Professional Documents
Culture Documents
GHS Classification
of the substance or mixture Not classified.
Label elements
Hazard symbol None.
Signal word None.
Hazard statement None.
Precautionary statement
Response If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for
breathing.
If
on
skin,
wash
with
plenty
of
soap
and
water.
If in eyes, rinse cautiously with water for several minutes.
Get medical attention/advice if you feel unwell.
Storage Store material in a cool, dry, ventilated area, away from excessive heat or sunlight.
2/7
Panel Rey® Gypsum Board
[EXTERIOR REY X®]
Safety Data Sheet
According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Methods for cleaning up Sweep or vacuum remaining material into a waste container for disposal. Use a light water spray to
minimize dust generation. Maintain proper ventilation to minimize dust.
3 3
Ingredient ACGIH TLV (mg/m ) U.S. OSHA PEL (mg/m )
(8-hr. TWA) (8-hr. TWA)
Gypsum (CaSO42H2O) 10 15 (T) / 5 (R)
Or Anhydrous Calcium Sulfate 10 15 (T) / 5 (R)
Recycled paper (Cellulose) 10 15 (T) / 5 (R)
May contain the following:
3/7
Panel Rey® Gypsum Board
[EXTERIOR REY X®]
Safety Data Sheet
According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
UL GREENGUARD Gold Certification Criteria for Building Products and Interior Finishes
Criteria Product identifier (CAS No.) Maximum Allowable Units
Predicted Concentration
3
TVOC (A) - 0.22 mg/m
3
Formaldehyde 50-00-0 9 (7.3 ppb) µg/m
Total Aldehydes (B) - 0.043 Ppm
3
4-Phenylcyclohexene 4994-16-5 6.5 µg/m
3
Particle Matter less than 10 µm (C) - 20 µg/m
3
1-Methyl-2-pyrrolidinone (D) 872-50-4 160 µg/m
½ CREL
Individual VOCs (E) - or -
th
1/100 TLV
(A)
Defined
to
be
the
total
response
of
measured
VOCs
falling
within
(B)
The
sum
of
all
measured
normal
aldehydes
from
formaldehyde
through
nonanal,
plus
benzaldehyde,
individually
calibrated
to
a
the
C6
–
C16
range,
with
responses
calibrated
to
a
toluene
surrogate.
compound
specific
standard.
Heptanal
through
nonanal
are
measured
via
TD/GC/MS
analysis
and
the
remaining
aldehydes
are
measured
using
HPLC/UV
analysis.
(C)
Particle
emission
requirement
only
applicable
to
HVAC
Duct
Products
with
exposed
surface
area
in
air
streams
(a
forced
air
test
(D)
Based
on
the
CA
Prop
65
Maximum
Allowable
Dose
Level
for
inhalation
of
3,200
g/day
and
an
inhalation
rate
of
20
m³/day.
with
specific
test
method)
and
for
wood
finishing
(sanding)
systems. (E)
Allowable
levels
for
chemicals
not
listed
are
derived
from
the
lower
of
1/2
the
California
Office
of
Environmental
Health
Hazard
Assessment
(OEHHA)
Chronic
Reference
Exposure
Level
(CREL)
as
required
per
the
CDPH/EHLB/Standard
Method
v1.1
and
BIFMA
level
credit
7.6.2
and
1/100th
of
the
Threshold
Limit
Value
(TLV)
industrial
work
place
standard
(Reference:
American
Conference
of
Government
Industrial
Hygienists,
6500
Glenway,
Building
D-‐7,
and
Cincinnati,
OH
45211-‐4438).
4/7
Panel Rey® Gypsum Board
[EXTERIOR REY X®]
Safety Data Sheet
According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
5/7
Panel Rey® Gypsum Board
[EXTERIOR REY X®]
Safety Data Sheet
According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
ADR
Transport document description :
Transport by sea
No additional information available
Air transport
No additional information available
EU-Regulations
No additional information available
6/7
Panel Rey® Gypsum Board
[EXTERIOR REY X®]
Safety Data Sheet
According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
NFPA health hazard : 1 - Exposure could cause irritation but only minor residual
injury even if no treatment is given.
NFPA fire hazard : 0 - Materials that will not burn.
NFPA reactivity : 0 - Normally stable, even under fire exposure conditions,
and are not reactive with water.
This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only. It should not therefore be construed as
guaranteeing any specific property of the product
7/7