You are on page 1of 4

No.

SS2-DEO412-0010
(Edi. 2)

Harmonized Automation System -


Dependable Open

Introduction
The Harmonas-DEO™ system is a next-generation automa- anywhere in the system through open networks. With this
tion system that uses open and standard technology bases feature, all personnel, ranging from operators in the field to
like Windows OS for information management, and Eth- upper management, can track the operational status of the
ernet connections for control and information networking system in real time.
functions, in order to significantly improve the flexibility of
information sharing environments. As a field network, the 2. Dependable
system complies with the industry standard Fieldbus Foun-
dation specifications. Total reliability supports plant control environments.
Regarding information sharing, DCOM, ActiveX, and OPC In order to assure the level of process control reliability
are used for the control software data interface to further im- required for customers’ applications, while using an open
prove coordination with general-purpose software products. and general purpose infrastructure, the Harmonas-DEO
The new “Dependable Open” concept assures the level of automation system uses technology bases that are focused
high reliability that is generally required for process control on the concept of dependability. In addition to the basic
applications, with the advantages of open and standardized reliability mechanisms, such as Ethernet redundancy and
technology bases. nodes redundancy and failover functions of nodes, a high
level of stability in overall automation system operation has
Features been achieved with the Harmonas-DEO system, improving
maintainability, operation integrity assurance, and security
1. Open Modular Architecture & Information on Demand at the same time.
The open and distributed functional structure
implements Plug and Play solutions in the area of 3. Automation Suite
industrial automation systems. Moreover, data is Solutions necessary for plant automation are provided.
accessible from any location in the system. Solutions necessary for plant automation are provided.
The Harmonas-DEO architecture combines a wide variety Harmonas-DEO can provide a wide range of software solu-
of applications, from field-level system components to tions that are necessary for constructing a plant automation
production control systems, in an organized structure with system. “Automation Suites” is the generic name for a group
open networks forming the core of the system. Any data of solutions that can be implemented by the Harmonas-DEO
integrated into a Harmonas-DEO system is accessible from system.

Client PC Web Client Host System

Information Network
(Ethernet)

Thin Client Supervisory Station Supervisory Station Supervisory Station History Gateway
Supervisory Server (DOSS_H) (DOSS) (DOSS_H) Station Station
(TSS) (DOHS) (DOGS)

Control Network (Ethernet)


General Harmonas-FLeX™
PLC Linker II S Purpose Distributed
Process Fieldbus
(DOPL II S) Linker II Controller
Controller IV Controller
(DGPL II) (FLC)
(DOPC IV) (DOFC)

MELSECNET NX
I/O Fieldbus Link Module
(FBLM)
PLC
H1 Fieldbus
I/O

QCS
MELSEC MELSEC
I/O

Fieldbus Devices

Figure 1. Sample System Configuration

1
No. SS2-DEO412-0010 Azbil Corporation

System Configuration
Harmonas-DEO system is comprised of human-machine ■■ Fieldbus Controller (DOFC)
interface (HMI) nodes to be used for system monitoring DOFC communicates with FOUNDATION fieldbus devices to
and control operations, highly reliable process controller display process data and parameters of Function Blocks in
nodes that can be arranged in a redundant configuration, the field devices on operation displays of DOSS Supervisory
and redundant control LAN (Ethernet) systems to connect Stations and DOHS History Stations.
all the nodes. Windows OS is used for all HMIs as the basic
operating system to provide the users with a comfortable ■■ General Purpose Linker (DGPL II)
monitoring and control operation environment as well as to DGPL II is a multi-functional controller to be used for
provide an open data processing environment. integrating and controlling MULTI kinds of devices through
Furthermore, in order to establish a control system that OPC Interface. By using DGPL II, devices are handled as
is suited for the purpose of the system, various types of I/O devices for enabling loop control, logic control, and
application modules, including field operation modules, sequence control functions, as well as the operations with
remote monitoring modules, history analysis modules, batch DOPC IV. The control database of DGPL II is constructed in
process control modules, communication gateway modules, common with DOPC IV.
transient operation support modules, and alarm analysis
modules are available. ■■ PLC Linker (DOPL™ II/DOPL II S)
DOPL II/DOPL II S are a multi-functional and redundantly
System Component Equipment configurable controller to be used for integrating and
■■ Supervisory Station (DOSS, DOSS_H) controlling Mitsubishi MELSEC devices through MELSEC-
DOSS provides system construction (engineering) functions NET/10 (or MELSECNET/ H) networks. By using DOPL
as well as HMI functions for process control and monitor- II/DOPL II S, all link devices of MELSECNET are handled
ing operations. DOSS_H is implemented with the process as I/O devices for enabling loop control, logic control, and
history database (MSSQL server) functions in addition to sequence control functions, as well as the operations with
the basic HMI functions of DOSS. Either a general-purpose DOPC IV. The control database of DOPL II/DOPL II S are
desktop CPU type or a console type (single-stage or dual- constructed in common with DOPC IV.
stage) configuration is selectable for these nodes. ■■ Thin Client Supervisory Server (TSS)
■■ History Station (DOHS™) TSS server nodes provide client PCs installed in remote
DOHS is implemented with a process history data server fields and offices with a DCS operations environment.
(MSSQL server) and is dedicated to history data collection DOSS-like control operations can be made from client PCs.
functions. Display applications of TSS are constructed in common with
DOSS.
■■ Process Controller IV (DOPC™ IV)
■■ Gateway Station (DOGS)
DOPC IV is multi-functional process controller that can be
used for implementing process input/output control, loop DOGS general-purpose communications gateway connects
control, logic control, and sequence control functions. High the Harmonas-DEO system to information system networks
density and redundantly configurable process I/O modules for enabling data communication with host computers.
are connected to DOPC IV. DOGS uses OPC, a general-purpose protocol, as the com-
munications protocol to function as an OPC server.

