You are on page 1of 8

General Model RAKC

Short-tube Rotameter®
Specifications

A conical float is guided into a cylindrical metal tube provided


with an orifice plate. The position of this float is magnetically
transmitted to the indicator.

The short-tube Rotameter is used for measurement of low flow


rates of liquids and gases. Its special application is in troubled,
opaque or aggressive mediums and under high pressure. The
instrument is mounted in a vertical pipeline with flow direction
upwards.

FEATURES
● Standard design with internal thread
● Other process connections on request
● Without valve (vertical connection)
● With valve (horizontal connection)
● Controller with valve can be fitted
● Pressure resistant (40, 100, 160 bar). Other ratings on
request.
● Optional output signal of 4-20 mA by electronic transmitter
● Intrinsically safe version
● Optional limit switch (Min., Max.)

MEASUREMENT PRINCIPLE
Float-flowmeter with sturdy magnetic indication attachment

Figure 1. Measurement principle

YOKOGAWA GS 1R1B3-E-H
4rd Edition
2

STANDARD SPECIFICATIONS
Fluid to be measured : Liquid or gas LOCAL INDICATOR (SUFFIX CODE: T70)
Measurable flow rates : Refer to “Flow table” Ambient temperature : -50 ºC to +100 ºC
Measuring range : 10:1 Option : Limit switch
Accuracy : According to VDI/VDE 3513
Class 4; for smallest range ELECTRONIC TRANSMITTER (SUFFIX CODE: E70 NOT EX;
(Cone 31), 5% of endscale value SUFFIXCODE: X70 EX-VERSION)
Indicator scale : Flow units or percent Power supply : 14-30 V DC
Process temperature Consumption : ≤ 20 mA
- Standard : -180 ºC to +150 ºC - Load resistance Ri : 0-850 Ohm
- With limit switch : -40 ºC to +150 ºC - Max. voltage : Umax = 30 V
- For electronic transmitter: -40 ºC to +150 ºC - Max. short circuit current : Imax = 30 mA
For temperatures < 0 ºC or >100 ºC, please specify the /A1 Output signal : 4-20 mA
option ('Isolation distance') The output signal is not linear with the flow, and should be
Process connection linearized externally for optimization.
- Inner thread : G 1/4"; 1/4 NPT; G 3/8"; 3/8 NPT Electrical classification : [EEx ib] IIC T6
- Cutting ring : 6 mm; 8 mm; 10 mm; 12 mm - Certificate of conformity : DEMKO 90C.98014X
- Nozzle : 6 mm; 8 mm - Internal capacity Ci : ≤ 30 nF
Materials : Medium wetted parts of 1.4571. - Internal inductivity Li : < 250 mH
Other materials on request - Temperature range : T6:-20/+40 ºC, T4:-20/+50 ºC
Housing Electrical connection : PG7
- material : Cast aluminium painted - Cable diameter : 3-6 mm
- Installation position : Vertical - Max. conductor : 1,5 mm2
- Flow direction : Upwards Connection diagram : See figures 1 and 2
- Installation length : Typically 125 mm
- Protection : IP 64 POWER SUPPLY FOR ELECTRONIC TRANSMITTER
- Color : Yellow Option code: /U2I : 220 V AC (Ex-version)
Weight : Refer to “Weight” on page 7 Option code: /U4F : 24 V (Ex-version)
Other voltages and current versions on request

G 2
+

– +
1 Output Al = 0 - 800 Ohm
F 4 - 20 mA

RAKC-E70
KC-E70

+ –
Supply voltage
14 - 30 V DC

Figure 1. Transmitter -E70424 without power supply (not intrinsically safe)

Output 4 - 20 mA
Pl = 0 - 375 Ohm

PA 18 17
PA Terminal 17
G 2 2 is at PA-
+ IN+ potential

NG 24 EX2-
– IN- (EEx ib) IIC
1 1 ~
F +,
~ –,
RAKC-X70
KC-X70 N 10 11 L1
Supply voltage
220 V AC TYP NG24EX2-220AC
110 V AC TYP NG24EX2-110AC
24 V DC TYP NG24EX2-024DC

Ex - area non EX - area

Figure 2. Transmitter -X70424 with power supply (intrinsically safe)

GS 1R1B3-E-H
3

TECHNICAL SPECIFICATION OF THE OPTIONS

LIMIT SWITCHES (OPTION CODE: /K1.../K3) CONTROLLER (OPTION CODE: /R1.../R4)


