Fire Resistive Properties of Gypsum

G
ypsum—hydrous calcium sulfate—is an “The gypsum in the core of the board actually emits
abundant, naturally occurring mineral quarried steam when exposed to fire and retards transfer through
for a variety of uses, the most common, of the panel. This slowdown provides extra time to evacuate
course, being gypsum board. Roughly 90 a room or building.” It can, in a sense, be compared to
percent of finished interior surfaces are covered today with what happens when a blowtorch is turned on a block of
gypsum products. ice. Although the ice is being melted, one can hold a hand
on the opposite side without being burned. Even though
Two molecules of water are chemically the ice gets very thin it effectively
bound to each calcium sulfate group blocks the transfer of the intense heat
during the formation of the gypsum and one’s hand would not be burned
crystal. As a result, gypsum is about 21 until the ice is melted.
percent chemically combined water. Calcium Sulfate Dihydrate
One of the many unique properties of When gypsum-protected wood or steel
gypsum is its ability to give up these structural members are exposed to a
water molecules as steam when heated, in a process known fire, the chemically combined water (being released
as calcination, making gypsum board ideally fire-resistant. as steam) acts as a thermal barrier until this slow
process, known as calcination, is completed.
The most important characteristic of drywall, say fire The temperature directly behind the plane of
officials, is that it will not burn. “Statistics show that in calcination is only slightly higher than that of
recent years, fewer people have died in fires in the U.S.,” boiling water (212°F), which is significantly
says the Gypsum Association. “Naturally, there is no single lower than the temperature at which steel
reason for the decline. But the diminished number has a begins losing strength or wood ignites.
high correlation with the increased use of gypsum products Once calcination is complete, the in-place
and other fire-resistant building materials,” they say. calcined gypsum continues to act as a
barrier protecting the underlying structural
members from direct exposure to flames.

Fire Safety in Building Design

F
ire safety today is one of the most critical Designing a structure to ensure minimal
issues in designing and constructing any risk or to meet a prescribed level of
modern structure. Of course, the basic goal safety from fire is more complex than just
and objective is to reduce the probability that the simple consideration of what building
a person in or adjacent to a building will be exposed to materials will be used.
an unacceptable fire hazard as a result of the design and
construction of the building. Although the potential for Our ability to design ever-more fire resistant
being killed or injured in a fire cannot be completely structures emphasizes the vital importance
eliminated, fire safety in a building can be achieved architects and engineers face in selecting the
through proven building design features intended to proper building materials and fire-resistant
minimise the risk of harm to people from fire to the assemblies to protect against loss of life, and limit
greatest extent possible. fire impact on the community.

Page #34
Fire & Sound Rated
Systems
a division of PABCO® building products, LLC
FIRE & SOUND
RATED SYSTEMS
"Quality to the Core"
R

Fire Resistance Assemblies: PABCO® Gypsum is proud to list hundreds of UL fire tested assemblies shown on the opposite page. All of
these assemblies are UL approved, and allow the use of one or more PABCO® products available from our
extensive range of gypsum board product line. Each assembly is tested within a controlled laboratory setting,
and receives individual engineering evaluations. The following design selection pages present a relative small
fraction of the available approved assemblies. Individual designs are prefaced with a brief description and
summary. The complete design, and updated information, may be found in the Underwriter Laboratories
(UL) Fire Resistant Directory (www.ul.com), the Gypsum Association’s “Fire Resistance Design Manual”
(GA-600) (www.gyspum.org), or by contacting PABCO® Gypsum Technical Services.

PABCO® Gypsum type X products bear the UL Classification Mark and are covered by UL’s classification
and Follow-Up Service.

The facing page is a cross reference of appropriate PABCO® Gypsum panel products to use for different
UL fire-resistive Designs.

Although the systems are arranged herein (as well as the GA-600) in general groupings (i.e. walls and
interior partitions, floor-ceilings, roof-ceilings, etc.), the listing of a system in a specific category is not
intended to limit its use to that category. However, this shall not be interpreted to imply that vertical
systems, such as walls and partitions, are permitted to arbitrarily be used in a horizontal orientation.1

1. Gypsum Association GA-600-2009, pg 7

Notes pertaining to design • Spacing of stud, joist, or trusses are maximum for fire rating
listings: • Size of the studs are minimum
• Metal studs and runners are nominal 25 gage unless otherwise specified
• Metal studs and runners greater than specified as tested shall be permitted, however STC ratings may
be negatively effected

Fire Resistance Ratings: Underwriters Laboratories (UL), ASTM, and numerous building codes use fire-resistant ratings as
a measure of fire-containment for varying types of building construction assemblies. In respect to
buildings, the fire resistance rating classifies the ability of an assembly to confine and isolate fire within
a zone comprised of fire resistance rated walls, ceiling and floor assemblies. These fire-resistance rated
assemblies are tested, certified and listed in the directories of accredited Fire Testing Laboratories. The
most up-to-date information is available at the fire testing laboratory website or from PABCO® Gypsum
Technical Services.

For more information: • Refer to Underwriters Laboratories (UL) Fire Resistance Directory at www.ul.com.
• Refer to the Gypsum Association Fire Resistance Design Manual, publication GA-600.
• Contact PABCO® Gypsum Technical Services, or your qualified PABCO® Gypsum Field
Representative (please reference the back cover of this publication for contact information).

Abbreviations: Agency Fire Agency Sound Sound Ratings


ASTM American Society for Testing and BBN Bolt, Beranek and Newman CAC Ceiling attenuation class per
Materials G&H Geiger & Hamme ASTM procedures
CEG Consulting Engineers Group CK Cedar Knolls Acoustical Labs IIC Impact insulation class per ASTM
GA Gypsum Association (Fire Resistance KAL Kodaras Acoustical Laboratories procedures
Design Manual GA-600) RAL Riverbank Acoustical Laboratories STC Sound transmission class per
OSU Ohio State University SA Shiner & Assoc. ASTM procedures
U of C University of California USG USG Corporation
UL Underwriters Laboratories Inc NGCTS National Gypsum Corp Testing Service
WHI Warnock Hersey International
FM Factory Mutual
ITS Intertek Testing Services NA Inc
SwRI Southwest Research Institute
WFCi Western Fire Center, Inc.

Page #36 SJ B4--22-09/ Fire Rated Systems/ PABCO® Gypsum


UL FIRE RATED SYSTEM
ASSEMBLY CROSS REFERENCE
a division of PABCO® building products, LLC

"Quality to the Core"


R

by PRODUCT
PABCO® products currently manufactured below are appropriate to use in the
following UL Fire Rated Assemblies, as shown in UL CKNX.R7094. March 2009
PABCO® Product UL Core width UL Fire Rated System Assembly listing
• 5/8" FLAME CURB® type X PG-11* 46" 5/8 in. thick, 46 to 54 in. wide, Type PG-11 for use in Design Nos.: G501, G503,
to G505, G507, G508, G531, L501, L508, L532, L556, L591, N501, N502, N505,
• 5/8" Soffit Board type X 54" P508, P510, P511, P517, P540, P541, U017, U026, U207, U208, U301, U302,
U305, U309, U321, U326, U329, U330, U337, U338, U339, U341, U342, U344,
U351, U354, U355, U356, U357, U358, U360, U364, U368, U369, U374, U379,
* (PG-11
U411, U418, U420, U421, U425, U434, U436, U439, U442, U445, U449, U450,
replaces U460, U465, U466, U467, U469, U473, U485, U487, U494, U502, U504, U505,
PG-9) U506, U510, U512, U603, U606, U609, U615, U617, U622, U625, U637, U640,
V417, V419, V421, V431, X508, X510, X516, X517, X525, X526, X527, X528.

• 5/8" FLAME CURB® Type C 48" 5/8 in. thick, 4 ft wide, Type C for use in Design Nos.: D301, D501, D502, G501,
Super C G503, G505, G512, G515, G521, G523, G525, G526, G527, G528, G529, G530,
G531, G538, J501, J502, J503, J504, L501, L505, L508, L511, L512, L513, L514,
• 5/8" Soffit Board Super C L516, L520, L523, L525, L526, L527, L528, L529, L530, L538, L539, L540, L541,
L548, L588, L591, L592, N501, N502, N505, P501, P502, P503, P504, P505,
P506, P507, P508, P509, P510, P513, P514, P519, P549, U023, U301, U302,
U305, U309, U311, U329, U333, U334, U340, U342, U354, U355, U379, U411,
U428, U429, U442, U445, U451, U457, U465, U466, U467, U469, U473, U485,
U501, U502, U504, U505, U506, U510, U512, U602, U603, U605, U617, U618,
U627, U634, U635, U639, U640, U642, U643, U644, U645, V414, V417, V419,
X501, X502, X504, X508, X509, X516, X517, X525, X526, X527, X528.

1/2 in. thick, 4 ft wide, Type PG-C for use in Design Nos.: G502, G504, G515,
• 1/2" FLAME CURB® Super C PG-C 48" G523, G524, G526, G527, G528, G529, G530, G531, G533, G534, L502, L503,
L504, L507, L510, L512, L514, L524, L525, L530, L542, P237, P510, P512, U312,
U317, U320, U406, U410, U412, U426, U428, U429, U435, U436, U438, U440,
U441, U443, U444, U448, U451, U452, U453, U454, U455, U467, U474, U478,
U601, U603, U608, U611, U613, U614, U619, U620, U910, U912, U914, V418,
X507, X513, X514, X515, X518, X520, X521, X522, X523, X524, X530, X531.

• 1/2" FLAME CURB® type XXX 48" 1/2 in. thick, 4 ft wide, Type PG-3 for use in Design Nos.:
G502, G504, G523, G524, G526, G528, L502, L503, L504, L507, L580,
• 1/2" Soffit type XXX P237, U312, U317, U410, U502, U603, U608, U611, U613, U614, U619,
PG-3 U620, X513, X520.

46" 1/2 in. thick, 46 to 54 in. wide, Type PG-3 for use in Design Nos.:
to
54" G504, L503, L504, U317, U502, U611, U613, U614.

• 5/8" WATER CURB® type X


5/8 in. thick, 4 ft wide, Type PG-3W , PG-3WS , PG-5W or PG-5WS for use in
• 5/8" MOLD CURB® Plus type X 48"
Design Nos.: U301, U305, U342, U354, U355, U379.
• 5/8" Gypsum Sheathing type X PG-5W
• 5/8" MOLD CURB® Plus PG-5WS
Sheathing type X 46" 5/8 in. thick, 46 to 54 in. wide, Type PG-5W or PG-5WS for use in
to
• ABUSE CURB™ 54" Design Nos.: U301, U305, U354, U379.

