You are on page 1of 29

INSTRUCTIONS MANUAL

SPLIT TYPE ROOM AIR CONDITIONER

S5(04-07)FM_English_R410A_130320A

MODELS:
• FAS(C,E)09F2MBHLW
• FAS(C,E)12F2MBHLW
• FAS(C,E)18F2MBHLW
• FAS(C,E)24F2MBHLW

ATTENTION
Please read this manual completely
before operating your room air conditioner.

Downloaded from www.Manualslib.com manuals search engine


Welcome to the world of Contents
simple handling and no worries.
Thank you for choosing Frigidaire. This manual contains all of the information Welcome.........................................................................................................01
required to guarantee your safety and the appropriate use of your air
Environmental advices.........................................................................................01
conditioner.
Please read all of the instructions before using the air conditioner and keep this Contents..........................................................................................................02
manual for future reference.
Safety precautions..........................................................................................04
We know you will enjoy your new air conditioner and thank you for choosing
our product. We hope you will consider us for future purchase. Choosing the installation site.....................................................................08
Parts list.........................................................................................................10
Indoor unit installation ...........................................................................................12
Outdoor unit installation...........................................................................16
Refrigerant pipe connection...................................................................18
Electrical work.....................................................................................20
Electrical safety.................................................................................28
Environmental advices Operation test........................................................................................................29
The packaging material used is Preparing the device for operation.......................................................................30
recyclable; we recommend that you
Product description..................................................................................31
separate plastic, paper and cardboard
and give them to recycling companies. Remote control....................................................................................................33
According to WEEE (Waste of Electrical
Remote control description ..................................................................................35
and Electronic Equipment) guidelines,
waste from electrical and electronic LCD display indicators .........................................................................................38
devices should be collected separately. If
Clock adjustment.....................................................................................39
you need to dispose of this appliance in
the future, do NOT throw it away with the How the air conditioner works .............................................................................40
rest of your domestic garbage. Instead,
How to use the indoor unit.....................................................................................46
please take the appliance to the nearest
WEEE collection point, where available. Manual operation (without remote control) ..........................................................48
Maintenance..........................................................................................49
Operation tips...................................................................................51
Solutions for problems..............................................................................53
Technical specifications........................................................................................54

01 02

Downloaded from www.Manualslib.com manuals search engine


Safety precautions

Attention To prevent injury to the user or other people and property damage, the following
instructions must be followed.
The air conditioner that you have
bought may be slightly different Incorrect operation due to ignoring of instructions may cause harm or damage.
from the one illustrated in this The seriousness is classified by the following indications.
manual. Please refer to the
information related to the model
you have.

This air conditioner is for 1. Connect with the power properly.


domestic use only. It is not Otherwise, it may cause electric
reccomended for commercial or
shock or fire due to excess heat
industrial use.
generation.
The air conditioner you have may 2. Do not modify power cord length
carry a different plug than the one or share the outlet with other
illustrated in this manual. The plug appliances. It may cause electric
that comes with the product shock or fire due to heat
follows the electrical specification generation.
of the country where it is sold. 3. Always ensure effective earthing.
No earthing may cause electric
shock.
4. Disconnect the power if strange
sounds, smell, or smoke comes
from it. It may cause fire and
electric shock.
5. Keep firearms away. It may cause
fire.
6. Do not operate or stop the unit by
switching on or off the power. It
may cause electric shock or fire
due to heat generation.
7. Do not operate with wet hands or
in damp environment. It may cause
electric shock.
8. Do not allow water to run into
electric parts. It may cause failure
of machine or electric shock.
9. Do not drink water drained from air

03 04

Downloaded from www.Manualslib.com manuals search engine


conditioner. It contains contaminants 20.Ventilate the room well when used
and could make you sick. together with a stove, etc. An
10.Do not use the power cord close to oxygen shortage may occur.
heating appliances. It may cause 21.When the unit is to be cleaned,
fire and electric shock. switch off, and turn off the circuit
11.Do not damage or use an breaker. Do not clean unit when
unspecified power cord. It may power is on as it may cause fire
cause electric shock or fire. and electric shock, it may cause
an injury.
12.Do not direct airflow at room
occupants only. This could damage 22.Do not put a children, pet or house
your health. plant where it will be exposed to
direct air flow. This could injure the
13.Always install circuit breaker and a
pet or plant.
dedicated power circuit. No
installation may cause fire and 23.Do not use for special purposes.
electric shock. Do not use this air conditioner to
preserve precision devices, food,
14.Do not open the unit during
pets, plants, and art objects. It
operation. It may cause electric
may cause deterioration of quality,
shock.
etc.
15.Do not use the power cord near
24.Stop operation and close the
flammable gas or combustibles,
window in storm or hurricane.
such as gasoline, benzene, thinner,
Operation with windows opened
etc. It may cause an explosion or
may cause wetting of indoor and
fire.
soaking of household furniture.
16.Ventilate room before operating air
25.Turn off the main power switch
conditioner if there is a gas leakage
when not using the unit for a long
from another appliance. It may
time. It may cause failure of
cause explosion, fire and, burns.
product or fire.
17.Do not disassemble or modify unit.
26.Do not use strong detergent such
It may cause failure and electric
as wax or thinner. Use a soft cloth
shock.
for cleaning. Appearance may be
18.When the air filter is to be removed, deteriorated due to change of
do not touch the metal parts of the product color or scratching of its
unit. It may cause an injury. surface.
19.Do not clean the air conditioner 27.Ensure that the installation bracket
with water. Water may enter the of the outdoor appliance is not
unit and degrade the insulation. It damaged due to prolonged
may cause an electric shock. exposure. If bracket is damaged,
there is concern of damage due to

05 06

Downloaded from www.Manualslib.com manuals search engine


Choosing the installation site

falling of unit.
Precautions for Installation
28.Always insert the filters securely.
Installation at the following sites may cause problems. If you must inevitably
Clean filter once every two weeks. install the unit at one of these sites, please consult your local distributor
Operation without filters may beforehand:
cause failure.
1. Site with machine oil.
29.Do not place heavy object on the
power cord and take care so that 2. Sites with a high concentration of salinity, such as coastal areas.
the cord is not compressed. There 3. Sites with sulfuric gas, such as hot water springs.
is danger of fire or electric shock. 4. Sites with high frequency equipment, such as wireless equipment, welding
30.Do not place obstacles around air- machines and medical installations.
inlets or inside of air-outlet. It may 5. Sites with flammable gases or volatile material.
cause failure of appliance or
accident. 6. Sites with special environmental conditions.
7. Laundry rooms.

Indoor Unit 7. The indoor unit must be at least 2.3


1. The unit must be installed at a site meters (7.5 feet) from the ground.
that does not obstruct the flow of 8. The site must allow for the easy
air. removal of the connector pipe and
2. The site must support the weight drain hose.
of the indoor unit. 9. The unit must be installed at a site
3. The site must be easily accessible protected from direct sunlight.
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the
More
indoor unit, as shown in the than 15cm
following figure.
More
5. There should be at least 1 meter (3 than 12cm
feet) between the unit and radio
and television devices. It is ideal More
that the unit be installed at the than 12cm
center of the environment. More
than 200cm
6. It must be far from fire, smoke or
flammable gases.