Type : Inductive switch SJ 3,5-N Differential pressure controller for a constant flow at fluctuations
acc. DIN 19234 (NAMUR) of the process pressure.
Ambient temperature : -25 ºC to +100 ºC - Controller /R1 and /R2 for liquids with variable inlet or outlet
Nominal voltage : 8 V DC (Ri≈1 kΩ) pressure and for gases with variable inlet pressure and constant
Supply voltage range : 16 V back pressure.
Output signal : ≤ 1 mA=0; ≥ 3 mA=1 - Controller /R3 and /R4 for gases with fluctuations of the back
pressure.
LIMIT SWITCHES IN FAIL SAFE VERSION Max. liquid flow : 100 l/h
(OPTION CODE: /KS) Max. gas flow : 3000 l/h
Type : Inductive switch SJ 3,5-SN Max. pressure : 40 bar
acc. DIN 19234 (NAMUR) in Recommended differential pressure
FAIL SAFE version : > 400 mbar
Ambient temperature : -40 ºC to +100 ºC Materials
Other specifications : See type SJ 3,5-N Housing Diaphragm Springs
Available with options /K1.../K3 only
CrNi-steel PTFE CrNi-steel
POWER SUPPLY FOR LIMIT SWITCHES
(OPTION CODE: /WXX) Brass Buna CrNi-steel
Type : Transistor relay acc. DIN 19234
(NAMUR) Control characteristics : See diagram
Power supply : 230 V AC + 10%/-15%, The curves V1 to V6 indicate how
50/60 Hz (/W2A,/W2B) the flow depends on the inlet
24 V DC ± 20% (/W4A,/W4B) pressure for different valve set-
Relay output : 1 potential-free changeover con- tings. The back pressure at the
tact (/W2A, /W4A) outlet (ambient pressure) is 1 bar.
2 potential-free changeover con-
tacts (/W2B, /W4B)
Switching capacity : Max. 250 V AC; max. 2 A
Control circuit : Intrinsically safe [EEx ia] IIC
Entity parameters : acc. certificate of conformity
PTB Nr. Ex-94.C2086

l/h air at 20 ºC, 1.013 bar abs.

Inlet pressure

Figure 3. RAKC with limit switches and power supply Figure 4. Diagram control characteristics

GS 1R1B3-E-H
4

MODEL SPECIFICATIONS
Model Suffix code Description

RAKC53 Connecting diameter 6 mm for process connection only


RAKC54 Connecting diameter 8 mm } C4; C6; C7; P1
RAKC55 Connecting diameter 10 mm for process connection only
RAKC56 Connecting diameterr 12 mm } C4; C6; C7
RAKC41 Connecting diameter 1/4 inch for process connection only
RAKC42 Connecting diameter 3/8 inch } R4; G4; G6; T4; T6; T7

Process -R4 Internal thread Rp PN40


connection -G4
-T4
-G6
-T6
-T7
-C4
Internal thread G PN40
Internal thread NPT PN40
Internal thread G PN100
Internal thread NPT PN100
Internal thread NPT PN160
Cutting ring PN40
} for models
RAKC41
RAKC42 only

for models
-C6
-C7
Cutting ring PN100
Cutting ring PN160
} RAKC53, RAKC54,
RAKC55 and RAKC56
-P1 Nozzle PN10 RAKC53 and RAKC54 only

Material wetted SS 1.4571 ,(AISI 316 Ti)


parts

Cone -kk See “Flow table”

Valve NNN Without valve (not with optional controller)


Gasket Valve socket
SAE With insertion valve in input 1) Buna Silver
SBE With insertion valve in input 1) Viton Silver
SAA With insertion valve in output 1) Buna Silver
SBA With insertion valve in output 1) Viton Silver

Indicator/transmitter -T Local indicator


-E Electronic transmitter (not Ex)
-X Electronic transmitter (Ex)

Housing type 70 Aluminium

Power supply, output NNN Use for local indicator/T


424 24 V DC (2-wire, 4-20 mA)

Style code *A Style

Options /k See “Options”

1)
Valve can only be used until PN16.