• 1" PABCORE® SHAFTLINER, PG-10 24" 1 in. thick, 24 in. wide Type PG-10 for use in
• 1" PABCORE® MOLD CURB® Plus Design Nos. U428, U429.
to
SHAFTLINER the ®
Updates and current information: Information referred to in this document may change without notice. Visit www.ul.com for current information, or call PABCO® Technical Services @ 866-282-9298

Page #37 SJ- 4-18-11 PABCO® Gypsum


GUIDE to ASSEMBLIES - Fire & Sound
Fire STC GA File Number Page
GUIDE OVERVIEW: Rating

This GUIDE to ASSEMBLIES presents a small selection WALLS & INTERIOR PARTITIONS
of assemblies in which PABCO® Gypsum products have Steel Framed
1 hr 55-59 WP 1015 40
been approved for use. There are numerous other approved
1 hr 50-54 WP 1021 40
assemblies available within each of the following sections.
1 hr 45-49 WP 1070 40
1 hr 40-44 WP 1206; (UL U425) 40
Listed within each section (for example: Walls & Interior
1 hr 35-39 WP 1350; 40
Partitions, Steel Framed), assemblies are arranged
2 hr 55-59 WP 1521 41
sequentially in increasing fire ratings. Within each
2 hr 55-59 WP 1522 41
grouping of fire ratings (for example, one hour), the
2 hr 50-54 WP 1545 41
assemblies’ Sound Ratings (STC) are listed in decreasing
2 hr 50-54 WP 1548 41
order of STC.
2 hr 45-49 WP 1616; (UL411) 42
2 hr 45-49 WP 1635; (UL U425) 42
Each assembly listing provides a reference to the Gypsum
2 hr 40-44 WP 1716; (UL U425) 42
Association File Number and/or UL Design Number
2 hr 50* (UL U421) *STC Estimated 42
for additional information, as well as the page number
3 hr 50-54 WP 2022; (UL U435) 43
directing you to the test description listed on the following
4 hr 55-59 WP 2961; (UL U435) 43
pages of this guide.

As this is a “selection” of assemblies for which PABCO® WALLS & INTERIOR PARTITIONS, CHASE WALLS
products have been approved for use, it is important to note Wood Framed
that there are numerous other approved assembles. These 45 m (UL U317) 44
additional assemblies are described in detail in the Gypsum 1 hr 50-54 WP 3241; (UL U311) 44
Association Fire Resistant Design Manual GA-600 (current 1 hr 50-54 WP 3242; (UL U309) 44
is the 19th edition), as well as within UL’s Certification 1 hr 50-54 WP 3243; (UL U309) 44
Directory CKNX.R7094 (see UL® Fire Rated Systems 1 hr 45-49 WP 3370; (UL U305) 45
Product Selection Guide, previous page). 1 hr 45-49 WP 5512; (UL U305) 45
1 hr 40-44 WP 3880; (UL U305) 45
1 hr 40-44 WP 5515; (UL U305) 45
1 hr 35-39 WP 3510; (UL U309; UL U314) 46
1 hr 35-39 WP 3514 46
1 hr 35-39 WP 3520 46
1 hr 30-34 WP 3605 46
2 hr 55-59 WP 3812 46
2 hr 55-59 WP 3810 47
2 hr 55-59 WP 3820; WP 5520 47
2 hr 50-54 WP 3910, WP 5530; (UL R4024) 47
2 hr 40-44 WP 4135, WP 4136 47

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com
Page #38 SJ 6-14-11/Guide to Fire Rated Systems/ PABCO® Gypsum
GUIDE to ASSEMBLIES - Fire & Sound
Fire STC GA File Number Page Fire STC GA File Number Page
Rating Rating

SHAFT WALL SYSTEMS ROOF CEILING - Wood Framed


1 hr 45-49 WP 6800 48 1 hr RC 2608; (UL P549) 58
2 hr 50-54 WP 7051; (UL U428) 48 1 hr RC 2602 58
2 hr 50-54 WP 7052; (UL U429) 48 2 hr RC 2750; (UL L556) 58
2 hr 45-49 WP 7082 49 2 hr RC 2751; (UL L556) 59
2 hr 45-49 WP 7083 49

AREA SEPARATION WALL SYSTEMS COLUMNS


2 hr 60-64 ASW 0985 50 Light Tubular Columns:
2 hr 50-54 ASW 1100 50 1 hr CM 1452; (UL X528) 60
2 hr 50-54 ASW 1105 50 1 hr CM 1851, (UL X528) 60
1.5 hr CM 2455; (UL X531) 60
FLOOR CEILING - Steel Framed 2 hr CM 2455; (UL X528) 60

1 hr 50-54 FC 4340 51 Column 10WF-49


1 hr FC 4529, (UL L524) 51 1 hr CM 1001; (UL X528) 60
1.5 hr (UL L527) 51 2 hr CM 2017; (UL X528) 61
2 hr FC 4750; (UL L556) 51 3 hr CM 3120; (UL X509, X510) 61
2 hr 50-54 FC 2030; (UL G514) 52 4 hr (UL X501) 61
2 hr 50-54 FC 3012; (UL G512) 52 Column 14WF-228
2 hr CM 2110; (UL X520) 61
FLOOR CEILING - Wood Framed 3 hr CM 3130; (UL X513) 61
1 hr 55-59 FC 5105; (UL L502) 53
1 hr 55-59 FC 5107; (UL L514) 53
1 hr 50-54 FC 5111 53 BEAMS & GIRDERS
1 hr 50-54 FC 5116; (UL L516) 53 1 hr BM 1137; (UL L524) 62
1 hr 50-54 FC 5120 54 2 hr BM 2120; (UL N501) 62
1 hr 45-49 FC 5241 54
1 hr 45-49 FC 5250; (UL L502) 54
1 hr 35-39 FC 5415; (UL L513) 54
1 hr 35-39 FC 5406 55
1 hr 35-39 FC 5407 55
1 hr 35-39 FC 5410; (UL L512, L522, L503, L519) 55
1 hr 35-39 FC 5420; (UL L501) 55
1 hr FC 5520; (UL L592) 56
1 hr FC 5515; (UL L528) 56
2 hr FC 5751; (UL L556) 56
2 hr FC 5710; (UL L511) 57
2 hr FC 5724; (UL L505) 57
2 hr FC 5750; (UL L556) 57

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com
Page #39 SJ 6-14-11/Guide to Fire Rated Systems/ PABCO® Gypsum
FIRE RATED SYSTEMS a division of PABCO® building products, LLC

WALLS & INTERIOR PARTITIONS "Quality to the Core"


R

Steel Framed
Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

GA Fire & Sound


FIRE STC
Rating Rating File No
Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
See WP 1051
Base layer PABCO® 1/4" Regular gypsum wallboard applied
(FM WP 152-1)
NA 4-1/4˝ parallel to each side of 2-1/2" steel studs 24" o.c.
Face layer 5/8" FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8" PABCO®
1hr WP 1015 type X gypsum sheathing applied parallel to each side.
Sound Test:
Joints staggered 24" each layer and side. Sound tested with CK 684-14
1-1/2" mineral fiber insulation, 3.0 pcf, friction fit in stud space.
55-59 4-1/4˝
NON-LOAD BEARING

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


FM WP 66
One layer 1/2" FLAME CURB® type XXX gypsum wallboard

applied parallel to ONE SIDE of 2-1/2" steel studs 24" o.c.
NA
OPPOSITE SIDE: Base layer 1/2" FLAME CURB® type XXX
gypsum wallboard applied parallel to studs.
Face layer 1/2" FLAME CURB® type XXX gypsum wallboard
1 hr WP 1021 applied parallel to studs.
Sound Test:
Joints staggered 24" each layer and side. RAL TL88-55
Sound tested with 3-1/2" glass fiber insulation friction fit in
50-54 4˝ stud space and all layers screw attached without adhesive.
NON-LOAD BEARING

PABCO® GYPSUM WALLBOARD, STEEL STUDS, Fire Test:


MINERAL FIBER INSULATION FM WP 51-1,
OSU T-3362,
One layer 1/2" FLAME CURB® type XXX gypsum wallboard
applied parallel to each side of 2-1/2" steel studs 24" o.c. 2"
Sound Test:
1 hr 45-49 WP 1070 3-1/2˝ mineral fiber insulation, 2.5 pcf, friction fit in stud space.
RAL TL69-42
Also fire tested with 1-1/2" mineral fiber insulation, 3.0 pcf,
stapled to board in stud space.
Joints staggered 24" on opposite sides
NON-LOAD BEARING
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL NC 505-2,
One layer 5/8" FLAME CURB® type X gypsum wallboard,
UL DESIGN U425
5/8" WATER CURB® type X backing board, or 5/8" PABCO®
1 hr 40-44 WP 1206 4-3/4˝ type X gypsum sheathing applied parallel to each side of Sound test:
3-1/2" 20 gage steel studs 24" o.c. see WP 1350
NGC 2385
Joints staggered 24" on opposite sides.
Bracing requirement. LOAD BEARING
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
FM WP-45;
One layer 5/8" FLAME CURB® type X gypsum wall board,
OSU T-1770;
5/8" WATER CURB®, or 5/8" PABCO® type X gypsum sheathing
ULC 79T484,
applied parallel or at right angles to each side of 3-5/8" steel
79T500, 79T497,
studs 24" o.c.
ULC Design
1 hr 35-39 WP 1350 4-7/8˝
Joints staggered 24" on opposite sides. W415
NON-LOAD BEARING
Sound Test:
NGC 2005004
RAL TL06-114

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #40 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
WALLS & INTERIOR PARTITIONS
Steel Framed (continued)
Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STCGA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
See WP 1545
Base layer 1/2" FLAME CURB® type XXX gypsum wallboard
(UC;
NA 5-5/8˝
applied parallel to each side of 3-5/8" steel studs 24" o.c.
ULC 80T499
Face layer 1/2" FLAME CURB® type XXX gypsum wallboard ULC Design
applied parallel to each side. W414)
2 hr WP 1521 Joints staggered 24" each layer and side. Sound tested with
3-1/2" glass fiber friction fit in stud space. Sound Test:
NRCC 815-NV
NON-LOAD BEARING
55-59 5-5/8˝

