You are on page 1of 4

N N EL

IL TU
R A
G Q
ST IN
E X I

2
1

-
E
GAT
N
ECTIO
N N
CO

2
1-
NOTE:
TYPICAL WATER PROOFING SYSTEM TO ADOPT
EXISTING Q-RAIL DETAILS. PLEASE REFER TO
LIFT FOUNDATION G.A AND SECTION DETAILS
(CONNECTING TO Q-RAIL TUNNEL)
PH13-5C-95-72-8002 , REV-3

DESIGN SUB-CONTRACTOR NAME: CONTRACTOR NAME:

NEL
TUN
QATARI ENGINEER & ASSOCIATES
Grade - A. Arch'l, Struct'l & MEP Consultant
UPDA Reg.No.06

E P.O.Box : 3529 Doha - Qatar Tel: +974 44417477 / 78 / 81


Fax: +974 44419567. E-mail : qea@qatar.net.qa
Web: www.qeadoha.com
SIEMENS CONSORTIUM
SIEMENS AG - SIEMENS WLL

QEA/926/S
132/11kV AL SADD 3 SUBSTATION
CONNECTION DETAILS FOR PROPOSED
PART PLAN AND EXISTING TUNNEL WALL 29.03.2018
SHT.1 OF 4
6000
4
1000 4000 SHT-4 1000
EL-1.700 SSL (9.40 QND) EXISTING REBARS

EXISTING Q-RAIL EXISTING Q-RAIL


1000

1000
RC WALL RC WALL
60∅ 60∅

T16-250 BARS EXISTING Q-RAIL T16-250 BARS


RC WALL

40∅

40∅
WALL CONNECTING EXISTING REBARS
TO TUNNEL TO BE MAINTAIN

(MIN)
100
EXISTING REBARS EXISTING REBARS
40∅ 40∅
EXISTING BARS T16-150 EXISTING BARS
CUT AND TO BE BEND 7T25
BARS 4 CUT AND TO BE BEND

T25-150

T16-150 EF
T25-150
3 T16-150 EF
3

2500
SHT-3 SHT-3

T16-250 BARS T16-250 BARS


40∅

40∅
TRAIN ACCESS
TUNNEL FLOOR LVL.
2.710 QND
325 (min)

325 (min)
115 115

DESIGN SUB-CONTRACTOR NAME: CONTRACTOR NAME:

NOTE:
SECTION 1-1 QATARI ENGINEER & ASSOCIATES
Grade - A. Arch'l, Struct'l & MEP Consultant
UPDA Reg.No.06
P.O.Box : 3529 Doha - Qatar Tel: +974 44417477 / 78 / 81 SIEMENS CONSORTIUM
TYPICAL WATER PROOFING SYSTEM TO ADOPT SCALE 1:25 Fax: +974 44419567. E-mail : qea@qatar.net.qa SIEMENS AG - SIEMENS WLL
Web: www.qeadoha.com
EXISTING Q-RAIL DETAILS. PLEASE REFER TO
LIFT FOUNDATION G.A AND SECTION DETAILS QEA/926/S
(CONNECTING TO Q-RAIL TUNNEL) 132/11kV AL SADD 3 SUBSTATION
PH13-5C-95-72-8002 , REV-3
CONNECTION DETAILS FOR PROPOSED
AND EXISTING TUNNEL WALL 29.03.2018
SHT.2 OF 4
6000

1000 4000 1000

∅16 BARS

∅16 BARS
EXISTING Q-RAIL EXISTING Q-RAIL
1000

1000

1000

1000
RC WALL RC WALL
DOOR OPENING

EXISTING REBARS EXISTING REBARS


CONCRETE PART WILL CONCRETE PART WILL
T16-150 EF BE DEMOLISHED, EXISTING REINF. BE DEMOLISHED,EXISTING REINF. T16-150 EF
∅25 BARS