07 08

Downloaded from www.Manualslib.com manuals search engine


Parts list

Outdoor Unit More


More
More than 60cm NUMBERING PART NAME QTY.
1. The outdoor unit must be installed than 30cm than 30cm
at a convenient site that is not 1 Installation plate 1
exposed to strong winds. The site 2 Clip anchor 5-8
should be dry and well ventilated.
3 Self-tapping screw A ST3.9x25 5-8
2. The site must support the weight
of the outdoor unit and allow for 4 Seal 1
vertical installation. 5 Drain Joint 1
3. There must not be the possibility of Ø6,35
6 Connecting Liquid side Parts you must
increased noise and vibration at More
pipe
Ø9,52 purchase
than 200cm More Ø9,52
the site. than 60cm assembly*
Gas side
Ø12,7
4. The unit must be installed at a site Ø16
where the noise produced by its 7 Remote controller 1
operation and air discharge does
not disturb the neighbors or 8 Self-tapping screw B ST2.9x10 (optional) 2
animals. 9 Remote controller holder (optional) 1
5. The site cannot have any leakage 10 Air freshening filter(installed on Air filter) 1
of flammable gases.
6. The site must allow for a piping
extension of no less than 5 meters
(16 feet) and for pipes measuring
at least 10 meters (33 feet) in
length.
9
7. The site must provide enough 8
space around the unit, as shown in Indoor unit 8
7
the diagram.
8. Children must not be able to
access the installation site. 4 5

1 3 2
Outdoor unit

09 10

Downloaded from www.Manualslib.com manuals search engine


Indoor unit installation

Installation plate description


1
More than 15cm
2 3
Indoor unit
More than 12cm

41

45
6
More than 12cm
Air filter
2,3m or more 6
More than 60cm

More than 30cm


7
A More than
60cm

41
4

45
5
B C
More than 200cm Outdoor
unit

Attention
45

1. This illustration is for explanation purposes only.


2. Copper lines must be insulated independently

11 12

Downloaded from www.Manualslib.com manuals search engine


Connective pipe and drainage installation

Drainage Do not block


Do not block
water flow
1. Run the drain hose sloping water flow by a rise.
by a rise.
downward. Do not install the drain
hose as illustrated below.
2. When connecting extension drain
hose, insulate the connecting part Do not put the end
of extension drain hose with a of drain hose into water.
shield pipe, do not let the drain
hose slack.

24k Btu models


Connective pipe installation
Fixing the installation plate Pipe cover Pipe Pipe cover
Attention 1. For the left-hand and right-hand (right) holder (left)
1. Install the installation plate piping, remove the pipe cover from
horizontally over the structural Fit the Installation Plate and drill holes the side panel.
parts on the wall using the spaces in the wall according to the wall
indicated on the plate, as shown in 2. For the rear-right-hand and rear-left-
structure and corresponding mounting
the figure above. hand piping, install the piping as
points on the installation plate
2. In the case of tiled, concrete or shown. Bend the connective pipe to
(Dimensions are in “mm” unless Right back
similar walls, create 5 mm- otherwise stated). be laid at 43mm height or less from Right piping
piping
diameter holes. Place anchorage the wall.
Indoor unit Connective
supports for the appropriate 3. Fix the end of the connective pipe. outline pipe
Installation plate
assembly screws.
3. If expansion screws are used, the

43mm
holes must measure 11x20 or
11x26, with a distance of 450 mm
between each.
4. Fix the installation plate to the wall. Fastening the Indoor Unit
Wall 1. Pass the piping through the hole in Upper hook
Drilling the Hole the wall.
Indoor unit Outdoor unit
1. Determine the position of the hole 2. Put the upper claw at the back of the
for the pipe using the installation indoor unit on the upper hook of the
plate and drill the pipe hole (ø installation plate, move the indoor
65mm) so that it is titled slightly unit from side to side to see that it is
downward. securely hooked (see Fig.10 &
Fig.11). Lower hook
5-7mm

2. Always use a pipe cover with an


opening when drilling a metal bar.

13 14

Downloaded from www.Manualslib.com manuals search engine


Outdoor unit installation

3. Piping can easily be made by lifting 1. Install the outdoor unit on a rigid
the indoor unit with a cushioning base to prevent increasing noise
material between the indoor unit level and vibration.
and the wall. Get it out after finish 2. Determine the air outlet direction
piping. where the discharged air is not
4. Push the lower part of the indoor unit blocked. In the case that the
up on the wall, then move the installation place is exposed to
indoor unit from side to side, up and Cushioning strong wind such as a seaside,
down to check if it is hooked material make sure the fan operating
securely. properly by putting the unit
lengthwise along the wall or using
a dust or shield plates.
3. Specially in windy area, install the
unit to prevent the admission of
wind. If need suspending
installation, the installation bracket
Piping and wrapping Ponding should accord with technique
1. Bundle the tubing, connecting box requirement in the installation
Indoor unit
cable, and drain hose with tape bracket diagram.
securely, evenly as shown. Cable
Pipe room 4. The installation wall should be solid Strong wind
2. Because the condensed water de conexión brick, concrete or the same
from rear of the indoor unit is intensity construction, or actions to
Connective
gathered in ponding box and is pipe reinforce, damping supporting
piped out of room. Do not put should be taken. The connection
anything else in the box. Drain hose Wrapping
belt between bracket and wall, bracket
and the air conditioner should be
firm, stable and reliable.
5. Be sure there is no obstacle which
block radiating air.
Attention
1. Connect the indoor unit first, then the outdoor unit. MODEL Width (mm) Height (mm) Depht (mm)
2. Do not allow the piping to let out from the back of the indoor unit.
9000 Btu 680 255 180
3. Be careful not to let the drain hose slack.
4. Heat insulated both of the auxiliary piping. 12000 Btu 770 255 188
5. Be sure that the drain hose is located at the lowest side of the bundle.
18000 Btu 905 275 198
Locating at the upper side can cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring. 24000 Btu 1030 315 220
7. Run the drain hose sloped downward to drain out the condensed water
smoothly.

15 16

Downloaded from www.Manualslib.com manuals search engine


Refrigerant pipe connection
A
Settlement of outdoor unit Flaring work
Air inlet
Anchor the outdoor unit with
a bolt and nut 10 or 8 tightly Main cause for refrigerant leakage is
and horizontally on a concrete Air due to defect in the flaring work.
inlet
or rigid mount. B Carry out correct flaring work using Pipe
the following procedure:

Air outlet 1. Cut the pipes and the cable.