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


See WP 1548
Base layer 5/8" FLAME CURB® type X gypsum wallboard,
(WHI-495-0236
5/8" WATER CURB® type X backing board, or 5/8" PABCO®
NA 6-1/8˝
type X gypsum sheathing applied parallel or at right angles to
each side of 3-5/8" steel studs 24” o.c.
Face layer 5/8" FLAME CURB® type X gypsum wallboard,
2 hr WP 1522 5/8" WATER CURB® type X backing board, or 5/8" PABCO® type
X gypsum sheathing applied parallel or at right angles to each Sound Test:
side. NRCC 818-NV

55-59 6-1/8˝ Joints staggered 24" each layer and side. Sound tested with
3-1/2" glass fiber friction fit in stud space.
NON-LOAD BEARING

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


UC,
Base layer 1/2" FLAME CURB® type XXX gypsum wallboard
ULC 80T499,
NA 4-1/2˝ applied parallel to each side of 2-1/2" steel studs 24" o.c.
ULC Design
Face layer 1/2" FLAME CURB® type XXX gypsum wallboard W414
applied parallel to each side of 1-5/8" steel studs 24" o.c.
2 hr WP 1545 Joints staggered 24" each layer and side. Sound tested with
1-1/2" mineral fiber insulation friction fit in stud space. Sound Test:
CK 654-40
NON-LOAD BEARING
4-1/2˝
50-54

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


WHI-495-0236
Base Layer 5/8" FLAME CURB® type X gypsum wallboard,
5/8" WATER CURB® type X backing board, or 5/8" PABCO®
NA 5˝ type X gypsum sheathing applied parallel or at right angles to
each side of 2-1/2" steel studs 24" o.c.
Face layer: 5/8" FLAME CURB® type X gypsum wallboard,
5/8" WATER CURB® type X backing board, or 5/8" PABCO®
2 hr WP 1548 type X gypsum sheathing applied parallel or at right angles to
Sound Test:
each side.
WHI-218-1
Joints staggered 24" each layer and side.
50-54 5˝ Sound tested with 2-1/2" glass fiber insulation friction fit in
stud space.
NON-LOAD BEARING

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #41 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
WALLS & INTERIOR PARTITIONS
Steel Framed (continued)
Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STCGA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL R1319-31
Base layer 5/8" FLAME CURB® type X gypsum wallboard,
UL Design U411
5/8" WATER CURB® type X backing board, or 5/8" PABCO® type
X gypsum sheathing applied parallel to each side of 3-5/8"
Sound Test: NGC
steel studs 24" o.c.
2005005,
2 hr 45-49 WP 1616 6-1/8˝ Face layer 5/8" FLAME CURB® type X gypsum wallboard, RAL TL06-115,
5/8" WATER CURB® type X backing board, or 5/8" PABCO®
type X gypsum sheathing applied parallel to each side,
laminating compound combed over entire surface. Metal base
and top retainer channels.
Joints staggered 24" each layer and side.
NON-LOAD BEARING
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
Base layer 1/2" FLAME CURB® type XXX gypsum wallboard UL NC 505-4
applied parallel to each side of 3-1/2" 20 gage steel UL Design U425
studs 24" o.c.
Sound Test:
Second layer 1/2" FLAME CURB® type XXX gypsum wallboard Estimated
applied parallel to each side.
2 hr 45-49 WP 1635 6-1/2˝
Face layer 1/2" FLAME CURB® type XXX gypsum wallboard
applied parallel or at right angles to each side.
Studs attached to each side of floor and ceiling runners.
Joints staggered 24" each layer and side.
Bracing requirement.
LOAD BEARING

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


UL NC 505-6,
Base layer 5/8" FLAME CURB® type X gypsum wallboard,
UL Design U425
5/8" WATER CURB® type X backing board, or 5/8" PABCO® type
X gypsum sheathing applied parallel to each side of 3-1/2”
Sound Test:
20 gage steel studs 24" o.c.
See WP 1615
2 hr 40-44 WP 1716 6˝ Face layer 5/8” FLAME CURB® type X gypsum wallboard, (NGC 2250)
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied parallel to each side.
Joints staggered 24" each layer and side.
Bracing requirement
LIMITED LOAD BEARING

GYPSUM WALLBOARD, STEEL STUDS Fire Test:


UL Design U421
Base layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8”WATER CURB® type X backing board, or 5/8” PABCO®
Sound Test:
type X gypsum sheathing applied vertically or horizontally
*Estimated
on both sides of the studs, with vertical joints centered over
studs and staggered one stud cavity on opposite sides of
studs. Horizontal edge joints (when applied horizontally) and
horizontal butt joints (when applied vertically) on opposite
2 hr NA sides of studs need not be staggered or backed.
Remaining two layers 5/8” FLAME CURB® type X gypsum
wallboard, 5/8”WATER CURB® type X backing board, or 5/8”
PABCO® type X gypsum sheathing applied vertically or
50* horizontally on one side of the wall. Horizontal butt joints
staggered a min of 6 in. on adjacent layers.
When used in widths other than 48 in., gypsum panels to be
installed horizontally.
NON-LOAD BEARING
PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #42 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
WALLS & INTERIOR PARTITIONS
Steel Framed (continued)
Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
WHI-495-0804,
Base layer 1/2" FLAME CURB® Super C gypsum wallboard
UL R7094,
applied parallel to each side of 1-5/8" steel studs 24" o.c.
UL Design U435
NA 4-5/8˝ Second layer: 1/2" FLAME CURB® Super C gypsum wallboard
applied at parallel or at right angles to each side.
Face layer 1/2" FLAME CURB® Super C gypsum wallboard
3 hr WP 2922 applied at right angles to each side.
Joints staggered 24" each layer and side. Sound Test:
WEAL 87-118,
Sound tested with 1-1/2" glass fiber insulation friction fit in
stud space.
50-54 4-5/8˝
NON-LOAD BEARING

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


WHI 495-0819;
Base layer 1/2" FLAME CURB® type XXX gypsum wallboard
UL R7094,
applied parallel to each side of 1-5/8" steel studs 24" o.c.
UL Design U435
NA 5-5/8˝
Second layer: 1/2" FLAME CURB® type XXX gypsum wallboard
applied parallel to each side.
Third layer 1/2" FLAME CURB® type XXX gypsum wallboard
applied parallel or at right angles to each side.
4 hr WP 2961 Face layer 1/2" FLAME CURB® type XXX gypsum wallboard Sound Test:
applied at right angles to each side. WEAL 87-119
Joints staggered 24" each layer and side.
Sound tested with 1-1/2" glass fiber insulation friction fit in
55-59 5-5/8˝ stud space.
NON-LOAD BEARING

to
the ®

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #43 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

WALLS & INTERIOR PARTITIONS, "Quality to the Core"


R

CHASE WALLS - Wood Framed


Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
1/2” PABCO® FLAME CURB® type XXX, or Fire Test:
1/2” PABCO® FLAME CURB® Super C. UL U317
45 4-1/2˝ LOAD BEARING - Nail Attached
NA NA
min

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, Fire Test:


MINERAL FIBER INSULATION, WOOD STUDS Based on
UL R3660-7,
Resilient channels 24” o.c. attached at right angles to ONE SIDE
UL R2717-61,
of 2 x 4 wood studs 16” or 24” o.c. One layer of
UL Design U311
5/8” FLAME CURB® Super C gypsum wallboard applied parallel
to channels. End joints backblocked with resilient channels. 3”
Sound Test:
mineral fiber insulation, 2.0 or 2.3 pcf, in stud space.
5-3/8˝ Estimated
1 hr 50-54 WP 3241 OPPOSITE SIDE: One layer of 5/8” FLAME CURB® Super C
gypsum wallboard applied at right angles to studs.
Vertical joints staggered 48” on opposite sides. Sound tested
with studs 16” o.c. and open face of mineral fiber insulation
blankets toward resilient channel-side of stud space.
LOAD BEARING - Screw attachment

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, Fire Test:


MINERAL OR GLASS FIBER INSULATION, WOOD STUDS Based on UL
R14196,
Resilient channels 16” o.c. attached at right angles to
05NK05371,
ONE SIDE of 2 x 4 wood studs 24” o.c. One layer
UL Design U309
5/8” FLAME CURB® type X gypsum wallboard,
5/8”WATER CURB® type X backing board, or
Sound Test:
5/8” PABCO® type X gypsum sheathing applied at right angles
NRCC TL-93-098,
to channels with vertical joints located midway between
IRC-IR-761,
1 hr 50-54 WP 3242 5-3/8˝ studs. 3” mineral or glass fiber insulation in stud space.
OPPOSITE SIDE: One layer 5/8” FLAME CURB® type X gypsum
wallboard, 5/8”WATER CURB® type X backing board,
or 5/8” PABCO® type X gypsum sheathing applied parallel or at
right angles to studs.
Vertical joints staggered 24” on opposite sides.
LOAD-BEARING - Nail attachment

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, Fire Test:


MINERAL OR GLASS FIBER INSULATION, WOOD STUDS Based on UL
R14196,
Resilient channels 24” o.c. attached at right angles to
05NK05371,
ONE SIDE of 2 x 4 wood studs 24” o.c. One layer
UL Design U309
5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or
Sound Test:
5/8” PABCO® type X gypsum sheathing applied at right angles
NRCC TL-93-103,
to channels with vertical joints located midway between
IRC-IR-761,
1 hr 50-54 WP 3243 5-3/8˝ studs. 3” mineral or glass fiber insulation in stud space.
OPPOSITE SIDE: One layer 5/8” FLAME CURB® type X gypsum
wallboard, 5/8” WATER CURB® type X backing board,
or 5/8” PABCO® type X gypsum sheathing applied parallel or at
right angles to studs.
Vertical joints staggered 24” on opposite sides.
LOAD-BEARING - Nail attachment

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #44 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
WALLS & INTERIOR PARTITIONS, CHASE WALLS
Wood Framed (continued)
Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:
See WP 3605
One layer 5/8” FLAME CURB® type X gypsum wall board,
(UL R1319-4, 6,
5/8” WATER CURB®, or 5/8” PABCO® type X gypsum sheathing
UL R2717-39,
applied parallel or at right angles to each side of double row of
UL R3501-52,
2 x 4 wood studs 16” o.c. on separate plates 1” apart.
UL Design U305;
1 hr 45-49 WP 3370 9-1/2˝ Joints staggered 16” on opposite sides. ULC Design
Horizontal bracing required at mid-height. W301);
UL R 4024
LOAD BEARING - Nail Attachment
Sound Test:
NRCC TL-93-261
IRC-IR-761

PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:


See WP 3605
One layer 5/8” FLAME CURB® type X gypsum wallboard,
(UL R1319-4, -6,
5/8”WATER CURB® type X backing board, or 5/8” PABCO®
UL R2717-39,
type X gypsum sheathing applied parallel or at right angles
UL R3501-52,
to each side of double row of 2 x 4 wood studs 16” o.c. on
UL Design U305;
separate plates 1” apart.
ULC Design
1 hr 45-49 WP 5512 9-1/4˝ Joints staggered 16” on opposite sides. W301);
Horizontal bracing required at mid-height. UL R4024
LOAD BEARING - Nail attachment
Sound:
NRCC TL-93-261
IRC-IR-761

PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:


See WP 3605
One layer 5/8” FLAME CURB® type X gypsum wallboard,
(UL R1319-4,-6,
5/8”WATER CURB® type X backing board, or 5/8” PABCO®
UL R2717-39,
type X gypsum sheathing applied parallel or at right angles to
UL R3501-52,
each side of 2 x 4 wood studs 16” o.c. staggered 8” o.c. on 2 x 6
UL Design U305;
wood plates.
ULC Design
1 hr 40-44 WP 3380 7-3/4˝ Joints staggered 24” on opposite sides. W301);
Horizontal bracing required at mid-height. UL R4024
LOAD BEARING - Nail attachment
Sound Test:
NRCC TL-93-254,
IRC-IR-761

PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:


See WP 3605
One layer 5/8” FLAME CURB® type X gypsum wallboard,
(UL R1319-4,-6,
5/8”WATER CURB® type X backing board, or 5/8” PABCO®
UL R2717-39,
type X gypsum sheathing applied parallel or at right angles to
UL R3501-52,
each side of 2 x 4 wood studs 16” o.c. staggered 8” o.c. on
UL Design U305;
2 x 6 wood plates.
ULC Design
1 hr 40-44 WP 5515 7-3/4˝
Joints staggered 24” on opposite sides. W301);
Horizontal bracing required at mid-height. UL R4024
LOAD BEARING - Nail attachment Sound Test:
NRCC TL-93-254
IRC-IR-761

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #45 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
WALLS & INTERIOR PARTITIONS, CHASE WALLS
Wood Framed (continued)
Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:
UL R3501-47,
One layer 5/8” FLAME CURB® type X gypsum wallboard,
-48,
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
UL Design U309;
type X gypsum sheathing applied parallel or at right angles to
UL R1319-129;
1 hr 35-39 WP 3510 4-7/8˝ each side of 2 x 4 wood studs 24” o.c.
UL Design U314
Joints staggered 24” on opposite sides.
LOAD-BEARING - Nail Attachment. Sound Test:
NGC 2404

PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:


SWRI 01-4511-
One layer of 5/8” FLAME CURB® type X gypsum wallboard,
619[1]
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
type X gypsum sheathing applied parallel or at right angles to
1 hr 35-39 WP 3514 4-7/8˝
each side of 2 x 4 wood studs 16” o.c.
Sound Test:
See WP 3520
Joints staggered 16” on opposite sides.
G&H NG-246FT
LOAD BEARING - Screw Attachment

PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:


FM WP 90
One layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
Sound Test:
type X gypsum sheathing applied parallel to each side of
1 hr 35-39 WP 3520 4-7/8˝
2 x 4 wood studs 24” o.c
G&H NG-246FT
Joints staggered 24” on opposite sides.
LOAD-BEARING - Nail Attachment

PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:


UL R1319-4, -6,
One layer 5/8” FLAME CURB® type X gypsum wallboard,
UL R2717-39,
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
UL R3501-52,
type X gypsum sheathing applied parallel or at right angles to
UL Design U305;
1 hr 30-34 WP 3605 4-7/8˝ each side of 2 x 4 wood studs 16” o.c. Joints of square edge,
ULC Design
bevel edge or predecorated wallboard may be left exposed.
W301
Joints staggered 16” on opposite sides.
LOAD-BEARING - Nail Attachment. Sound Test:
OR 64-8
PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:
See WP 3810
Base layer 1/2” PABCO® FLAME CURB® type XXX, or
(FM WP 297)
1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied
at right angles to 2 x 4 wood studs 24” o.c.
NA 11-1/4˝
Face layer 1/2” PABCO® FLAME CURB® type XXX, or
1/2” PABCO® FLAME CURB® Super C gypsum wallboard applied
at right angles to studs over base layer and to top and bottom
plates. Joints offset 24” from base layer joints.
Inner layer 5/8” FLAME CURB® type X gypsum wallboard, Sound Test:
2 hr WP 3812
Estimated Based
5/8”WATER CURB® type X backing board, or
5/8” PABCO® type X gypsum sheathing applied parallel. on WP 3810
Joints in inner layer need not be taped. (RAL TL73-215;
RAL TL73-224)
11-1/4˝
Second wall duplicate of first wall and separated by 1” space.
55-59 Walls independently loaded.
Sound tested with 3-1/2” glass fiber insulation, 0.75 pcf,
friction fit in stud spaces.

LOAD BEARING - Nail Attachment


PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #46 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
WALLS & INTERIOR PARTITIONS, CHASE WALLS
Wood Framed (continued)
Please refer to the referenced test report for construction details.
Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STCGA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:
FM WP 297
Base layer 1/2” PABCO® FLAME CURB® type XXX, or 1/2”
PABCO® FLAME CURB® Super C gypsum wallboard applied Sound Test:
at right angles to 2 x 4 wood studs 24” o.c. Face layer 1/2” RAL TL73-215,
PABCO® FLAME CURB® type XXX, or 1/2” PABCO® FLAME CURB® RAL TL73-224
Super C applied at right angles. Joints offset 24” from base
layer joints. Inner layer 1/2” PABCO® FLAME CURB® type XXX,
2 hr 55-59 WP 3810 11˝
or 1/2” PABCO® FLAME CURB® Super C gypsum wallboard
applied parallel to studs. Joints in inner layer need not be
taped. Second wall duplicate of first wall and separated by
1” space. Walls independently loaded.
STC 59 with 3-1/2” glass fiber insulation friction fit in stud
spaces both sides; STC 57 without glass fiber insulation.
LOAD BEARING - Nail Attachment
PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:
See WP 4135
Base layer 5/8” FLAME CURB® type X gypsum wallboard,
(FM WP 360);
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
10-3/4˝ UL R4024
NA type X gypsum sheathing applied at right angles to each side
of double row of 2 x 4 wood studs 16” o.c. on separate plates
1” apart.

WP 3820 Face layer 5/8” FLAME CURB® type X gypsum wallboard,


2 hr & 5/8” WATER CURB® type X backing board, or 5/8” PABCO®
Sound Test:
WP 5520 type X gypsum sheathing applied at right angles to each side.
NGC 3056
Joints staggered 16” each layer and side.
Sound tested with 3-1/2” glass fiber insulation stapled to studs
55-59 10-3/4˝ in stud spaces on one side and with nails for base layer
spaced 6” o.c..
Horizontal bracing required at mid-height.
LOAD-BEARING - Nail Attachment
PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:
See WP 4135
Base layer 5/8” FLAME CURB® type X gypsum wallboard,
(FM WP 360);
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type X
UL R4024
gypsum sheathing applied at right angles to each side of 2 x 4
wood studs 16” o.c., staggered 8” o.c. on 2 x 6 wood plates.
Sound Test:
WP 3910 Face layer 5/8” FLAME CURB® type X gypsum wallboard, NGC 2377,
2 hr 50-54 & 8˝
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
WP 5530 type X gypsum sheathing applied at right angles to each side.
Joints staggered 16” each layer and side.
Sound tested with nails for base layer spaced 6” o.c. Horizontal
bracing required at mid-height.
LOAD BEARING - Nail Attachment

PABCO® GYPSUM WALLBOARD, WOOD STUDS Fire Test:


FM WP 360,
WP 4135 Base layer 5/8” FLAME CURB® type X gypsum wall board,
(Nail 5/8” WATER CURB®, or 5/8” PABCO® type X gypsum sheathing
Sound Test:
attached) applied at right angles (parallel or at right angles for WP 4136)
NGC 2363
to each side of 2 x 4 wood studs 24” o.c. (16” o.c for WP 4136).
2 hr 40-44 6-1/8˝
Face layer 5/8” FLAME CURB® type X gypsum board applied at
right angles to each side. Joints staggered 24” (16” o.c. for Fire Test:
SRWI 01-5920-
WP 4136 WP 4136) each layer and side. 614,
(Screw Sound tested with studs 16” o.c. (WP 4135 only). Sound Test:
attached) LOAD BEARING See WP4135
(NGC 2363)

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #47 SJ- 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

SHAFT WALL SYSTEMS "Quality to the Core"


R

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No
Construction Detail Description Test
Numbers
Fire Test:
PABCO® GYPSUM WALLBOARD, STEEL C-T STUDS
WHI-495-1303
One layer 1” x 24” PABCORE® Shaftliner type X, or
1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum
NA 3-1/8˝
panels inserted between 2-1/2” floor and ceiling runners with
T-Section of 2-1/2” steel C-T studs between panels.
OPPOSITE SIDE: One layer of 5/8” PABCO® FLAME CURB®
1 hr WP 6800 Super C gypsum wallboard applied parallel to studs.
Sound test:
Sound tested with horizontal resilient channels 24” o.c. and RAL TL96-28,
2-1/2” glass fiber friction fit in stud space.

