S5(04-07)FM_English_R410A_130320A
MODELS:
• FAS(C,E)09F2MBHLW
• FAS(C,E)12F2MBHLW
• FAS(C,E)18F2MBHLW
• FAS(C,E)24F2MBHLW
ATTENTION
Please read this manual completely
before operating your room air conditioner.
01 02
Attention To prevent injury to the user or other people and property damage, the following
instructions must be followed.
The air conditioner that you have
bought may be slightly different Incorrect operation due to ignoring of instructions may cause harm or damage.
from the one illustrated in this The seriousness is classified by the following indications.
manual. Please refer to the
information related to the model
you have.
03 04
05 06
falling of unit.
Precautions for Installation
28.Always insert the filters securely.
Installation at the following sites may cause problems. If you must inevitably
Clean filter once every two weeks. install the unit at one of these sites, please consult your local distributor
Operation without filters may beforehand:
cause failure.
1. Site with machine oil.
29.Do not place heavy object on the
power cord and take care so that 2. Sites with a high concentration of salinity, such as coastal areas.
the cord is not compressed. There 3. Sites with sulfuric gas, such as hot water springs.
is danger of fire or electric shock. 4. Sites with high frequency equipment, such as wireless equipment, welding
30.Do not place obstacles around air- machines and medical installations.
inlets or inside of air-outlet. It may 5. Sites with flammable gases or volatile material.
cause failure of appliance or
accident. 6. Sites with special environmental conditions.
7. Laundry rooms.
07 08
1 3 2
Outdoor unit
09 10
41
45
6
More than 12cm
Air filter
2,3m or more 6
More than 60cm
41
4
45
5
B C
More than 200cm Outdoor
unit
Attention
45
11 12
43mm
holes must measure 11x20 or
11x26, with a distance of 450 mm
between each.
4. Fix the installation plate to the wall. Fastening the Indoor Unit
Wall 1. Pass the piping through the hole in Upper hook
Drilling the Hole the wall.
Indoor unit Outdoor unit
1. Determine the position of the hole 2. Put the upper claw at the back of the
for the pipe using the installation indoor unit on the upper hook of the
plate and drill the pipe hole (ø installation plate, move the indoor
65mm) so that it is titled slightly unit from side to side to see that it is
downward. securely hooked (see Fig.10 &
Fig.11). Lower hook
5-7mm
13 14
3. Piping can easily be made by lifting 1. Install the outdoor unit on a rigid
the indoor unit with a cushioning base to prevent increasing noise
material between the indoor unit level and vibration.
and the wall. Get it out after finish 2. Determine the air outlet direction
piping. where the discharged air is not
4. Push the lower part of the indoor unit blocked. In the case that the
up on the wall, then move the installation place is exposed to
indoor unit from side to side, up and Cushioning strong wind such as a seaside,
down to check if it is hooked material make sure the fan operating
securely. properly by putting the unit
lengthwise along the wall or using
a dust or shield plates.
3. Specially in windy area, install the
unit to prevent the admission of
wind. If need suspending
installation, the installation bracket
Piping and wrapping Ponding should accord with technique
1. Bundle the tubing, connecting box requirement in the installation
Indoor unit
cable, and drain hose with tape bracket diagram.
securely, evenly as shown. Cable
Pipe room 4. The installation wall should be solid Strong wind
2. Because the condensed water de conexión brick, concrete or the same
from rear of the indoor unit is intensity construction, or actions to
Connective
gathered in ponding box and is pipe reinforce, damping supporting
piped out of room. Do not put should be taken. The connection
anything else in the box. Drain hose Wrapping
belt between bracket and wall, bracket
and the air conditioner should be
firm, stable and reliable.
5. Be sure there is no obstacle which
block radiating air.
Attention
1. Connect the indoor unit first, then the outdoor unit. MODEL Width (mm) Height (mm) Depht (mm)
2. Do not allow the piping to let out from the back of the indoor unit.
9000 Btu 680 255 180
3. Be careful not to let the drain hose slack.
4. Heat insulated both of the auxiliary piping. 12000 Btu 770 255 188
5. Be sure that the drain hose is located at the lowest side of the bundle.
18000 Btu 905 275 198
Locating at the upper side can cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring. 24000 Btu 1030 315 220
7. Run the drain hose sloped downward to drain out the condensed water
smoothly.