Outdoor unit dimension Mounting dimensions
A) Use the piping kit accessory or
mm - (WxHxD) A(mm) B(mm) pipes purchased locally.
B) Measure the distance between the Correct Wrong
700x540x240 458 250
indoor and the outdoor unit. Oblique Roughness Burr
685x430x260 460 276 C) Cut the pipes a little longer than
780x540x250 459 276 the measured distance.
D) Cut the cable 1.5m longer than the
760x590x285 530 290 pipe length.
775x545x310 560 335
845x700x320 600 320 2. Burr removal
670x540x250 481 276 A) Completely remove all burrs from Pipe
the cut cross section of pipe/tube.
760x590x285 530 290 B) Put the end of the copper Reamer
24k Btu models tube/pipe in a downward direction as Point
820x590x330 523 340
down
you remove burrs in order to avoid
845x700x320 560 335 dropping burrs into the tubing.
Drain joint installation
Fit the seal into the drain elbow, then
insert the drain joint into the base pan 3. Putting nut on Flare nut
hole of outdoor unit, rotate 90 to A) Remove flare nuts attached to
securely assemble them. indoor and outdoor unit, then put
Base pan hole Cooper tube
Connecting the drain joint with an of outdoor unit
them on pipe/tube having completed
extension drain hose (Locally burr removal.(not possible to put them
purchased), in case of the water on after flaring work)
draining off the outdoor unit during the
heating mode.
Seal

+ =
Seal Drain joint Drain pipe

17 18

Downloaded from www.Manualslib.com manuals search engine


Electrical work

4. Flaring work Electric safety regulations for the initial Installation


A) Firmly hold copper pipe in a die in 1. If there is serious safety problem 5. According to the attached Electrical
Bar
the dimension shown in the table Copper about the power supply, the Connection Diagram located on the
below. pipe technicians should refuse to install panel of the outdoor unit to connect
the air conditioner and explain to the wire.
A (mm) Handle
OUTER the client until the problem is 6. All wiring must comply with local
DIAMETER (mm) Yoke solved.
Máx. Mín. and national electrical codes and be
2. Power voltage should be in the installed by qualified and skilled
6,35 1,3 0,7 Red arrow mark
range of 90%~110%of rated electricians.
9,52 1,6 1,0 voltage. 7. An individual branch circuit and
3. The creepage protector and main single receptacle used only for this
12,70 1,8 1,0
Clamp
power switch with a 1.5 times air conditioner must be available.
16 2,2 2,0 handle capacity of Max. Current of the unit See the following table for
should be installed in power circuit. suggested wire sizes and fuse
4. Ensure the air conditioner is specifications:
grounded well.
Connection Adjustment
1. Align the pipes to be connected. Caution: Excessive torque can
2. Unscrew the flare nut with your break nut depending on installation
conditions.
fingers and then with a wrench and
screw wrench, as shown in the
following figure.

Pipings
Indoor unit Flare
tubing nut

OUTER TIGHTENING ADDITIONAL TIGHTENING


DIAMETER (mm) TORQUE(cm) TORQUE(cm)

6,35 1500 (153 kgf/cm) 1600 (163 kgf/cm)


9,52 2500 (255 kgf/cm) 2600 (265 kgf/cm)
12,70 3500 (357 kgf/cm) 3600 (367 kgf/cm)
16 4500 (459 kgf/cm) 4700 (479 kgf/cm)

19 20

Downloaded from www.Manualslib.com manuals search engine


Connect the cable to the indoor unit Before performing any electrical work, turn off the main power to the system.
Electric safety regulations for the initial Electrical box 1. The inside and outside connecting cable can be connected without removing
Installation cover the front grille.
1. If there is serious safety problem about 2. The indoor power cord type is H05VV-F or H05V2V2-F, the outdoor power cord
the power supply, the technicians and interconnected cord type is H07RN-F.
should refuse to install the air 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the
conditioner and explain to the client screw.
until the problem is solved. 4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to
2. Power voltage should be in the range of the indoor respectively.
90%~110%of rated voltage. 5. Wrap those cables not connected with terminals with insulation tapes, so that
3. The surge protector and main power they will not touch any electrical components. Secure the cable onto the
switch with a 1.5 times capacity of control board with the cord clamp.
Max. Current of the unit should be
installed in power circuit. Terminal block of indoor unit
4. Ensure the air conditioner is grounded For 8K,12K and18k Btu types
well. Attention Terminal block of indoor unit
5. According to the attached Electrical
Connection Diagram located on the The cable size and the current
panel of the outdoor unit to connect of the fuse or switch are L1 L2 S
or L1 L2 S

the wire. determined by the maximum


6. All wiring must comply with local and current indicated on the
national electrical codes and be nameplate which located on
installed by qualified and skilled the side panel of the unit. Cord clamp
electricians. Please refer to the nameplate
7. An individual branch circuit and single before selecting the cable, fuse
receptacle used only for this air and switch.
conditioner must be avaliable. See the To outdoor unit To outdoor unit
following specifications:
For 24k Btu types
Terminal block of indoor unit
Rated current Nominal cross-sectional
of appliance (A) area (mm2)
L1 L2 S
>3 and ≤6 0.75
>6 and ≥10 1

>10 and ≥16 1.5


Cord clamp
>16 and ≥25 2.5

To outdoor unit

21 22

Downloaded from www.Manualslib.com manuals search engine


Connect the cable to the outdoor unit Terminal block of outdoor unit
1. Remove the electrical control board For 8k, 12k and 18k Btu models
cover from the outdoor unit by
loosening the screw. Cover Terminal block of outdoor unit
2. Connect the connective cables to the Screw
terminals as identified with their
respective matched numbers on the
L1 L2 S L1 L2 L1 L2 S L1 L2
terminal block of indoor and outdoor
units.
3. Secure the cable onto the control
board with the cord clamp.
4. To prevent the ingress of water, form a
loop of the connective cable as
illustrated in the installation diagram of
indoor and outdoor units.
To indoor unit To power supply To indoor unit To power supply
5. Insulate unused cords (conductors)
with PVC-tape. Process them so they (1) (2)
do not touch any electrical or metal
parts.

For 24k Btu models


Terminal block of outdoor unit

L1 L2 S L1 L2 L1 L2 S L1 L2

To indoor unit To power supply To indoor unit To power supply

(1) (2)

23 24

Downloaded from www.Manualslib.com manuals search engine


Caution Air purging with vacuum pump
After the confirmation of the above conditions, prepare the wiring as follows: 1. Check that each tube(both liquid and gas side tubes) between the indoor
1. Never fail to have an individual power circuit specifically for the air and outdoor units have been properly connected and all wiring for the test
conditioner. As for the method of wiring, be guided by the circuit diagram run has been completed. Remove the service valve caps from both the gas
posted on the inside of control cover. and the liquid side on the outdoor unit. Note that both the liquid and the gas
2. The screw which fasten the wiring in the casing of electrical fittings are side service valves on the outdoor unit are kept closed at this stage.
liable to come loose from vibrations to which the unit is subjected during 2. When relocate the unit to another place, perform evacuation using vacuum
the course of transportation. Check them and make sure that they are all pump.
tightly fastened. (If they are loose, it could cause burn-out of the wires.) 3. Pipe length and refrigerant amount:
3. Specification of power source.
4. Confirm that electrical capacity is sufficient.
Connective Air purging Additional amount of
5. See to that the starting voltage is maintained at more than 90 percent of the pipe length metod refrigerant to be charged
rated voltage marked on the name plate.
6. Confirm that the cable thickness is as specified in the power source Less than 5 m Use vacuum pump.
specification.
Liquid side:φ6.35mm Liquid side:φ9.52mm:
7. Always install an earth leakage circuit breaker in a wet or moist area. More than 5m Use vacuum pump.
R22: (Pipe length-5)x30g/m R22: (Pipe length-5)x60g/m
8. The following would be caused by voltage drop. Vibration of a magnetic R410A: (Pipe length-5)x20g/m R410A: (Pipe length-5)x40g/m
switch, which will damage the contact point, fuse breaking, disturbance of
the normal function of the overload.
9. The means for disconnection from a power supply shall be incorporated in
Caution in handling the packed valve
the fixed wiring and have an air gap contact separation of at least 3mm in
each active (phase) conductors. 1. Open the valve stem until it hits against the stopper. Do not try to open it
further.
2. Securely tighten the valve stem cap with a spanner or the like. Valve stem
cap tightening torque (See Tightening torque table in page 19).