45-49 NON LOAD BEARING


3-5/8˝

Fire Test:
PABCO® GYPSUM WALLBOARD, STEEL C-H or C-T STUDS UL R7094,
One layer 1” x 24” PABCORE® Shaftliner type X, or 93NK8151,
1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum UL R3660,
NA 3-1/2˝ panels inserted between 2-1/2” floor and ceiling J runners with 07NK22992
UL Design U428
T-Section of 2-1/2” steel C-H or C-T studs between panels.
OPPOSITE SIDE:
Base layer 1/2” FLAME CURB® Super C gypsum wallboard
2 hr WP 7051 applied at right angles to studs.
Sound Test:
Face layer 1/2” FLAME CURB® Super C gypsum wallboard RAL TL93-181
applied parallel to studs.
Sound tested with 1-7/8” glass fiber insulation in stud space.
50-54 3-1/2˝
NON LOAD BEARING

Fire Test:
PABCO® GYPSUM WALLBOARD, STEEL C-H or C-T STUDS
See WP 7051
One layer 1” x 24” PABCORE® Shaftliner type X, or (UL R7094,
1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum 93NK8151,
panels inserted between 2-1/2” floor and ceiling J runners with UL Design U429)
NA 3-1/2˝
T-Section of 2-1/2” steel C-H or C-T studs between panels.
Face layer 1/2” FLAME CURB® Super C gypsum wallboard
applied parallel to studs with vertical joints midway between
studs and laminated to 1” x 24” PABCORE® Shaftliner type X, or
2 hr WP 7052 1” x 24” PABCORE® MOLD CURB® Plus Shaftliner type X gypsum
panels with 4” wide strips of taping compound at wallboard Sound Test:
perimeter and vertical centerline. See WP 7051
OPPOSITE SIDE: One layer 1/2” FLAME CURB® Super C gypsum (RAL TL93-181)
wallboard applied at rightangles to studs.
50-54 3-1/2˝ Sound tested with 1-7/8” glass fiber in stud space.
NON LOAD BEARING

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #48 SJ 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
SHAFT WALL SYSTEMS (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No
Construction Detail Description Test
Numbers
Fire Test:
PABCO® GYPSUM BOARD, SLOTTED STEEL I STUDS
WHI 495-0528,
One layer 1” x 24” PABCO® PABCORE® SHAFTLINER type X, WHI 495-0566
3-1/2˝ or 1”x 24” PABCORE® MOLD CURB® Plus SHAFTLINER type X
NA
inserted between 2-1/2” floor and ceiling runners with tab-
flange section of 2-1/2” slotted steel I studs between panels.
OPPOSITE SIDE:
2 hr WP 7082 Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum
wallboard applied at right angles to studs. Sound Test:
See WP 7083
Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum (WEAL 84-108)
wallboard applied parallel to studs.
3-1/2˝
45-49
Sound tested with 1” glass fiber insulation friction fit in stud
space.
NON LOAD BEARING

Fire Test:
PABCO® GYPSUM WALLBOARD, SLOTTED STEEL I STUDS
WHI 495-0569,
One layer 1” x 24” PABCO® PABCORE® SHAFTLINER type X, or WHI 495-0570
3-1/2˝ 1”x 24” PABCORE® MOLD CURB® Plus SHAFTLINER
NA
type X gypsum panels inserted between 2-1/2” floor and
ceiling runners with tab-flange section of 2-1/2” slotted steel
I studs between panels.
2 hr WP 7083 One layer 1/2” PABCO® FLAME CURB® type XXX gypsum
wallboard applied parallel to each side. Sound Test:
WEAL 84-108
Sound tested with 1” glass fiber insulation friction fit in stud
space.
45-49 3-1/2˝
NON LOAD BEARING

to
the ®

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #49 SJ 6-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

AREA SEPARATION WALLS "Quality to the Core"


R

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers

PABCO® GYPSUM WALLBOARD, STEEL H STUDS Fire Test:


WFCi #07073
Two layers 1” x 24” PABCORE® SHAFTLINER type X, or 1”x 24”
NA 3-1/2˝ PABCORE® MOLD CURB® Plus SHAFTLINER type X inserted
between 2” floor and ceiling runners with 2” steel H studs
between adjacent pairs of gypsum panels.
NON LOAD BEARING
A 3/4” minimum air space must be maintained between steel
ASFW 0985 Area Separation Fire Wall Sound Test:
components and adjacent framing (indicated by dashed lines
in sketch). As an alternate, the steel components may be RAL TL07-373
ASW
2 Hr 0985
covered with 6” wide battens or full sheets of
1/2” PABCO® FLAME CURB® type XXX gypsum wallboard.
Sound tested with 2 x 4 stud wall faced with
11-3/4˝ 1/2” PABCO® Regular wallboard each side of system and
60-64 3-1/2” glass fiber insulation in stud space.

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


UC
Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum
wallboard applied parallel to each side of 1-5/8” steel studs
NA 3-5/8˝ 24” o.c.
Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum
wallboard applied parallel to each side.
Joints staggered 24” each layer and side.
ASW Sound tested with 1-1/2” mineral fiber insulation in stud space.
2 Hr 1100 NON LOAD BEARING Field Sound Test:
ACI 1131a

50-54 3-5/8˝

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


UC
Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum
wallboard applied parallel to each side of 2-1/2” steel studs
NA 4-1/2˝ 24” o.c.
Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum
wallboard applied parallel to each side.
ASW
2 Hr 1105 Joints staggered 24” each layer and side.
Sound tested with 1-1/2” mineral fiber insulation in stud space.
Sound Test:
NON LOAD BEARING CK 654-40
50-54 4-1/2˝

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #50 SJ 06-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

FLOOR CEILING - STEEL FRAMED "Quality to the Core"


R

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

GA Fire & Sound


FIRE STC
Rating Rating
File Construction Detail Description Test
No. Numbers
PABCO® GYPSUM WALLBOARD, STEEL CHANNEL JOISTS, Fire Test:
PLYWOOD FLOOR NRCC A-4219.A
Base layer 1/2” PABCO®FLAME CURB® type XXX, or 1/2” FLAME Assembly FF-23
NA CURB® Super C gypsum wallboard applied at right angles to
resilient furring channels 16” o.c. Resilient furring channels
applied at right angles to channel shaped, minimum 8” deep,
18 gage galvanized steel joists 16”o.c.
Face layer 1/2” PABCO®FLAME CURB® type XXX, or 1/2” FLAME
1 hr FC 4340 CURB® Super C gypsum wallboard applied at right angles to
channels with end joints located midway between channels. Sound Test:
Joints offset 24” from base layer joints. 3-1/2” glass fiber batt NRCC B-3163.2
insulation in joist space. IIC & Test: 69;
50- 54 Floor of 5/8” T & G edge plywood applied at right angles to NRCC B-3163.2
joists.
STC tested with 1/4” carpet applied over a 3/8” foam pad.

PABCO® GYPSUM WALLBOARD CEILING, Fire Test:


STEEL CHANNEL JOISTS, PLYWOOD FLOOR Based on
Base layer 1/2” PABCO® FLAME CURB® Super C gypsum UL R3660-7, -8;
wallboard applied at right angles to channel shaped, UL R1319-133;
minimum 7” deep, 18 gage galvanized steel joists 24” o.c. UL R7094,
1 hr NA FC 4502 Face layer 1/2” PABCO® FLAME CURB® Super C gypsum
wallboard applied at right angles to joists. Joints offset from 90NK10635;
base layer joints. Steel joists supporting 5/8” T& G edge UL Design L524
plywood floor applied at right angles to joists. For alternate
floor systems, consult manufacturer.

Two layers 5/8” PABCO® FLAME CURB® Super C type C gypsum Fire Test:
wallboard applied with long dimension perpendicular to UL L527
resilient channels.
Upper layer attached to resilient channels. Butt joints to be
centered under resilient channels.
1.5 Face layer installed perpendicular to resilient channels and
NA -
hr attached to resilient channels through upper layer. All long
edge joints in face layer boards to be offset from long edge
joints in upper layer a min of 16 in. Butt joints of face layer
to occur between resilient channels with each end of butted
boards attached to upper board.

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, Fire Test:


STEEL CHANNEL JOISTS, RIGID FURRING CHANNELS UL R4024,
Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” 02NK04478,
WATER CURB® type X backing board, or 5/8” PABCO® type X UL Design L556;
gypsum sheathing applied at right angles to channel shaped, ULC Design M514
minimum 8” deep, 18 gage galvanized steel joists 24” o.c.
Second layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to joists. Second
layer joints offset 24” from base layer joints.
2 hr NA FC 4750 Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
WATER CURB® type X backing board, or 5/8” PABCO® type X
gypsum sheathing applied at right angles to joists. Third layer
joints offset 12” from second layer joints. Hat-shaped rigid
furring channels 24” o.c. applied at right angles to joists over
third layer.
Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
WATER CURB® type X backing board, or 5/8” PABCO® type X
gypsum sheathing applied at right angles to furring channels.
Joists supporting 3/4” T & G edge plywood floor applied at
right angles to joists.

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #51 SJ 06-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
FLOOR-CEILING STEEL FRAMED (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers

PABCO® GYPSUM WALLBOARD, STEEL JOISTS, CONCRETE SLAB Fire Test:


One layer 1/2” PABCO® FLAME CURB® type XXX, or PABCO® UL R3501-28,
FLAME CURB® Super C gypsum wallboard applied at right UL Design G514;
angles to rigid furring channels 24” o.c. Gypsum board end ULC Design I511
joints located midway between continuous channels and
attached to additional pieces of channel 54” long. Sound Test:
Furring channels attached to open web steel joists 24” NGC 4075
2 hr 50-54 FC 2030
o.c. supporting 3/8” rib metal lath or 9/16” deep 28 gage
corrugated steel and 2-1/2” concrete slab measured from top
of flute. Furring channels may be attached to 1-1/2” cold rolled
carrying channels 48” o.c. suspended from joists.
(Two hour restrained and unrestrained.)
(See GA file No BM 3310)

PABCO® GYPSUM WALLBOARD, STEEL JOISTS, CONCRETE SLAB Fire Test:


One layer 5/8” PABCO® FLAME CURB® Super C gypsum UL R1319-79;
wallboard applied at right angles to furring channels 24” o.c. UL R3501,
(double channels at end joints). 5/8” x 2-3/4” PABCO® FLAME 88NK21023,
CURB® type X gypsum wallboard strips over butt joints. Based on
UL R3660-7, -8;
Furring channels wire tied to open web steel joist 24” o.c.
supporting 3/8” rib metal lath and 2- 1/2” concrete slab. UL R2717-61,
3 hr 50-54 FC 3012
UL Design G512
(Three hour restrained and unrestrained.)
Sound Test:
Est. see FC 2030
(NGC 4075)

to
the ®

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #52 SJ 06-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

FLOOR CEILING - WOOD FRAMED "Quality to the Core"


R

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STCGA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, Fire Test:
WOOD JOISTS UL R6352,
UL Design L502
One layer 1/2” PABCO® FLAME CURB® Super C gypsum
NA wallboard applied at right angles to resilient furring channels
24” o.c. Gypsum board end joints located midway between
continuous channels and attached to additional pieces of
channel 60” long.
1 hr FC 5105
Sound Test:
Resilient channels applied at right angles to 2 x 10 wood joists
16” o.c. Wood joists supporting 19/32” plywood and G&H BW-10 MT
1” proprietary sanded gypsum underlayment. IIC & Test:
55-59 (73 C & P)
STC rated with 3-1/2” glass fiber insulation in joist spaces G&H BW-10 MT
and with carpet and pad. Second layer of 1/2” or 5/8” type X
gypsum wallboard required to achieve 1 hour fire resistance
rating when glass fiber insulation is used.