15 16
+ =
Seal Drain joint Drain pipe
17 18
Pipings
Indoor unit Flare
tubing nut
19 20
To outdoor unit
21 22
L1 L2 S L1 L2 L1 L2 S L1 L2
(1) (2)
23 24
Air purging
Air and moisture in the refrigerant system have undesirable effects as
indicated below: Refrigerant Flare nut
1. Pressure in the system rises. parts in the refrigeration system. Outdoor unit Indoor unit
Gas Stopper
2. Operating current rises. 6. Therefore, the indoor unit and A C
3. Cooling or heating efficiency tubing between the indoor and
D Cap
drops. outdoor unit must be leak tested
4. Moisture in the refrigerant circuit and evacuated to remove any B
may freeze and block capillary noncondensables and moisture
from the system. Packed valve Half union
tubing. Valve body
Valve stem
5. Water may lead to corrosion of
25 26
When using the vacuum pump Perform the electric safe check after completing installation:
For method of using a manifold valve, refer to its operation manual.
1. Insulated resistance: The insulated resistance must be more than 2M .
1. Completely tighten the flare nuts, 8. Fully open the packed valve stems 2. Grounding work: After finishing grounding work, measure the grounding
A, B, C, D, connect the manifold B and A. resistance by visual detection and grounding resistance tester. Make sure the
valve charge hose to a charge port 9. Securely tighten the cap of the grounding resistance is less than 4 .
of the low-pressure valve on the packed valve. 3. Electrical leakage check (performing during test running): During test
gas pipe side. operation after finishing installation, the serviceman can use the electroprobe
2. Connect the charge hose and multimeter to perform the electrical leakage check. Turn off the unit
connection to the vacuum pump. immediately if leakage happens. Check and find out the solution ways till the
3. Fully open the handle Lo of the unit operate properly.
manifold valve.
4. Operate the vacuum pump to
evacuate. After starting Indoor unit
evacuation, slightly loose the flare
nut of the Lo valve on the gas pipe
side and check that the air is
entering (Operation noise of the Outdoor unit Gas leak check
vacuum pump changes and a
compound meter indicates 0 Soap water method indoor unit
instead of minus) Apply a soap water or a liquid neutral
check point
5. After the evacuation is complete, detergent on the indoor unit
fully close the handle Lo of the connection or outdoor unit
manifold valve and stop the connections by a soft brush to check Cover
operation of the vacuum pump. Manifold valve for leakage of the connecting points
Make evacuation for 15 minutes or Charge of th piping. If bubbles come out, the
hose
more and check that the -76cm/Hg pipes have leakage.
compound meter indicates - Outdoor unit
76cmHg (-1x10 Pa). check point
Leak detector
6. Turn the stem of the packed valve
B about 45o counterclockwise for Use the leak detector to check for
6~7 seconds after the gas coming
Handle Lo Handle Hi leakage.
out, then tighten the flare nut
Charge hose
again. Make sure the pressure Caution
display in the pressure indicator is A: Lo packed valve, B: Hi packed
a little higher than the atmosphere valve C and D are ends of indoor unit
pressure. connection.
7. Remove the charge hose from the
Low pressure charge hose. Vacuum pump
27 28
Perform test operation after completing gas leak check at the flare nut 1. Contact a specialist to install the device.
connections and electrical safety check. 2. Guarantee that the unit is appropriately fastened and complies with all of
1. Connect the power, press the cannot be controlled by the remote the aforementioned safety norms.
ON/OFF button on the remote controller to run at cooling mode, 3. Before operating the air conditioner, ensure that the air filter is installed
controller to turn the unit on. manual operation can be taken. correctly.