Air purging
Air and moisture in the refrigerant system have undesirable effects as
indicated below: Refrigerant Flare nut

1. Pressure in the system rises. parts in the refrigeration system. Outdoor unit Indoor unit
Gas Stopper
2. Operating current rises. 6. Therefore, the indoor unit and A C
3. Cooling or heating efficiency tubing between the indoor and
D Cap
drops. outdoor unit must be leak tested
4. Moisture in the refrigerant circuit and evacuated to remove any B
may freeze and block capillary noncondensables and moisture
from the system. Packed valve Half union
tubing. Valve body
Valve stem
5. Water may lead to corrosion of

25 26

Downloaded from www.Manualslib.com manuals search engine


Electrical safety

When using the vacuum pump Perform the electric safe check after completing installation:
For method of using a manifold valve, refer to its operation manual.
1. Insulated resistance: The insulated resistance must be more than 2M .
1. Completely tighten the flare nuts, 8. Fully open the packed valve stems 2. Grounding work: After finishing grounding work, measure the grounding
A, B, C, D, connect the manifold B and A. resistance by visual detection and grounding resistance tester. Make sure the
valve charge hose to a charge port 9. Securely tighten the cap of the grounding resistance is less than 4 .
of the low-pressure valve on the packed valve. 3. Electrical leakage check (performing during test running): During test
gas pipe side. operation after finishing installation, the serviceman can use the electroprobe
2. Connect the charge hose and multimeter to perform the electrical leakage check. Turn off the unit
connection to the vacuum pump. immediately if leakage happens. Check and find out the solution ways till the
3. Fully open the handle Lo of the unit operate properly.
manifold valve.
4. Operate the vacuum pump to
evacuate. After starting Indoor unit
evacuation, slightly loose the flare
nut of the Lo valve on the gas pipe
side and check that the air is
entering (Operation noise of the Outdoor unit Gas leak check
vacuum pump changes and a
compound meter indicates 0 Soap water method indoor unit
instead of minus) Apply a soap water or a liquid neutral
check point
5. After the evacuation is complete, detergent on the indoor unit
fully close the handle Lo of the connection or outdoor unit
manifold valve and stop the connections by a soft brush to check Cover
operation of the vacuum pump. Manifold valve for leakage of the connecting points
Make evacuation for 15 minutes or Charge of th piping. If bubbles come out, the
hose
more and check that the -76cm/Hg pipes have leakage.
compound meter indicates - Outdoor unit
76cmHg (-1x10 Pa). check point
Leak detector
6. Turn the stem of the packed valve
B about 45o counterclockwise for Use the leak detector to check for
6~7 seconds after the gas coming
Handle Lo Handle Hi leakage.
out, then tighten the flare nut
Charge hose
again. Make sure the pressure Caution
display in the pressure indicator is A: Lo packed valve, B: Hi packed
a little higher than the atmosphere valve C and D are ends of indoor unit
pressure. connection.
7. Remove the charge hose from the
Low pressure charge hose. Vacuum pump

27 28

Downloaded from www.Manualslib.com manuals search engine


Operation test Preparing the device for operation

Perform test operation after completing gas leak check at the flare nut 1. Contact a specialist to install the device.
connections and electrical safety check. 2. Guarantee that the unit is appropriately fastened and complies with all of
1. Connect the power, press the cannot be controlled by the remote the aforementioned safety norms.
ON/OFF button on the remote controller to run at cooling mode, 3. Before operating the air conditioner, ensure that the air filter is installed
controller to turn the unit on. manual operation can be taken. correctly.
2. Use the MODE button to select Manual operation is used only when 4. If the unit has been out of use for a long period of time, it is recommended
COOL, HEAT, AUTO and FAN to the remote controller is disable or that the air filter be cleaned before use. During continuous use, clean the air
check if all the functions works maintenance necessary. filter every two weeks.
well. 5. This air conditioner was designed for use under the following conditions:
3. When the ambient temperature is
too low(lower than 17ºC), the unit
MODE

Cool Heat Deshumidifier

Room Temperature Room Temperature Room Temperature

Indoor Outdoor* Indoor Outdoor Indoor Outdoor**

17°C~32°C 18°C~43°C 0°C~30°C -7°C~24°C 10°C~32°C 11°C~43°C

* (-7°C~43°C cooling only / 18°C~52°C special tropical models)


** (18°C~52°C special tropical models)

Auto/Cool
or Manual control button

Attention
Optimum performance will be achieved within these operating temperatures.If air
conditioner is used outside of the above conditions, certain safety protection
features might come into operation and cause the unit to function abnormally.
Manual control
button
Room relative humidity less than 80%. If the air conditioner operates in excess of
Auto this figure, the surface of the air conditioner may attract condensation. Please
sets the vertical air flow louver to its maximum angle (vertically to the floor), and
Cool
set HIGH fan mode.

29 30

Downloaded from www.Manualslib.com manuals search engine


Product description

1 Front panel frame Display panel


2 Front panel (indoor unit)
3 Air filter 13 OPERATION
(inside front panel)
This lamp illuminates when the air
4 Horizontal airflow grille conditioner is in operation.
5 Vertical airflow grille
14 TIMER
6 Temperature sensor
(inside front panel) Lights up during Timer operation.
7 Panel 15 DEFROST indication lamp
8 Infra-red signal receiver
9 Drain hose connector and (Enabled on cooling & heating
Air inlet
models only): Lights up when the 13
refrigerant gas connector 3 2
1 air conditioner starts defrosting
10 Remote control automatically or when the warm air
11 Connector cable 4
control feature is activated in
12 Detection valve heating operation.
13 Drain hose and refrigerant
16 Temperature indicator 15 14 17 16
connecting pipe
5 Displays the temperature settings
8 when the air conditioner is
Air outlet 7
6 operational. Displays the
malfunction code.
17 Signal receiver
10 13

Air inlet

Attention 11 Attention
All the pictures in this manual are for The description in the control is based
9
explanation purpose only. They may be on a typical model. The functions are
Air outlet
slightly different from the air conditioner 12 the same in your air conditioner, even if
you purchased. there are some differences in the
Outdoor unit
appearance.