PABCO® GYPSUM WALLBOARD, RESILIENT CHANNELS, Fire Test:


WOOD JOISTS, GYPSUM FLOOR UNDERLAYMENT UL R1319-65,
UL Design L514
One layer PABCO® 1/2” FLAME CURB® Super C gypsum
wallboard applied at right angles to resilient furring channels
Field Sound Test:
24” o.c. Gypsum board end joints located midway between
1 hr 55-59 FC 5107 continuous channels and attached to additional pieces of
INTEST 5-761-3
channel 54” long. Resilient furring channels applied at right
angles to 2 x 10 wood joists 16” o.c. Wood joists supporting
19/32” plywood subfloor and 3/4” 1000 psi sanded gypsum
floor underlayment.

PABCO® GYPSUM WALLBOARD, WOOD I-JOISTS, Fire Test:


RESILIENT CHANNELS NRCC A-4440.1
(Revised)
Base layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO®
NA 1/2” FLAME CURB® Super C gypsum wallboard applied at right
angles to resilient channels 16" o.c. Resilient channels applied
at right angles to minimum 9-1/2” deep wood I-joists, with
minimum 1-1/4” deep x 1-1/2” wide flanges and minimum 3/8”
webs, 24” o.c.
1 hr FC 5111
Face layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® Sound Test:
1/2” FLAME CURB® Super C gypsum applied at right angles NRCC B-3150.2
to channels. Face layer end joints located midway between IIC & Test:
channels and attached to base layer. Edge joints offset 24” (68 C & P)
50-54 from base layer edge joints. Wood I-joists supporting 5/8” NRCC B-3150.2
oriented strand board applied at right angles to I-joists.
STC and IIC tested with 40 oz carpet over 1/4” foam pad.

PABCO® GYPSUM WALLBOARD, WOOD JOISTS, Fire Test:


RESILIENT CHANNELS, GLASS FIBER INSULATION UL R3453-7
Based on
One layer 5/8” PABCO® FLAME CURB® Super C gypsum UL R3660-7, -8;
wallboard applied at right angles to resilient furring channels R2717-61;
24” o.c. Gypsum board end joints located midway between Based on UL
continuous channels and attached to additional pieces of R7094,
channel 54” long. Resilient furring channels applied at right 90NK10635;
1 hr 50-54 FC 5116 angles to 2 x 10 wood joists 16” o.c. Based on UL
R8742,
Wood joists supporting 5/8” interior plywood with exterior 88NK22591,
glue subfloor and 1-5/8” perlite-sand concrete reinforced with UL Design L516
No. 19 SWG galvanized hexagonal wire mesh. 3” glass fiber Sound Test:
insulation 0.90 pcf in joist space stapled to subfloor. KAL L 224-28-65
IIC & Test:
(74 C & P)
KAL L 224-27-65
PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #53 SJ 06-14-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
FLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, WOOD JOISTS, Fire Test:
RESILIENT CHANNELS, GLASS FIBER INSULATION FM FC-181,
One layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® 8-31-72
1/2” FLAME CURB® Super C gypsum wallboard applied at right
angles to resilient furring channels 24” o.c. Resilient channels
applied at right angles to 2 x 10 wood joists 16" o.c. Wood
joists supporting 5/8" interior plywood with exterior glue
subfloor and 3/8" particleboard, 1.5 psf.
1 hr FC 5120 3-1/2" glass fiber insulation batts, 0.7 pcf, friction fit in joist Sound Test:
cavities, supported by alternately every 12" by wire ords and G&H OC-3MT,
resilient furring channels. 10-31-71
50-54 Sound tested with carpet and pad and with insulation stapled
to joists. IIC & Test:
(73 C & P)
G&H OC-3MT,
10-31-71

PABCO® GYPSUM WALLBOARD, WOOD I-JOISTS, Fire Test:


RESILIENT CHANNELS NRCC A-4440.1
Base layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® (Revised)
1/2” FLAME CURB® Super C gypsum wallboard applied at right
angles to resilient channels 16” o.c. Resilient channels applied Sound Test:
at right angles to minimum 9-1/2” deep wood I-joists, with NRCC B-3150.1
minimum 1-1/4” deep x 1-1/2” wide flanges and minimum 3/8” IIC & Test:
1 hr 45-49 FC 5241 webs, 24” o.c. 40 (68 C & P)
NRCC B-3150.1,
Face layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® NRCC B-3150.2
1/2” FLAME CURB® Super C gypsum wallboard applied at
right angles to channels. Face layer end joints located midway
between channels and attached to base layer. Edge joints
offset 24” from base layer edge joints. Wood I-joists supporting
5/8” oriented strand board applied at right angles to I-joists.

PABCO® GYPSUM WALLBOARD, WOOD JOISTS, Fire Test:


RESILIENT CHANNELS UL R2717-29,
One layer PABCO® 1/2” FLAME CURB® type XXX, or PABCO® UL Design L502;
1/2” FLAME CURB® Super C gypsum applied at right angles ULC Design
to resilient furring channels 24” o.c. Gypsum board end joints M501
located midway between continuous channels and attached
1 hr 45-49 FC 5250 to additional pieces of channel 60” long. Resilient furring Sound Test:
channels applied at right angles to 2 x 10 wood joists 16” o.c. RAL TL64-155
IIC & Test:
Wood joists supporting 1” nominal wood subfloor and 1” 39 (67 C & P)
nominal wood finish floor, or 19/32” plywood finished floor
See FC 5240
with long edges T & G and 15/32” interior plywood with
exterior glue subfloor perpendicular to joists with joints (CK 6512-6)
staggered.

PABCO® GYPSUM WALLBOARD, WOOD JOISTS, Fire Test:


RESILIENT CHANNELS UL R5229-2,
One layer 5/8” PABCO® FLAME CURB® Super C gypsum UL Design L513
wallboard applied at right angles to resilient furring
channels 16” o.c. Sound Test:
Estimated
Gypsum board end joints located midway between
1 hr 35-39 FC 5415 continuous channels and attached to additional pieces of
channel 72” long. Resilient furring channels applied at right
angles to 2 x 10 wood joists 24” o.c. Wood joists supporting
3/4” nominal interior plywood with exterior glue T & G subfloor
perpendicular to joists with joints staggered. Underside of
T & G joints covered between joist spaces with 6” x 22-1/2” x
5/8” type X gypsum wallboard battens attached to flooring.
PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #54 SJ 06-14-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
FLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, WOOD JOISTS Fire Test:
FM FC 172;
Base layer 5/8” FLAME CURB® type X gypsum wallboard,
ITS.
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to 2 x 10 wood
Sound Test:
joists 24” o.c.
Estimated
Face layer 5/8” FLAME CURB® type X gypsum wallboard,
1 hr 35-39 FC 5406 5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to joists. Joints
offset 24” from base layer joints. Wood joists supporting 1/2”
plywood with exterior glue applied at right angles to joists.
Ceiling provides one hour fire resistance protection for
framing, including trusses.

PABCO® GYPSUM WALLBOARD, WOOD I-JOISTS, Fire Test:


FM FC 172,
Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
ITS
WATER CURB® type X backing board, or 5/8” PABCO® type X
gypsum sheathing applied at right angles to wood I-joists 24”
Sound Test:
o.c.
Estimated
Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
WATER CURB® type X backing board, or 5/8” PABCO® type X
1 hr 35-39 FC 5407 gypsum sheathing applied at right angles to I-joists. Joints
offset 24” from base layer joints.
Wood I-joists supporting 1/2” wood structural panels applied
at right angles to joists.
Ceiling provides one hour fire resistance
protection for I-joists.

PABCO® GYPSUM WALLBOARD, WOOD JOISTS Fire Test:


UL R1319-66,
One layer 1/2” PABCO®FLAME CURB® type XXX, or 1/2” FLAME UL Design L512;
CURB® Super C gypsum wallboard applied at right angles to UL R3501-45,
2 x 10 wood joists 16” o.c. UL Design L522;
UL R2717-38,
Wood joists supporting 1” nominal T & G wood subfloor and UL Design L503;
1” nominal wood finish floor, or 19/32” plywood finished UL R3543-6,
1 hr 35-39 FC 5410 floor with long edges T & G, and 15/32” interior plywood UL Design L519;
with exterior glue subfloor perpendicular to joists with joints ULC Design
staggered. M502

Sound Test:
NGC 4024,
IIC & Test:
32 (66 C & P)
NGC 5032

PABCO® GYPSUM WALLBOARD, WOOD JOISTS Fire Test:


UL R3501-5, 9,
One layer 5/8” FLAME CURB® type X gypsum wallboard, UL R1319-2, 3;
5/8” WATER CURB® type X backing board, or 5/8” PABCO® UL Design L 501;
type X gypsum sheathing applied at right angles to ULC Design
2 x 10 wood joists 16” o.c. M500
1 hr 35-39 FC 5420 Wood joists supporting 1” nominal wood subfloor and 1” Sound Test:
nominal wood finish floor, or 19/32” plywood finished floor See FC 5410
with long edges T & G and 15/32” interior plywood with (NGC 4024)
exterior glue subfloor perpendicular to joists with joints IIC & Test:
staggered. 32 (66 C & P)
NGC 5032

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #55 SJ 06-14-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
FLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, WOOD TRUSSES, WOOD Fire Test:
STRUCTURAL PANELS, GYPSUM FLOOR TOPPING, RESILIENT UL R7094,
CHANNELS, GLASS OR MINERAL FIBER BATT OR LOOSE FILL 07NK11121,
INSULATION, CEILING DAMPER UL Design L592;
One layer 5/8” FLAME CURB® type X gypsum wallboard, WFCi
5/8”WATER CURB® type X backing board, or 5/8” PABCO® 07002C/07048
type X gypsum sheathing applied at right angles to resilient
furring channels 12” o.c. Gypsum board end joints located
midway between continuous channels and attached to
additional pieces of channel 60” long located 3” back on either
1 hr NA FC 5520 side of end joint. Resilient channels applied at right angles to
18” deep parallel chord wood trusses 24” o.c. Glass or mineral
fiber batt insulation stapled to subfloor or loose fill insulation
applied directly over gypsum board.
Wood trusses supporting 23/32” wood structural panel
subfloor, long edges T & G, applied at right angles to trusses.
Either 3/4” gypsum floor topping or 15/32” wood structural
panel underlayment applied over subfloor.
Optional ceiling damper (refer to manufacturer for information
on the type of damper).