2. Use the MODE button to select Manual operation is used only when 4. If the unit has been out of use for a long period of time, it is recommended
COOL, HEAT, AUTO and FAN to the remote controller is disable or that the air filter be cleaned before use. During continuous use, clean the air
check if all the functions works maintenance necessary. filter every two weeks.
well. 5. This air conditioner was designed for use under the following conditions:
3. When the ambient temperature is
too low(lower than 17ºC), the unit
MODE
Auto/Cool
or Manual control button
Attention
Optimum performance will be achieved within these operating temperatures.If air
conditioner is used outside of the above conditions, certain safety protection
features might come into operation and cause the unit to function abnormally.
Manual control
button
Room relative humidity less than 80%. If the air conditioner operates in excess of
Auto this figure, the surface of the air conditioner may attract condensation. Please
sets the vertical air flow louver to its maximum angle (vertically to the floor), and
Cool
set HIGH fan mode.
29 30
Air inlet
Attention 11 Attention
All the pictures in this manual are for The description in the control is based
9
explanation purpose only. They may be on a typical model. The functions are
Air outlet
slightly different from the air conditioner 12 the same in your air conditioner, even if
you purchased. there are some differences in the
Outdoor unit
appearance.
31 32
33 34
35 36
37 38
39 40
reset the Auto-on time to START the the signal "h" will show on the display Off
operation. area.
2. Push the TIMER ON button again to 2. Press the TIMER ON button to display
Set 6 hours later
set desired Auto-on time. Each time "6:0h" on the TIMER ON display of the
you press the button, the time remote controller.
increases by half an hour between 0 3. Wait for 3 seconds and the digital display
and 10 hours and by one hour area will show the temperature again.
between 10 and 24 hours. The "TIMER ON" indicator remains on
3. After setting the TIMER ON ,there and this function is activated.
will be a one second delay before
the remote controller transmits the
signal to the air conditioner. Then,
after approximately another 2 Timer OFF (Auto-off operation)
seconds, the signal "h" will The TIMER OFF feature is useful when you
disappear and the set temperature want the unit to turn off automatically after
will re-appear on LCD window. you go to bed. The air conditioner will stop
TIMER OFF
To set Auto-off time: automatically at the set time. To stop the
1. Press the TIMER OFF button. The air conditioner in 10 hours.
remote controller shows TIMER Example:
OFF, the last Auto-off setting time Attention 1. Press the TIMER OFF button, the last
and the signal "h" will be shown on setting of stopping operation time and the
the LCD display area. Now it is The effective operation time set by signal "h" will show on the display area. Stop
ready to reset the Auto-off time to the remote controller for the timer 2. Press the TIMER OFF button to display
function is limited to the following On
stop the operation. "10h" on the TIMER OFF display of the
2. Push the TIMER OFF button again settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, remote controller. Set 10 hours later
to set desired Auto-off time. Each 3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0,
3. Wait for 3 seconds and the digital
time you press the button, the time 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12,
display area will show the temperature
increases by half an hour between 0 13, 14, 15,16,17, 18, 19, 20, 21,
again. The "TIMER OFF" indicator remains
and 10 hours and by one hour 22, 23 and 24.
on and this function is activated.
41 42
43 44
Lever
45 46
47 48
49 50
The following events may occur during normal operation. A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated from building
Protection of the air conditioner. material, from furniture, or smoke.
Compressor protection The air conditioner turns to FAN only mode from COOL or HEAT (For
The compressor can't restart for 3 minutes after it stops. cooling and heating models only) mode.
Anti-cold air (Cooling and heating models only) When indoor temperature reaches the temperature setting on air conditioner, the
The unit is designed not to blow cold air on HEAT mode, when the indoor heat compressor will stop automatically, and the air conditioner turns to FAN only
exchanger is in one of the following three situations and the set temperature has mode. The compressor will start again when the indoor temperature rises on
not been reached. COOL mode or falls on HEAT mode (For cooling and heating models o ly) to the
1. When heating has just starting. set point.
2. Defrosting. Dripping water may generate on the surface of the indoor unit when cooling in a
3. Low temperature heating. high relatively humidity (relative humidity higher than 80%). Adjust the horizontal
louver to the maximum air outlet position and select HIGH fan speed.