31 32

Downloaded from www.Manualslib.com manuals search engine


Remote control

Remote control operation When should the batteries be


1. Operating Mode: AUTO, COOL, DRY, replaced
HEAT(Cooling only model without), 1. Replace the batteries when there
and FAN. is no receiving beep from the
2. Timer Setting Function in 24 hours. indoor unit or if the transmission
indicator on the remote controller
3. Indoor Setting Temperature Range :
fails to light.
17。C~30。C.
2. The remote controller is powed by
4. Full function of LCD (Liquid Crystal
two dry batteries(R03/LR03X2)
Display).
housed in the rear part and
protected by a cover.
3. Remove the cover by pressing
and sliding off.
4. Remove the old batteries and
REMOTE CONTROLLER SPECIFICATIONS insert the new batteries,placing
Rated voltage 3V the(+) and (-) ends correctly.
Lowest of voltage of CPU emiting signal 2,0 V 5. Reattach the cover by sliding it
back into position.
Transmission distance 8 m*
Environment -5ºC ~ 60ºC
* (with 3 V, it reaches 11 m) Attention
Attention 1. When the batteries are removed,
the remote controller erases all
1. The air conditioner will not operate if curtains, doors or other materials block programming.
the signals from the remote controller to the indoor unit. 2. After inserting new batteries, the
2. Prevent any liquid from falling into the remote controller. Do not expose the Remote control instructions remote controller must be
remote controller to direct sunlight or heat. If the infrared signal receiver on Use the remote controller within a reprogrammed.
the indoor unit is exposed to direct sunlight, the air conditioner may not distance of 8 meters from the 3. Do not mix old and new batteries or
function properly. Use curtains to prevent the sunlight from falling on the appliance, pointing it towards the batteries of different types.
receiver. receiver. Reception is confirmed by a 4. Do not leave the batteries in the
3. If other electrical appliances react to the remote controller. Either move these beep. remote controller if they are not
appliances or consult your authorized assistance. going to be used for 2 or 3 months.
5. Do not dispose batteries as
unsorted municipal waste.
Remote control battery Collection of such waste separately
To use the remote control, it is necessary to install two (R03/Ir03x2) alkaline for special treatment is necessary.
AAA batteries.

33 34

Downloaded from www.Manualslib.com manuals search engine


Remote control description

1 ON/OFF: Operation starts when 7 TEMP: Push the + button to


this button is pressed and stops increase setting temperature or to
when this button is pressed again. increase Hour during Timer
2 MODE: Each time you push the
setting. Push - the button to
button, a mode is selected in a decrease setting temperature or
sequence that goes from AUTO, to decrease Hour during Timer
COOL*, DRY, HEAT and FAN, as the setting.
8 FAN SPEED: Used to select the
following figure indicates:
Fan Speed in four steps- AUTO,
COOL DRY HEAT* FAN
LOW, MED or HIGH. Each time
AUTO
the button is pressed, the fan
1 1
speed mode is shifted.
* Note: Only for heating and cooling 7 7
AUTO LOW MED HIGH
models.
3 SWING: Used to stop or start 2 13 2 13
horizontal louver auto swing 9 TIMER ON: Press this button to
feature. initiate the auto-on time
3 8 3 8
4 SLEEP: Active/Disable SLEEP sequence. Each press will
function. If pushing more than 2 increase the auto-timed setting in
seconds, the FRESH function will 5 9 30 minutes increments. When the 5 9
be activated, pushing more than setting time displays 10H, each
2seconds again to disable. 4 10 press will increase the auto-timed 4 10
Note: While the unit is running setting60 minutes increments. To
under SLEEP mode, it would be cancel the auto-timed program,
11 12 11 12
cancelled if press the MODE, FAN simply adjust the auto-on time to
SPEED or ON/OFF button. 0:0.
13 6 13 6
5 DIRECT: Used to change the louver 10 TIMER OFF: Press this button to
movement and set the desired initiate the auto-off time
up/down air flow direction. The sequence. Each press will
louver changes 6° in angle for each increase the auto-timed setting in
press. 30 minutes increments. When the
6 RESET: When you press the setting time displays 10H, each
recessed RESET button, all current press will increase the auto-timed
settings are cancelled and the setting 60 minutes increments. To
control will return to the initial cancel the auto-timed program,
settings. simply adjust the ON/OFF auto-
off time to 0:0

35 36

Downloaded from www.Manualslib.com manuals search engine


LCD display indicators
2
11 TURBO*: Active/Disable TURBO
1 TRANSMISSION INDICATOR: This
function. If pushing more than 2
seconds, the SELF CLEAN transmission indicator lights when
remote controller transmits signals auto cool dry heat fan
function will be activated, pushing
more than 2 seconds again to to the indoor unit.
disable(depending on
1 SET TEMP. TIMER ONOFF
models).During the heating 4
2 MODE: Displays the current
operation(only when the setting
operation mode. Including
mode is HEAT),press this button
auto ( ), cool( ), dry( ),
and the unit will operate at a
heat( ) (Not applicable to cooling
setting temperature of 8°C.The
display window of indoor unit will 1 only models), fan( ) and back to
display FP. Press the buttons of 7 auto( ). sleep follow me lock run
ON/OFF, SLEEP, FP, MODE,FAN F 3
SPEED,UP,DOWN and 3 ON/OFF: Displayed by pressing the
2 13
SHORTCUT while operating will ON/OFF button. Press the ON/OFF
cancel the FP button again to remove. 7 5 6
12 LED: Disable/Active indoor screen 3 8
Display. When pushing more than
2 seconds, the FOLLOW ME 5 4 TEMP/TIMER: Displays the
9
function will be activated, pushing temperature setting(17°C~30°C). 8 FAN SPEED: Displays the
more than 2 seconds again to When you set the operating mode selected fan speed, AUTO(no
disable. 4 10 display) and three fan speed levels
to FAN, no temperature setting is
13 LOCK: When you press the displayed. And if in the TIMER " " (LOW) " " (MED) " " (HIGH)
recessed LOCK button, all current 11 12 mode, shows the ON and OFF can be indicated. The fan speed is
settings are locked in and the settings of the TIMER. AUTO when the operating mode is
remote controller does not accept 13 6 either AUTO or DRY.
any operation except that of the
LOCK. Press again to cancel the 5 FOLLOW ME: Displayed when
LOCK mode. FOLLOW ME function is activated.
14 SHORTCUT: Used to restore the current settings or resume previous settings.
On the first time connecting to the power, if push the SHORTCUT button, the 6 LOCK: Displayed when LOCK
unit will operate on AUTO mode, 24°C, and fan speed is Auto.
mode is activated.
Push this button when remote controller is on, the system will automatically
revert back to the previous settings including operating mode, setting
temperature, fan speed level and sleep feature(if activated). And transmit the 7 SLEEP: Displayed under sleeping
signals to the unit. operation. Press the SLEEP button
If push this button when remote controller is off, the system will only resume
again to remove.
the previous settings and will not transmit the signals to the unit. And the
sleep feature is disable. If pushing more than 2 seconds, the system will
automatically restore the current operation settings including operating mode,
setting temperature, fan speed, level and sleep feature (if activated).