PABCO® GYPSUM WALLBOARD, WOOD TRUSSES Fire Test:


One layer 5/8” PABCO® FLAME CURB® Super C type C gypsum UL R9500-1,
wallboard applied at right angles to rigid furring channels 80NK15492;
24” o.c. Gypsum board end joints located midway between UL R2717-61;
continuous channels and attached to additional pieces of UL Design L528
channel 60” long.
1 hr NA FC 5515
Rigid furring channels applied at right angles to 12” deep
parallel chord wood trusses 24” o.c. Wood trusses supporting
3/4” nominal interior plywood with exterior glue, T & G edges,
applied at right angles to trusses. End joints staggered 48”.
Consult the gypsum board manufacturer for truss details.

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, Fire Test:


WOOD TRUSSES, RIGID FURRING CHANNELS UL R4024,
Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” 00NK26545,
WATER CURB® type X backing board, or 5/8” PABCO® type X UL Design L556;
gypsum sheathing applied at right angles to 18” deep parallel ULC Design
chord wood trusses 24” o.c. M514
Second layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to trusses. Second
layer joints offset 24” from base layer joints.
Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
2 hr NA FC 5751 WATER CURB® type X backing board, or 5/8” PABCO® type X
gypsum sheathing applied at right angles to trusses. Third
layer joints offset 12” from second layer joints. Hat-shaped
rigid furring channels 24” o.c. applied at right angles to trusses
over third layer.
Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
WATER CURB® type X backing board, or 5/8” PABCO® type X
gypsum sheathing applied at right angles to furring channels.
Wood trusses supporting 3/4” T & G edge plywood floor
applied at right angles to trusses.
Ceiling provides two-hour fire resistance protection for
wood framing.

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #56 SJ 06-14-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
FLOOR-CEILING WOOD FRAMED (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, WOOD JOISTS, Fire Test:


RESILIENT CHANNELS UL R1319-114,
Base layer 5/8” PABCO® FLAME CURB® Super C type C gypsum UL Design L511
wallboard applied at right angles to 2 x 10 wood joists 16”
o.c. Resilient channel 24” o.c. applied at right angles to wood
framing through base layer. Double channel installed at face
layer end joints.
2 hr NA FC 5710
Face layer 5/8” PABCO® FLAME CURB® Super C type C gypsum
wallboard applied at right angles to resilient furring channels.
Wood joists supporting 15/32” plywood subfloor and 19/32”
plywood finish floor applied at right angles to joists with joints
staggered. Consult the gypsum board manufacturer for other
flooring options.

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, Fire Test:


WOOD JOISTS, RESILIENT CHANNELS UL R2717-35,
Base layer 5/8” PABCO® FLAME CURB® Super C type C gypsum UL Design L505;
wallboard applied at right angles to 2 x 10 wood joists 16” o.c. ULC Design
Resilient furring channels 24” o.c. applied at right angles to M503
joists through base layer at each joist.
2 hr NA FC 5724 Face layer 5/8” PABCO® FLAME CURB® Super C type C gypsum
wallboard applied at right angles to resilient furring channels.
Double channel installed at face layer end joints. Wood joists
supporting 1” nominal T & G wood subfloor and 1” nominal
wood finish floor or 19/32” plywood finished floor with long
edges T & G and 15/32” interior plywood with exterior glue
subfloor perpendicular to joists with joints staggered.

PABCO® GYPSUM WALLBOARD, WOOD FLOOR, Fire Test:


WOOD I-JOISTS, RIGID FURRING CHANNELS UL R4024,
Base layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8” 00NK26545,
WATER CURB® type X backing board, or 5/8” PABCO® type X UL Design L556;
gypsum sheathing applied at right angles to 9-1/2” deep wood ULC Design
I-joists 24” o.c. M514
Second layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to I-joists. Second
layer joints offset 24” from base layer joints.
Third layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
WATER CURB® type X backing board, or 5/8” PABCO® type X
2 hr NA FC 5750 gypsum sheathing applied at right angles to I-joists. Third layer
joints offset 12” from second layer joints.
Hat-shaped rigid furring channels 24” o.c. applied at right
angles to I-joists over third layer.
Face layer 5/8” FLAME CURB® type X gypsum wallboard, 5/8”
WATER CURB® type X backing board, or 5/8” PABCO® type X
gypsum sheathing applied at rightangles to furring channels.
Wood I-joists supporting 3/4” T & G edge plywood floor applied
at right angles to I-joists.
Ceiling provides two-hour fire resistance protection for wood
framing.

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #57 SJ 06-14-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

ROOF CEILING - WOOD FRAMED "Quality to the Core"


R

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers
PABCO® GYPSUM WALLBOARD, WOOD ROOF TRUSSES, Fire Test:
RESILIENT CHANNELS, GLASS OR MINERAL FIBER INSULATION, UL R7094,
CEILING DAMPER 07NK11121,
UL Design P549;
One layer 5/8” FLAME CURB® Super C type C gypsum
WFCi
wallboard applied at right angles to resilient furring channels
07002C/07048
16” o.c. (12” o.c. when insulation is draped over channels).
Gypsum board end joints attached with screws 8” o.c. to
additional pieces of channel 60” long located 3” back on either
1 HR NA RC 2608 side of end joint.
Resilient channels applied at right angles to bottom chord of
pitched wood trusses 24” o.c. Optional glass fiber or mineral
fiber batt insulation secured to wood structural panels or
applied directly over gypsum board. Trusses supporting 15/32”
wood structural panels applied at right angles to trusses.
Optional ceiling damper (refer to manufacturer for information
on the type of damper).

PABCO® GYPSUM WALLBOARD, WOOD TRUSSES Fire Test:


FM FC 172;
Base layer 5/8” FLAME CURB® type X gypsum wallboard,
ITS
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to wood roof
trusses 24” o.c.
Face layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
1 HR NA RC 2602 X gypsum sheathing applied at right angles to trusses. Joints
offset 24” from base layer joints. Wood trusses supporting
1/2” wood structural panels applied at right angles to trusses.
Appropriate roof covering.
Ceiling provides one hour fire resistance protection for
trusses.

PABCO® GYPSUM WALLBOARD, RIGID FURRING CHANNELS Fire Test:


WOOD JOISTS or WOOD I-JOISTS, ROOF COVERING UL R4024,
00NK26545,
Base layer 5/8” FLAME CURB® type X gypsum wallboard,
UL R4042,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
03NK11206;
X gypsum sheathing applied at right angles to either 2 x 8
UL Design L556;
wood joists or 9-1/2” deep wood I-joists 24” o.c.
ULC Design
Second layer 5/8” FLAME CURB® type X gypsum wallboard, M514
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to joists or I-joists.
Second layer joints offset 24” from base layer joints.
Third layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
2 HR NA RC 2750 X gypsum sheathing applied at right angles to joists or I-joists.
Third layer joints offset 12” from second layer joints.
Hat-shaped rigid furring channels 24” o.c. applied at right
angles to joists or I-joists over third layer.
Face layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
type X gypsum sheathing applied at right angles to furring
channels. Wood joists or I-joists supporting 3/4” T & G
edge plywood applied at right angles to joists or I-joists.
Appropriate roof covering.
Ceiling provides two-hour fire-resistance protection for
wood framing.

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #58 SJ 06-14-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
ROOF-CEILING Wood Framed (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE STC GA
Rating Rating File No Construction Detail Description Test
Numbers

PABCO® GYPSUM WALLBOARD, WOOD ROOF TRUSSES, Fire Test:


RIGID FURRING CHANNELS UL R4024,
00NK26545,
Base layer 5/8” FLAME CURB® type X gypsum wallboard,
UL Design L556;
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
ULC Design
X gypsum sheathing applied at right angles to wood roof
M514
trusses 24” o.c.
Second layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to trusses. Second
layer joints offset 24” from base layer joints.
Third layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO® type
X gypsum sheathing applied at right angles to trusses. Third
2 HR NA RC 2751
layer joints offset 12” from second layer joints. Hat-shaped
rigid furring channels 24” o.c. applied at right angles to trusses
over third layer.
Face layer 5/8” FLAME CURB® type X gypsum wallboard,
5/8” WATER CURB® type X backing board, or 5/8” PABCO®
type X gypsum sheathing applied at right angles to furring
channels.
Wood trusses supporting 3/4” T & G edge wood structural
panels applied at right angles to trusses. Appropriate roof
covering.
Ceiling provides two-hour fire-resistance protection for
wood framing.

to
the ®

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #59 SJ 06-14-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

COLUMNS - Noncombustible "Quality to the Core"


R

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

FIRE STCGA Construction Detail Fire & Sound


Rating Rating File No - Description Test
Light Tubular Column Numbers
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL NC505,
Base layer 1/2” PABCO® FLAME CURB® type XXX gypsum
77NK1747;
wallboard applied without horizontal joints to 1-5/8” steel
UL Design X528
studs located at each corner of TS 4x4x0.188 tube steel
1 hr NA CM 1452 column.
Face layer 1/2” PABCO® FLAME CURB® type XXX gypsum
wallboard applied without horizontal joints to studs.
Metal cornerbead applied to all corners. Joint compound 1/16”
thick applied over corner bead.
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL NC505,
One layer 5/8” PABCO® FLAME CURB® type X gypsum
77NK1747;
wallboard, 5/8”WATER CURB® type X backing board, or
UL Design X528
5/8” PABCO® type X gypsum sheathing applied without
1 hr NA CM 1851 horizontal joints and parallel to 1-5/8” steel studs located at
each corner of TS 8x8x0.250 tube steel column.
Steel cornerbead, 1-1/2” flanges, applied. Joint compound
1/16” thick applied over corner bead.
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL X531
Two layers of 1/2" PABCO® FLAME CURB® Super C type
PG -C gypsum wallboard applied vertically to 1-5/8" steel
studs and channels, furred from 4-1/2" min OD steel pipe
1.5 column (min wall thickness 0.109” and min
NA NA
hr 5.1 lbs/ft weight). Channels tied to column with
No. 18 SWG tie wire.
Steel cornerbead, 1-1/4” legs, applied. Joint compound
1/16” thick applied over corner beads, joints, and surfaces of
wallboard.
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL NC505,
Base layer 1/2” PABCO® FLAME CURB® type XXX, or
77NK1747;
1/2” FLAME CURB® Super C gypsum wallboard applied
UL NC505;
without horizontal joints to 1-5/8” steel studs located at each
UL Design X528
corner of TS 4x4x0.188 tube steel column .
Second layer 5/8” PABCO® FLAME CURB® type X gypsum
2 hr NA CM 2455 wallboard, 5/8” WATER CURB® type X backing board, or
5/8” PABCO® type X gypsum sheathing applied without
horizontal joints.
Face layer 5/8” PABCO® FLAME CURB® type X gypsum
wallboard, 5/8” WATER CURB® type X backing board, or
5/8” PABCO® type X gypsum sheathing applied without
horizontal joints to studs. Metal corner bead applied to all
corners. Joint compound 1/16” thick applied over corner bead

Column 10WF-49
Fire Test:
PABCO® GYPSUM WALLBOARD, STEEL STUDS
UL NC505,
One layer 1/2” PABCO® FLAME CURB® type XXX, or 77NK1747;
1/2” FLAME CURB® Super C gypsum wallboard applied without UL Design X528
horizontal joints to 1-5/8” steel studs located at each corner of
1 hr NA CM 1001 W10x49 column. Metal corner bead applied to all corners.
Joint compound 1/16” thick applied over corner bead.