The contents of the selection table should be noted for Ordering instructions:
determining the model code.
Standard
Recommended 1. Model, suffix and option code
Please specify in the following order 2. Flow conditions
- controller/without controller a. Temperature
- valve/without valve b. Pressure
- connecting diameter RAKC and process connection c. Viscosity
- flow range d. Density
- model, suffix and option code. For gases : cross-reference of the scale
Option /BG : customer specification notes

GS 1R1B3-E-H
5

OPTIONS
Options Option code Description

Isolation distance /A1 Indicator with isolation distance for t > 100 ºC or t < 0 ºC

Mark /B1 Stainless steel tag plate


/BG Tag number. Please specify.

Tests/Certificates /H1 Certificate of degrease


/P2 Certificate of compliance with the order (acc. to DIN 50049, 2.1)
/P3 Test report (acc. to DIN 50049, 2.2)
/P6 Inspection certificate (acc. to DIN 50049, 3.1b: pressurised parts)
/PP Inspection certificate for pressurised air

Limit switch /K1 MIN contact


/K2 MAX contact
/K3 MIN-MAX contact, MIN-MIN-contact, MAX-MAX-contact For T-indicator only
/KS FAIL-SAFE version, MIN-contact
/K7 FAIL-SAFE version, MAX-contact
/K8 FAIL-SAFE version, MIN-MAX-contact
/K9 FAIL-SAFE version, MIN-MIN-contact
/K10 FAIL-SAFE version, MAX-MAX-contact
Limit switch in FAIL-SAFE version (-40°C to + 100 °C),
only in combination with options /K1 ... /K3

Controller /R1 Inlet controller (of 1.4571) with valve in the input For gases with variable
/R2 Inlet controller of brass with valve in the input inlet pressure and liquids
with variable inlet and
back pressure
/R3 Back pressure controller (of 1.4571) with valve in the output For gases with variable
/R4 Back pressure controller of brass with valve in the output back pressure

Additional /U2I Power supply 220 V AC; 4-20 mA; 24 V Ex


Instruments /U4F Power supply 24 V DC; 4-20 mA; 24 V Ex
/W2A Transistor relay KFA6-SR2-Ex1.W/230 V AC; 1 channel, changeover contact
/W2B Transistor relay KFA6-SR2-Ex2.W/230 V AC; 2 channels, changeover contacts
/W4A Transistor relay KFD2-SR2-Ex1.W/24 V DC; 1 channel, changeover contact
/W4B Transistor relay KFD2-SR2-Ex2.W/24 V DC; 2 channels, changeover contacts

Options can be added to the model code.

GS 1R1B3-E-H
6

FLOW TABLE
Recommended
combinations Water/Liquids Air/Gases*
20°C 20°C,1 bar absolut

Optional Design R Process connection Max. Cone Pressure Max. Cone Pressure
controller (valve) A Flow drop Flow drop
K
C [l/h] code [mbar] [I/h] code [mbar]

1 31 28 45 31 39
2,5 33 29 100 33 41
53 -C4/-C6/-C7/-P1 4 34 29 160 34 41
54 -C4/-C6/-C7/-P1 6 37 27 230 37 38
without NNN 55 -C4/-C6/-C7 10 41 27 370 41 38
56 -C4/-C6/-C7 16 42 28 570 42 39
41 -G4/-G6/-T4/-T6/-T7 25 43 28 850 43 39
40 44 27 1500 44 38
60 47 28 2100 47 39
100 51 29 3300 51 41

53 -C4/-C6/-C7/-P1
54 -C4/-C6/-C7/-P1
without NNN 55 -C4/-C6/-C7 160 52 29 5200 52 41
56 -C4/-C6/-C7 250 53 34 8000 53 48
42 -G4/-G6/-T4/-T6/-T7

1 31 28 45 31 39
SAE 2,5 33 29 100 33 41
4 34 29 160 34 41
SBE 53 -C4/-P1 6 37 27 230 37 38
without 54 -C4/-P1 10 41 27 370 41 38
SAA 55 -C4 16 42 28 570 42 39
56 -C4 25 43 28 850 43 39
SBA 41 -R4/-T4 40 44 27 1500 44 38
60 47 28 2100 47 39
100 51 29 3300 51 41
160 52 29 5500 52 41
250 53 34 8000 53 48

1 31 28 45 31 39
R1, R2 SAE 2,5 33 29 100 33 41
4 34 29 160 34 41
SBE 53 -C4/-P1 6 37 27 230 37 38
54 -C4/-P1 10 41 27 370 41 38
41 -R4 16 42 28 570 42 39
R3, R2 SAA 25 43 28 850 43 39
40 44 27 1500 44 38
SBA 60 47 28 2100 47 39
100 51 29 3300 51 41

Higher measuring ranges with process connection 1/2" (old design KCl 400-1000) on request.