37 38

Downloaded from www.Manualslib.com manuals search engine


How the air conditioner works

Auto operation Dehumidifying operation


Ensure the unit is plugged in and power is available. The OPERATION indicator
Ensure the unit is plugged in and power is available. The OPERATION indicator
on the display panel of the indoor unit starts flashing.
on the display panel of the indoor unit starts flashing.
1. Press the MODE button to select Auto.
2. Press the UP/DOWN button to set the desired temperature. The temperature 1. Press the MODE button to select DRY mode.
can be set within a range of 17°C~ 30°C in 1°C increments. 2. Press the UP/DOWN buttons to set the desired temperature. The
3. Press the ON/OFFbutton to start the air conditioner. temperature can be set within a range of 17°C~ 30°C in 1°C increments.
Note: 3. Press the ON/OFF button to start the air conditioner.
1. In the Auto mode, the air conditioner can logically choose the mode of
Cooling, Fan, and Heating by sensing1the difference between the actual
In the Dehumidifying mode, you can not switch the fan speed. It has already
ambient room temperature and the setting temperature on the remote
been automatically controlled.
controller.
2. In the Auto mode, you can not switch the fan speed. It has already been
automatically controlled.
3. If the Auto mode is not comfortable for you , the desired mode can be
Adjusting air flow direction
selected manually.
Use the SWING and DIRECT button to adjust the desired airflow direction.
1. When push the DIRECT button, the horizontal louver changes 6 degree in
LED/FOLLOW ME function
angle for each push.
Press this button less than 2nds will initiate LED function. And if keep pressing
2. When push the SWING button, the louver will swing up and down
this button more than 2 seconds the FOLLOW ME function is initiated.
automatically.
When the FOLLOW ME function is activated remote display is actual
temperature at its location.
When the louver swing or move to a position which would affect the
The remote control will send this signal to the air conditioner every 3 minutes
interval until press the FOLLOW ME button again. The Follow Me function is not cooling or heating effect of the air conditioner, it would automatically
available under DRY and FAN mode. Switch the operation mode or turn off the change the swing/moving direction.
unit will cancel the Follow Me function automatically.

Cooling /Heating/Fan operation


Ensure the unit is plugged in and power is available. Turbo/self clean function
1. Press the MODE button to select COOL, HEAT(cooling & heating models Press this button less than 2nds will initiate TURBO function. And if keep
only) or FAN mode. pressing this button more than 2nds,the SELF CLEAN function is initiated.
2. Press the UP/DOWN buttons to set the desired temperature. The Turbo function enables the unit to reach the preset temperature in the shortest
temperature can be set within a range of 17°C~ 30°C in 1°C increments. time. When press this button on cooling mode, the unit will blow strong cooling
3. Press the FAN button to select the fan speed in four steps- Auto, Low, air with super high fan speed. When press this button on heating mode
Med,or High. (applicable to the unit adopts PTC only), the PTC will be energized and bring
4. Press the ON/OFF button to start the air conditioner. fast heating operation.
In the FAN mode the setting temperature is not displayed in the remote Under SELF CLEAN mode, the air conditioner will automatically clean and dry
controller and you are not able to control the room temperature either. In this the Evaporator and keep it as fresh for the next operation.
case, only step 1, 3 and 4 may be performed.

39 40

Downloaded from www.Manualslib.com manuals search engine


Timer operation between 10 and 24 hours. Timer ON (Auto-on operation)
Press the TIMER ON button can set 3. After setting the TIMER OFF The TIMER ON feature is useful when you
the auto-on time of the unit. Press the ,there will be a one second delay want the unit to turn on automatically
TIMER OFF button can set the auto- before the remote controller before you return home. The air conditioner
off time of the unit. transmits the signal to the air will automatically start operating at the set TIMER ON
To set the Auto-on time: conditioner. Then after time.
1. Press the TIMER ON button. The approximately another 2 Example:
remote controller shows TIMER ON, seconds, the signal "h" will To start the air conditioner in 6 hours.
the last Auto-on setting time and disappear and the set
the signal "h" will be shown on the temperature will re-appear on 1. Press the TIMER ON button, the last
LCD display area. Now it is ready to the LCD display window. setting of starting operation time and Start

reset the Auto-on time to START the the signal "h" will show on the display Off
operation. area.
2. Push the TIMER ON button again to 2. Press the TIMER ON button to display
Set 6 hours later
set desired Auto-on time. Each time "6:0h" on the TIMER ON display of the
you press the button, the time remote controller.
increases by half an hour between 0 3. Wait for 3 seconds and the digital display
and 10 hours and by one hour area will show the temperature again.
between 10 and 24 hours. The "TIMER ON" indicator remains on
3. After setting the TIMER ON ,there and this function is activated.
will be a one second delay before
the remote controller transmits the
signal to the air conditioner. Then,
after approximately another 2 Timer OFF (Auto-off operation)
seconds, the signal "h" will The TIMER OFF feature is useful when you
disappear and the set temperature want the unit to turn off automatically after
will re-appear on LCD window. you go to bed. The air conditioner will stop
TIMER OFF
To set Auto-off time: automatically at the set time. To stop the
1. Press the TIMER OFF button. The air conditioner in 10 hours.
remote controller shows TIMER Example:
OFF, the last Auto-off setting time Attention 1. Press the TIMER OFF button, the last
and the signal "h" will be shown on setting of stopping operation time and the
the LCD display area. Now it is The effective operation time set by signal "h" will show on the display area. Stop
ready to reset the Auto-off time to the remote controller for the timer 2. Press the TIMER OFF button to display
function is limited to the following On
stop the operation. "10h" on the TIMER OFF display of the
2. Push the TIMER OFF button again settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, remote controller. Set 10 hours later
to set desired Auto-off time. Each 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0,
3. Wait for 3 seconds and the digital
time you press the button, the time 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12,
display area will show the temperature
increases by half an hour between 0 13, 14, 15,16,17, 18, 19, 20, 21,
again. The "TIMER OFF" indicator remains
and 10 hours and by one hour 22, 23 and 24.
on and this function is activated.