∅25 BARS
SHALL BE BEND TO THE SHALL BE BEND TO THE
∅25 BARS

∅25 BARS
T25-150 EF PROPOSED WALL AS SHOWN PROPOSED WALL AS SHOWN T25-150 EF

WALL CONNECTING WALL CONNECTING


TO TUNNEL TO TUNNEL

SECTIONAL PLAN VIEW


NOTE:
TYPICAL WATER PROOFING SYSTEM TO ADOPT
EXISTING Q-RAIL DETAILS. PLEASE REFER TO
LIFT FOUNDATION G.A AND SECTION DETAILS
SECTION 3-3
SCALE 1:25
(CONNECTING TO Q-RAIL TUNNEL)
PH13-5C-95-72-8002 , REV-3

DESIGN SUB-CONTRACTOR NAME: CONTRACTOR NAME:

QATARI ENGINEER & ASSOCIATES


Grade - A. Arch'l, Struct'l & MEP Consultant
UPDA Reg.No.06
P.O.Box : 3529 Doha - Qatar Tel: +974 44417477 / 78 / 81 SIEMENS CONSORTIUM
Fax: +974 44419567. E-mail : qea@qatar.net.qa SIEMENS AG - SIEMENS WLL
Web: www.qeadoha.com

QEA/926/S
132/11kV AL SADD 3 SUBSTATION
CONNECTION DETAILS FOR PROPOSED
AND EXISTING TUNNEL WALL 29.03.2018
SHT.3 OF 4
T25-150 DOWEL BARS WITH
APPROVED ADHESIVE ANCHORING SOIL AREA
SYSTEM TO EXISTING CONCRETE 1000
T25-150 T2 1000
325 (min) 1500 T25-150 T1
EL-1.700 SSL (9.40 QND)

115

//

TUNNEL TOP SLAB


EXISTING Q-RAIL T16-150 EF

1000
TUNNEL TOP SLAB
1000

1000
//
WALL T25-150 EF

1500

0
30
//

30 (EJ)
115
EXISTING BARS
T25-150 B1
T25-150 B2 125 EXISTING Q-RAIL
(MIN) RC WALL
NOTE:

300
30
0
325 (min)
EXISTING CONCRETE SURFACE TO BE ROUGHEN & APPLY
APPROVED STRUCTURAL BONDING AGENT ON ALL CONTACT
SURFACE BETWEEN NEW & EXISTING CONCRETE (TYP). WALL
T16-150 BARS
WATER PROOFING SYSTEM TO ADOPT EXISTING Q-RAIL T16-150 EF
EXISTING HORIZONTAL
DETAILS. BAR TO BE RETAIN

(MIN)
100
T25-150 EF
7T25
600 (MIN)

DOOR
OPENING
TYPICAL R.C DETAILS FOR
VERTICAL WALL EXPANSION JOINT
(PLAN VIEW)
SCALE -N.T.S

SECTION 4-4
SCALE -N.T.S

NOTE:
T25-150 B2 TRAIN ACCESS TYPICAL WATER PROOFING SYSTEM TO ADOPT
T25-150 B1 TUNNEL FLOOR LVL. EXISTING Q-RAIL DETAILS. PLEASE REFER TO
2.710 QND
LIFT FOUNDATION G.A AND SECTION DETAILS
(CONNECTING TO Q-RAIL TUNNEL)
PH13-5C-95-72-8002 , REV-3
TUNNEL BOTTOM SLAB
//

1500
115
1000

1000
//

DESIGN SUB-CONTRACTOR NAME: CONTRACTOR NAME:


EXISTING Q-RAIL
QATARI ENGINEER & ASSOCIATES
TUNNEL TOP SLAB 1500 Grade - A. Arch'l, Struct'l & MEP Consultant
UPDA Reg.No.06
P.O.Box : 3529 Doha - Qatar Tel: +974 44417477 / 78 / 81 SIEMENS CONSORTIUM
//

Fax: +974 44419567. E-mail : qea@qatar.net.qa SIEMENS AG - SIEMENS WLL


115

Web: www.qeadoha.com

QEA/926/S
T25-150 T1 132/11kV AL SADD 3 SUBSTATION
SECTION 2-2 T25-150 T2 CONNECTION DETAILS FOR PROPOSED
SCALE 1:25 AND EXISTING TUNNEL WALL 29.03.2018
SHT.4 OF 4

You might also like