
 ROO has approved our Radiation safety procedure and conducted frequent site audits
and document audits and found no any major discrepancies.
 ENKON is very much safety conscious to it’s personnel as well as public in the working
environment.
 The working area is well barricaded as per national and international norms.
 Ensures all radiation safety instruments are properly used, monitor its performance,
calibrated in time.
 All ENKON personnel are informed to stop the ENKON’s work on site if the ongoing work is
considered to be unsafe.
 Equipment are service maintained in a schedule.

You might also like