• Valve model is advised

GS 1R1B3-E-H
7

DIMENSIONS

158
Cutting ring Cutting ring

Figure 5. Version NNN (without valve) Figure 6. Version SAE and SBE Figure 7. Version SAA and SBA
(with valve in input) (with valve in output)

Cutting ring
Cutting ring
168

Figure 8. Versions SAE and SBE with option /R1 or /R2 Figure 9. Versions SAA and SBA with option /R3 or /R4
(with valve in input and with inlet controller) (with valve in output and back pressure controller)

WEIGHT
Weight
Measuring range Dimension “a” Without valve With valve With control

max. 100 l/h water G1/4” or 1/4 NPT ca. ca. ca. 1800 g
160 + 250 l/h water G3/8” or 3/8 NPT 600 g 1000 g -

GS 1R1B3-E-H
GERMANY AUSTRALIA UNITED STATES OF AMERICA
YOKOGAWA Yokogawa Deutschland GmbH
Berliner Strasse 101-103
D-40880 RATINGEN
Yokogawa Australia Pty Ltd.
Private mail bag 24
Centre Court D3
Yokogawa Industrial Automation
4 Dart Road
NEWNAN, GA 30265-1040
Tel. +49-2102-4983 0 25-27 Paul Street North Tel. +1-770-254 0400
AUSTRIA Fax +49-2102-4983 22 NORTH RYDE, N.S.W. 2113 Fax +1-770-251 6427
EUROPEAN HEADQUARTERS Tel. +61-2-805 0699
Yokogawa Europe B.V. Yokogawa Austria Ges.m.b.H. ISO 9001
Franzensbrückenstrasse 26 ITALY Fax +61-2-888 1844
Vanadiumweg 11, Yokogawa Italia S.r.l.
3812 PX AMERSFOORT A-1021 WIEN
Tel. +43-1-216 50 43 Vicolo D. Pantaleoni, 4 SINGAPORE
The Netherlands 20161 MILANO Yokogawa Engineering Asia Pte. Ltd.
Tel. +31-33-4641 611 Fax +43-1-216 50 43 33
Tel. +39-2-66 24 11 11, Tampines Street 92
Fax +31-33-4641 610 Fax +39-2-645 57 02 SINGAPORE, 528872
BELGIUM CERTIFICATED
E-mail: info@yokogawa.nl Tel. +65-783 9537 FIRM
Yokogawa Belgium N.V./S.A.
Minervastraat 16 SPAIN Fax +65-786 2606
THE NETHERLANDS Yokogawa España S.A.
Yokogawa Nederland B.V. 1930 ZAVENTEM
Tel. +32-2-719 55 11 C/Francisco Remiro, N°2, Edif. H Manufactured by:
Computerweg 1, 28028 MADRID GERMANY
3606 AV MAARSSEN Fax +32-2-725 34 99 CENTRAL/EAST REGION
Tel. +34-1-724 20 80 Rota Yokogawa GmbH & Co. KG
Tel. +31-346-59 12 11 Fax +34-1-355 31 40 Rheinstrasse 8 Via Yokogawa Austria: Czechia,
Fax +31-346-56 61 96 FRANCE Slovakia, Hungary, Poland,
Yokogawa Contrôle Bailey S.A. D-79664 WEHR
UNITED KINGDOM Tel. +49-7761-567 0 Croatia, Slovenia, Jugoslavia,
Vélizy Valley Bulgaria, Romania, Macedonia,
18-20 Rue Grange Dame Rose Yokogawa United Kingdom Ltd. Fax +49-7761-567 126
Stuart Road, Manor Park, Bosnia & Herzegovina
78140 VELIZY VILLACOUBLAY
Tel. +33-1-39 26 10 00 RUNCORN SOUTH AFRICA
Cheshire WA7 1TR Yokogawa South Africa (Pty) ltd. Distributors in:
Fax +33-1-39 26 10 30 Denmark, Finland, Greece,
Tel. +44-1-928 597100 67 Port Road, Robertsham
Fax +44-1-928 597101 Southdale 2135, JOHANNESBURG Norway, Portugal, Russian
Tel. +27-11-680-5420 Federation, Sweden,
Fax +27-11-680-2922 Switzerland and Turkey.

Block 03,01-98

GS 1R1B3-E-H
Subject to change without notice Printed in The Netherlands, 04-802 (A) Q