41 42

Downloaded from www.Manualslib.com manuals search engine


COMBINED TIMER (Setting both ON and Sleep/Fresh functions 1. pressing the turbo or manual control
OFF timers simultaneously) TIMER ON OFF
button
TIMER OFF → TIMER ON Press this button less than 2nds will 2. unplug and then plug in the
(On → Stop → Start operation) initiate SLEEP function. And if keep machine.
This feature is useful when you want to pressing this button more than So we strongly suggest that the open
stop the air conditioner after you go to bed, 2nds,the FRESH function is initiated. angle of the horizontal louver should
and start it again in the morning when you not be set too small, in case the
wake up or when you return home. Start The sleep function enables the unit to condensed water forms and drops
Example: Stop automatically increase(cooling) or from the
On
To stop the air conditioner 2 hours after decrease(heating) 1°C per hour for the horizontal louver.
Set
setting and start it again 10 hours after 2 hours later
after setting
10 hours later
after setting
first two hours, then hold steady for the
setting. next 5 hours, after that the unit will Self-clean function (optional) -
1. Press the TIMER OFF button. stop operation. It can maintain the Function used after the shut down of
2. Press the TIMER OFF button again to most comfortable temperature and cooling operation to clean the
display 2.0h on the TIMER OFF display. save energy. Evaporator ,it keeps the air fresh for
3. Press the TIMER ON button. the next operation.
4. Press the TIMER ON button again to The SLEEP function is only available For cooling models, the unit will
display 10h on the TIMER ON display . under Cooling, Heating and AUTO operate under FAN ONLY mode
5. Wait for 3 seconds and the digital display operations. at LOW fan speed for half an hour, and
area will show the temperature again. When the FRESH function is initiated, then turn off automatically.
The "TIMER ON OFF" indicator remains the Ionizer/Plasma Dust Collector For cooling & heating models, the unit
on and this function is activated. (depending on models) is energized will operate as in the below sequence :
TIMER ON OFF
and will help to remove pollen and FAN ONLY mode at Low fan speed--
TIMER ON → TIMER OFF impurities from the air. Heating operation with LOW fan speed
(Off → Start → Stop operation) ---FAN ONLY operation--Stop
This feature is useful when you want to Special functions
Operation---Turn off.
start the air conditioner before you wake up
and stop it after you leave the house. Refrigerant Leakage Detection
Start This function is only available under
Example: With this new technology, the dipsplay
Off Stop COOL(AUTO COOL, FORCED COOL)
To start the air conditioner 2 hours after area will appear EC and the indication
and DRY mode.
setting, and stop it 5 hours after setting. lamps continue flashing when the
Before selecting the function, it is
1. Press the TIMER ON button.
Set 2 hours later outdoor unit detects refrigerant
after setting
5 hours later
recommended to run the air
2. Press the TIMER ON button again to
after setting
leakage.
conditioner under cooling operation for
display 2.0h on the TIMER ON display. Louver Angle Memory Function
about half an hour. Once the Self Clean
3. Press the TIMER OFF button. (optional): function is activated, all TIMER setting
4. Press the TIMER OFF button again to Within the scope of safety angle, it will will be cancelled.
Attention memorize the open angle of horizontal
display 5.0h on the TIMER OFF display . During SELF CLEAN operation, when
5. Wait for 3 seconds and the digital display The timer setting (TIMER ON or louver. If it exceeds, it will memorize pressing the SELF CLEAN button on
area will show the temperature again. TIMER OFF) that in sequence the boundry of safety angle. In the the remote controller again,the unit will
The "TIMER ON OFF" indicator remains occurs directly after the set time following circumstances, it will return stop the operation and turn off the unit
on and this function will be activated first. to standard angle: automatically.

43 44

Downloaded from www.Manualslib.com manuals search engine


How to use the indoor unit

Clean-air function (optional) Adjusting air flow direction


Adjust the air flow direction properly
Improving the quality of indoor air is otherwise, it might cause discomfort
one of the purposes of an air or cause uneven room temperatures.
conditioner. This air Adjust the horizontal louver using the
conditioner is equipped with ionizer or remote controller. Adjust the vertical
Plasma Dust Collector(Depending on louver manually.
specific configuration of the model).
With the anions generated by Ionizer,
the air circulation of the air conditioner Adjusting the vertical air flow
fills the room with refreshing, natural direction (up - down)
and healthy air. The Plasma Dust The air conditioner automatically
Collector generates a high voltage adjusts the vertical air flow direction in
ionization zone, through which the air accordance with the operating mode.
is converted to plasma. Inside the air
most of the dust, smoke, and pollen To set the horizontal air flow
particles are captured by the
direction (left/ right)
electrostatic filter.
Adjust the vertical louver manually
Anti-mildew function (optional using the lever on the left or right side
of the vertical louver arm (Depending
When turns off the unit on COOL, DRY, on model). Take care not to catch
AUTO (Cool) mode, the air conditioner fingers on the fan, horizontal louver or
will continue operating for about 10 to damage vertical louvers. When the
minutes (depending on models) with air conditioner is in operation and the
soft wind.This will help to dry up the horizontal louver is in a specific
condensed water inside the position, move the lever at left (or
evaporator, and prevent the breeding right, depending on model) end of the
of mildew. Under Anti-mildew air outlet to the desired position.
operation, do not restart the air
conditioner until the unit iscompletely To automatically swing the air flow
off. direction (up/down)
Perform this function while the air
conditioner is in operation.

Lever

45 46

Downloaded from www.Manualslib.com manuals search engine


Manual operation (without remote control)

Adjusting air flow direction Manual operation can be used


Adjust the air flow direction properly temporarily in case you can not find
otherwise, it might cause discomfort or the remote controller or its batteries
cause uneven room temperatures. Adjust are exhausted.
the horizontal louver using the remote 1. Open and lift the front panel up to
controller. Adjust the vertical louver an angle until it remains fixed with
manually. a clicking sound. For 24K Btu
model, please use suspension
Adjusting the vertical air flow direction bars to prop up the panel.
(up - down) 2. Once you push the manual button,
The air conditioner automatically adjusts the operation mode is shifted in an
the vertical air flow direction in order as: AUTO, COOL, OFF.(The
accordance with the operating mode. default setting temperature is 24.
3. Close the panel firmly to its
original position.
To set the horizontal air flow direction Manual control
(left/ right) button
Adjust the vertical louver manually using
Attention
the lever on the left or right side of the This is used for testing purposes only. Auto/Cool
vertical louver arm (Depending on model). To restore the remote controller
Take care not to catch fingers on the fan, operation, use the remote controller
horizontal louver or to damage vertical directly.
louvers. When the air conditioner is in
operation and the horizontal louver is in a
specific position, move the lever at left (or
right, depending on model) end of the air
outlet to the desired position.

To automatically swing the air flow


direction (up/down)
Perform this function while the air
conditioner is in operation.
Press the SWING button on the remote
controller.
To stop the function, press the SWING
button again.
Press AIR DIRECTION button to lock
louver in desired position.
The AIR DIRECTION and SWING buttons

47 48

Downloaded from www.Manualslib.com manuals search engine


Maintenance

Filtro Soporte del marco


then dry.
Cleaning the indoor unit and remote refrescante
6. Clean the support frame using a de aire
controller
vacuum cleaner or water. After, dry
for a couple of hours or until dry.
1. It is necessary to stop the air
7. Insert the fresh air filter in its original
conditioner and disconnect the Filtro
place. refrescante
power supply before cleaning.
8. Insert the high part of the air filter Fig.1 Fig.2 de aire
2. Use a dry cloth to wipe the indoor
(fresh air filter + Support frame) Soporte
unit and remote controller. del marco
again in the unit keeping in mind that
3. A cloth dampened with cold water
the outside border (right and left) are Filtro
may be used on the indoor unit if it is refrescante
lined up correctly, now place the de aire
very dirty.
whole filter in the initial position.
4. The front panel of the indoor unit can Fig.3
be removed and cleaned with water.
Soporte del marco
Then wipe it with a dry cloth.
5. Do not use a chemically treated cloth
or duster to clean the unit.
6. Do not use benzine, thinner,
polishing powder, or similar solvents
for cleaning. These may cause the Fig.4 Fig.5
plastic surface to crack or deform.