System Specification
Table 1. Summary Specifications for the Harmonas-DEO System
Item Specification
Number of nodes Total nodes per system * 126 nodes
Graphic tag 60,000 tags per SS node
Number of control tags
Controller tag 100,000 tags per system
Control bus l0 Mbps/l00 Mbps Ethernet, up to 2.5 km (2 km for 100 Mbps)
Network Data Control System LAN 10 Mbps/100 Mbps/1 Gbps Ethernet
Field network FOUNDATION Fieldbus H1 Fieldbus
Redundant control bus (Ethernet) Standard
Redundancy functions Redundant controller DOPC IV, DOPC III, DOFC, DOPL II, DOPL II S
Non-redundant controller DOPC IV, DOPC III, DOFC, DOPL II, DOPL II S, DGPL II, FLC
Number of history points Up to 6400 points
History capacity
History period 1, 5, 10, or 30 seconds, 1, 2, 5, or 10 minutes
* Total nodes, including DOSS, DOSS_H, TSS, DOHS, DOGS, DOPC IV, DOPC III, DOFC, DOPL II, DOPL II S, and FLC.

2
Azbil Corporation No. SS2-DEO412-0010

Sample System Configuration

Supervisory Station Supervisory Station History Supervisory


(DOSS) (DOSS) Station (DOSS_H)

Control LAN

Control LAN
Controller
DOPC IV/DOFC/DOPL II/DOPL II S Controller Controller
DGPL II/FLC

Figure 2. H
 armonas-DEO Minimum Configuration Figure 3. H
 armonas-DEO Multiple Node Configuration
(example) (example)

Office Operation Environment


Host System
Office PC Office PC
Office PC

Ethernet

Information System Network


Supervisory History Supervisory
Station (DOSS) Station (DOSS_H)
History Supervisory Gateway
Station (DOSS_H) Station
(DOGS)
Thin Client
Supervisory Server
(TSS)

Control LAN

Control LAN Controller Controller

Controller Controller

Figure 4. Office Operation Configuration (example) Figure 5. H


 ost System Connection Configuration
(example)

PREXION clients

Information System Network

Supervisory Station Supervisory Station


(DOSS) (DOSS)
History
Station
(DOHS)

Control LAN

Controller Controller

Figure 6. Example Process Data Analysis System (PREXION™ clients)

3
• Harmonas-DEO, Harmonas-FLeX, PREXION, DOHS, DOPC, and DOPL are trademarks of Azbil Corporation in Japan.
• FOUNDATION is a trademark of Fieldbus FOUNDATION.
• Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
• Ethernet is a registered trademark of XEROX Corporation.
• MELSEC and MELSECNET/10 are a trademarks of Mitsubishi Electric Corporation, Ltd.
• Other product names, model nos., and company names may be trademarks of the respective company.

Please, read ‘Terms and Conditions’ from following URL before


the order and use.
http://www.azbil.com/products/factory/order.html
Specifications are subject to change without notice.

1-12-2 Kawana, Fujisawa


Kanagawa 251-8522 Japan
URL: http://www.azbil.com/ 1st edition: Nov. 2014
2nd edition: Apr. 2016
No part of this publication may be reproduced or duplicated
4 without the prior written permission of Azbil Corporation.
(12)