You are on page 1of 3

Dead Loads:

For Exterior Walls:


𝐾𝑁
𝑊𝑤𝑎𝑙𝑙 = 1.2(3.1)(3) = 11.16
𝑚
For Beams:
𝐾𝑁
𝑊 = 1.2(23.6)(0.3)(0.4) = 3.3984
𝑚

For Slabs:
We used the formula
W = 𝛾𝑐𝑜𝑛𝑐 𝑡
Where 𝛾𝑐𝑜𝑛𝑐 the specific weight of the concrete and t is is is the thickness of the slab.

For Floor Finishes:


We used the ceramic tile (30mm) on 13mm mortar bed
𝑊 = 0.72 𝐾𝑃𝑎
𝑾 = 𝑭𝒍𝒐𝒐𝒓 𝑭𝒊𝒏𝒊𝒔𝒉 + 𝑪𝒆𝒊𝒍𝒊𝒏𝒈 𝑭𝒊𝒏𝒊𝒔𝒉 + 𝑺𝒍𝒂𝒃 + 𝑷𝒂𝒓𝒕𝒊𝒕𝒊𝒐𝒏 𝑾𝒂𝒍𝒍

𝑊1 = 1.2 (0.77 + 0.24 + 0.58) = 7.322 𝑘𝑃𝑎


𝑊2 = 1.2 (0.77 + 0.24 + 4.72 + 0.07 + 0.38) = 7.416 𝑘𝑃𝑎
𝑊3 = 1.2(0.77 + 0.24 + 4.72 + 0.07 + 0.38) = 7.416 𝑘𝑃𝑎

Area Tributary
4.5 2
7.322(4.5) 3 − ( 5 ) 𝐾𝑁
𝑊𝑎 = [ ] = 12.04
3 2 𝑚

7.332(4.5) 𝐾𝑁
𝑊𝑏 = = 10.998
2 𝑚
𝐾𝑁
𝑊𝑐 = 10.998
𝑚
4.5 2
7.416(4.5) 3 − ( 5 ) 𝐾𝑁
𝑊𝑑 = [ ] = 12.18
3 2 𝑚
4.5 2
7.416(4) 3 − ( 5 ) 𝐾𝑁
𝑊𝑒 = [ ] = 11.67
3 2 𝑚

7.416(4) 𝐾𝑁
𝑊𝑓 = = 9.888
3 𝑚
7.332(4) 𝐾𝑁
𝑊𝑔 = = 9.776
3 𝑚
4.5 2
7.416(4) 3 − ( 5 ) 𝐾𝑁
𝑊ℎ = [ ] = 11.67
3 2 𝑚

Figure
I. LIVE LOADS

Live Loads in Each Slab:

The live loads for each slab is from (NSCP 2015, Chapter 2-11, Table 205, Minimum
Uniform and Concentrated Live Loads)

𝐾𝑁
Slab 1, 𝑊𝐿𝐼𝑉𝐸 = 1.9 𝑚2
𝐾𝑁
Slab 2, 𝑊𝐿𝐼𝑉𝐸 = 1.9 𝑚2