Cleaning the air filter

A clogged air filter reduces the cooling


Maintenance
efficiency of this unit. Please clean the
If you plan to idle the unit for a long time, perform the following:
filter once every 2 weeks.
1. Operate the fan for about half a day to dry the inside of the unit.
1. Lift the indoor unit panel up to an
2. Stop the air conditioner and disconnect power. Remove the batteries from
angle until it stops with a clicking
the remote controller.
sound.2. Take hold of the handle of
3. The outdoor unit requires periodic maintenance and cleaning. Do not attempt
the air filter and lift it up slightly to
to do this yourself. Contact your dealer or servicer.
take it out from the filter holder, then filtro de aire
pull it downwards.
Checks before operation
3. Remove the air filter (Fresh air filter +
1. Check that the wiring is not broken off or disconnected.
support) of the unit.
2. Check that the air filter is installed
4. Remove fresh air filter from frame
3. Check if the air outlet or inlet is blocked after the air conditioner has not been
support.
used for a long time.
5. Clean the fresh air filter at least once
a month, and replace every 4 to 5
months. Use a vacuum cleaner,
filtro de aire

49 50

Downloaded from www.Manualslib.com manuals search engine


Operation tips

The following events may occur during normal operation. A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated from building
Protection of the air conditioner. material, from furniture, or smoke.
Compressor protection The air conditioner turns to FAN only mode from COOL or HEAT (For
The compressor can't restart for 3 minutes after it stops. cooling and heating models only) mode.
Anti-cold air (Cooling and heating models only) When indoor temperature reaches the temperature setting on air conditioner, the
The unit is designed not to blow cold air on HEAT mode, when the indoor heat compressor will stop automatically, and the air conditioner turns to FAN only
exchanger is in one of the following three situations and the set temperature has mode. The compressor will start again when the indoor temperature rises on
not been reached. COOL mode or falls on HEAT mode (For cooling and heating models o ly) to the
1. When heating has just starting. set point.
2. Defrosting. Dripping water may generate on the surface of the indoor unit when cooling in a
3. Low temperature heating. high relatively humidity (relative humidity higher than 80%). Adjust the horizontal
louver to the maximum air outlet position and select HIGH fan speed.
Defrosting (Cooling and heating models only)
Heating mode (For cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor The air conditioner draws in heat from the outdoor unit and releases it via the
temperature is low and humidity is high resulting in lower heating efficiency of indoor unit during heating operation. When the outdoor temperature falls, heat
the air conditioner. During this condition air conditioner will stop heating drawn in by the air conditioner decreases accordingly. At the same time, heat
operation and start defrosting automatically. loading of the air conditioner increases due to larger difference between indoor
The time to defrost may vary from 4 to 10 minutes according to the outdoor and outdoor temperature. If a comfortable temperature can't be achieved by the
temperature and the amount of frost buildup on the outdoor unit. air conditioner, we suggest you use a supplementary heating device.
The indoor or outdoor fan stop running when defrosting (Cooling and heating Auto-restart function
models only). Power failure during operation will stop the unit completely.
A white mist coming out from the indoor unit For the unit without Auto-restart feature, when the power restores, the
A white mist may generate due to a large temperature difference between air OPERATION indicator on the indoor unit starts flashing. To restart the operation,
inlet and air outlet on COOL mode in an indoor environment that has a high push the ON/OFF button on the remote controller. For the unit with Auto-restart
relative humidity. feature, when the power restores, the unit restarts automatically with all the
A white mist may generate due to moisture generated from defrosting process previous settings preserved by the memory function.
when the air conditioner restarts in HEAT mode operation after defrosting. Lightning or a car wireless telephone operating nearby may cause the unit
Low noise of the air conditioner to malfunction.
You may hear a low hissing sound when the compressor is running or has just Disconnect the unit with power and then re-connect the unit with power again.
stopped running. Push the ON/OFF button on the remote controller to restart operation.
This sound is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has
just stopped running. This is caused by heat expansion and cold contraction of
the plastic parts in the unit when the temperature is changing.
A noise may be heard due to louver restoring to its original position when power
is first turned on.
Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not been used for a long
time or during first use of the unit.

51 52

Downloaded from www.Manualslib.com manuals search engine


Solutions for problems Technical specifications

If your air conditioner malfunctions, check the following information to find COOL MODELS
solutions or probable causes of the failure. Do not try to repair the unit by
OUTDOOR UNIT FASC09F2MBHL* FASC12F2MBHL* FASC18F2MBHL* FASC24F2MBHL*
yourself, if these solutions do not solve the failures; call your local service repair
team. INDOOR UNIT FASE09F2MBHL* FASE12F2MBHL* FASE18F2MBHL* FASE24F2MBHL*

*Color (W=White;S=Silver;M=Mirror) W W W W
Poor Equipment performance
1. The air outlet or inlet in the exterior part is obstructed. Cycle Cool Cool Cool Cool
2. The temperature in the exterior is high due to direct sunlight or another heat Cooling power (Btu/h) 9000 12000 18000 24000
source. Heating power (Btu/h) - - - -
3. Heater or a cooking stove is being used in the same room. Rated voltage (V) 220 220 220 220
4. Room is full of people.
Frequency (Hz) 60 60 60 60
5. The air filter is obstructed by dust or is dirty.
6. Inappropriate temperature adjustment. Indoor unit width (mm) 680 770 905 1030

7. Front part is obstructed. Indoor unit high (mm) 255 255 275 315
8. The capacity of the equipment is not adequate for the size of the room. Indoor unit depth (mm) 178 188 198 218
9. Air conditioner was just turn on. Indoor unit net weight (kg) 7 7,5 9 12
10.Windows or doors are open. Outdoor unit width (mm) 700 780 760 845
11.Motor protector has been activated.
Outdoor unit high (mm) 540 540 590 700
The unit does not start Outdoor unit depth (mm) 240 250 285 320
1. The plug is not connected to the outlet. Outdoor unit net weight (kg) 25 28 34,5 44,5
2. No electricity in the outlet.
3. The voltage is different.
4. Temperature is not adjusted properly.
5. burned fuse.
6. The remote control batteries need to be replaced.
7. wrong operation time.

Attention
Stop the air conditioner immediately if one of the following malfunctions occur
1. The operation indicator or other indicator flash(5 times per second) and the flashing is
not stop by disconnecting and connecting the unit.
2. Frequent change of fuses and malfunctions in the switch circuit.
3. Water spills over the equipment.
4. Remote control does not work.
5. Any other abnormal situation.

53 54

Downloaded from www.Manualslib.com manuals search engine


Notes Notes

55 56

Downloaded from www.Manualslib.com manuals search engine