Defrosting (Cooling and heating models only)
Heating mode (For cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor The air conditioner draws in heat from the outdoor unit and releases it via the
temperature is low and humidity is high resulting in lower heating efficiency of indoor unit during heating operation. When the outdoor temperature falls, heat
the air conditioner. During this condition air conditioner will stop heating drawn in by the air conditioner decreases accordingly. At the same time, heat
operation and start defrosting automatically. loading of the air conditioner increases due to larger difference between indoor
The time to defrost may vary from 4 to 10 minutes according to the outdoor and outdoor temperature. If a comfortable temperature can't be achieved by the
temperature and the amount of frost buildup on the outdoor unit. air conditioner, we suggest you use a supplementary heating device.
The indoor or outdoor fan stop running when defrosting (Cooling and heating Auto-restart function
models only). Power failure during operation will stop the unit completely.
A white mist coming out from the indoor unit For the unit without Auto-restart feature, when the power restores, the
A white mist may generate due to a large temperature difference between air OPERATION indicator on the indoor unit starts flashing. To restart the operation,
inlet and air outlet on COOL mode in an indoor environment that has a high push the ON/OFF button on the remote controller. For the unit with Auto-restart
relative humidity. feature, when the power restores, the unit restarts automatically with all the
A white mist may generate due to moisture generated from defrosting process previous settings preserved by the memory function.
when the air conditioner restarts in HEAT mode operation after defrosting. Lightning or a car wireless telephone operating nearby may cause the unit
Low noise of the air conditioner to malfunction.
You may hear a low hissing sound when the compressor is running or has just Disconnect the unit with power and then re-connect the unit with power again.
stopped running. Push the ON/OFF button on the remote controller to restart operation.
This sound is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has
just stopped running. This is caused by heat expansion and cold contraction of
the plastic parts in the unit when the temperature is changing.
A noise may be heard due to louver restoring to its original position when power
is first turned on.
Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not been used for a long
time or during first use of the unit.
51 52
If your air conditioner malfunctions, check the following information to find COOL MODELS
solutions or probable causes of the failure. Do not try to repair the unit by
OUTDOOR UNIT FASC09F2MBHL* FASC12F2MBHL* FASC18F2MBHL* FASC24F2MBHL*
yourself, if these solutions do not solve the failures; call your local service repair
team. INDOOR UNIT FASE09F2MBHL* FASE12F2MBHL* FASE18F2MBHL* FASE24F2MBHL*
*Color (W=White;S=Silver;M=Mirror) W W W W
Poor Equipment performance
1. The air outlet or inlet in the exterior part is obstructed. Cycle Cool Cool Cool Cool
2. The temperature in the exterior is high due to direct sunlight or another heat Cooling power (Btu/h) 9000 12000 18000 24000
source. Heating power (Btu/h) - - - -
3. Heater or a cooking stove is being used in the same room. Rated voltage (V) 220 220 220 220
4. Room is full of people.
Frequency (Hz) 60 60 60 60
5. The air filter is obstructed by dust or is dirty.
6. Inappropriate temperature adjustment. Indoor unit width (mm) 680 770 905 1030
7. Front part is obstructed. Indoor unit high (mm) 255 255 275 315
8. The capacity of the equipment is not adequate for the size of the room. Indoor unit depth (mm) 178 188 198 218
9. Air conditioner was just turn on. Indoor unit net weight (kg) 7 7,5 9 12
10.Windows or doors are open. Outdoor unit width (mm) 700 780 760 845
11.Motor protector has been activated.
Outdoor unit high (mm) 540 540 590 700
The unit does not start Outdoor unit depth (mm) 240 250 285 320
1. The plug is not connected to the outlet. Outdoor unit net weight (kg) 25 28 34,5 44,5
2. No electricity in the outlet.
3. The voltage is different.
4. Temperature is not adjusted properly.
5. burned fuse.
6. The remote control batteries need to be replaced.
7. wrong operation time.
Attention
Stop the air conditioner immediately if one of the following malfunctions occur
1. The operation indicator or other indicator flash(5 times per second) and the flashing is
not stop by disconnecting and connecting the unit.
2. Frequent change of fuses and malfunctions in the switch circuit.
3. Water spills over the equipment.
4. Remote control does not work.
5. Any other abnormal situation.