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #60 SJ 06-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS
COLUMNS -Noncombustible (continued)

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Construction Detail Fire & Sound


FIRE STC GA
Rating Rating File No - Description Test
Column 10WF-49 Numbers
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL NC505,
Base layer 5/8” PABCO® FLAME CURB® type X gypsum
77NK1747;
wallboard, 5/8”WATER CURB® type X backing board, or
UL Design X528
5/8” PABCO® type X gypsum sheathing applied without
horizontal joints to 1-5/8” steel studs located at each corner of
2 hr NA CM 2017 W10x49 column.
Face layer 1/2” PABCO® FLAME CURB® Super C type PG -C
gypsum wallboard applied without horizontal joints to studs.
Metal corner bead applied to all corners.
Joint compound 1/16” thick applied over corner bead
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL R2717-31,
Base layer 5/8” PABCO® FLAME CURB® type X gypsum
UL Design X509;
wallboard, 5/8”WATER CURB® type X backing board, or
UL R3501-36,
5/8” PABCO® type X gypsum sheathing applied to 1-5/8” steel
UL Design X510;
studs located at each corner of W10x49 column.
ULC Design Z502
Second layer 5/8” PABCO® FLAME CURB® type X gypsum
3 hr NA CM 3120
wallboard, 5/8”WATER CURB® type X backing board, or
5/8” PABCO® type X gypsum sheathing applied to studs.
Face layer 5/8” PABCO® FLAME CURB® type X gypsum
wallboard, 5/8”WATER CURB® type X backing board, or
5/8” PABCO® type X gypsum sheathing applied to studs.
Metal corner bead applied at all corners.

Base Layer and Second layer 5/8” PABCO® FLAME CURB® Fire Test:
Super C Type C gypsum wallboard applied to 1-5/8” steel studs UL Design X501
located at each corner of W10x49 column.
Third layer and Face layer 5/8” PABCO® FLAME CURB® Super C
4 hr NA NA Type C gypsum wallboard applied to 2" x 2" sheet metal angles
placed at the corners of the second layer of wallboard.
Metal corner bead applied at corners and covered with joint
compound treatment.

Column 14WF-228
PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:
UL R3501-58,
One layer 1/2” PABCO® FLAME CURB® type XXX, or
UL Design X520;
1/2” FLAME CURB® Super C gypsum wallboard attached
ULC Design X520
to 1-5/8” steel studs located at each corner of heavy steel
2 hr NA CM 2110 W14x228 columns. 1-1/4” metal corner bead applied by
crimping 6” o.c.

PABCO® GYPSUM WALLBOARD, STEEL STUDS Fire Test:


UL R3501-61,
Base layer 1/2” PABCO® FLAME CURB® type XXX, or
UL Design X513;
1/2” FLAME CURB® Super C gypsum wallboard applied to
ULC Design X513
1-5/8” steel studs located at corners of heavy steel W14x228
3 hr NA CM 3130 column.
Face layer 1/2” PABCO® FLAME CURB® type XXX, or
1/2” FLAME CURB® Super C gypsum wallboard applied to
studs. 1” corner bead applied.

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #61 SJ 06-07-11/ Fire Rated Systems- PABCO® Gypsum


FIRE RATED SYSTEMS a division of PABCO® building products, LLC

BEAMS & GIRDERS - Noncombustible "Quality to the Core"


R

Please refer to the referenced test report for construction details.


Assemblies listed are examples of systems where PABCO Gypsum board products have been approved for use.
Additional assemblies are available. For more information please contact PABCO Gypsum Technical Services at 866-282-9298, or email to techservice@paccoast.com. www.pabcogypsum.com

Fire & Sound


FIRE GA
Rating File No Construction Detail Description Test
Numbers

PABCO® GYPSUM WALLBOARD, STEEL FRAME Fire Test:


UL R1319-133;
Base layer 1/2” PABCO® FLAME CURB® Super C type PC-C
Based on UL
gypsum wallboard applied to beam cage.
R3660-7 & -8;
Face layer 1/2” PABCO® FLAME CURB® Super C type PC-C UL Design L524
gypsum wallboard applied to beam cage. Joints offset
from base layer joints.
1 hr BM 1137 Beam cage fabricated from No. 24 gage 7/8” x 1-3/8” steel
angles screw attached to steel joists at beam top flange
and No. 25 gage 2-1/2” steel runners hooked over beam
lower flange and supporting 1-5/8” steel studs 24” o.c.
Minimum beam size W8x15.
(One hour unrestrained beam.)

PABCO® GYPSUM WALLBOARD, STEEL FRAME Fire Test:


UL R4024-5,
Base layer 5/8” PABCO® FLAME CURB® type X gypsum
UL Design N501;
wallboard, 5/8”WATER CURB® type X backing board, or
ULC Design O501
5/8” PABCO® type X gypsum sheathing applied to beam
cage.
Face layer 5/8” PABCO® FLAME CURB® type X gypsum
wallboard, 5/8”WATER CURB® type X backing board, or
5/8” PABCO® type X gypsum sheathing applied to beam
2 hr BM 2120 cage.
Beam cage fabricated from horizontally installed steel
angles (25 gage steel having 1” and 2” legs). “U” shaped
brackets formed of 25 gage “U” shaped steel channels
(1-11/16” wide with 1” legs) 24” o.c. suspended from upper
angles.
Minimum beam size W8x24.
(Two hour restrained or unrestrained beam.)

to
the ®

PABCO®, FLAME CURB®, WATER CURB®, PABCORE®, MOLD CURB®, ABUSE CURB™, “Quality to the Core”®, are registered trademarks of Pacific Coast Building Products and licensed to PABCO® Gypsum

Page #62 SJ 06-07-11/ Fire Rated Systems- PABCO® Gypsum


Quality Matters.

At PABCO® Gypsum, quality is a serious part of our business;


a core fundamental value.
It’s what sets us apart from our competitors,
a core key-success-factor, a commitment to you.
It’s why customers ask for our products,
and why they come back year after year.
PABCO® Gypsum, Commitment to the Core™

Quality to the Core


®
to
the ®

MGM CityCenter, Las Vegas, NV: utilized approximately 18 mil sf of PABCO® Gypsum wallboard

Technical Service • Literature • Samples Limited Warranty: PABCO® Building Products, LLC, warrants that on
the date the gypsum board is shipped from its manufacturing plant
the gypsum board is free from defects in materials and manufacture.
NOTWITHSTANDING THE FOREGOING, IT IS THE RESPONSIBILITY OF THE

866-282-9298 GYPSUM BOARD APPLICATOR TO NOTIFY PABCO BUILDING PRODUCTS,


LLC, IN WRITING WITHIN TWENTY FOUR (24) HOURS OF DISCOVERY
OF ANY VISIBLY DEFECTIVE GYPSUM BOARD PRIOR TO SUCH VISIBLY
DEFECTIVE GYPSUM BOARD BEING APPLIED; FAILURE TO DO SO MAY

techservice@paccoast.com FURTHER LIMIT OR VOID THE RESPONSIBILITIES OF PABCO BUILDING


PRODUCTS, LLC, UNDER THIS WARRANTY. This warranty will remain in
place for one year from the date of shipment from the manufacturing
plant. THIS EXPRESS WARRANTY IS THE EXCLUSIVE WARRANTY PROVIDED

www.PabcoGypsum.com BY PABCO® BUILDING PRODUCTS, LLC, AND SUPERSEDES ANY PRIOR,


CONTRARY OR ADDITIONAL REPRESENTATIONS, WHETHER ORAL OR
WRITTEN. PABCO® BUILDING PRODUCTS, LLC, HEREBY DISCLAIMS AND
EXCLUDES ALL OTHER WARRANTIES – WHETHER EXPRESS, IMPLIED, OR
STATUTORY – INCLUDING ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED
WARRANTIES OTHERWISE ARISING FROM COURSE OF DEALING OR USAGE
OF TRADE.
If the gypsum board fails to conform to the foregoing warranty in
Paragraph 1 and such nonconformity is not due to misuse or improper
maintenance or storage, Buyer shall notify PABCO® Building Products, LLC,
in writing, and within 60 days of discovery, PABCO® Building Products,
LLC, shall provide, at its sole and absolute discretion, one of the following:
(i) repair or replacement of any nonconforming or defective gypsum
wallboard; or (ii) credit or full refund of the purchase price. THIS REMEDY
SHALL BE THE EXCLUSIVE AND SOLE REMEDY OF BUYER FOR ANY BREACH
OF WARRANTY.
IN NO EVENT SHALL PABCO® BUILDING PRODUCTS, LLC, BE LIABLE FOR ANY
INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, WHETHER
RESULTING FROM NONDELIVERY OR FROM THE USE, MISUSE, OR INABILITY
TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT OR FROM
NEGLIGENCE OR OTHER TORT. This exclusion applies regardless of whether
such damages are sought for breach of warranty, breach of contract,
negligence, or strict liability in tort or under any other legal theory.
Trademarks: The following trademarks used herein are
a division of PABCO® building products, LLC owned by Pacific Coast Building Products and licensed to
PABCO® Gypsum: PABCO®, PABCORE®, FLAME CURB®,
WATER CURB®, MOLD CURB®, Quality to the Core®, ABUSE CURB™.
PABCO® Gypsum Construction Guide - Fire & Sound Rated Systems Notice: Products described herein may not be available in all
Copyright © 2009, 2011 • 2nd Edition geographic markets. Consult your PABCO® Gypsum sales representative for
information or call our Technical Services.
PABCO® Gypsum • a division of PABCO® Building Products, LLC
Current updated information is available on our website:
PO Box 417094 • Rancho Cordova • CA • 95741 www.pabcogypsum.com. The information in this publication may change
www.pabcogypsum.com; 7-2011; 3M without notice.

You might also like